Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Int J Cardiol ; 349: 31-38, 2022 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-34843819

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is safe and feasible in patients with bicuspid aortic valve (BAV), but whether annular size may influence TAVR results in BAV patients remains unclear. We aimed at evaluating the impact of aortic annular size on procedural and clinical outcomes of BAV patients undergoing TAVR, as well as potential interactions between annular dimension and trans-catheter heart valve (THV) type (balloon-expandable (BEV) vs. self-expanding (SEV). METHODS: BEAT is a multicenter registry of consecutive BAV stenosis undergoing TAVR. For this sub-study patients were classified according to annular dimension in small-annulus (area < 400 mm2 or perimeter <72 mm), medium-annulus (area ≥ 400 and < 575 mm2, perimeter ≥72 mm and< 85 mm), large-annulus (area ≥ 575 mm2 or perimeter ≥85 mm). Primary endpoint was Valve Academic Research Consortium-2 (VARC-2) device success. RESULTS: 45(15.5%) patients had small, 132(45.3%) medium, and 114(39.2%) large annuli. Compared with other groups, patients with large annuli were more frequently male, younger, with higher body mass index, larger aortic valve area, higher rate of moderate-severe calcification, lower mean trans-aortic valve gradient and lower left ventricular ejection fraction. In large-annuli SEVs were associated with a lower VARC-2 device success (75.9% vs. 90.6%, p = 0.049) driven by a higher rate of paravalvular valvular leak (PVL) compared to BEVs (20.7% vs. 1.2%, p < 0.001). However, no differences in clinical outcomes were observed according to annular size nor THV type. CONCLUSIONS: TAVR in BAV patients is feasible irrespective of annular size. However in patients with large aortic annulus SEVs were associated with a significantly higher rate of PVLs compared to BEVs.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Catéteres , Constricción Patológica , Humanos , Masculino , Diseño de Prótesis , Sistema de Registros , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
2.
Int J Cardiol ; 325: 109-114, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-33148461

RESUMEN

BACKGROUND: Although bicuspid aortic valve (BAV) is not considered a "sweet spot" to trans-catheter aortic valve replacement (TAVR), a certain number of BAV underwent TAVR. Whether BAV phenotype affects outcomes following TAVR remains debated. We aimed at evaluating the impact of BAV phenotype on procedural and clinical outcomes after TAVR using new generation trans-catheter heart valves (THVs). METHODS: patients included in the BEAT registry were classified according to the BAV phenotype revealed at multi-slice computed tomography (MSCT) in type 0 (no raphe) vs. type 1 (1 raphe). Primary end-point was Valve Academic Research Consortium-2 (VARC-2) device success. Secondary end-points included procedural complications, rate of permanent pacemaker implantation, clinical outcomes at 30-day and 1-year. RESULTS: Type 0 BAV was present in 25(7.1%) cases, type 1 in 218(61.8%). Baseline characteristics were well balanced between groups. Moderate-severe aortic valve calcifications at MSCT were less frequently present in type 0 vs. type 1 (52%vs.71.1%,p = 0.05). No differences were reported for THV type, size, pre and post-dilation between groups. VARC-2 success tended to be lower in type 0 vs. type 1 BAV (72%vs86.7%;p = 0.07). Higher rate of mean transprosthetic gradient ≥20 mmHg was observed in type 0 vs. type 1 group (24%vs6%,p = 0.007). No differences were reported in the rate of post-TAVR moderate-severe aortic regurgitation and clinical outcomes between groups. CONCLUSIONS: Our study confirms TAVR feasibility in both BAV types, however a trend toward a lower VARC-2 device success and a higher rate of mean transprosthetic gradient ≥20 mmHg was observed in type 0 vs. type 1 BAV.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Catéteres , Constricción Patológica , Humanos , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Clin Res Cardiol ; 110(5): 667-675, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33389062

RESUMEN

OBJECTIVES: To define the incidence of high residual gradient (HRG) after transcatheter aortic valve replacement (TAVR) in BAVs and their impact on short term outcome and 1-year mortality. BACKGROUND: Transcatheter heart valves (THVs) offer good performance in tricuspid aortic valves with low rate of HRG. However, data regarding their performance in bicuspid aortic valves (BAV) are still lacking. METHODS: The BEAT (Balloon vs Self-Expandable valve for the treatment of bicuspid Aortic valve sTenosis) registry included 353 consecutive patients who underwent TAVR (Evolut R/PRO or Sapien 3 valves) in BAV between June 2013 and October 2018. The primary endpoint was device unsuccess with post-procedural HRG (mean gradient ≥ 20 mmHg). The secondary endpoint was to identify the predictors of HRG following the procedure. RESULTS: Twenty patients (5.6%) showed HRG after TAVR. Patients with HRG presented higher body mass index (BMI) (30.7 ± 9.3 vs. 25.9 ± 4.8; p < 0.0001) and higher baseline aortic mean gradients (57.6 ± 13.4 mmHg vs. 47.7 ± 16.6, p = 0.013) and more often presented with BAV of Sievers type 0 than patients without HRG. At multivariate analysis, BMI [odds ratio (OR) 1.12; 95% confidence interval (CI) 1.05-1.20, p = 0.001] and BAV type 0 (OR 11.31, 95% CI 3.45-37.06, p < 0.0001) were confirmed as independent predictors of high gradient. CONCLUSION: HRG following TAVR in BAVs is not negligible and is higher among patients with high BMI and with BAV 0 anatomy.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/patología , Enfermedad de la Válvula Aórtica Bicúspide/patología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Mortalidad , Sistema de Registros , Resultado del Tratamiento
4.
EuroIntervention ; 16(4): e328-e334, 2020 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-31746743

RESUMEN

AIMS: Treatment of in-stent restenosis of coronary stents is challenging. The use of drug-coated balloons (DCB) is a promising technique to treat in-stent restenosis without adding another metal layer. The aim of the AGENT ISR randomised trial is to evaluate angiographic and clinical outcomes in patients with ISR of a previously treated lesion who were treated with either a DCB with a new coating formulation (Agent) or a standard DCB (SeQuent Please). METHODS AND RESULTS: AGENT ISR is a multicentre, randomised, open-label, non-inferiority study comparing the Agent and SeQuent Please DCB. A total of 125 patients (mean age ~68 years, 18% female) with in-stent restenosis of a previously treated lesion <28 mm in length were randomised at 11 sites in Europe to Agent (n=65) or SeQuent Please (n=60). The primary endpoint, six-month in-stent late lumen loss, in the Agent group (0.397±0.43 mm [n=51]) was non-inferior to that of the SeQuent Please group (0.393±0.536 mm [n=49]), as the two-sided upper 95% confidence boundary for the difference between groups was less than the pre-specified non-inferiority margin of 0.20 (difference 0.004, 95% CI [-0.189, 0.196]; pnon-inferiority=0.046). At one year, mortality was 3.1% in Agent and 1.7% in SeQuent Please patients (p>0.99), target lesion revascularisation 7.7% versus 10.0% (p=0.89), and stent thrombosis 0% versus 3.3% (p=0.44). Similar improvements in quality of life were seen in the two groups. CONCLUSIONS: In this head-to-head comparison of two DCB, Agent proved to be non-inferior to SeQuent Please for in-stent late lumen loss at six months. CLINICAL TRIALS REGISTRATION: NCT02151812 (http://clinicaltrials.gov/).


Asunto(s)
Angioplastia Coronaria con Balón , Fármacos Cardiovasculares/uso terapéutico , Reestenosis Coronaria/cirugía , Stents Liberadores de Fármacos , Paclitaxel/uso terapéutico , Anciano , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Femenino , Humanos , Masculino , Calidad de Vida , Resultado del Tratamiento
5.
Circ Cardiovasc Interv ; 13(7): e008714, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32646304

RESUMEN

BACKGROUND: Large data comparing the performance of new-generation self-expandable versus balloon-expandable transcatheter heart valves in bicuspid aortic stenosis are lacking. We aim to compare the safety and performance of balloon-expandable and self-expandable transcatheter heart valves in the treatment of bicuspid aortic stenosis. METHODS: The BEAT (balloon versus self-expandable valve for the treatment of bicuspid aortic valve stenosis) registry included 353 consecutive patients who underwent transcatheter aortic valve implantation using new-generation Evolut R/PRO or Sapien 3 valves in bicuspid aortic valve. RESULTS: A total of 353 patients (n=242 [68.6%] treated with Sapien 3 and n=111 [68.6%] treated with Evolut R (n=70)/PRO [n=41]) were included. Mean age was 77.8±8.3 years and mean Society of Thoracic Surgeons Predicted Risk of Mortality was 4.4±3.3%. Valve Academic Research Consortium-2 device success was similar between Sapien 3 and Evolut R/PRO (85.6% versus 87.2%; P=0.68). In the Sapien 3 group, 4 patients experienced annular rupture whereas this complication did not occur in the Evolut R/PRO group. After propensity score matching, Valve Academic Research Consortium-2 device success was similar between both groups (Sapien 3=85.7% versus Evolut R/Pro=84.4%; P=0.821). Both in the overall and in the matched population, no differences in the rate of permanent pacemaker implant were observed. At 1-year follow-up, the rate of overall death and cardiovascular death were similar between the 2 groups. In the unmatched population, the 1-year echocardiographic follow-up demonstrated similar rate of moderate-to-severe paravalvular aortic regurgitation (Evolut R/PRO 10.5% versus Sapien 3 4.2%, P=0.077); however, after propensity matching, the rate of moderate-to-severe paravalvular leak became significantly higher among patients treated with self-expandable valves (9.3% versus 0%; P=0.043). CONCLUSIONS: Our study confirms the feasibility of both Sapien 3 and Evolut R/PRO implantation in bicuspid aortic valve anatomy; a higher rate of moderate-severe paravalvular aortic regurgitation was observed in the Evolut R/PRO group at 1-year follow-up in the matched cohort, although patients treated with balloon-expandable valve had a higher rate of annular rupture.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Europa (Continente) , Estudios de Factibilidad , Femenino , Hemodinámica , Humanos , Masculino , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
6.
EuroIntervention ; 14(4): e397-e404, 2018 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-29688174

RESUMEN

AIMS: Transcatheter valve-in-valve implantation (VinV) is established for the treatment of degenerated surgical bioprostheses in patients at high operative risk. Our aim was to report on the first large assessment of VinV with next-generation balloon-expandable transcatheter heart valves. METHODS AND RESULTS: After SAPIEN XT or SAPIEN 3 VinV, 514 patients were analysed using an inverse probability of treatment weighting. Standardised clinical and haemodynamic outcomes were compared, and core laboratory evaluation of implantation depth was performed. Thirty-day all-cause mortality was 0.6% and 3.5% for SAPIEN 3 and SAPIEN XT (p=0.077). Residual transprosthetic gradient ≥20 mmHg was observed in 38.3% (SAPIEN 3) and 35.7% (SAPIEN XT) of patients (p=0.627) with increased rates in small bioprostheses (≤21 mm true ID). In SAPIEN 3 VinV, low implantation depth >20% THV stent frame length was associated with a higher rate of elevated transaortic gradients (p=0.048). Similarly, an implantation depth >5 mm was linked to more pacemaker implantations (p=0.01). Overall, a trend towards higher pacemaker implantation rates was observed after SAPIEN 3 VinV (6% vs. 2.5% in SAPIEN XT, p=0.071). CONCLUSIONS: Transcatheter aortic VinV with the balloon-expandable SAPIEN XT or SAPIEN 3 was similarly safe and effective. However, residual stenosis remains a concern, particularly in smaller bioprostheses and with increasing implantation depth.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica , Humanos , Diseño de Prótesis , Resultado del Tratamiento
7.
EuroIntervention ; 13(11): 1311-1318, 2017 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-28829745

RESUMEN

AIMS: The aim of this study was to analyse the procedural results and midterm safety of everolimus-eluting bioresorbable vascular scaffolds (BVS) used for percutaneous coronary intervention in a large all-comers cohort from the German-Austrian ABSORB RegIstRy (GABI-R). METHODS AND RESULTS: A total of 3,231 patients were included in this prospective, observational, multicentre study (ClinicalTrials.gov NCT02066623) of consecutive patients undergoing BVS implantation between November 2013 and January 2016. Endpoints were major adverse cardiac events (MACE; a composite endpoint of death, target vessel revascularisation, and myocardial infarction), and target lesion failure (TLF; a composite endpoint of cardiac death, target vessel myocardial infarction, and target lesion revascularisation). Scaffold thrombosis was a further endpoint. Of all patients, 51.5% presented with acute coronary syndrome. Predilatation and post-dilatation were performed in 91.5% and 71.9% of patients, respectively. Procedural success was 98.9%. After six months, the incidence of MACE was 4.1% and of TLF 2.4%. The rate of target vessel MI was 1.5%, and target lesion revascularisation was performed in 1.8%. Definite/ probable scaffold thrombosis was documented in 1.4% of patients. CONCLUSIONS: GABI-R, the largest registry to provide data regarding safety after BVS implantation in a real-world setting, reveals high procedural success and low six-month event rates.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Everolimus/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Austria/epidemiología , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Trombosis Coronaria/mortalidad , Everolimus/efectos adversos , Femenino , Alemania/epidemiología , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
8.
EuroIntervention ; 13(11): 1319-1326, 2017 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-28649953

RESUMEN

AIMS: The aim of this study was to assess clinical restenosis and its predictors after implantation of bioresorbable vascular scaffolds (BVS) in everyday practice in the large-scale German-Austrian ABSORB Registry (GABI-R). METHODS AND RESULTS: Between November 2013 and January 2016, 3,264 patients underwent BVS implantation in the 93 centres of GABI-R. At six-month follow-up, 24 patients experienced clinically indicated target lesion revascularisation (cTLR) unrelated to BVS thrombosis (cumulative incidence 0.76%; angiographically, 58.3% of in-BVS restenosis of focal pattern). Compared to patients without cTLR, patients with cTLR had more lesions per patient (1.83±1.0 vs. 1.36±0.7), complex (52.3% vs. 36.2%) and mild-to-moderately calcified lesions (65.9% vs. 60.5%) treated, and more frequently had overlapping BVS (22.2% vs. 10.8%), all p<0.05. Implanted BVS length was 40.0 mm (28.0, 46.9) vs. 23.0 mm (18.0, 30.0), p<0.001, remaining in the multivariable analysis the only independent predictor of cTLR (hazard ratio 1.02, 95% CI: 1.01-1.04, p<0.001). The myocardial infarction rate was also significantly higher among patients with cTLR, 29.2% vs. 1.7%, p<0.0001. CONCLUSIONS: cTLR related to BVS restenosis at six months after BVS implantation is a rare event depending on implanted BVS length. Whether cTLR increases the myocardial infarction risk needs to be evaluated at longer-term follow-up and within the setting of adequately powered randomised trials.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/epidemiología , Everolimus/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Austria/epidemiología , Fármacos Cardiovasculares/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/mortalidad , Trombosis Coronaria/epidemiología , Trombosis Coronaria/mortalidad , Everolimus/efectos adversos , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/mortalidad , Oportunidad Relativa , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA