Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Thorac Cardiovasc Surg ; 71(4): 243-254, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-34521141

RESUMEN

BACKGROUND: The aim of this study was to describe outcomes of patients undergoing surgical ablation for atrial fibrillation (AF) as either stand-alone or concomitant cardiosurgical procedures in Germany. METHODS: Patients with AF undergoing concomitant or stand-alone surgical ablation were included in the registry. Cardiac surgery centers across Germany were invited to participate and sought to enroll 1,000 consecutive patients. Data was obtained through electronic case report forms. The protocol mandated follow-up interviews at 1 year. RESULTS: Between January 2017 and April 2020, 17 centers enrolled 1,000 consecutive patients. Among concomitant surgical patients (n = 899), paroxysmal AF was reported in 55.4% patients. Epicardial radio frequency (RF) bilateral pulmonary vein isolation (PVI) with excision of the left atrial appendage (LAA) was the most common operative strategy. In the stand-alone cohort (n = 101), persistent AF forms were reported in 84.1% of patients. Moderate-to-severe symptoms were reported in 85.1%. Sixty-seven patients had previously underwent at least two failed catheter ablative procedures. Thoracoscopic epicardial RF bilateral PVI and completion of a "box-lesion" with LAA closure were frequently preformed. Major cardiac and cerebrovascular complications occurred in 38 patients (4.3%) in the concomitant group. No deaths were reported in the stand-alone group. At discharge, sinus rhythm was achieved in 88.1% of stand-alone and 63.4% concomitant patients. CONCLUSION: The CArdioSurgEry Atrial Fibrillation registry provides insights into surgical strategies for AF ablation in a considerable cohort across Germany. This in-hospital data demonstrates that concomitant and stand-alone ablation during cardiac surgery is safe and effective with low complication rates.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Resultado del Tratamiento , Apéndice Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía
2.
Thorac Cardiovasc Surg ; 71(4): 255-263, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-35896439

RESUMEN

OBJECTIVES: This study of German Cardiosurgery Atrial Fibrillation (CASE-AF) registry aims to describe the 1-year outcomes of patients undergoing ablative procedures for atrial fibrillation (AF) in a cardiosurgical setting. METHODS: Between January 2017 and April 2020, 17 German cardiosurgical units enrolled 1,000 consecutive patients undergoing concomitant or stand-alone ablation for AF. In-hospital and 1-year follow-up data were collected on web-based electronic case report forms. The protocol mandated telephone-based follow-up contact after 1 year. RESULTS: At 1-year follow-up (median, 14.5 months [12.6-18.2 months]), significant improvement (p < 0.0001) in baseline modified European Heart Rhythm Association Class I was reported in both concomitant and stand-alone patients. Follow-up examinations were completed in 97.9% of cases, and a sinus rhythm was reported in 60.2 and 63.6% of stand-alone and concomitant patients, respectively. Statistically significant factors determining late recurrence were female gender (p = 0.013), preoperative persistent AF (p < 0.0001), and presence of cardiac implantable electronic device (p = 0.011). All-cause mortality at 1 year was 1% (n = 1) in stand-alone patients and 6.7% (n = 58) in concomitant patients. CONCLUSION: Surgical ablation of AF is safe and provides satisfactory results at short-term follow-up, with significant improvement in patient symptoms. Adequate cardiac rhythm monitoring should be prioritized for higher quality data acquisition.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Femenino , Masculino , Fibrilación Atrial/diagnóstico , Estudios de Seguimiento , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Corazón
3.
Europace ; 24(10): 1627-1635, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35718878

RESUMEN

AIMS: The GermAn Laser Lead Extraction RegistrY: GALLERY is a retrospective, national multicentre registry, investigating the safety and efficacy of laser lead extraction procedures in Germany. METHODS AND RESULTS: Twenty-four German centres that are performing laser lead extraction have participated in the registry. All patients, treated with a laser lead extraction procedure between January 2013 and March 2017, were consecutively enrolled. Safety and efficacy of laser lead extraction were investigated. A total number of 2524 consecutive patients with 6117 leads were included into the registry. 5499 leads with a median lead dwell time of 96 (62-141) months were treated. The mean number of treated leads per patient was 2.18 ± 1.02. The clinical procedural success rate was 97.86% and the complete lead removal was observed in 94.85%. Additional extraction tools were used in 6.65% of cases. The rate of procedural failure was 2.14% with lead age ≥10 years being its only predictor. The overall complication rate was 4.32%, including 2.06% major and 2.26% minor complications. Procedure-related mortality was 0.55%. Female sex and the presence of abandoned leads were predictors for procedure-related complications. The all-cause in-hospital mortality was 3.56% with systemic infection being the strongest predictor, followed by age ≥75 years and chronic kidney disease. CONCLUSION: In the GALLERY, a high success- and low procedure-related complication rates have been demonstrated. In multivariate analysis, female sex and the presence of abandoned leads were predictors for procedure-related complications, while the presence of systemic infection, age ≥75 years, and chronic kidney disease were independent predictors for all-cause mortality.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Insuficiencia Renal Crónica , Anciano , Niño , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/métodos , Femenino , Humanos , Láseres de Excímeros , Marcapaso Artificial/efectos adversos , Complicaciones Posoperatorias/etiología , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
4.
Artif Organs ; 45(3): 244-253, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32857884

RESUMEN

Postinfarction ventricular septal defect (pVSD) due to acute myocardial infarction complicated by cardiogenic shock (CS) is associated with high mortality. The aim of this study was to determine the outcome of primary surgical repair of pVSD in patients with CS and examine whether it is influenced by the use of mechanical circulatory support (MCS) devices. Between October 1994 and April 2016, primary surgical repair of pVSD complicated by CS was performed in 53 patients. Thirty-six (68%) were implanted pre-operatively with an intra-aortic balloon pump (IABP), 4 (8%) with extracorporeal life support (ECLS), and 13 (24%) received no MCS device. Prospectively collected demographic and perioperative data were analyzed retrospectively. All-cause, 30-day mortality rates were analyzed and multivariate analysis was performed to differentiate independent risk factors. No pre-operatively implanted MCS device was able to improve 30-day survival, whereas pre-operatively implanted ECLS tended to have a positive effect (P = .106). The post-operative need for a MCS device or escalation of MCS invasiveness (IABP upgrade to ECLS) was associated with a higher 30-day mortality (P = .001) compared with patients without any MCS device or those with pre-operatively implanted MCS devices. An independent risk factor for 30-day mortality was the interval between acute myocardial infarction and surgery <7 days (OR 5.895, CI 1.615-21.515; P = .007). Pre-operative implantation of ECLS for CS tends to improve the outcome of early primary surgical pVSD repair. The need for a post-operative MCS device is associated with a worse 30-day survival after early primary surgical pVSD repair.


Asunto(s)
Oxigenación por Membrana Extracorpórea/estadística & datos numéricos , Defectos del Tabique Interventricular/cirugía , Contrapulsador Intraaórtico/estadística & datos numéricos , Infarto del Miocardio/terapia , Choque Cardiogénico/terapia , Anciano , Oxigenación por Membrana Extracorpórea/métodos , Femenino , Defectos del Tabique Interventricular/etiología , Defectos del Tabique Interventricular/mortalidad , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/mortalidad , Periodo Posoperatorio , Periodo Preoperatorio , Estudios Retrospectivos , Factores de Riesgo , Choque Cardiogénico/etiología , Choque Cardiogénico/mortalidad , Factores de Tiempo , Tiempo de Tratamiento , Resultado del Tratamiento
5.
Heart Surg Forum ; 24(3): E522-E529, 2021 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-34173744

RESUMEN

BACKGROUND: A postinfarction ventricular septal defect (pVSD) as a complication of acute myocardial infarction (AMI) is associated with high mortality. This retrospective, single-center study aimed to identify predictors of early and long-term outcomes in patients undergoing primary surgical repair of pVSD managed by various surgical techniques. METHODS: We reviewed data from 77 consecutive patients who underwent primary surgical repair after pVSD in our institution. Prospectively collected demographic and perioperative data were analyzed retrospectively. Predictors of 30-day mortality and long-term outcome were assessed. RESULTS: pVSD was anterior in 45 patients (58.4%) and posterior in 32 (41.6%). Buttressed mattress suture (n = 9, 11.7%), simple single septal patch (n = 34, 44.2%), simple double septal patch (n = 2, 2.6%), sandwich double patch (n = 1, 1.3%), and the infarct exclusion technique (n = 31, 40.3%) were performed for surgical closure. Fifty-three patients (68.8%) had preoperative cardiogenic shock. The 30-day mortality was 42.8% (33 patients). Independent risk factors of 30-day mortality were duration between AMI and surgery <7 days (odds ratio [OR] 5.229, P = .011), preoperative absence of diuretics (OR 6.913, P = .005), and preoperative cardiogenic shock (OR 3.558, P = .011). Cumulative survival rates at 1, 5, and 10 years were 57.1%, 57.1%, and 31.2%, respectively. CONCLUSION: In pVSD, the 30-day mortality remains high, and preoperative cardiogenic shock significantly influenced mortality in our study. None of the surgical techniques or materials used in our investigation influenced the outcome.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Defectos del Tabique Interventricular/mortalidad , Infarto del Miocardio/complicaciones , Anciano , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Defectos del Tabique Interventricular/etiología , Defectos del Tabique Interventricular/cirugía , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo
6.
Thorac Cardiovasc Surg ; 66(8): 629-636, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-28602019

RESUMEN

BACKGROUND: Little is known about the perioperative course of patients with Parkinson's disease (PD) undergoing cardiac surgery. The objective of this study was to identify the influence of PD on the perioperative course and to improve treatment. METHODS: Perioperative data were analyzed retrospectively from 130 patients undergoing cardiac surgery between September 2001 and April 2013 who had PD and were compared using 1:1 matched-pair analysis with 130 controls not affected by PD. RESULTS: The 30-day all-cause mortality (4.6 vs. 9.2%; p = 0.21; odds ratio [OR] = 0.45; 95% confidence interval [CI]: 0.16, 1.31) and the overall all-cause mortality (27.7 vs. 28.5%; hazard ratio [HR] = 0.96 [0.56, 1.66]; p = 1.00) were not significantly different between PD patients and the control group. Emergency surgery (p = 0.04; OR = 3.20; 95% CI: 1.06, 9.66) and postoperative pneumonia (p < 0.001; OR = 11.3; 95% CI: 3.06, 41.6) were associated with 30-day mortality. Independent predictors of all-cause mortality were age at surgery (p = 0.01; OR = 3.58; 95% CI: 1.38, 9.30), NYHA (New York Heart Association) classification stage IV (p = 0.02; OR = 17.3; 95% CI: 1.52, 198), and postoperative pneumonia (p = 0.05; OR = 46.4; 95% CI: 0.97, 2219). We did not observe an association of PD with short- or long-term all-cause mortality after adjustment for associated covariates. CONCLUSIONS: We found that PD is not a significant risk factor for perioperative morbidity and mortality in our cohort. Our study showed that patients with PD had outcomes that were similar to those of non-PD patients.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiopatías/cirugía , Enfermedad de Parkinson/complicaciones , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Femenino , Cardiopatías/complicaciones , Cardiopatías/diagnóstico , Cardiopatías/mortalidad , Humanos , Masculino , Enfermedad de Parkinson/diagnóstico , Enfermedad de Parkinson/mortalidad , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
J Magn Reson Imaging ; 45(2): 535-541, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27459111

RESUMEN

PURPOSE: To determine the impact of myocardial iron overload on left atrial (LA) volume and function using MR in patients with systemic iron overload. MATERIALS AND METHODS: Thirty-eight patients with systemic iron overload disease and 10 controls underwent 1.5 Tesla MR performing steady state free precession short-axis cine-series of the LA. Three-dimensional-volumetry was assessed to calculate LA volumes and function. Parameters were indexed (i) to body surface area. The myocardial transverse relaxation rate R2* was determined in the ventricular septum using a multi-echo GRE sequence (breathhold; electrocardiography triggered; 12 echoes; echo time = 1.3-25.7 ms). RESULTS: Significantly decreased active atrial emptying fraction (AAEF) (23% [95%-range, 7-34] versus 36% [95%-range, 14-49], P = 0.009), active atrial emptying volume (AAEVi) (5.5 mL/m2 [95%-range, 2-11] versus 11.9 mL/m2 [95%-range, 3-23], P = 0.008), and active peak emptying rate (APERi) (46 mL/s/m2 [95%-range, 29-69] versus 75 mL/s/m2 [95%-range, 45-178], P < 0.001) were found for patients with myocardial iron overload (R2* > 40 s-1 ) compared with patients with normal myocardial iron levels (R2* < 40 s-1 ). Receiver operating characteristics (ROC) analysis revealed higher potential to indicate myocardial iron overload for the AAEF (area under the ROC curve [AUC] = 0.84; P < 0.0001), APERi (AUC = 0.87; P < 0.0001), and AAEVi (AUC = 0.80; P < 0.0001) compared with LA ejection fraction (LAEF) (AUC = 0.68; P = 0.02) with equal sensitivities and specificities of 82% (AAEF), 79% (APERi), 73% (AAEVi), and 57% (LAEF). CONCLUSION: MR parameters of active LA contractile function were associated with myocardial iron overload. This cross-sectional study suggests impaired active LA contractile function to be sensitive to myocardial iron toxicity. LEVEL OF EVIDENCE: 3 J. Magn. Reson. Imaging 2017;45:535-541.


Asunto(s)
Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Sobrecarga de Hierro/diagnóstico por imagen , Sobrecarga de Hierro/fisiopatología , Hierro/metabolismo , Imagen por Resonancia Cinemagnética/métodos , Contracción Miocárdica , Adolescente , Adulto , Anciano , Técnicas de Imagen Cardíaca/métodos , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Eur J Cardiothorac Surg ; 55(6): 1234-1235, 2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-30351411

RESUMEN

The spectrum of cardiac injury due to blunt chest trauma may range from cardiac contusions with a clinically silent course to fatal cardiac wall rupture. Pulmonary valve insufficiency due to non-penetrating chest trauma is a rare entity. In this case, pulmonary valve insufficiency as a result of valve tear due to high-velocity blunt chest trauma required surgical replacement.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Pulmonar/etiología , Traumatismos Torácicos/complicaciones , Heridas no Penetrantes/complicaciones , Adulto , Ecocardiografía , Humanos , Masculino , Insuficiencia de la Válvula Pulmonar/diagnóstico , Insuficiencia de la Válvula Pulmonar/cirugía , Traumatismos Torácicos/diagnóstico , Heridas no Penetrantes/diagnóstico
10.
Ann Thorac Surg ; 100(3): 1103-5, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26354643

RESUMEN

To avoid a third major cardiovascular surgery in an 84-year-old man, a Melody Transcatheter Pulmonary Valve was implanted in a functionally stenotic bioprosthesis in the pulmonary position. The intervention was free of complications with good results.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Falla de Prótesis , Válvula Pulmonar/cirugía , Anciano de 80 o más Años , Constricción Patológica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Complicaciones Posoperatorias/cirugía , Reoperación
11.
Ann Thorac Surg ; 100(5): e111-3, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26522575

RESUMEN

Coronary artery fistula (CAF) is an incidental finding in up to 0.2% of cardiac catheterization studies and is a rare pathologic condition affecting up to 1% of the general population. We report two cases of CAF diagnosed by coronary angiography and managed by surgical ligation, with excellent postoperative outcome. Anatomic location, clinical presentation, investigation, and treatment of CAF are discussed.


Asunto(s)
Fístula Arterio-Arterial/diagnóstico , Cateterismo Cardíaco/métodos , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Fístula Arterio-Arterial/cirugía , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Diagnóstico Diferencial , Electrocardiografía , Femenino , Humanos , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
12.
Am J Blood Res ; 5(2): 86-90, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-27069756

RESUMEN

Myelodysplastic syndromes (MDS) are a heterogeneous group of clonal hematopoietic disorders characterized by peripheral blood cytopenias, blood cells dysplasia, and increased risk for progression to acute leukemia.Physicians should be vigilant in diagnosing MDS and should be aware of the contemporary therapies that are always in progress. Most of the data on MDS epidemiology and management comes from developed countries. The incidence and features of MDS in the Arab countries, among them Lebanon, are not known. We undertook a nationwide epidemiological registry study of all newly diagnosed MDS cases through 2010-2011. Patients were referred by 21 hematologists/oncologists practicing in 17 hospitals and medical centers distributed across the entire country. 58 patients (29 males and 29 females) with confirmed MDS were included. The calculated incidence rate of MDS was 0.71 per 100,000 people. The median age at diagnosis was 73 years (range 16-86). The most common complaints on presentation were fatigue (70.7%), weakness (60.3%) and pallor (43.1%). Most patients were diagnosed as refractory anemia with excess blasts (RAEB; 36.2%) and refractory cytopenia with multilineage dysplasia (RCMD; 32.8%). This paper constitutes the first epidemiological report on the incidence and specific subtypes of MDS in Lebanon.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA