1.
Ann Thorac Surg ; 105(4): e185-e187, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29329990

RESUMEN

Performing transcatheter aortic valve implantation in the presence of aneurysmatic aortopathy is widely contraindicated but needs to be taken into account as a bailout strategy in selected patients. Deliberate preoperative assessment of measurements becomes the crucial key element in this context. After meticulous valve selection, retrograde access is obtained through the right subclavian artery additionally serving as a backup arterial cannulation site in case of conversion. Transcatheter aortic valve implantation is then performed through the transapical route. Transcatheter aortic valve implantation in complex aneurysmatic aortic morphology is feasible in highly selected patients after comprehensive preoperative evaluation. The present article describes our initial experience, safeguards, and technical details.


Asunto(s)
Aneurisma de la Aorta/complicaciones , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Humanos
2.
Ann Thorac Surg ; 101(1): 100-8, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26443880

RESUMEN

BACKGROUND: The purpose of this study was to evaluate the safety and performance of the Freedom Solo valve in aortic valve replacement by clinical and hemodynamic outcomes. METHODS: Six hundred sixteen patients underwent aortic valve replacement in 18 European centers; mean age was 74.5 ± 5.9 years, 54.1% of the patients were male, and concomitant procedures were performed in 43.2% of the patients. The majority (69%) of the implanted sizes were 23 mm and 25 mm. RESULTS: At 1 year, overall survival was 94.0%, whereas freedom from valve-related death was 98.6%. There were 9 (1.5%) early (≤ 30 days) and 27 (4.4%) late (>30 days) deaths. Early and late valve-related mortality was 0.3% (n = 2) and 1.1% (n = 7), respectively. Freedom from explant was 97.6%; 10 valves were explanted for endocarditis and 4 for paravalvular leak. There were 10 (1.6%) early and 5 (0.8%) late strokes. Atrioventricular block requiring pacemaker implant occurred in 8 (1.3%) and 1 (0.2%) patients in the early and late postoperative period, respectively. Thrombocytopenia was seen in 27 cases (4.4%) in the early postoperative period. Preoperatively, 93.8% of patients were in New York Heart Association functional classes II through IV, whereas at 1 year 96.9% of patients were in New York Heart Association functional classes I and II. At 1-year follow-up, mean and peak pressure gradients were 7.2 and 14.6 mm Hg, respectively. Indexed left ventricular mass decreased by 12% from 138 g/m(2) at discharge to 122 g/m(2) at 1 year. CONCLUSIONS: At 1-year follow-up after Freedom Solo implantation, we found acceptable clinical results with low mortality and morbidity and good hemodynamic performance, confirming safety and effectiveness in this multicenter experience.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Ecocardiografía , Europa (Continente)/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
3.
Ann Thorac Surg ; 98(4): 1301-7, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25149050

RESUMEN

BACKGROUND: The Sorin Freedom SOLO (FS) bovine pericardial stentless valve prosthesis is designed for supraannular, subcoronary implantation. We report our experience and results with 277 consecutively implanted FS bioprostheses. METHODS: 277 patients (mean age, 74.2 ± 7.3 years; 139 (50.2%) female) underwent aortic valve replacement (AVR) with the FS stentless bioprosthesis. The hemodynamic performance was investigated with transthoracic echocardiography at discharge, 6 months later, and yearly thereafter. Follow-up was 100% complete, with an average observation time of 2.6 ± 1.7 years and a total of 697.3 patient-years. RESULTS: The overall 30-day mortality was 4.3%. The mortalities for isolated AVR and combined procedures were 1.9% and 7.3%, respectively. No causes of death were valve-related. Preoperative peak (74.2 ± 23.0 mm Hg) and mean (48.6 ± 16.3 mm Hg) gradients decreased to 15.6 ± 5.4 mm Hg and 8.8 ± 3.0 mm Hg postoperatively and remained unchanged for as long as 5 years. The postoperative mean effective orifice area (EOA) for valve sizes 19, 21, 23, 25, and 27 were 1.49 ± 0.32 cm(2), 1.67 ± 0.40 cm(2), 1.92 ± 0.38 cm(2), 2.01 ± 0.42 cm(2), and 2.13 ± 0.36 cm(2), respectively. Severe prosthesis-patient mismach (PPM) was completely absent, and moderate PPM occurred in 17 patients (6.1%). In isolated AVR, 0.8% of patients with preoperative sinus rhythm required a permanent pacemaker before hospital discharge. There was 100% freedom from structural valve deterioration, 99.6 % freedom from endocarditis and reoperation, and 97.3% freedom from thromboembolism at 5 years. CONCLUSIONS: The FS stentless aortic valve is safe to implant, and it shows excellent hemodynamic performance and early and midterm results. Owing to the favorable EOA, the valve appears particularly attractive for patients at risk for PPM.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Animales , Bovinos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS