Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 33(8): 1826-1836, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35748386

RESUMEN

INTRODUCTION: Left bundle branch area pacing (LBBAP) has recently been reported to be a new, clinically feasible and safe physiological pacing strategy. The present study aims to investigate the usefulness of LBBAP in reducing mechanical dyssynchrony compared with right ventricular septal pacing (RVSP). METHODS AND RESULTS: A total of 39 LBBAP patients, 42 RVSP patients, and 93 healthy control participants were retrospectively evaluated. We compared phase analysis- (bandwidth, phase standard deviation [PSD], entropy) and regional wall motion analysis parameters. Wall motion analysis parameters included the time to the end-systolic frame (TES) assessed using single-photon emission computed tomography analysis. The maximum differences between segmental TES (MDTES), the standard deviation of TES (SDTES), and the TES difference between the lateral and septal segments (DTES-LS) were obtained. All phase analysis parameters were significantly smaller in the LBBAP group than in the RVSP group (bandwidth: LBBAP, 74 ± 31° vs. RVSP, 102 ± 59°, p = .009; PSD: LBBAP, 19 ± 6.7° vs. RVSP, 26 ± 15°, p = .007; entropy: LBBAP, 0.57 ± 0.07 vs. RVSP, 0.62 ± 0.11 p = .009). The regional wall motion analysis parameters were also smaller in the LBBAP group than in the RVSP group (MDTES:LBBAP, 17 ± 7.1% vs. RVSP, 25 ± 14%, p = .004; SDTES:LBBAP, 4.5 ± 1.7% vs. RVSP, 6.0 ± 3.5%, p = .015; DTES-LS: LBBAP, 4.1 ± 3.4% vs. RVSP, 7.1 ± 5.4%, p = .004). All phase analysis and wall motion analysis parameters were same in the LBBAP and control groups. CONCLUSION: LBBAP may reduce mechanical dyssynchrony and achieve greater physiological ventricular activation than RVSP.


Asunto(s)
Fascículo Atrioventricular , Marcapaso Artificial , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Humanos , Imagen de Perfusión , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
2.
Europace ; 24(8): 1284-1290, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34919657

RESUMEN

AIMS: This study aimed to investigate the intraventricular blood flow pattern of patients with left bundle branch block (LBBB) using four-dimensional flow magnetic resonance imaging (4D-flow MRI). METHODS AND RESULTS: We performed 4D-flow MRI for 16 LBBB patients (LBBB group) and 16 propensity score-matched patients with a normal QRS duration (non-LBBB group). The energy loss (EL) in the left ventricle was evaluated. In both groups, blood flow from the mitral valve to the apex of the heart and left ventricular (LV) outflow tract during LV diastole were observed. Vortices were also observed in both groups. There were two patterns of vortices: unidirectional clockwise rotation and counterclockwise rotation taking place from the mid-diastole to the systole (reverse pattern). The reverse pattern was observed significantly more frequently in the LBBB group (LBBB 94% vs. non-LBBB 19%, P < 0.001). The interobserver agreement for the streamline analysis was good (kappa = 0.68). The maximum EL was significantly higher in the LBBB group [LBBB 12 (11-15) mW vs. non-LBBB 8.0 (6.2-9.7) mW, P < 0.001]. CONCLUSION: Left bundle branch block patients may suffer from inefficient LV haemodynamics reflected by non-physiological counterclockwise vortices and increased EL. Thus, the shape of the vortices and EL in the left ventricle can serve as markers of LV mechanical dyssynchrony in LBBB patients and could be investigated as predictors of response to cardiac resynchronization therapy.


Asunto(s)
Terapia de Resincronización Cardíaca , Disfunción Ventricular Izquierda , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Ventrículos Cardíacos , Humanos , Imagen por Resonancia Magnética , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Función Ventricular Izquierda
3.
Ann Noninvasive Electrocardiol ; 27(6): e13000, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35972827

RESUMEN

INTRODUCTION: Conventional Doppler measurements have limitations in predicting left ventricular diastolic dysfunction (LVDD) in patients with mitral regurgitation (MR). Recently, electrocardiographic P-wave peak time (PWPT) has been proposed as a parameter of detecting LVDD. This study aimed to evaluate the association between PWPT and left ventricular end-diastolic pressure (LVEDP) in patients with MR. METHODS: We performed echocardiography and cardiac catheterization in 82 patients with moderate or severe MR. We classified patients into two groups: low LVEDP group (L-LVEDP) (LVEDP <16 mmHg, n = 40) and high LVEDP group (H-LVEDP) (LVEDP ≥16 mmHg, n = 42). We evaluated LVDD and PWPT based on echocardiographic and electrocardiographic findings in both groups. RESULTS: The PWPT in lead II (PWPTII ) was significantly longer in patients in the H-LVEDP group than in those in the L-LVEDP group (67 vs. 47 ms, p < .001). Using correlation analysis, LVEDP was positively correlated with PWPTII (r = .577, p < .001). Using multivariate analysis, PWPTII was found to be an independent predictor of increased LVEDP (95% CI: 0.1030-0.110; p < .001). Using receiver operating characteristic (ROC) curve analysis, the optimal cutoff value of PWPTII for predicting elevated LVEDP was 58.9 ms, with a sensitivity of 80.0% and a specificity of 73.8% (area under curve: 0.809, 95% CI: 0.713-0.905). CONCLUSION: To the best of our knowledge, this is the first study to assess the effect of a significant valvular disease on PWPT in lead II. These findings suggest that prolonged PWPTII may be an independent predictor of increased LVEDP in patients with moderate or severe MR.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Electrocardiografía , Ecocardiografía , Cateterismo Cardíaco , Análisis Multivariante
4.
Heart Vessels ; 36(8): 1166-1174, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33725163

RESUMEN

Cardiac implantable electronic devices (CIEDs) offer heart failure (HF) diagnostic information, including intrathoracic impedance (ITI) or physical activity (PA). However, few studies have evaluated the utility of these parameters measured by CIEDs with CorVue algorithm. The purpose of this study was to investigate the relationship between ITI alerts triggered by the CorVue algorithm and HF development. We also examined the association between device-measured PA and ITI alerts associated with HF development. We retrospectively studied consecutive patients with CIEDs equipped with CorVue algorithm, which were implanted between June 1, 2011 and August 31, 2019. These patients were divided into two groups: patients with decreased ITI followed by the ITI alerts (ITI alert group) and those without the alerts (non-ITI alert group). There were 35 and 14 patients in the ITI and non-ITI alert groups, respectively. A total of 96 ITI alerts were observed. ITI alerts associated with HF development were observed in 21% (20/96); whereas, ITI alerts not associated with HF development were observed in 79% (76/96). Accurate device-measured PA was confirmed in 76 ITI alerts, which consisted of 30 alerts with lower PA and 46 alerts without lower PA. ITI alerts associated with HF development were observed in 30% (9/30) of the alerts with lower PA, whereas observed only in 6.5% (3/46) of the alerts without lower PA. In conclusion, the CorVue ITI alerts indicated a high false-positive rate. However, device-measured PA may be useful to determine whether ITI alerts are associated with HF development or not, which was attributed to the high negative predictive value.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Cardiografía de Impedancia , Impedancia Eléctrica , Ejercicio Físico , Insuficiencia Cardíaca/diagnóstico , Humanos , Estudios Prospectivos , Estudios Retrospectivos
5.
Heart Vessels ; 36(7): 1056-1063, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33507356

RESUMEN

Right ventricular (RV) septum is an alternate site for the placement of RV lead tip instead of RV apex. Recent studies have demonstrated that less than half of the RV leads targeted for septal implantation are placed on the RV septum using a conventional stylet system; new guiding catheter systems have become available for RV lead placement. This study aimed to investigate the usefulness of the delivery catheter system in lead placement on the RV septum when compared with the stylet system. We retrospectively evaluated 198 patients who underwent fluoroscopically guided pacemaker implantation with RV leads targeted to be placed in the RV septum and in whom computed tomography was incidentally and subsequently performed. A delivery catheter was used in 16 patients, and a stylet in 182 patients. The primary endpoint of this study was the success rate of RV lead placement on the RV septum. The proportion of RV lead placement on the RV septum was higher in the delivery catheter group than in the stylet group (100% vs. 44%; p < 0.001). In the stylet group, the lead tips were placed at the hinge in 92 cases (51%) and on the free wall in 9 cases (5%). Paced QRS duration was narrower in the delivery catheter group than in the stylet group (128 ± 16 vs. 150 ± 21 ms, p < 0.01). The delivery catheter system designated for pacing leads may aid in selecting RV septal sites and achieve good physiologic ventricular activation.


Asunto(s)
Arritmias Cardíacas/terapia , Marcapaso Artificial/estadística & datos numéricos , Función Ventricular Derecha/fisiología , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Electrocardiografía/métodos , Diseño de Equipo , Femenino , Fluoroscopía/métodos , Estudios de Seguimiento , Ventrículos Cardíacos , Humanos , Masculino , Estudios Retrospectivos , Tabique Interventricular
6.
Heart Vessels ; 35(6): 817-824, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31897640

RESUMEN

Previous studies suggested that sleep-disordered breathing was associated with cardiovascular diseases such as heart failure (HF). Recently, algorithms of cardiac implantable electronic devices (CIEDs) have been developed to detect advanced sleep apnea (SA); the Apnea Scan (AP Scan) being an example. The purpose of this study was to investigate the association between respiratory disturbance index (RDI) measured using the AP Scan algorithm and HF development. We retrospectively studied consecutive patients with CIEDs equipped with the AP Scan algorithm which were implanted between December 1, 2011 and March 31, 2019. These patients were divided into 2 groups according to the trends of RDI: patients with a continually high RDI > 30 (severe SA group) and those without a continually high RDI (non-severe SA group). There were 16 and 46 patients in the severe and non-severe SA groups, respectively. Increased left ventricular end-diastolic and end-systolic dimensions were observed in the severe SA group. Regarding cardiovascular events, HF was observed in 8 patients (50.0%) in the severe SA group and 1 patient (2.2%) in the non-severe SA group; thus, there was a significantly higher proportion of patients with HF in the severe SA group. In conclusion, continually high RDI was associated with HF development in patients with CIEDs equipped with the AP Scan algorithm. Therefore, an elevated RDI may be a risk factor for the development of HF in patients with CIEDs.


Asunto(s)
Algoritmos , Cardiografía de Impedancia/instrumentación , Desfibriladores Implantables , Insuficiencia Cardíaca/etiología , Pulmón/fisiopatología , Marcapaso Artificial , Respiración , Procesamiento de Señales Asistido por Computador , Síndromes de la Apnea del Sueño/diagnóstico , Anciano , Anciano de 80 o más Años , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Síndromes de la Apnea del Sueño/complicaciones , Síndromes de la Apnea del Sueño/fisiopatología
7.
BMC Anesthesiol ; 20(1): 9, 2020 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-31910797

RESUMEN

BACKGROUND: The purpose of this study is to investigate if a laryngeal mask could improve respiratory condition during radiofrequency catheter ablation (RFCA). METHODS: Twenty-four consecutive patients who underwent RFCA for atrial fibrillation were divided into two groups (Facemask group; n = 10, Laryngeal mask group; n = 14). All patients were completely sedated under intravenous anesthesia and fitted with artificial respirators during the RFCA. The capnography waveforms and their differential coefficients were analyzed to evaluate the changes of end-tidal CO2 (ETCO2) values, respiratory intervals, expiratory durations, and inspiratory durations. RESULTS: During the RFCA, ETCO2 values of the laryngeal mask group were higher than those of the facemask group (36.0 vs. 29.2 mmHg, p = 0.005). The respiratory interval was significantly longer in the laryngeal mask group than those in the facemask group (4.28 s vs.5.25 s, p < 0.001). In both expiratory and inspiratory phases, the mean of the maximum and minimum values of CO2 was significantly higher when using a laryngeal mask than when using a facemask. The inspiratory-expiratory ratio of the laryngeal mask group was significantly larger than that of the facemask group (1.59 vs. 1.27, p < 0.001). The total procedure duration, fluoroscopic duration and the ablation energy were significantly lower in the laryngeal mask group than in the facemask group. The ETCO2 value is the most influential parameter on the fluoroscopic duration during the RFCA procedure (ß = - 0.477, p = 0.029). CONCLUSIONS: The use of a laryngeal mask could stabilize respiration during intravenous anesthesia, which could improve the efficiency of RFCA.


Asunto(s)
Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Máscaras Laríngeas , Máscaras , Respiración Artificial/métodos , Anciano , Fibrilación Atrial/diagnóstico por imagen , Dióxido de Carbono/sangre , Sedación Consciente , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad
8.
J Interv Cardiol ; 2019: 4532862, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31772532

RESUMEN

OBJECTIVES: To examine the influence of hydrostatic pressure on fractional flow reserve (FFR) in vivo. BACKGROUND: Systematic differences in FFR values have been observed previously in the left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA). It has been suggested that as the hydrostatic pressure variations caused by the height differences between the catheter tip (mean aortic pressure (Pa)) and pressure-wire sensor (mean distal intracoronary pressure (Pd)) are small, intracoronary pressure need not be corrected. METHODS: Resting Pd/Pa and FFR values in 23 patients (27 lesions) were measured and compared in supine and prone positions. These values were corrected by hydrostatic pressure influenced by height levels and compared. Height differences between Pa and Pd were calculated using coronary computed tomography angiographies. RESULTS: In LAD, resting Pd/Pa and FFR values were significantly higher in the prone position than in the supine position (0.97 ± 0.05 vs 0.89 ± 0.04, P < 0.001 (resting Pd/Pa); 0.81 ± 0.09 vs 0.72 ± 0.07, P < 0.001 (FFR)). Conversely, in LCX and RCA, these values were significantly lower in the prone position (LCX: 0.93 ± 0.03 vs 0.98 ± 0.03, P < 0.001 (resting Pd/Pa); 0.84 ± 0.05 vs 0.89 ± 0.04, P < 0.001 (FFR); RCA: 0.91 ± 0.04 vs 0.98 ± 0.03, P=0.005 (resting Pd/Pa); 0.78 ± 0.07 vs 0.84 ± 0.07, P=0.019 (FFR)). FFR values corrected by hydrostatic pressure showed good correlations in the supine and prone positions (R 2 = 0.948 in LAD; R 2 = 0.942 in LCX; R 2 = 0.928 in RCA). CONCLUSIONS: Hydrostatic pressure variations due to height levels influence intracoronary pressure measurements and largely affect resting Pd/Pa and FFR, which might have caused systematic differences in FFR values between the anterior and posterior coronary territories.


Asunto(s)
Circulación Coronaria/fisiología , Reserva del Flujo Fraccional Miocárdico/fisiología , Presión Hidrostática , Posición Prona/fisiología , Posición Supina/fisiología , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Estenosis Coronaria/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
9.
Circ J ; 83(9): 1901-1907, 2019 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-31308318

RESUMEN

BACKGROUND: Although previous studies have suggested a certain prevalence of Fabry disease (FD) in left ventricular hypertrophy (LVH) patients, the screening of FD is difficult because of its wide-ranging clinical phenotypes. We aimed to clarify the utility of combined measurement of plasma globotriaosylsphingosine (lyso-Gb3) concentration and α-galactosidase A activity (α-GAL) as a primary screening of FD in unexplained LVH patients.Methods and Results:Between 2014 and 2016, both lyso-Gb3 and α-GAL were measured in 277 consecutive patients (male 215, female 62, age 25-79 years) with left ventricular wall thickness >12 mm on echocardiogram: 5 patients (1.8%) screened positive (2 (0.7%) showed high lyso-Gb3 and 4 (1.4%) had low α-GAL levels). Finally, 2 patients (0.7%) were diagnosed with clinically significant FD. In 1 case, a female heterozygote with normal α-GAL levels had genetic variants of unknown significance and was diagnosed as FD by endomyocardial biopsy. The other case was a male chronic renal failure patient requiring hemodialysis, and he had a p.R112H mutation. In both cases there were high lyso-Gb3 levels. CONCLUSIONS: The serum lyso-Gb3 level can be relevant for clinically significant FD, and combined measurement of lyso-Gb3 and α-GAL can provide better screening of FD in unexplained LVH patients.


Asunto(s)
Enfermedad de Fabry/sangre , Glucolípidos/sangre , Hipertrofia Ventricular Izquierda/sangre , Esfingolípidos/sangre , Adolescente , Adulto , Anciano , Biomarcadores/sangre , Enfermedad de Fabry/diagnóstico por imagen , Enfermedad de Fabry/genética , Enfermedad de Fabry/fisiopatología , Femenino , Predisposición Genética a la Enfermedad , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Hipertrofia Ventricular Izquierda/genética , Hipertrofia Ventricular Izquierda/fisiopatología , Japón , Masculino , Persona de Mediana Edad , Mutación , Valor Predictivo de las Pruebas , Estudios Prospectivos , Función Ventricular Izquierda , Remodelación Ventricular , Adulto Joven , alfa-Galactosidasa/sangre , alfa-Galactosidasa/genética
10.
Heart Vessels ; 33(12): 1505-1514, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29931541

RESUMEN

Previous studies suggested that right ventricular pacing was associated with pacing-induced cardiac dysfunction (PICD). The purpose of this study was to investigate the clinical characteristics including the incidence of undiagnosed cardiac sarcoidosis (CS) in patients with atrioventricular block (AVB) who manifest PICD. We retrospectively investigated consecutive patients with permanent pacemaker (PPM) undergoing a first-generator replacement surgery with a new PPM or an upgrade procedure to a cardiac resynchronization therapy (CRT) device between December 1, 2011 and June 30, 2017. Patients with AVB showing normal echocardiographic findings before PPM implantation were included and divided into 2 groups: patients with post-PPM left ventricular ejection fraction (LVEF) < 40% and/or undergoing an upgrade procedure to CRT (PICD group) and patients with post-PPM LVEF ≥ 40% who underwent replacement surgery with a new PPM (no-PICD group). There were 15 and 41 patients in the PICD and no-PICD groups, respectively. A wider-paced QRS duration just after the PPM implantation and/or lower pre-PPM LVEF was observed in the PICD group. Furthermore, 46.7% of the PICD patients (7/15) satisfied the diagnostic criteria for CS according to the guideline of the Japanese Circulation Society, although no patients fulfilled these criteria before PPM implantation. In conclusion, a high incidence of CS was observed in patients with AVB who had PICD. However, none of these patients was diagnosed with CS before PPM implantation.


Asunto(s)
Bloqueo Atrioventricular/terapia , Cardiomiopatías/epidemiología , Errores Diagnósticos/estadística & datos numéricos , Marcapaso Artificial/efectos adversos , Sarcoidosis/epidemiología , Función Ventricular Izquierda/fisiología , Anciano , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Japón/epidemiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sarcoidosis/complicaciones , Sarcoidosis/diagnóstico
11.
Heart Vessels ; 32(11): 1382-1389, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28634694

RESUMEN

Atrial fibrillation (AF) is one of the most common cardiac arrhythmias, and carries an increased risk of cardiogenic embolism. Oral anticoagulants (OACs) including warfarin and/or non-vitamin K antagonists can prevent the majority of these events. The Saitama AF Registry was a community-based survey of patients with AF in Saitama City, which represents an urban community in Japan. A total of 75 institutions participated in the registry and attempted to enroll consecutive patients with AF from September 2014 to August 2015. The aim of the present study was to examine the clinical characteristics of patients with AF using data of the Saitama AF Registry. In addition, we investigated the difference in clinical characteristics of the patients between small-sized hospitals and large-sized hospitals. A total of 3591 patients were enrolled; 57.7% of all patients were enrolled from small-sized hospitals, whereas 42.3% were from large-sized hospitals. The patients from small-sized hospitals had higher CHADS2 score than those from large-sized hospitals. Approximately, 80% of all patients were treated with OACs, and the prescription rate was higher in patients with CHADS2 score ≥ 2 from both small-sized hospitals and large-sized hospitals. In conclusion, the present study demonstrated an appropriate use of OACs for high-risk patients with CHADS2 score ≥2 in Saitama City regardless of hospital size.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Embolia/epidemiología , Sistema de Registros , Medición de Riesgo , Encuestas y Cuestionarios , Administración Oral , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/epidemiología , Embolia/etiología , Embolia/prevención & control , Femenino , Humanos , Japón/epidemiología , Masculino , Pronóstico , Factores de Riesgo
15.
Heart ; 110(14): 954-962, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38589224

RESUMEN

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is often concomitant with sleep-disordered breathing (SDB), which can cause adverse cardiovascular events. Although an appropriate approach to SDB prevents cardiac remodelling, detection of concomitant SDB in patients with HCM remains suboptimal. Thus, we aimed to develop a machine learning-based discriminant model for SDB in HCM. METHODS: In the present multicentre study, we consecutively registered patients with HCM and performed nocturnal oximetry. The outcome was a high Oxygen Desaturation Index (ODI), defined as 3% ODI >10, which significantly correlated with the presence of moderate or severe SDB. We randomly divided the whole participants into a training set (80%) and a test set (20%). With data from the training set, we developed a random forest discriminant model for high ODI based on clinical parameters. We tested the ability of the discriminant model on the test set and compared it with a previous logistic regression model for distinguishing SDB in patients with HCM. RESULTS: Among 369 patients with HCM, 228 (61.8%) had high ODI. In the test set, the area under the receiver operating characteristic curve of the discriminant model was 0.86 (95% CI 0.77 to 0.94). The sensitivity was 0.91 (95% CI 0.79 to 0.98) and specificity was 0.68 (95% CI 0.48 to 0.84). When the test set was divided into low-probability and high-probability groups, the high-probability group had a higher prevalence of high ODI than the low-probability group (82.4% vs 17.4%, OR 20.9 (95% CI 5.3 to 105.8), Fisher's exact test p<0.001). The discriminant model significantly outperformed the previous logistic regression model (DeLong test p=0.03). CONCLUSIONS: Our study serves as the first to develop a machine learning-based discriminant model for the concomitance of SDB in patients with HCM. The discriminant model may facilitate cost-effective screening tests and treatments for SDB in the population with HCM.


Asunto(s)
Cardiomiopatía Hipertrófica , Aprendizaje Automático , Oximetría , Síndromes de la Apnea del Sueño , Humanos , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico , Masculino , Femenino , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/complicaciones , Síndromes de la Apnea del Sueño/fisiopatología , Persona de Mediana Edad , Anciano , Curva ROC , Adulto
17.
Int Heart J ; 54(3): 181-3, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23774244

RESUMEN

Spontaneous coronary artery dissection (SCAD) is considered to be a rare cause of acute coronary syndrome, especially recurrent or multivessel dissection. We present here the case of 51 year-old man who had recurrent and multivessel SCAD. In the initial event, the distal segment of the right coronary artery was spontaneously dissected, which was confirmed by coronary angiography (CAG), intracoronary ultrasound (IVUS), and multidetector computed tomography (MDCT). In the second event, the left coronary artery was spontaneously dissected. The dissection was confirmed by IVUS and MDCT, although CAG did not show stenosis, occlusion, or dissection in the left coronary artery. These findings suggest the weakness of CAG and the usefulness of IVUS or MDCT for the diagnosis of SCAD.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico por imagen , Disección Aórtica/diagnóstico por imagen , Aneurisma Coronario/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Ultrasonografía
18.
J Arrhythm ; 39(1): 42-51, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36733329

RESUMEN

Background: The acute success rate of pulmonary vein isolation (PVI) with cryoballoon (CB) is reported to be lower in the right inferior pulmonary vein (RIPV). This study aimed to investigate the utility of the "balloon lever technique (BLT)" for RIPV CB ablation. Methods: We retrospectively studied consecutive patients who underwent CB-PVI for atrial fibrillation between February 21, 2020 and June 3, 2022. RIPV cryoablation was performed according to a specific protocol. The patients underwent RIPV cryoablation using the conventional method. If the method was found ineffective, BLT cryoablation was performed. The acute success rate of RIPV CB ablation was examined. We also investigated the RIPV isolation rate and procedural parameters during conventional and BLT cryoablation. Results: Ninety-three patients were included in the analysis. RIPV isolation was achieved in 89.2% (83/93) of the patients using conventional method and subsequent BLT cryoablation. Meanwhile, 68 patients underwent BLT cryoablation because the conventional method was ineffective. RIPV was isolated with BLT in 85.3% (58/68) of patients. Additionally, BLT was found to be superior to conventional cryoablation in terms of nadir balloon temperature, freezing time, and thawing time to a specific temperature in patients who underwent both conventional and BLT cryoablations. Conclusions: BLT is useful in RIPV cryoablation when the conventional method is ineffective. BLT cryoablation may be helpful, mainly because of the BLT-mediated contact of the balloon with the bottom of the RIPV, which leads to optimal RIPV occlusion.

19.
Quant Imaging Med Surg ; 13(10): 6840-6853, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37869287

RESUMEN

Background: Left bundle branch area pacing (LBBAP) has emerged as a novel physiological pacing method to reduce left ventricular (LV) dyssynchrony due to ventricular pacing. Only lumen-less pacing leads (LLLs) with fixed helixes could achieve LBBAP previously, but recently, LBBAP has been performed using stylet-driven leads (SDLs). This study aimed to evaluate the LV dyssynchrony between SDLs and LLLs techniques in LBBAP. Methods: We retrospectively evaluated patients who underwent LBBAP with either SDLs or LLLs. We compared both groups' electrocardiogram (ECG) findings and LV dyssynchrony parameters derived from myocardial perfusion scintigraphy. LV dyssynchrony parameters consisted of phase analysis and regional wall motion analysis. We evaluated bandwidth, phase standard deviation (PSD), and entropy in the phase analysis. The time to the end-systolic frame (TES) was calculated in regional wall motion analysis using single-photon emission computed tomography (SPECT). We also evaluated the maximum differences between segmental TES (MDTES), the standard deviation of TES (SDTES), and the difference in the TES between the lateral wall and septum (DTES-LS). Results: In total, 97 patients were enrolled. The success rate of LBBAP did not differ between the groups [SDLs: 47/48 patients (98%) vs. LLLs: 47/51 patients (92%), P=0.36]. The paced QRS duration and the stimulus to the peak LV activation time (stim-LVAT) also did not differ between SDL and LLL groups (122±10 vs. 119±12 ms, P=0.206; 69±12 vs. 66±13 ms, P=0.31, respectively). There were no differences in bandwidth, PSD, and entropy between SDL and LLL groups (73°±37° vs. 86°±47°, P=0.18; 19°±8.5° vs. 21°±9.7°, P=0.19; 0.57±0.08 vs. 0.59±0.08, P=0.17, respectively). The regional wall motion analysis parameters MDTES, SDTES, and DTES-LS also did not differ between SDL and LLL groups (19%±10% vs. 20%±10%, P=0.885; 5.0%±2.5% vs. 5.0%±2.5%, P=0.995; 5.0%±3.7% vs. 4.8%±4.2%, P=0.78, respectively). Conclusions: LBBAP using SDLs was comparable to LV electrical and mechanical synchrony with LLLs.

20.
J Cardiovasc Dev Dis ; 10(5)2023 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-37233171

RESUMEN

BACKGROUND: The guideline-recommended low-density lipoprotein cholesterol target level of <70 mg/dL may not be achieved with statin administration in some patients with acute coronary syndrome (ACS). Therefore, the proprotein convertase subtilisin-kexin type 9 (PCSK9) antibody can be added to high-risk patients with ACS. Nevertheless, the optimal duration of PCSK9 antibody administration remains unclear. METHODS AND RESULTS: Patients were randomized to receive either 3 months of lipid lowering therapy (LLT) with the PCSK9 antibody followed by conventional LLT (with-PCSK9-antibody group) or 12 months of conventional LLT alone (without-PCSK9-antibody group). The primary endpoint was the composite of all-cause death, myocardial infarction, stroke, unstable angina, and ischemia-driven revascularization. A total of 124 patients treated with percutaneous coronary intervention (PCI) were randomly assigned to the two groups (n = 62 in each). The primary composite outcome occurred in 9.7% and 14.5% of the patients in the with- and without-PCSK9-antibody groups, respectively (hazard ratio: 0.70; 95% confidence interval: 0.25 to 1.97; p = 0.498). The two groups showed no significant differences in hospitalization for worsening heart failure and adverse events. CONCLUSIONS: In ACS patients who underwent PCI, short-term PCSK9 antibody therapy with conventional LLT was feasible in this pilot clinical trial. Long-term follow-up in a larger scale clinical trial is warranted.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA