1.
Cardiovasc Revasc Med ; 21(1): 70-77, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31000433

RESUMEN

BACKGROUND: Long-term vascular healing, evaluated by optical coherence tomography (OCT) and histology, following complex bifurcation interventions with polymeric Absorb Bioresorbable Vascular Scaffold (BVS, Abbott Vascular, Santa Clara, CA) has not been previously described. METHODS: Fifteen New-Zealand-White rabbits (4.0 ±â€¯0.3 kg) underwent stenting of non-diseased aorto-iliac bifurcations with BVS using provisional stenting (PS, n = 2), culotte stenting (n = 7) and modified-T (n = 6) stenting techniques. At 18 months angiography, optical coherence tomography (OCT) and histology were performed. RESULTS: The acute angiographic results were excellent. Three rabbits succumbed acutely due to anaesthetic and renal complications, whilst one was euthanized electively at 4 months for a skin infection. At 18 months, 11 rabbits (PS (2), modified-T (4) and culotte (5)) underwent angiography, revealing excellent results, followed by OCT and histological evaluation. No acute scaffold thrombosis occurred. All non-bifurcation segments revealed complete endothelialisation with excellent healing characteristics on OCT and histology. Following one PS and all 2-stent techniques, uncovered, deformed and malapposed struts were present at the neocarina with adherent fibrin and chronic thrombus in 10/11 cases, extending as long fibrin strands (mean length 11.0 ±â€¯8.3 mm) in 3 culotte and 1 modified-T cases. Late intraluminal scaffold discontinuity was present following five 2-stent cases. CONCLUSIONS: Pathological vascular healing with uncovered, distorted and malapposed neocarinal struts with adherent strands of chronic thrombus, suggest that exposed polymeric breakdown products may be thrombogenic and caution against the use of polymeric BVS in interventions when there is a chance of suboptimal results with strut malapposition or compromise of scaffold integrity.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Vasos Coronarios/patología , Cicatrización de Heridas , Angioplastia Coronaria con Balón/efectos adversos , Animales , Angiografía Coronaria , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/etiología , Trombosis Coronaria/patología , Vasos Coronarios/diagnóstico por imagen , Neointima , Diseño de Prótesis , Conejos , Factores de Tiempo , Tomografía de Coherencia Óptica
2.
EuroIntervention ; 13(17): 2036-2046, 2018 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-28741575

RESUMEN

AIMS: This acute in vivo study sought to provide insights regarding the feasibility of performing complex bifurcation stenting with Magmaris magnesium alloy bioresorbable scaffolds (Biotronik, Bulach, Switzerland). METHODS AND RESULTS: Twenty-five New Zealand White rabbits underwent stenting of non-diseased aorto-iliac bifurcations with the Magmaris using provisional (PS; n=5), culotte (n=6), modified T (n=6), or T and protrusion (TAP, n=8) stenting techniques. Angiography, optical coherence tomography and micro-computed tomography were performed. Angiographic results were good without evidence of side branch (SB) compromise. In 9/25 procedures, strut fractures were identified with minimal luminal compromise in two cases. PS opened the SB optimally without evidence of scaffold compromise. Culotte resulted in complete bifurcation coverage and good scaffold expansion; single strut fractures were present in three out of six and double fractures in one out of six procedures. Modified T and TAP resulted in complete bifurcation coverage, minimal neocarina double-strut layers and good expansion. In two out of six modified T procedures, strut fractures were present with SB scaffold deformity present in an additional two out of six procedures. In three out of eight TAP procedures, strut fractures were present without compromising overall scaffold integrity. CONCLUSIONS: Bifurcation stenting using Magmaris appears feasible. PS with additional TAP whenever needed seems a reasonable approach. Whenever a two-stent technique is planned, TAP appears most favourable whilst modified T and culotte stenting should probably be avoided.


Asunto(s)
Enfermedad de la Arteria Coronaria , Vasos Coronarios , Stents Liberadores de Fármacos , Magnesio/farmacología , Intervención Coronaria Percutánea/instrumentación , Andamios del Tejido , Animales , Materiales Biocompatibles/farmacología , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiología , Vasos Coronarios/cirugía , Modelos Animales de Enfermedad , Estudios de Factibilidad , Ensayo de Materiales , Modelos Anatómicos , Imagen Multimodal , Intervención Coronaria Percutánea/métodos , Conejos , Tomografía de Coherencia Óptica/métodos , Microtomografía por Rayos X/métodos
3.
J Cardiovasc Transl Res ; 10(4): 348-358, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28397162

RESUMEN

Angiogenic growth factor therapy for ischemic cardiovascular disease carries a risk of stimulating atherosclerotic plaque growth. We evaluated risk benefit ratio of sustained administration of recombinant human placental growth factor (rhPlGF)-2 in mice with advanced atherosclerosis and chronic ischemic cardiomyopathy. We maintained apolipoprotein E-deficient mice on a high cholesterol diet and induced myocardial infarction by transient ligation at 4 weeks. At 8 weeks, we assessed left ventricular (LV) function and randomized mice to receive rhPlGF-2 or vehicle (VEH) subcutaneously for 28 days. Administration of rhPlGF-2 significantly increased PlGF plasma levels without adverse hemodynamic or systemic inflammatory effects. RhPlGF-2 did not increase plaque area, composition, or vulnerability in the aortic arch. RhPlGF-2 significantly improved contractile function and reduced LV end-systolic and end-diastolic volume indices with a concomitant increase in capillary and arteriolar density in ischemic myocardium. RhPlGF-2 may represent a promising therapeutic strategy in chronic ischemic cardiomyopathy.


Asunto(s)
Inductores de la Angiogénesis/administración & dosificación , Aorta/efectos de los fármacos , Enfermedades de la Aorta/tratamiento farmacológico , Aterosclerosis/tratamiento farmacológico , Cardiomiopatías/tratamiento farmacológico , Infarto del Miocardio/tratamiento farmacológico , Neovascularización Fisiológica/efectos de los fármacos , Factor de Crecimiento Placentario/administración & dosificación , Función Ventricular Izquierda/efectos de los fármacos , Inductores de la Angiogénesis/toxicidad , Animales , Aorta/patología , Aorta/fisiopatología , Enfermedades de la Aorta/patología , Enfermedades de la Aorta/fisiopatología , Aterosclerosis/patología , Aterosclerosis/fisiopatología , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Colesterol en la Dieta , Enfermedad Crónica , Modelos Animales de Enfermedad , Infusiones Subcutáneas , Masculino , Ratones Noqueados para ApoE , Contracción Miocárdica/efectos de los fármacos , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Factor de Crecimiento Placentario/toxicidad , Placa Aterosclerótica , Proteínas Recombinantes/administración & dosificación , Recuperación de la Función , Volumen Sistólico/efectos de los fármacos , Factores de Tiempo , Rigidez Vascular/efectos de los fármacos , Remodelación Ventricular/efectos de los fármacos
4.
Artículo en Inglés | MEDLINE | ID: mdl-27512090

RESUMEN

BACKGROUND: Although bioresorbable scaffolds offer potential advantages compared with metallic drug-eluting stents in the treatment of complex coronary bifurcation lesions, there are concerns that the polymeric scaffold integrity may be compromised. This in vivo study sought to provide insights about the feasibility of performing complex bifurcation stenting with Absorb bioresorbable vascular scaffolds (Abbott Vascular, Santa Clara, CA). METHODS AND RESULTS: Twenty New Zealand white rabbits underwent stenting of the nondiseased aortoiliac bifurcation with bioresorbable vascular scaffolds using provisional (PS, n=5), culotte (n=5), modified-T (n=5), or T-and protrusion (n=5) stenting techniques. Angiography, optical coherence tomography, and microcomputed tomography were performed. Angiographic results were excellent without evidence of dissection or side branch (SB) compromise. PS optimally opened the SB ostium without deforming the main vessel (MV) bioresorbable vascular scaffolds, avoiding malapposition, and revealing a single connector fracture in 1 of 5 cases on microcomputed tomography. Culotte stenting resulted in complete bifurcation coverage with extensive segments of double-layered struts and inappropriately apposed struts at the bifurcation level in 3 of 5 cases. On microcomputed tomography, there was MV and SB scaffold distortion at the bifurcation with single strut fractures in 4 of 5 and double fractures in 1 of 5. Modified-T and T-and protrusion resulted in complete bifurcation coverage and in minimal double-strut layers at the neocarina. On microcomputed tomography, no strut fractures were present after modified-T, whereas in 3 of 5 T-and protrusion procedures single strut fractures were noted. CONCLUSIONS: Bifurcation stenting using bioresorbable vascular scaffolds is feasible with excellent angiographic results. PS with additional T-and protrusion whenever needed seems a reasonable approach. Whenever a 2-stent technique is planned, modified T-stenting appears the most promising.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/métodos , Imagen Multimodal , Andamios del Tejido , Angioplastia Coronaria con Balón/instrumentación , Animales , Angiografía Coronaria , Imagenología Tridimensional , Conejos , Stents , Tomografía de Coherencia Óptica , Microtomografía por Rayos X
5.
Int J Cardiol ; 203: 534-42, 2016 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-26569359

RESUMEN

OBJECTIVES: We investigated whether sustained infusion of recombinant human placental growth factor-2 (rhPlGF-2) improves myocardial perfusion and left ventricular (LV) function in a porcine model of ischemic cardiomyopathy (ICM). METHODS: We induced myocardial ischemia using a flow-limiting stent in the LAD. Four weeks later, we randomized pigs with confirmed myocardial dysfunction to blinded rhPlGF-2 administration (PlGF2, 15 µg/kg/day, 14 days) or PBS (CON). At 8 weeks, we measured hemodynamics, contractile function and regional perfusion at rest and during stress using MRI and microspheres. We evaluated neovascularization post mortem. RESULTS: RhPlGF-2 administration increased PlGF serum levels more than 63-fold (83 3 ± 361 versus 11 ± 5 pg/ml CON, P<0.05) without adverse effects. After 4weeks, rhPlGF-2 significantly enhanced perfusion in the ischemic region at rest (0.83 ± 0.32 versus 0.58 ± 0.21 ml/min/g CON, P<0.05) and during hyperemia (1.50 ± 0.50 versus 1.02 ± 0.46 ml/min/g CON, P<0.05). Consequently, regional contractile function in rhPlGF-2-treated pigs improved at rest (37 ± 15% versus 23 ± 9% CON, P<0.05) and during high dose dobutamine stress (53 ± 31% versus 27 ± 16% CON, P<0.05). Enhanced perfusion translated into a greater improvement in LV ejection fraction and in preload-recruitable stroke work in rhPlGF-2-treated animals than in CON (52 ± 11 versus 41 ± 9%, and 76 ± 24 versus 41 ± 21 mmHg, respectively, P<0.05 for both), which was associated with significantly greater vascular density in the ischemic region. CONCLUSIONS: In chronic ICM, systemic rhPlGF-2 administration significantly enhances regional myocardial perfusion, contractile function at rest and during stress, and induces a prominent recovery of global cardiac function. PlGF-2 protein infusion is safe and may represent a promising therapy in chronic ICM.


Asunto(s)
Proteínas de la Membrana/uso terapéutico , Isquemia Miocárdica/tratamiento farmacológico , Guías de Práctica Clínica como Asunto , Proteínas Recombinantes/uso terapéutico , Animales , Enfermedad Crónica , Cricetinae , Modelos Animales de Enfermedad , Femenino , Estudios de Seguimiento , Masculino , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/metabolismo , Miocardio/patología , Porcinos , Factores de Tiempo , Resultado del Tratamiento
6.
J Am Heart Assoc ; 5(4): e002288, 2016 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-27091182

RESUMEN

BACKGROUND: Blood outgrowth endothelial cells (BOECs) mediate therapeutic neovascularization in experimental models, but outgrowth characteristics and functionality of BOECs from patients with ischemic cardiomyopathy (ICMP) are unknown. We compared outgrowth efficiency and in vitro and in vivo functionality of BOECs derived from ICMP with BOECs from age-matched (ACON) and healthy young (CON) controls. METHODS AND RESULTS: We isolated 3.6±0.6 BOEC colonies/100×10(6) mononuclear cells (MNCs) from 60-mL blood samples of ICMP patients (n=45; age: 66±1 years; LVEF: 31±2%) versus 3.5±0.9 colonies/100×10(6) MNCs in ACON (n=32; age: 60±1 years) and 2.6±0.4 colonies/100×10(6) MNCs in CON (n=55; age: 34±1 years), P=0.29. Endothelial lineage (VEGFR2(+)/CD31(+)/CD146(+)) and progenitor (CD34(+)/CD133(-)) marker expression was comparable in ICMP and CON. Growth kinetics were similar between groups (P=0.38) and not affected by left ventricular systolic dysfunction, maladaptive remodeling, or presence of cardiovascular risk factors in ICMP patients. In vitro neovascularization potential, assessed by network remodeling on Matrigel and three-dimensional spheroid sprouting, did not differ in ICMP from (A)CON. Secretome analysis showed a marked proangiogenic profile, with highest release of angiopoietin-2 (1.4±0.3×10(5) pg/10(6) ICMP-BOECs) and placental growth factor (5.8±1.5×10(3) pg/10(6) ICMP BOECs), independent of age or ischemic disease. Senescence-associated ß-galactosidase staining showed comparable senescence in BOECs from ICMP (5.8±2.1%; n=17), ACON (3.9±1.1%; n=7), and CON (9.0±2.8%; n=13), P=0.19. High-resolution microcomputed tomography analysis in the ischemic hindlimb of nude mice confirmed increased arteriogenesis in the thigh region after intramuscular injections of BOECs from ICMP (P=0.025; n=8) and CON (P=0.048; n=5) over vehicle control (n=8), both to a similar extent (P=0.831). CONCLUSIONS: BOECs can be successfully culture-expanded from patients with ICMP. In contrast to impaired functionality of ICMP-derived bone marrow MNCs, BOECs retain a robust proangiogenic profile, both in vitro and in vivo, with therapeutic potential for targeting ischemic disease.


Asunto(s)
Endotelio Vascular/fisiopatología , Isquemia Miocárdica/fisiopatología , Neovascularización Fisiológica/fisiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Animales , Estudios de Casos y Controles , Proliferación Celular/fisiología , Células Cultivadas , Endotelio Vascular/citología , Endotelio Vascular/trasplante , Femenino , Humanos , Masculino , Ratones Desnudos , Persona de Mediana Edad , Estrés Oxidativo/fisiología , Adulto Joven
7.
Eur Heart J Cardiovasc Imaging ; 15(8): 900-7, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24596052

RESUMEN

AIM: Biological therapies for ischaemic heart disease require efficient, safe, and affordable intramyocardial delivery. Integration of multiple imaging modalities within the fluoroscopy framework can provide valuable information to guide these procedures. We compared an anatomo-electric method (LARCA) with a non-fluoroscopic electromechanical mapping system (NOGA(®)). LARCA integrates selective three-dimensional-rotational angiograms with biplane fluoroscopy. To identify the infarct region, we studied LARCA-fusion with pre-procedural magnetic resonance imaging (MRI), dedicated CT, or (18)F-FDG-PET/CT. METHODS AND RESULTS: We induced myocardial infarction in 20 pigs by 90-min LAD occlusion. Six weeks later, we compared peri-infarct delivery accuracy of coloured fluospheres using sequential NOGA(®)- and LARCA-MRI-guided vs. LARCA-CT- and LARCA-(18)F-FDG-PET/CT-guided intramyocardial injections. MRI after 6 weeks revealed significant left ventricular (LV) functional impairment and remodelling (LVEF 31 ± 3%, LVEDV 178 ± 15 mL, infarct size 17 ± 2% LV mass). During NOGA(®)-procedures, three of five animals required DC-shock for major ventricular arrhythmias vs. one of ten during LARCA-procedures. Online procedure time was shorter for LARCA than NOGA(®) (77 ± 6 vs. 130 ± 3 min, P < 0.0001). Absolute distance of injection spots to the infarct border was similar for LARCA-MRI (4.8 ± 0.5 mm) and NOGA(®) (5.4 ± 0.5 mm). LARCA-CT-integration allowed closer approximation of the targeted border zone than LARCA-PET (4.0 ± 0.5 mm vs. 6.2 ± 0.6 mm, P < 0.05). CONCLUSION: Three-dimensional -rotational angiography fused with multimodal imaging offers a new, cost-effective, and safe strategy to guide intramyocardial injections. Endoventricular procedure times and arrhythmias compare favourably to NOGA(®), without compromising injection accuracy. LARCA-based fusion imaging is a promising enabling technology for cardiac biological therapies.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Angiografía Coronaria/métodos , Imagenología Tridimensional/métodos , Imagen Multimodal , Infarto del Miocardio/patología , Radiografía Intervencional/métodos , Algoritmos , Animales , Colorantes , Modelos Animales de Enfermedad , Fenómenos Electrofisiológicos , Fluorodesoxiglucosa F18 , Fluoroscopía , Inyecciones , Imagen por Resonancia Cinemagnética , Microesferas , Tomografía de Emisión de Positrones , Porcinos
8.
Cardiovasc Pathol ; 21(3): 129-31, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-21943888

RESUMEN

BACKGROUND: Microvascular obstruction after reperfusion therapy of acute myocardial infarction is reported as an adverse promoter of left ventricular remodeling and is an important target to prevent deterioration into heart failure. In this study, we illustrate the early onset of a magnetic resonance imaged microvascular obstruction in a porcine model of acute myocardial infarction with the exact histological correlate. METHODS: Occlusion of the left anterior descending coronary artery followed by 3-h reperfusion was performed in 10 pigs. Microvascular obstruction was assessed by contrast-enhanced magnetic resonance imaging (MRI). After sacrifice, serial sectioned slices of the hearts matching the MRI were stained with Triphenyl tetrazolium chloride (TTC). Biopsies were fixed, embedded in paraffin, and stained for hematoxylin-eosin. RESULTS: Microvascular obstruction was defined with MRI as a hypoenhanced no-reflow area within the hyperenhanced infarct region. Erythrocyte plugging was consistently observed in the no-reflow area and was completely absent in the adjacent hyperenhanced infarct region. CONCLUSION: This model of acute ischemia-reperfusion contributes to the histological comprehension of contrast-enhanced MRI during the early stages of myocardial infarction.


Asunto(s)
Angiografía por Resonancia Magnética/métodos , Daño por Reperfusión Miocárdica/patología , Miocardio/patología , Animales , Colorantes/química , Modelos Animales de Enfermedad , Microcirculación , Infarto del Miocardio/patología , Miocardio/química , Porcinos , Sales de Tetrazolio/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA