RESUMEN
BACKGROUND: To evaluate the impact of anatomical variations in the Circle of Willis (CoW) on immediate neurological events (INEs) after carotid endarterectomy (CEA) without shunting in patients with contralateral carotid occlusion (CCO). METHODS: Single-center retrospective study. Patient's demographic and clinical outcomes data were prospectively collected. CoW segments were reviewed retrospectively. Between January 2013 and May 2018, 2090 patients underwent CEA under general anesthesia, CCO was found in 113 (5.4%) patients. CoW segments were classified as normal, hypoplastic (diameter Ë0.8 mm), or absent based on computed tomography angiography. We studied the CoW segments as 2 collateral networks connecting the basilar artery and the ipsilateral middle cerebral artery: a short semicircle (first segment of the ipsilateral posterior cerebral artery [P1] and posterior communicating artery [Pcom] segment) and a long semicircle (contralateral P1, Pcom, and both first segments of the anterior cerebri artery (A1) anterior communicating artery (Acom)). INE was defined as any transient ischemic attack or stroke diagnosed immediately after the procedure. RESULTS: Out of the 113 patients, 46 underwent endarterectomy with shunting. We further excluded 16 patients from the assessment of the CoW due to unavailability or inadequate quality of computed tomography angiography. Of the 113 patients, 2 had strokes, 1 with shunting that occurred hrs after surgery. Besides the other stroke case, 4 INE were observed, all without the use of a shunt. Of the 51 patients with CoW assessment, 10 (19.6%) had a complete CoW, while 21 (41.2%) patients had only 1 semicircle intact (10 short and 11 long intact semicircles), and none of these patients experienced an INE. A total of 20 (39%) patients had both the long and short semicircles incomplete, of which 4 (7.8%) cases had an INE. In all INE cases, at least 1 of the Pcom was absent or hypoplastic. The absence of both Pcom was a strong predictor of incident INE [odds ratio = 11.10 (confidence interval: 1.04-118.60)] for INE. CONCLUSIONS: Patients with CCO and insufficient CoW collateral flow support are at an increased risk of INE, including stroke, in the absence of shunt protection during CEA cross-clamping. Shunting should always be considered when the collateral flow between the ipsilateral middle cerebral artery and the basilar artery is compromised in CCO patients.
Asunto(s)
Estenosis Carotídea , Circulación Cerebrovascular , Círculo Arterial Cerebral , Endarterectomía Carotidea , Ataque Isquémico Transitorio , Humanos , Endarterectomía Carotidea/efectos adversos , Círculo Arterial Cerebral/fisiopatología , Círculo Arterial Cerebral/diagnóstico por imagen , Estudios Retrospectivos , Femenino , Masculino , Anciano , Resultado del Tratamiento , Factores de Riesgo , Persona de Mediana Edad , Estenosis Carotídea/cirugía , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/complicaciones , Estenosis Carotídea/fisiopatología , Ataque Isquémico Transitorio/etiología , Circulación Colateral , Accidente Cerebrovascular/etiología , Medición de Riesgo , Factores de Tiempo , Anciano de 80 o más Años , Angiografía por Tomografía ComputarizadaRESUMEN
OBJECTIVES: Virtual monoenergetic images (VMIs) from photon-counting CT (PCCT) may change quantitative coronary plaque volumes. We aimed to assess how plaque component volumes change with respect to VMIs. METHODS: Coronary CT angiography (CTA) images were acquired using a dual-source PCCT and VMIs were reconstructed between 40 and 180 keV in 10-keV increments. Polychromatic images at 120 kVp (T3D) were used as reference. Quantitative plaque analysis was performed on T3D images and segmentation masks were copied to VMI reconstructions. Calcified plaque (CP; > 350 Hounsfield units, HU), non-calcified plaque (NCP; 30 to 350 HU), and low-attenuation NCP (LAP; - 100 to 30 HU) volumes were calculated using fixed thresholds. RESULTS: We analyzed 51 plaques from 51 patients (67% male, mean age 65 ± 12 years). Average attenuation and contrast-to-noise ratio (CNR) decreased significantly with increasing keV levels, with similar values observed between T3D and 70 keV images (299 ± 209 vs. 303 ± 225 HU, p = 0.15 for mean HU; 15.5 ± 3.7 vs. 15.8 ± 3.5, p = 0.32 for CNR). Mean NCP volume was comparable between T3D and 100-180-keV reconstructions. There was a monotonic decrease in mean CP volume, with a significant difference between all VMIs and T3D (p < 0.05). LAP volume increased with increasing keV levels and all VMIs showed a significant difference compared to T3D, except for 50 keV (28.0 ± 30.8 mm3 and 28.6 ± 30.1 mm3, respectively, p = 0.63). CONCLUSIONS: Estimated coronary plaque volumes significantly differ between VMIs. Normalization protocols are needed to have comparable results between future studies, especially for LAP volume which is currently defined using a fixed HU threshold. CLINICAL RELEVANCE STATEMENT: Different virtual monoenergetic images from photon-counting CT alter attenuation values and therefore corresponding plaque component volumes. New clinical standards and protocols are required to determine the optimal thresholds to derive plaque volumes from photon-counting CT. KEY POINTS: ⢠Utilizing different VMI energy levels from photon-counting CT for the analysis of coronary artery plaques leads to substantial changes in attenuation values and corresponding plaque component volumes. ⢠Low-energy images (40-70 keV) improved contrast-to-noise ratio, however also increased image noise. ⢠Normalization protocols are needed to have comparable results between future studies, especially for low-attenuation plaque volume which is currently defined using a fixed HU threshold.
Asunto(s)
Placa Aterosclerótica , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Placa Aterosclerótica/diagnóstico por imagen , Estudios Retrospectivos , Imagen Radiográfica por Emisión de Doble Fotón/métodosRESUMEN
PURPOSE: Endovascular aortic repair has become the preferred elective treatment of infrarenal aortic aneurysms. Aortic pulsatility may pose problems regarding endograft sizing. The aims of this study are to determine the aortic pulsatility in patients with aortic disease and to evaluate the effect of pulsatility on the growth of aneurysms. MATERIALS AND METHODS: In this retrospective study, analyses of computed tomography angiography (CTA) images of 31 patients under conservative treatment for small abdominal aortic aneurysms were performed. Reconstructions of the raw electrocardiography (ECG) gated dataset at 30% and 90% of the R-R cycle were used. After lumen segmentation, total aortic cross-sectional area was measured in diastole and systole in the following zones: Z0, Z3, Z5, Z6, Z8, and Z9. Effective diameters (EDs) were calculated from the systolic (EDsys) and diastolic (EDdia) cross-sectional areas to determine absolute (EDsys - EDdia, mm) and relative pulsatility [(EDsys - EDdia) / EDdia, %]. Diameter of the aneurysms was measured on baseline images and the last preoperative follow-up study of each patient. RESULTS: A total of 806 measurements were completed, 24 pulsatility and 2 growth measurements per patient. The mean pulsatility values at each point were as follows: Z0: 0.7±0.8 mm, Z3: 1.0±0.6 mm, Z5: 1.0±0.6 mm, Z6: 0.8±0.7 mm, Z8: 0.7±1.0 mm, Z9: 0.9±0.9 mm. Follow-up time was 5.5±2.2 years during which a growth of 13.42±9.09 mm (2.54±1.55 mm yearly) was observed. No correlation was found between pulsatility values and growth rate of the aneurysms. CONCLUSION: The pulsatility of the aorta is in a submillimetric range for the vast majority of patients with aortic disease, thus probably not relevant regarding endograft sizing. Pulsatility of the ascending aorta is smaller than that of the descending segment, making an additional oversize of a Z0 implantation questionable. CLINICAL IMPACT: Endovascular aortic repair reqiures precise preoperative planning. Pulsatile changes of the aortic diameter may pose issues regarding endograft sizing. In our retrospective single-centre study, aortic pulsatility of patients with AAA was measured on ECG gated CTA images. Pulsatility values reached a maximum at the descending aorta, however absolute pulsatility values did not exceed 1 mm at any point along the aorta. Therefore, significance of aortic pulsatility regarding the sizing of EVAR prostheses is questionable. Correlation between pulsatility and AAA growth was not found.
RESUMEN
BACKGROUND: Coronary low-attenuation plaque (LAP) burden is a strong predictor of myocardial infarction in patients with stable chest pain. We aimed to assess the relationship between LAP burden and circulating levels of high-sensitivity cardiac troponin T (hs-cTnT), and to explore the potential underlying etiology in patients undergoing clinically indicated coronary CT angiography (CCTA). METHODS: A comprehensive metabolic and lipid panel, as well as C-reactive protein (CRP) and hs-cTnT tests were obtained from consecutive patients with stable chest pain at the time of CCTA. Qualitative and quantitative coronary plaque analysis, CT-derived fractional flow reserve (FFR) calculation, and pericoronary adipose tissue (PCAT) attenuation measurement around the right coronary artery were performed on CCTA images. Linear regression analyses were performed to identify independent associations with hs-cTnT concentration and mediation analysis was used to assess whether ischemia or markers of inflammation mediate hs-cTnT elevation. RESULTS: In total, 114 patients (56.3 â± â10.6 years, 44.7 â% female) were enrolled. In multivariable analysis, age (ß â= â0.04 [95%CI: 0.02; 0.06], p â< â0.001), female sex (ß â= â-0.77 [95%CI: -1.20; 0.33], p â< â0.001), and LAP burden (ß â= â0.03 [95%CI: 0.001; 0.06], p â= â0.04) were independently associated with hs-cTnT levels. Mediation analysis, on the other hand, did not identify a significant mediating effect of lesion-specific ischemia based on CT-FFR, circulating CRP levels, or PCAT values between LAP burden and hs-cTnT levels (all p â> â0.05). CONCLUSION: Although ischemia and inflammation have previously been proposed to mediate the association between LAP burden and hs-cTnT levels, our results did not confirm the role of these pathophysiological pathways in patients with stable chest pain.
Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Infarto del Miocardio , Placa Aterosclerótica , Humanos , Femenino , Masculino , Troponina , Análisis de Mediación , Biomarcadores , Valor Predictivo de las Pruebas , Angiografía Coronaria/métodos , Dolor en el Pecho , Angiografía por Tomografía Computarizada/métodos , Troponina T , Síndrome , Inflamación , Enfermedad de la Arteria Coronaria/diagnóstico por imagenRESUMEN
BACKGROUND: The introduction of photon-counting detector computed tomography (PCD-CT) heralds a new generation of cardiac imaging. OBJECTIVES: This review discusses the current scientific literature to determine the incremental value of PCD-CT in cardiac imaging. METHODS: Discussion of currently available literature regarding cardiac PCD-CT from a radiological perspective. RESULTS: Since its market introduction in 2021, numerous studies have explored the advantages of this new technology in the field of cardiac imaging, including improved image quality through superior spatial resolution, a higher contrast-to-noise ratio, reduced artifacts, and lower radiation dose. CONCLUSION: While preliminary studies have been promising, it remains to be seen how the advantages of PCD-CT will affect clinical guidelines for cardiac CT.
RESUMEN
BACKGROUND: Radiomics is not yet used in clinical practice due to concerns regarding its susceptibility to technical factors. We aimed to assess the stability and interscan and interreader reproducibility of myocardial radiomic features between energy-integrating detector computed tomography (EID-CT) and photon-counting detector CT (PCD-CT) in patients undergoing coronary CT angiography (CCTA) on both systems. METHODS: Consecutive patients undergoing clinically indicated CCTA on an EID-CT were prospectively enrolled for a PCD-CT CCTA within 30 days. Virtual monoenergetic images (VMI) at various keV levels and polychromatic images (T3D) were generated for PCD-CT, with image reconstruction parameters standardized between scans. Two readers performed myocardial segmentation and 110 radiomic features were compared intraindividually between EID-CT and PDC-CT series. The agreement of parameters was assessed using the intraclass correlation coefficient and paired t-test for the stability of the parameters. RESULTS: Eighteen patients (15 males) aged 67.6 ± 9.7 years (mean ± standard deviation) were included. Besides polychromatic PCD-CT reconstructions, 60- and 70-keV VMIs showed the highest feature stability compared to EID-CT (96%, 90%, and 92%, respectively). The interscan reproducibility of features was moderate even in the most favorable comparisons (median ICC 0.50 [interquartile range 0.20-0.60] for T3D; 0.56 [0.33-0.74] for 60 keV; 0.50 [0.36-0.62] for 70 keV). Interreader reproducibility was excellent for the PCD-CT series and good for EID-CT segmentations. CONCLUSION: Most myocardial radiomic features remain stable between EID-CT and PCD-CT. While features demonstrated moderate reproducibility between scanners, technological advances associated with PCD-CT may lead to greater reproducibility, potentially expediting future standardization efforts. RELEVANCE STATEMENT: While the use of PCD-CT may facilitate reduced interreader variability in radiomics analysis, the observed interscanner variations in comparison to EID-CT should be taken into account in future research, with efforts being made to minimize their impact in future radiomics studies. KEY POINTS: Most myocardial radiomic features resulted in being stable between EID-CT and PCD-CT on certain VMIs. The reproducibility of parameters between detector technologies was limited. PCD-CT improved interreader reproducibility of myocardial radiomic features.
Asunto(s)
Angiografía por Tomografía Computarizada , Humanos , Masculino , Femenino , Anciano , Reproducibilidad de los Resultados , Angiografía por Tomografía Computarizada/métodos , Estudios Prospectivos , Fotones , Angiografía Coronaria/métodos , Persona de Mediana Edad , RadiómicaRESUMEN
RATIONALE AND OBJECTIVES: Coronary CT angiography (CCTA) has recently been established as a first-line test in patients with suspected coronary artery disease (CAD). Due to the increased use of CCTA, strategies to reduce radiation and contrast medium (CM) exposure are of high importance. The aim of this study was to evaluate the performance of automated tube voltage selection (ATVS)-adapted CM injection protocol for CCTA compared to a clinically established triphasic injection protocol in terms of image quality, radiation exposure, and CM administration MATERIAL AND METHODS: Patients undergoing clinically indicated CCTA were prospectively enrolled from July 2021 to July 2023. Patients underwent CCTA using a modified triphasic CM injection protocol tailored to the tube voltage by the ATVS algorithm, in a range of 70 to 130 kV with a 10 kV interval. The injection protocol consisted of two phases of mixed CM and saline boluses with different proportions to assure a voltage-specific iodine delivery rate, followed by a third phase of saline flush. This cohort was compared to a control group identified retrospectively and scanned on the same CT system but with a standard triphasic CM protocol. Radiation and contrast dose, subjective and objective image quality (contrast-to-noise-ratio [CNR] and signal-to-noise-ratio [SNR]) were compared between the two groups. RESULTS: The final population consisted of 120 prospective patients matched with 120 retrospective controls, with 20 patients in each kV group. The 120 kV group was excluded from the statistical analysis due to insufficient sample size. A significant CM reduction was achieved in the prospective group overall (46.0 [IQR 37.0-52.0] vs. 51.3 [IQR 40.1-73.0] mL, p < 0.001) and at all kV levels too (all pairwise p < 0.001). There were no significant differences in radiation dose (6.13 ± 4.88 vs. 5.97 ± 5.51 mSv, p = 0.81), subjective image quality (median score of 4 [3-5] vs. 4 [3-5], p = 0.40), CNR, and SNR in the aorta and the left anterior descending coronary artery (all p > 0.05). CONCLUSION: ATVS-adapted CM injection protocol allows for diagnostic quality CCTA with reduced CM volume while maintaining similar radiation exposure, subjective and objective image quality.
Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Dosis de Radiación , Humanos , Medios de Contraste/administración & dosificación , Angiografía por Tomografía Computarizada/métodos , Femenino , Masculino , Angiografía Coronaria/métodos , Estudios Prospectivos , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios de Casos y Controles , Anciano , Exposición a la Radiación/prevención & control , Exposición a la Radiación/análisis , AlgoritmosRESUMEN
Background: Air embolism is a known risk during thoracic endovascular aortic repair (TEVAR) and is associated with an incomplete deairing of the delivery system despite the saline lavage recommended by the instructions for use (IFU). As the delivery systems are identical and residual air remains frequently in the abdominal aortic aneurysm sac, endovascular aortic repair (EVAR) can be used to examine the effectiveness of deairing maneuvers. We aimed to evaluate whether increasing the flush volume can result in a more complete deairing. Methods: Patients undergoing EVAR were randomly assigned according to flushing volume (Group A, 1× IFU; Group B, 4× IFU). The Terumo Aortic Anaconda and Treo and Cook Zenith Alpha Abdominal stent grafts were randomly implanted in equal distribution (10-10-10). The quantity of air trapped in the aneurysm sac was measured using a pre-discharge computed tomography angiography (CTA). Thirty patients were enrolled and equally distributed between the two groups, with no differences observed in any demographic or anatomical factors. Results: The presence of air was less frequent in Group A compared to that in Group B [7 (47%) vs. 13 (87%), p = .02], and the air volume was less in Group A compared to that in Group B (103.5 ± 210.4 vs. 175.5 ± 175.0â mm3, p = .04). Additionally, the volume of trapped air was higher with the Anaconda graft type (p = .025). Discussion: These findings suggest that increased flushing volume is associated with a higher amount of trapped air; thus, following the IFU might be associated with a reduced risk of air embolization. Furthermore, significant differences were identified between devices in terms of the amount of trapped air. Clinical trial registration: [NCT04909190], [ClinicalTrials.gov].
RESUMEN
PURPOSE: To explore the potential differences in epicardial adipose tissue (EAT) volume and attenuation measurements between photon-counting detector (PCD) and energy-integrating detector (EID)-CT systems. METHODS: Fifty patients (mean age 69 ± 8 years, 41 male [82 %]) were prospectively enrolled for a research coronary CT angiography (CCTA) on a PCD-CT within 30 days after clinical EID-based CCTA. EID-CT acquisitions were reconstructed using a Bv40 kernel at 0.6 mm slice thickness. The PCD-CT acquisition was reconstructed at a down-sampled resolution (0.6 mm, Bv40; [PCD-DS]) and at ultra-high resolutions (PCD-UHR) with a 0.2 mm slice thickness and Bv40, Bv48, and Bv64 kernels. EAT segmentation was performed semi-automatically at about 1 cm intervals and interpolated to cover the whole epicardium within a threshold of -190 to -30 HU. A subgroup analysis was performed based on quartile groups created from EID-CT data and PCD-UHRBv48 data. Differences were measured using repeated-measures ANOVA and the Friedman test. Correlations were tested using Pearson's and Spearman's rho, and agreement using Bland-Altman plots. RESULTS: EAT volumes significantly differed between some reconstructions (e.g. EID-CT: 138 ml [IQR 100, 188]; PCD-DS: 147 ml [110, 206]; P<0.001). Overall, correlations between PCD-UHR and EID-CT EAT volumes were excellent, e.g. PCD-UHRBv48: r: 0.976 (95 % CI: 0.958, 0.987); P<0.001; with good agreement (mean bias: -9.5 ml; limits of agreement [LoA]: -40.6, 21.6). On the other hand, correlations regarding EAT attenuation was moderate, e.g. PCD-UHRBV48: r: 0.655 (95 % CI: 0.461, 0.790); P<0.001; mean bias: 6.5 HU; LoA: -2.0, 15.0. CONCLUSION: EAT attenuation and volume measurements demonstrated different absolute values between PCD-UHR, PCD-DS as well as EID-CT reconstructions, but showed similar tendencies on an intra-individual level. New protocols and threshold ranges need to be developed to allow comparison between PCD-CT and EID-CT data.
RESUMEN
PURPOSE: To assess the impact of different quantum iterative reconstruction (QIR) levels on objective and subjective image quality of ultra-high resolution (UHR) coronary CT angiography (CCTA) images and to determine the effect of strength levels on stenosis quantification using photon-counting detector (PCD)-CT. METHOD: A dynamic vessel phantom containing two calcified lesions (25 % and 50 % stenosis) was scanned at heart rates of 60, 80 and 100 beats per minute with a PCD-CT system. In vivo CCTA examinations were performed in 102 patients. All scans were acquired in UHR mode (slice thickness0.2 mm) and reconstructed with four different QIR levels (1-4) using a sharp vascular kernel (Bv64). Image noise, signal-to-noise ratio (SNR), sharpness, and percent diameter stenosis (PDS) were quantified in the phantom, while noise, SNR, contrast-to-noise ratio (CNR), sharpness, and subjective quality metrics (noise, sharpness, overall image quality) were assessed in patient scans. RESULTS: Increasing QIR levels resulted in significantly lower objective image noise (in vitro and in vivo: both p < 0.001), higher SNR (both p < 0.001) and CNR (both p < 0.001). Sharpness and PDS values did not differ significantly among QIRs (all pairwise p > 0.008). Subjective noise of in vivo images significantly decreased with increasing QIR levels, resulting in significantly higher image quality scores at increasing QIR levels (all pairwise p < 0.001). Qualitative sharpness, on the other hand, did not differ across different levels of QIR (p = 0.15). CONCLUSIONS: The QIR algorithm may enhance the image quality of CCTA datasets without compromising image sharpness or accurate stenosis measurements, with the most prominent benefits at the highest strength level.
Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Estenosis Coronaria , Fantasmas de Imagen , Fotones , Relación Señal-Ruido , Humanos , Angiografía por Tomografía Computarizada/métodos , Masculino , Femenino , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , AlgoritmosRESUMEN
PURPOSE: We aimed to identify the optimal reconstruction settings based on qualitative and quantitative image quality parameters on standard and ultra-high resolution (UHR) images using photon-counting CT (PCCT). METHOD: We analysed 45 patients, 29 with standard and 16 with UHR acquisition, applying both smoother and sharper kernel settings. Coronary CT angiography images were performed on a dual-source PCCT system using standard (0.4/0.6 mm slice thickness, Bv40/Bv44 kernels, QIR levels 0-4) or UHR acquisition (0.2/0.4 mm slice thickness, Bv44/Bv56 kernels, QIR levels 0-4). Qualitative image quality was assessed using a 4-point Likert scale. Image noise (SD), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated in both the proximal and distal segments. RESULTS: On standard resolution, larger slice thickness resulted in an average increase of 12.5 % in CNR, whereas sharper kernel led to an average 8.7 % decrease in CNR. Highest CNR was measured on 0.6 mm, Bv40, QIR4 images and lowest on 0.4 mm, Bv44, QIR0 images: 25.8 ± 4.1vs.8.3 ± 1.6 (p < 0.001). On UHR images, highest CNR was observed on 0.4 mm, Bv40, QIR4 and lowest on 0.2 mm, Bv56 and QIR0 images: 21.5 ± 3.9vs.3.6 ± 0.8 (p < 0.001). Highest qualitative image quality was found on images with Bv44 kernel and QIR level 3/4 with both slice thicknesses on standard reconstruction. Additionally, Bv56 with QIR4 on 0.2 mm slice thickness images showed highest subjective image quality. Preserved distal vessel visualization was detected using QIR 2-4, Bv56 and 0.2 mm slice thickness. CONCLUSIONS: Photon-counting CT demonstrated high qualitative and quantitative image quality for the assessment of coronaries and stents.
Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Fotones , Humanos , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Relación Señal-Ruido , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reproducibilidad de los Resultados , AdultoRESUMEN
BACKGROUND: The potential role of cardiac computed tomography (CT) has increasingly been demonstrated for the assessment of diffuse myocardial fibrosis through the quantification of extracellular volume (ECV). Photon-counting detector (PCD)-CT technology may deliver more accurate ECV quantification compared to energy-integrating detector CT. We evaluated the impact of reconstruction settings on the accuracy of ECV quantification using PCD-CT, with magnetic resonance imaging (MRI)-based ECV as reference. METHODS: In this post hoc analysis, 27 patients (aged 53.1 ± 17.2 years (mean ± standard deviation); 14 women) underwent same-day cardiac PCD-CT and MRI. Late iodine CT scans were reconstructed with different quantum iterative reconstruction levels (QIR 1-4), slice thicknesses (0.4-8 mm), and virtual monoenergetic imaging levels (VMI, 40-90 keV); ECV was quantified for each reconstruction setting. Repeated measures ANOVA and t-test for pairwise comparisons, Bland-Altman plots, and Lin's concordance correlation coefficient (CCC) were used. RESULTS: ECV values did not differ significantly among QIR levels (p = 1.000). A significant difference was observed throughout different slice thicknesses, with 0.4 mm yielding the highest agreement with MRI-based ECV (CCC = 0.944); 45-keV VMI reconstructions showed the lowest mean bias (0.6, 95% confidence interval 0.1-1.4) compared to MRI. Using the most optimal reconstruction settings (QIR4. slice thickness 0.4 mm, VMI 45 keV), a 63% reduction in mean bias and a 6% increase in concordance with MRI-based ECV were achieved compared to standard settings (QIR3, slice thickness 1.5 mm; VMI 65 keV). CONCLUSIONS: The selection of appropriate reconstruction parameters improved the agreement between PCD-CT and MRI-based ECV. RELEVANCE STATEMENT: Tailoring PCD-CT reconstruction parameters optimizes ECV quantification compared to MRI, potentially improving its clinical utility. KEY POINTS: ⢠CT is increasingly promising for myocardial tissue characterization, assessing focal and diffuse fibrosis via late iodine enhancement and ECV quantification, respectively. ⢠PCD-CT offers superior performance over conventional CT, potentially improving ECV quantification and its agreement with MRI-based ECV. ⢠Tailoring PCD-CT reconstruction parameters optimizes ECV quantification compared to MRI, potentially improving its clinical utility.
Asunto(s)
Imagen por Resonancia Magnética , Miocardio , Tomografía Computarizada por Rayos X , Humanos , Femenino , Persona de Mediana Edad , Masculino , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Anciano , Fotones , Adulto , Procesamiento de Imagen Asistido por Computador/métodos , Corazón/diagnóstico por imagenRESUMEN
This study evaluated a deep neural network (DNN) algorithm for automated aortic diameter quantification and aortic dissection detection in chest computed tomography (CT). A total of 100 patients (median age: 67.0 [interquartile range 55.3/73.0] years; 60.0% male) with aortic aneurysm who underwent non-enhanced and contrast-enhanced electrocardiogram-gated chest CT were evaluated. All the DNN measurements were compared to manual assessment, overall and between the following subgroups: (1) ascending (AA) vs. descending aorta (DA); (2) non-obese vs. obese; (3) without vs. with aortic repair; (4) without vs. with aortic dissection. Furthermore, the presence of aortic dissection was determined (yes/no decision). The automated and manual diameters differed significantly (p < 0.05) but showed excellent correlation and agreement (r = 0.89; ICC = 0.94). The automated and manual values were similar in the AA group but significantly different in the DA group (p < 0.05), similar in obese but significantly different in non-obese patients (p < 0.05) and similar in patients without aortic repair or dissection but significantly different in cases with such pathological conditions (p < 0.05). However, in all the subgroups, the automated diameters showed strong correlation and agreement with the manual values (r > 0.84; ICC > 0.9). The accuracy, sensitivity and specificity of DNN-based aortic dissection detection were 92.1%, 88.1% and 95.7%, respectively. This DNN-based algorithm enabled accurate quantification of the largest aortic diameter and detection of aortic dissection in a heterogenous patient population with various aortic pathologies. This has the potential to enhance radiologists' efficiency in clinical practice.
RESUMEN
BACKGROUND: We compared ultra-high resolution (UHR), standard resolution (SR), and virtual non-calcium (VNCa) reconstruction for coronary artery stenosis evaluation using photon-counting computed tomography (PC-CT). METHODS: One vessel phantom (4-mm diameter) containing solid calcified lesions with 25% and 50% stenoses inside a thorax phantom with motion simulation underwent PC-CT using UHR (0.2-mm slice thickness) and SR (0.6-mm slice thickness) at heart rates of 60 beats per minute (bpm), 80 bpm, and 100 bpm. A paired t-test or Wilcoxon test with Bonferroni correction was used. RESULTS: For 50% stenosis, differences in percent mean diameter stenosis between UHR and SR at 60 bpm (51.0 vs 60.3), 80 bpm (51.7 vs 59.6), and 100 bpm (53.7 vs 59.0) (p ≤ 0.011), as well as between VNCa and SR at 60 bpm (50.6 vs 60.3), 80 bpm (51.5 vs 59.6), and 100 bpm (53.7 vs 59.0) were significant (p ≤ 0.011), while differences between UHR and VNCa at all heart rates (p ≥ 0.327) were not significant. For 25% stenosis, differences between UHR and SR at 60 bpm (28.0 vs 33.7), 80 bpm (28.4 vs 34.3), and VNCa vs SR at 60 bpm (29.1 vs 33.7) were significant (p ≤ 0.015), while differences for UHR vs SR at 100 bpm (29.9 vs 34.0), as well as for VNCa vs SR at 80 bpm (30.7 vs 34.3) and 100 bpm (33.1 vs 34.0) were not significant (p ≥ 0.028). CONCLUSION: Stenosis quantification accuracy with PC-CT improved using either UHR acquisition or VNCa reconstruction. RELEVANCE STATEMENT: PC-CT offers to scan with UHR mode and the reconstruction of VNCa images both of them could provide improved coronary stenosis quantification at increased heart rates, allowing a more accurate stenosis grading at low and high heart rates compared to SR. KEY POINTS: Evaluation of coronary stenosis with conventional CT is challenging at high heart rates. PC-CT allows for scanning with ECG-gated UHR and SR modes. UHR and VNCa images were compared in a dynamic phantom. UHR improves stenosis quantification up to 100 bpm. VNCa reconstruction improves stenosis evaluation up to 80 bpm.
Asunto(s)
Algoritmos , Estenosis Coronaria , Fantasmas de Imagen , Tomografía Computarizada por Rayos X , Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Humanos , Fotones , Procesamiento de Imagen Asistido por Computador/métodosRESUMEN
BACKGROUND: Affective temperaments are documented predictors of psychopathology, but cumulating data suggest their relationship with coronary artery disease (CAD). We aimed to evaluate their role in relation to surrogate semiquantitative markers of coronary plaque burden, as assessed by coronary CT angiography (CCTA). METHODS: We included 351 patients who were referred for CCTA due to suspected CAD. All patients completed the Temperament Evaluation of Memphis, Pisa, Paris and San Diego Autoquestionnaire (TEMPS-A). The severity and extent of CAD was evaluated by CCTA, applying semiquantitative plaque burden scores, notably Segment Involvement Score (SIS) and Segment Stenosis Score (SSS). Logistic regression analyses were performed to define the predictors of CAD severity and extent. RESULTS: Regarding the scores evaluated by TEMPS-A that consists of 110 questions, in men, significant inverse association was found between hyperthymic temperament score and SSS (ß = -0.143, (95%CI: -0.091 to -0.004), p = 0.034). Compared to the TEMPS-A form, applying the abbreviated version - containing 40 questions - significant relationship between affective temperaments and SSS or SIS was found in case of both sexes. Concerning men, hyperthymic temperament was demonstrated to be independent predictor of both SSS (ß = -0.193, (95%CI: -0.224 to -0.048), p = 0.004) and SIS (ß = -0.194, (95%CI: -0.202 to -0.038), p = 0.004). Additionally, we proved, that significant positive association between irritable temperament and SSS (ß = 0.152, (95%CI: 0.002 to 0.269), p = 0.047) and SIS (ß = 0.155, (95%CI: 0.004 to 0.221), p = 0.042) exists among women. LIMITATIONS: Cross-sectional analysis of a single center study with self-reported questionnaires. CONCLUSIONS: Assessment of affective temperaments could offer added value in stratifying cardiovascular risk for patients beyond traditional risk factors.
Asunto(s)
Angiografía por Tomografía Computarizada , Enfermedad de la Arteria Coronaria , Índice de Severidad de la Enfermedad , Temperamento , Humanos , Masculino , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/psicología , Persona de Mediana Edad , Anciano , Angiografía Coronaria , AfectoRESUMEN
BACKGROUND: Coronary computed tomography angiography (CCTA) offers non-invasive diagnostics of the coronary arteries. Vessel evaluation requires the administration of intravenous contrast. The purpose of this study was to evaluate the utility of gadolinium-based contrast agent (GBCA) as an alternative to iodinated contrast for CCTA on a first-generation clinical dual-source photon-counting-detector (PCD)-CT system. METHODS: A dynamic circulating phantom containing a three-dimensional-printed model of the thoracic aorta and the coronary arteries were used to evaluate injection protocols using gadopentetate dimeglumine at 50%, 100%, 150%, and 200% of the maximum approved clinical dose (0.3 mmol/kg). Virtual monoenergetic image (VMI) reconstructions ranging from 40 keV to 100 keV with 5 keV increments were generated on a PCD-CT. Contrast-to-noise ratio (CNR) was calculated from attenuations measured in the aorta and coronary arteries and noise measured in the background tissue. Attenuation of at least 350 HU was deemed as diagnostic. RESULTS: The highest coronary attenuation (441 ± 23 HU, mean ± standard deviation) and CNR (29.5 ± 1.5) was achieved at 40 keV and at the highest GBCA dose (200%). There was a systematic decline of attenuation and CNR with higher keV reconstructions and lower GBCA doses. Only reconstructions at 40 and 45 keV at 200% and 40 keV at 150% GBCA dose demonstrated sufficient attenuation above 350 HU. CONCLUSION: Current PCD-CT protocols and settings are unsuitable for the use of GBCA for CCTA at clinically approved doses. Future advances to the PCD-CT system including a 4-threshold mode, as well as multi-material decomposition may add new opportunities for k-edge imaging of GBCA. RELEVANCE STATEMENT: Patients allergic to iodine-based contrast media and the future of multicontrast CT examinations would benefit greatly from alternative contrast media, but the utility of GBCA for coronary photon-counting-dector-CT angiography remains limited without further optimization of protocols and scanner settings. KEY POINTS: GBCA-enhanced coronary PCD-CT angiography is not feasible at clinically approved doses. GBCAs have potential applications for the visualization of larger vessels, such as the aorta, on PCD-CT angiography. Higher GBCA doses and lower keV reconstructions achieved higher attenuation values and CNR.
Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste , Angiografía Coronaria , Fantasmas de Imagen , Angiografía por Tomografía Computarizada/métodos , Medios de Contraste/administración & dosificación , Angiografía Coronaria/métodos , Humanos , Fotones , Gadolinio DTPA/administración & dosificaciónRESUMEN
BACKGROUND: We sought to compare the degree of maximal stenosis and the rate of invasive coronary angiography (ICA) recommendations in patients who underwent coronary CT angiography (CCTA) with photon-counting detector CT (PCD-CT) versus those who underwent CCTA with whole heart coverage energy-integrating detector CT (EID-CT). METHODS: In our retrospective single-center study, we included consecutive patients with suspected CAD who underwent CCTA performed with either PCD-CT or a 280-slice EID-CT. The degree of coronary stenosis was classified as no CAD, minimal (1-24 â%), mild (25-49 â%), moderate (50-69 â%), severe stenosis (70-99 â%), or occlusion. RESULTS: A total of 812 consecutive patients were included in the analysis, 401 patients scanned with EID-CT and 411 patients with PCD-CT (mean age: 58.4 â± â12.4 years, 45.4 â% female). Despite the higher total coronary artery calcium score (CACS) in the PCD-CT group (10 [interquartile range (IQR) â= â0-152.8] vs 1 [IQR â= â0-94], p â< â0.001), obstructive CAD was more frequently reported in the EID-CT vs PCD-CT group (no CAD: 28.7 â% vs 26.0 â%, minimal: 23.2 â% vs 30.9 â%, mild: 19.7 â% vs 23.4 â%, moderate: 14.5 â% vs 9.7 â%, severe: 11.5 â% vs 8.5 â% and occlusion: 2.5 â% vs 1.5 â%, respectively, p â= â0.025). EID-CT was independently associated with downstream ICA (OR â= â2.76 [95%CI â= â1.58-4.97] p â< â0.001) in the overall patient population, in patients with CACS<400 (OR â= â2.18 [95%CI â= â1.13-4.39] p â= â0.024) and in patients with CACS≥400 (OR â= â3.83 [95%CI â= â1.42-11.05] p â= â0.010). CONCLUSION: In patients who underwent CCTA with PCD-CT the number of subsequent ICAs was lower as compared to patients who were scanned with EID-CT. This difference was greater in patients with extensive coronary calcification.
Asunto(s)
Angiografía por Tomografía Computarizada , Tomografía Computarizada por Rayos X , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Angiografía Coronaria , Estudios Retrospectivos , Constricción Patológica , Estudios Prospectivos , Valor Predictivo de las Pruebas , Derivación y Consulta , Fantasmas de ImagenRESUMEN
BACKGROUND: Coronary computed tomography angiography (CCTA)-based fractional flow reserve (CT-FFR) allows for noninvasive determination of the functional severity of anatomic lesions in patients with coronary artery disease. The aim of this study was to intra-individually compare CT-FFR between photon-counting detector (PCD) and conventional energy-integrating detector (EID) CT systems. METHODS: In this single-center prospective study, subjects who underwent clinically indicated CCTA on an EID-CT system were recruited for a research CCTA on PCD-CT within 30 days. Image reconstruction settings were matched as closely as possible between EID-CT (Bv36 kernel, iterative reconstruction strength level 3, slice thickness 0.5 mm) and PCD-CT (Bv36 kernel, quantum iterative reconstruction level 3, virtual monoenergetic level 55 keV, slice thickness 0.6 mm). CT-FFR was measured semi-automatically using a prototype on-site machine learning algorithm by two readers. CT-FFR analysis was performed per-patient and per-vessel, and a CT-FFR ≤ 0.75 was considered hemodynamically significant. RESULTS: A total of 22 patients (63.3 ± 9.2 years; 7 women) were included. Median time between EID-CT and PCD-CT was 5.5 days. Comparison of CT-FFR values showed no significant difference and strong agreement between EID-CT and PCD-CT in the per-vessel analysis (0.88 [0.74-0.94] vs. 0.87 [0.76-0.93], P = 0.096, mean bias 0.02, limits of agreement [LoA] -0.14/0.19, r = 0.83, ICC = 0.92), and in the per-patient analysis (0.81 [0.60-0.86] vs. 0.76 [0.64-0.86], P = 0.768, mean bias 0.02, LoA -0.15/0.19, r = 0.90, ICC = 0.93). All included patients were classified into the same category (CT-FFR > 0.75 vs ≤0.75) with both CT systems. CONCLUSIONS: CT-FFR evaluation is feasible with PCD-CT and it shows a strong agreement with EID-CT-based evaluation when images are similarly reconstructed.
Asunto(s)
Angiografía por Tomografía Computarizada , Reserva del Flujo Fraccional Miocárdico , Humanos , Femenino , Angiografía por Tomografía Computarizada/métodos , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Angiografía Coronaria/métodos , Fantasmas de ImagenRESUMEN
PURPOSE: To evaluate the feasibility of CT angiography-derived fractional flow reserve (CT-FFR) calculations on ultrahigh-resolution (UHR) photon-counting detector (PCD)-CT series and to intra-individually compare the results with energy-integrating (EID)-CT measurements. METHOD: Prospective patients with calcified plaques detected on EID-CT between April 1st, 2023 and January 31st, 2024 were recruited for a UHR CCTA on PCD-CT within 30 days. PCD-CT was performed using the same or a lower CT dose index and an equivalent volume of contrast media. An on-site machine learning algorithm was used to obtain CT-FFR values on a per-vessel and per-patient basis. For all analyses, CT-FFR values ≤ 0.80 were deemed to be hemodynamically significant. RESULTS: A total of 34 patients (age: 67.3 ± 6.6 years, 7 women [20.6 %]) were included. Excellent inter-scanner agreement was noted for CT-FFR values in the per-vessel (ICC: 0.93 [0.90-0.95]) and per-patient (ICC: 0.94 [0.88-0.97]) analysis. PCD-CT-derived CT-FFR values proved to be higher compared to EID-CT values on both vessel (0.58 ± 0.23 vs. 0.55 ± 0.23, p < 0.001) and patient levels (0.73 ± 0.23 vs. 0.70 ± 0.22, p < 0.001). Two patients (5.9 %) with hemodynamically significant lesions on EID-CT were reclassified as non-significant on PCD-CT. All remaining participants were classified into the same category with both scanner systems. CONCLUSIONS: While UHR CT-FFR values demonstrate excellent agreement with EID-CT measurements, PCD-CT produces higher CT-FFR values that could contribute to a reclassification of hemodynamic significance.
RESUMEN
BACKGROUND: A recent simulation study proposed that stenosis measurements on coronary computed tomography (CT) angiography are influenced by the improved spatial resolution of photon-counting detector (PCD)-CT. The aim of the current study was to evaluate the impact of ultrahigh-spatial-resolution (UHR) on coronary stenosis measurements and Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification rates in patients undergoing coronary CT angiography on both PCD-CT and energy-integrating detector (EID)-CT and to compare measurements against quantitative coronary angiography. METHODS: Patients with coronary calcification on EID-CT (collimation, 192×0.6 mm) were prospectively enrolled for a research coronary CT angiography with UHR PCD-CT (collimation, 120×0.2 mm) within 30 days (between April 1, 2023 and January 31, 2024). PCD-CT was acquired with the same or lower CT dose index and equivalent contrast media volume as EID-CT. Percentage diameter stenosis (PDS) for calcified, partially calcified, and noncalcified lesions were compared between scanners. Patient-level reclassification rates for CAD-RADS were evaluated. The accuracy of PDS measurements was validated against quantitative coronary angiography in patients who underwent invasive coronary angiography. RESULTS: In total, PDS of 278 plaques were quantified in 49 patients (calcified, 202; partially calcified, 51; noncalcified, 25). PCD-CT-based PDS values were lower than EID-CT measurements for calcified (45.1±20.7 versus 54.6±19.2%; P<0.001) and partially calcified plaques (44.3±19.6 versus 54.9±20.0%; P<0.001), without significant differences for noncalcified lesions (39.1±15.2 versus 39.0±16.0%; P=0.98). The reduction in stenosis degrees led to a 49.0% (24/49) reclassification rate to a lower CAD-RADS with PCD-CT. In a subset of 12 patients with 56 lesions, UHR-based PDS values showed higher agreement with quantitative coronary angiography (mean difference, 7.3%; limits of agreement, -10.7%/25.2%) than EID-CT measurements (mean difference, 17.4%; limits of agreement, -6.9%/41.7%). CONCLUSIONS: Compared with conventional EID-CT, UHR PCD-CT results in lower PDS values and more accurate stenosis measurements in coronary plaques with calcified components and leads to a substantial Coronary Artery Disease Reporting and Data System reclassification rate in 49.0% of patients.