Langenbecks Arch Chir ; 356(4): 251-7, 1982.
Artículo en Alemán | MEDLINE | ID: mdl-6808267

RESUMEN

The canine liver was isolated from its blood supply and perfused for one hour normothermically be means of a new catheter and a perfusion system consisting of oxygenator, pump and heat-exchanger. Hemodynamic parameters, blood gas analyses, and tissue metabolites were evaluated during experiments. The venous return from the lower body and portal vein (1.113/1min) could be maintained with the catheter system so that the mean systemic arterial pressure was within normal limits. With a perfusion rate through the liver 0,55 ml/min/g and perfusion pressure of 10 cm H2O there was an adequate tissue perfusion; this was also shown by blood gas analyses and tissue metabolite concentrations. Using dye dilution methods the isolation of the liver was tested. This showed a leakage of 6-7% of the total perfusion volume. This new method makes it possible to carry out an isolated, normothermic, liver perfusion for one hour without irreversible tissue damage.


Asunto(s)
Quimioterapia del Cáncer por Perfusión Regional/instrumentación , Neoplasias Hepáticas/tratamiento farmacológico , Animales , Antineoplásicos/uso terapéutico , Velocidad del Flujo Sanguíneo , Dióxido de Carbono/sangre , Cateterismo/instrumentación , Perros , Oxígeno/sangre , Derivación Portocava Quirúrgica/instrumentación