Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Heart Lung Circ ; 29(3): 368-373, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30948328

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an alternative and effective contemporary intervention to surgical aortic valve replacement (SAVR) for patients with severe aortic valve disease at increased surgical risk. Guidelines recommend a multidisciplinary "Heart Team" (MHT) review of patients considered for a TAVI procedure, but this has been little studied. We reviewed the characteristics, treatments and outcomes of such patients reviewed by the MHT at our centre. METHODS: Data on consecutive patients with severe aortic valve stenosis discussed by the Auckland City Hospital MHT from June 2011 to August 2016 were obtained from clinical records. Patient characteristics, treatment and outcomes were analysed using standard statistical methods. RESULTS: Over the 5-year period 243 patients (mean age 80.2 ± 8.0 years, 60% male) were presented at the MHT meeting. TAVI was recommended for 200, SAVR for 26 and medical therapy for 17 patients, with no significant difference in mean age (80.2 ± 8.3, 80.4 ± 6.1, 80.4 ± 7.3 years, respectively) or EuroSCORE II (6.5 ± 4.7%, 5.3 ± 3.6%, 6.7 ± 4.3%, respectively). Over time, there was an increase in the number of patients discussed and treated, with no change in their mean age, but the mean EuroSCORE II significantly decreased (TAVI p = 0.026, SAVR p = 0.004). Survival after TAVI and SAVR was similar to that of the age-matched general population, but superior to medical therapy p = 0.002 (93% (n = 162), 84% (n = 21) and 73% (n = 18) at one year and 85% (n = 149), 84% (n = 21) and 54% (n = 13) at 2 years, respectively). CONCLUSIONS: An increasing number of patients were discussed at the MHT meeting with the majority undergoing TAVI, with a similar age and EuroSCORE II to those allocated SAVR or medical therapy. Survival following TAVI and SAVR was superior to medical therapy and similar to the age-matched general population. These findings suggest that the MHT process is robust, consistent and appropriately allocating a limited treatment resource.


Asunto(s)
Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Factores de Edad , Anciano , Anciano de 80 o más Años , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Tasa de Supervivencia
4.
J Magn Reson Imaging ; 44(4): 983-92, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27042817

RESUMEN

PURPOSE: To examine the feasibility of combining computational fluid dynamics (CFD) and dynamically scaled phantom phase-contrast magnetic resonance imaging (PC-MRI) for coronary flow assessment. MATERIALS AND METHODS: Left main coronary bifurcations segmented from computed tomography with bifurcation angles of 33°, 68°, and 117° were scaled-up ∼7× and 3D printed. Steady coronary flow was reproduced in these phantoms using the principle of dynamic similarity to preserve the true-scale Reynolds number, using blood analog fluid and a pump circuit in a 3T MRI scanner. After PC-MRI acquisition, the data were segmented and coregistered to CFD simulations of identical, but true-scale geometries. Velocities at the inlet region were extracted from the PC-MRI to define the CFD inlet boundary condition. RESULTS: The PC-MRI and CFD flow data agreed well, and comparison showed: 1) small velocity magnitude discrepancies (2-8%); 2) with a Spearman's rank correlation ≥0.72; and 3) a velocity vector correlation (including direction) of r(2) ≥ 0.82. The highest agreement was achieved for high velocity regions with discrepancies being located in slow or recirculating zones with low MRI signal-to-noise ratio (SNRv ) in tortuous segments and large bifurcating vessels. CONCLUSION: Characterization of coronary flow using a dynamically scaled PC-MRI phantom flow is feasible and provides higher resolution than current in vivo or true-scale in vitro methods, and may be used to provide boundary conditions for true-scale CFD simulations. J. MAGN. RESON. IMAGING 2016;44:983-992.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Circulación Coronaria/fisiología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiología , Angiografía por Resonancia Magnética/instrumentación , Modelos Cardiovasculares , Fantasmas de Imagen , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Heart Lung Circ ; 23(2): 177-80, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23731981

RESUMEN

CASE SUMMARY: A frail 87 year-old lady presented with rest angina associated with widespread ECG change and troponin release. She failed attempts at medical therapy and therefore was referred for coronary intervention on the basis that she was not a surgical candidate. INVESTIGATION: Coronary angiography demonstrated heavily calcified coronary arteries with critical disease at the distal left main stem bifurcation extending into the proximal segments of both LAD and circumflex. DIAGNOSIS: Acute coronary syndrome with extensive calcific coronary artery disease in the left main stem bifurcation. MANAGEMENT: Sequential rotational atherectomy of the left main stem bifurcation followed by 'Y'-stenting using three Xience Prime drug eluting stents.


Asunto(s)
Síndrome Coronario Agudo/cirugía , Estenosis Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Stents , Calcificación Vascular/cirugía , Síndrome Coronario Agudo/diagnóstico por imagen , Anciano de 80 o más Años , Estenosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Radiografía , Calcificación Vascular/diagnóstico por imagen
7.
Physiol Meas ; 44(9)2023 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-37478870

RESUMEN

Objective. Early diagnosis of heart problems is essential for improving patient prognosis.Approach. We created a non-contact imaging system that calculates the vessel-induced deformation of the skin to estimate the carotid artery pressure displacement waveforms. We present a clinical study of the system in patients (n= 27) with no underlying condition, aortic stenosis (AS), or mitral regurgitation (MR).Main results. Displacement waveforms were compared to aortic catheter pressures in the same patients. The morphologies of the pressure and displacement waveforms were found to be similar, and pulse wave analysis metrics, such as our modified reflection indices (RI) and waveform duration proportions, showed no significant differences. Compared with the control group, AS patients displayed a greater proportion of time to peak (p= 0.026 andp= 0.047 for catheter and displacement, respectively), whereas augmentation index (AIx)was greater for the displacement waveform only (p= 0.030). The modified RI for MR (p= 0.047 andp= 0.004 for catheter and displacement, respectively) was lower than in the controls. AS and MR were also significantly different for the proportion of time to peak (p= 0.018 for the catheter measurements), RI (p= 0.045 andp= 0.002 for the catheter and displacement, respectively), and AIx (p= 0.005 for the displacement waveform).Significance. These findings demonstrate the ability of our system to provide insights into cardiac conditions and support further development as a diagnostic/telehealth-based screening tool.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Arterias Carótidas , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Aorta , Presión Sanguínea
10.
Lancet ; 371(9616): 899-907, 2008 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-18342684

RESUMEN

BACKGROUND: A fully bioabsorbable drug-eluting coronary stent that scaffolds the vessel wall when needed and then disappears once the acute recoil and constrictive remodelling processes have subsided has theoretical advantages. The bioasorbable everolimus-eluting stent (BVS) has a backbone of poly-L-lactic acid that provides the support and a coating of poly-D,L-lactic acid that contains and controls the release of the antiproliferative agent everolimus. We assessed the feasibility and safety of this BVS stent. METHODS: In this prospective, open-label study we enrolled 30 patients who had either stable, unstable, or silent ischaemia and a single de-novo lesion that was suitable for treatment with a single 3.0 x 12 mm or 3.0 x 18 mm stent. Patients were enrolled from four academic hospitals in Auckland, Rotterdam, Krakow, and Skejby. The composite endpoint was cardiac death, myocardial infarction, and ischaemia-driven target lesion revascularisation. Angiographic endpoints were available for 26 patients and intravascular-ultrasound endpoints for 24 patients. Clinical endpoints were assessed in all 30 patients at 6 and 12 months. In a subset of 13 patients, optical coherence tomography was undertaken at baseline and follow-up. Analysis was by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00300131. FINDINGS: Procedural success was 100% (30/30 patients), and device success 94% (29/31 attempts at implantation of the stent). At 1 year, the rate of major adverse cardiac events was 3.3%, with only one patient having a non-Q wave myocardial infarction and no target lesion revascularisations. No late stent thromboses were recorded. At 6-month follow-up, the angiographic in-stent late loss was 0.44 (0.35) mm and was mainly due to a mild reduction of the stent area (-11.8%) as measured by intravascular ultrasound. The neointimal area was small (0.30 [SD 0.44] mm2), with a minimal area obstruction of 5.5%. INTERPRETATION: This study shows the feasibility of implantation of the bioabsorbable everolimus-eluting stent, with an acceptable in-stent late loss, minimal intrastent neointimal hyperplasia, and a low stent area obstruction. FUNDING: Abbott Vascular.


Asunto(s)
Enfermedad Coronaria/terapia , Stents Liberadores de Fármacos , Inmunosupresores , Sirolimus/análogos & derivados , Implantes Absorbibles , Angioplastia Coronaria con Balón , Enfermedad Coronaria/diagnóstico por imagen , Reestenosis Coronaria , Everolimus , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Seguridad , Ultrasonografía
11.
JACC Case Rep ; 1(5): 787-791, 2019 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-34316932

RESUMEN

A 79-year-old woman presented in cardiogenic shock with a flail bioprosthetic mitral valve leaflet and Staphylococcus aureus endocarditis. In the absence of other viable options, transfemoral valve-in-valve transcatheter mitral valve replacement was performed with a novel embolic protection device, resulting in trace mitral regurgitation and no neurologic complications. (Level of Difficulty: Advanced.).

13.
Am J Cardiol ; 101(7): 1060-3, 2008 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-18359332

RESUMEN

Patients with cardiovascular disease taking aspirin and some nonsteroidal anti-inflammatory drugs (NSAIDs) appear to have increased vascular events. This study was conducted to compare the ex vivo antiplatelet effects of 6 commonly used NSAIDs and to determine whether these agents antagonize the effect of aspirin. Platelet function was assessed by Platelet Function Analyzer 100 closure time in normal subjects in a randomized, blinded, multiple-crossover study. Platelet function was measured 12 hours after the administration of each NSAID. The NSAID was then given 2 hours before aspirin 300 mg, and platelet function was reassessed 24 hours later. At 12 hours after the administration of naproxen and tiaprofenic acid, closure time was significantly prolonged, whereas the other NSAIDs did not cause significant prolongations. Compared with placebo plus aspirin, closure time was significantly reduced when ibuprofen, indomethacin, naproxen, or tiaprofenic acid was given before aspirin. In conclusion, ibuprofen, indomethacin, naproxen, and tiaprofenic acid all block the antiplatelet effect of aspirin. Sulindac and celecoxib did not demonstrate any significant antiplatelet effect or reduce the antiplatelet of aspirin and, therefore, of the NSAIDs evaluated may be the drugs of choice for patients requiring aspirin and NSAIDs.


Asunto(s)
Antiinflamatorios no Esteroideos/farmacocinética , Aspirina/farmacocinética , Antagonismo de Drogas , Inhibidores de Agregación Plaquetaria/farmacocinética , Adulto , Anciano , Antiinflamatorios no Esteroideos/uso terapéutico , Aspirina/uso terapéutico , Enfermedades Cardiovasculares/tratamiento farmacológico , Estudios Cruzados , Interacción de Doble Vínculo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Pruebas de Función Plaquetaria , Factores de Tiempo
14.
Heart Lung Circ ; 17(5): 423-6, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17660046

RESUMEN

We describe a case of coronary artery perforation in a 76-year-old man, successfully treated by tris-acryl gelatin microsphere embolisation. This novel interventional embolic material is used in interventional radiology for arterial embolisation. We believe that this is the first report of its use for a coronary artery perforation.


Asunto(s)
Resinas Acrílicas/administración & dosificación , Taponamiento Cardíaco/etiología , Enfermedad Coronaria/etiología , Vasos Coronarios , Gelatina/administración & dosificación , Infarto del Miocardio/complicaciones , Derrame Pericárdico/etiología , Anciano , Taponamiento Cardíaco/terapia , Cineangiografía/métodos , Enfermedad Coronaria/terapia , Humanos , Masculino , Infarto del Miocardio/terapia , Derrame Pericárdico/diagnóstico por imagen , Inducción de Remisión , Rotura Espontánea/diagnóstico por imagen
15.
Heart Lung Circ ; 17(2): 119-23, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18060839

RESUMEN

BACKGROUND: Ventricular septal defect (VSD) is a serious complication of myocardial infarction (MI), occurring in about 0.2% of cases. Untreated, mortality in high and early surgical repair is difficult because of friable necrotic tissue. Percutaneous closure may be an alternative treatment option in selected patients. METHODS: We report our complete single centre experience of percutaneous post-MI VSD closure using the Amplatzer device. The VSD was closed under general anaesthesia with fluoroscopic and transoesophageal echocardiographic guidance. Clinical characteristics and outcomes are reported. RESULTS: The five patients were aged from 66 to 76 years. Closure was attempted from 1 to 64 days post-MI. VSD closure was performed in two patients after surgical patch dehiscence (infero-apical and infero-basal VSDs). The procedure was successful in four patients, with failure to cross the interventricular septum in one. Thirty-day and 12-month survival was 3/5 (60%); no patient undergoing VSD closure early post-MI survived, whereas 3/3 in whom the procedure was undertaken >14 days post-MI survived, suggesting that it may be appropriate to delay attempts at percutaneous VSD closure after MI. CONCLUSION: Percutaneous VSD closure post-MI appears to be a viable alternative to surgical repair, with favourable outcomes if it can be undertaken >14 days post-infarct.


Asunto(s)
Procedimientos Quirúrgicos Cardiovasculares/efectos adversos , Procedimientos Quirúrgicos Cardiovasculares/métodos , Infarto del Miocardio/complicaciones , Implantación de Prótesis/métodos , Rotura Septal Ventricular/cirugía , Anciano , Ecocardiografía Transesofágica , Resultado Fatal , Femenino , Humanos , Masculino , Implantación de Prótesis/efectos adversos , Rotura Septal Ventricular/etiología
16.
Open Heart ; 5(2): e000918, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30564377

RESUMEN

Objective: Takotsubo syndrome (TS) mimics acute coronary syndrome (ACS) but has a distinct pathophysiology. While in-hospital adverse outcomes appear similar to those presenting with an ACS, data on longer term postdischarge risk are conflicting. This study sought to assess the long-term prognosis of patients discharged alive after TS. Methods: The clinical profile and in-hospital and long-term outcomes were prospectively assessed in consecutive patients with TS. Survival in patients with TS was compared with two representative age-matched and gender-matched comparison cohorts: a hospitalised ACS cohort and a community cohort without known cardiovascular disease (CVD). Results: Two hundred and-twenty-five patients with TS (216 women, mean age 63.7±11.8 years) were included. In-hospital mortality was 1.8% and 1.9% for patients with TS and ACS, respectively. Of the 219 patients with TS with postdischarge follow-up, at a mean follow-up of 4.8±3.2 years, there were 19 (8.3%) deaths, 18 of which were from non-cardiac causes. When compared with the cohort without prior CVD, postdischarge patients with TS were at increased mortality risk (HR 2.00, 95% CI 1.26 to 3.17, p=0.003), but mortality in postdischarge patients with ACS was over threefold higher (HR 3.43, 95% CI 2.97 to 3.96, p<0.0001). Conclusions: In-hospital mortality for patients diagnosed with TS and ACS was similar. However, while postdischarge survivors of TS had a long-term survival which was poorer than for a community-based cohort without known CVD, their survival was better than for postdischarge survivors of an ACS event. Late deaths in patients with TS were almost all from non-cardiac causes.

17.
EuroIntervention ; 13(15): e1794-e1803, 2018 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-29131803

RESUMEN

This is a consensus document from the European Bifurcation Club concerning bench testing in coronary artery bifurcations. It is intended to provide guidelines for bench assessment of stents and other strategies in coronary bifurcation treatment where the United States Food and Drug Administration (FDA) or International Organization for Standardization (ISO) guidelines are limited or absent. These recommendations provide guidelines rather than a step-by-step manual. We provide data on the anatomy of bifurcations and elastic response of coronary arteries to aid model construction. We discuss testing apparatus, bench testing endpoints and bifurcation nomenclature.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Ensayo de Materiales/normas , Modelos Anatómicos , Intervención Coronaria Percutánea/normas , Consenso , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Análisis de Falla de Equipo/normas , Hemodinámica , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Diseño de Prótesis , Falla de Prótesis , Stents/normas , Terminología como Asunto
18.
Open Heart ; 4(2): e000680, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29118997

RESUMEN

The ideal stent must fulfil a broad range of technical requirements. Stents must be securely crimped onto the delivery balloon and, in this form, must have a low profile and be sufficiently flexible to facilitate deliverability to the lesion site without distortion or displacement. Following expansion, stents must exert sufficient radial force on the vessel wall to overcome lesion resistance and elastic recoil. To achieve an optimal lumen diameter, the lesion must be uniformly and adequately scaffolded, with minimal tissue prolapse between struts but without compromising side-branch access. Furthermore, the deployed stent must conform to the vessel curvature to minimise vessel distortion, particularly at the stent edges. Radio-opacity is also important to guide safe positioning, adequate deployment and postdilataion and to permit assessment of optimal stent expansion. Equally though, the stent lumen must also be sufficiently visible to allow radiographic assessment of flow dynamics and restenosis. Efforts to optimise one characteristic of stent design may have detrimental effects on another. Thus, currently available stents all reflect a compromise between competing desirable features and have subtle differences in their performance characteristics. Striving to achieve stents with optimal deliverability, conformability and radial strength led to a reduction in longitudinal strength. The importance of this parameter was highlighted by complications occurring in the real-world setting where percutaneous coronary intervention is often undertaken in challenging anatomy. This review focuses on aspects of stent design relevant to longitudinal strength.

19.
Atherosclerosis ; 262: 94-100, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28531827

RESUMEN

BACKGROUND AND AIMS: Catheter-based renal denervation for the treatment of drug-resistant hypertension has been intensively investigated in recent years. To date, only limited data have been published using multi-electrode radiofrequency ablation systems that can deliver lesions with a pre-determined pattern. This study was designed to evaluate the safety and performance of the second generation EnligHTN™ Renal Denervation System. METHODS: This first-in-human, prospective, multi-center, non-randomized study included 39 patients (62% male, mean age 63 years, and mean baseline office blood pressure 174/93 mmHg) with drug-resistant hypertension. The primary safety and performance objectives were to characterize, from baseline to 6 months post procedure, the rate of serious procedural and device related adverse events, as adjudicated by an independent Clinical Events Committee, and the reduction of office systolic blood pressure. RESULTS: Renal artery denervation, using the second generation EnligHTN multi-electrode system significantly reduced office blood pressure from baseline to 1, 3, 6, 12, 18 and 24 months by 19/7, 26/9, 25/7, 23/7, 25/8 and 27/9 mmHg, respectively (p ≤ 0.0005). No serious device or procedure related adverse events affecting the renal arteries or renal function occurred through 24 months of follow-up. CONCLUSIONS: Renal sympathetic denervation using the second generation EnligHTN Renal Denervation System resulted in safe, rapid, and significant mean office blood pressure reduction that was sustained through 24 months. Future studies will need to address the utility of this system against an appropriate sham based comparator.


Asunto(s)
Presión Sanguínea , Ablación por Catéter/instrumentación , Hipertensión/cirugía , Riñón/irrigación sanguínea , Arteria Renal/inervación , Simpatectomía/instrumentación , Sistema Nervioso Simpático/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antihipertensivos/uso terapéutico , Australia , Presión Sanguínea/efectos de los fármacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resistencia a Medicamentos , Femenino , Humanos , Hipertensión/diagnóstico , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Nueva Zelanda , Estudios Prospectivos , Simpatectomía/efectos adversos , Simpatectomía/métodos , Sistema Nervioso Simpático/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA