Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 45(5): 759-767, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29164301

RESUMEN

OBJECTIVE: To assess the optimal timing and predictive value of early intra-treatment changes in multimodality functional and molecular imaging (FMI) parameters as biomarkers for clinical remission in patients receiving chemoradiation for head and neck squamous cell carcinoma (HNSCC). METHODS: Thirty-five patients with stage III-IVb (AJCC 7th edition) HNSCC prospectively underwent 18F-FDG-PET/CT, and diffusion-weighted (DW), dynamic contrast-enhanced (DCE) and susceptibility-weighted MRI at baseline, week 1 and week 2 of chemoradiation. Patients with evidence of persistent or recurrent disease during follow-up were classed as non-responders. Changes in FMI parameters at week 1 and week 2 were compared between responders and non-responders with the Mann-Whitney U test. The significance threshold was set at a p value of <0.05. RESULTS: There were 27 responders and 8 non-responders. Responders showed a greater reduction in PET-derived tumor total lesion glycolysis (TLG40%; p = 0.007) and maximum standardized uptake value (SUVmax; p = 0.034) after week 1 than non-responders but these differences were absent by week 2. In contrast, it was not until week 2 that MRI-derived parameters were able to discriminate between the two groups: larger fractional increases in primary tumor apparent diffusion coefficient (ADC; p < 0.001), volume transfer constant (Ktrans; p = 0.012) and interstitial space volume fraction (Ve; p = 0.047) were observed in responders versus non-responders. ADC was the most powerful predictor (∆ >17%, AUC 0.937). CONCLUSION: Early intra-treatment changes in FDG-PET, DW and DCE MRI-derived parameters are predictive of ultimate response to chemoradiation in HNSCC. However, the optimal timing for assessment with FDG-PET parameters (week 1) differed from MRI parameters (week 2). This highlighted the importance of scanning time points for the design of FMI risk-stratified interventional studies.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico por imagen , Quimioradioterapia , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Imagen Multimodal , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adulto , Anciano , Carcinoma de Células Escamosas/terapia , Imagen de Difusión por Resonancia Magnética , Femenino , Fluorodesoxiglucosa F18 , Neoplasias de Cabeza y Cuello/terapia , Humanos , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones
2.
Phys Med Biol ; 64(8): 08NT01, 2019 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-30808011

RESUMEN

Radiotherapy treatment plans using dynamic couch rotation during volumetric modulated arc therapy (DCR-VMAT) reduce the dose to organs at risk (OARs) compared to coplanar VMAT, while maintaining the dose to the planning target volume (PTV). This paper seeks to validate this finding with measurements. DCR-VMAT treatment plans were produced for five patients with primary brain tumours and delivered using a commercial linear accelerator (linac). Dosimetric accuracy was assessed using point dose and radiochromic film measurements. Linac-recorded mechanical errors were assessed by extracting deviations from log files for multi-leaf collimator (MLC), couch, and gantry positions every 20 ms. Dose distributions, reconstructed from every fifth log file sample, were calculated and used to determine deviations from the treatment plans. Median (range) treatment delivery times were 125 s (123-133 s) for DCR-VMAT, compared to 78 s (64-130 s) for coplanar VMAT. Absolute point doses were 0.8% (0.6%-1.7%) higher than prediction. For coronal and sagittal films, respectively, 99.2% (96.7%-100%) and 98.1% (92.9%-99.0%) of pixels above a 20% low dose threshold reported gamma <1 for 3% and 3 mm criteria. Log file analysis showed similar gantry rotation root-mean-square error (RMSE) for VMAT and DCR-VMAT. Couch rotation RMSE for DCR-VMAT was 0.091° (0.086-0.102°). For delivered dose reconstructions, 100% of pixels above a 5% low dose threshold reported gamma <1 for 2% and 2 mm criteria in all cases. DCR-VMAT, for the primary brain tumour cases studied, can be delivered accurately using a commercial linac.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Posicionamiento del Paciente/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Algoritmos , Humanos , Órganos en Riesgo , Aceleradores de Partículas , Posicionamiento del Paciente/normas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia de Intensidad Modulada/normas , Rotación
3.
Int J Radiat Oncol Biol Phys ; 100(2): 306-316, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-29229323

RESUMEN

PURPOSE: To determine the 3-dimensional (3D) intrafractional motion of head and neck squamous cell carcinoma (HNSCC). METHODS AND MATERIALS: Dynamic contrast-enhanced magnetic resonance images from 56 patients with HNSCC in the treatment position were analyzed. Dynamic contrast-enhanced magnetic resonance imaging consisted of 3D images acquired every 2.9 seconds for 4 minutes 50 seconds. Intrafractional tumor motion was studied in the 3 minutes 43 seconds of images obtained after initial contrast enhancement. To assess tumor motion, rigid registration (translations only) was performed using a region of interest (ROI) mask around the tumor. The results were compared with bulk body motion from registration to all voxels. Motion was split into systematic motion and random motion. Correlations between the tumor site and random motion were tested. The within-subject coefficient of variation was determined from 8 patients with repeated baseline measures. Random motion was also assessed at the end of the first week (38 patients) and second week (25 patients) of radiation therapy to investigate trends of motion. RESULTS: Tumors showed irregular occasional rapid motion (eg, swallowing or coughing), periodic intermediate motion (respiration), and slower systematic drifts throughout treatment. For 95% of the patients, displacements due to systematic and random motion were <1.4 mm and <2.1 mm, respectively, 95% of the time. The motion without an ROI mask was significantly (P<.0001, Wilcoxon signed rank test) less than the motion with an ROI mask, indicating that tumors can move independently from the bony anatomy. Tumor motion was significantly (P=.005, Mann-Whitney U test) larger in the hypopharynx and larynx than in the oropharynx. The within-subject coefficient of variation for random motion was 0.33. The average random tumor motion did not increase notably during the first 2 weeks of treatment. CONCLUSIONS: The 3D intrafractional tumor motion of HNSCC is small, with systematic motion <1.4 mm and random motion <2.1 mm 95% of the time.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Carcinoma de Células Escamosas de Cabeza y Cuello/radioterapia , Medios de Contraste , Humanos , Aumento de la Imagen , Movimiento (Física) , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen
4.
Radiother Oncol ; 121(1): 124-131, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27481571

RESUMEN

BACKGROUND AND PURPOSE: To evaluate non-coplanar volumetric modulated arc radiotherapy (VMAT) trajectories for organ at risk (OAR) sparing in primary brain tumor radiotherapy. MATERIALS AND METHODS: Fifteen patients were planned using coplanar VMAT and compared against non-coplanar VMAT plans for three trajectory optimization techniques. A geometric heuristic technique (GH) combined beam scoring and Dijkstra's algorithm to minimize the importance-weighted sum of OAR volumes irradiated. Fluence optimization was used to perform a local search around coplanar and GH trajectories, producing fluence-based local search (FBLS) and FBLS+GH trajectories respectively. RESULTS: GH, FBLS, and FBLS+GH trajectories reduced doses to the contralateral globe, optic nerve, hippocampus, temporal lobe, and cochlea. However, FBLS increased dose to the ipsilateral lens, optic nerve and globe. Compared to GH, FBLS+GH increased dose to the ipsilateral temporal lobe and hippocampus, contralateral optics, and the brainstem and body. GH and FBLS+GH trajectories reduced bilateral hippocampi normal tissue complication probability (p=0.028 and p=0.043, respectively). All techniques reduced PTV conformity; GH and FBLS+GH trajectories reduced homogeneity but less so for FBLS+GH. CONCLUSIONS: The geometric heuristic technique best spared OARs and reduced normal tissue complication probability, however incorporating fluence information into non-coplanar trajectory optimization maintained PTV homogeneity.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Algoritmos , Neoplasias Encefálicas/diagnóstico por imagen , Humanos , Modelos Biológicos , Órganos en Riesgo/diagnóstico por imagen , Probabilidad , Dosificación Radioterapéutica
5.
Radiother Oncol ; 120(1): 21-7, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27240717

RESUMEN

BACKGROUND AND PURPOSE: Severe acute mucositis commonly results from head and neck (chemo)radiotherapy. A predictive model of mucositis could guide clinical decision-making and inform treatment planning. We aimed to generate such a model using spatial dose metrics and machine learning. MATERIALS AND METHODS: Predictive models of severe acute mucositis were generated using radiotherapy dose (dose-volume and spatial dose metrics) and clinical data. Penalised logistic regression, support vector classification and random forest classification (RFC) models were generated and compared. Internal validation was performed (with 100-iteration cross-validation), using multiple metrics, including area under the receiver operating characteristic curve (AUC) and calibration slope, to assess performance. Associations between covariates and severe mucositis were explored using the models. RESULTS: The dose-volume-based models (standard) performed equally to those incorporating spatial information. Discrimination was similar between models, but the RFCstandard had the best calibration. The mean AUC and calibration slope for this model were 0.71 (s.d.=0.09) and 3.9 (s.d.=2.2), respectively. The volumes of oral cavity receiving intermediate and high doses were associated with severe mucositis. CONCLUSIONS: The RFCstandard model performance is modest-to-good, but should be improved, and requires external validation. Reducing the volumes of oral cavity receiving intermediate and high doses may reduce mucositis incidence.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Aprendizaje Automático , Traumatismos por Radiación/etiología , Estomatitis/etiología , Enfermedad Aguda , Toma de Decisiones Clínicas , Femenino , Humanos , Modelos Logísticos , Masculino , Modelos Teóricos , Probabilidad , Dosificación Radioterapéutica
6.
Int J Radiat Oncol Biol Phys ; 96(4): 820-831, 2016 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-27788955

RESUMEN

PURPOSE: Current normal tissue complication probability modeling using logistic regression suffers from bias and high uncertainty in the presence of highly correlated radiation therapy (RT) dose data. This hinders robust estimates of dose-response associations and, hence, optimal normal tissue-sparing strategies from being elucidated. Using functional data analysis (FDA) to reduce the dimensionality of the dose data could overcome this limitation. METHODS AND MATERIALS: FDA was applied to modeling of severe acute mucositis and dysphagia resulting from head and neck RT. Functional partial least squares regression (FPLS) and functional principal component analysis were used for dimensionality reduction of the dose-volume histogram data. The reduced dose data were input into functional logistic regression models (functional partial least squares-logistic regression [FPLS-LR] and functional principal component-logistic regression [FPC-LR]) along with clinical data. This approach was compared with penalized logistic regression (PLR) in terms of predictive performance and the significance of treatment covariate-response associations, assessed using bootstrapping. RESULTS: The area under the receiver operating characteristic curve for the PLR, FPC-LR, and FPLS-LR models was 0.65, 0.69, and 0.67, respectively, for mucositis (internal validation) and 0.81, 0.83, and 0.83, respectively, for dysphagia (external validation). The calibration slopes/intercepts for the PLR, FPC-LR, and FPLS-LR models were 1.6/-0.67, 0.45/0.47, and 0.40/0.49, respectively, for mucositis (internal validation) and 2.5/-0.96, 0.79/-0.04, and 0.79/0.00, respectively, for dysphagia (external validation). The bootstrapped odds ratios indicated significant associations between RT dose and severe toxicity in the mucositis and dysphagia FDA models. Cisplatin was significantly associated with severe dysphagia in the FDA models. None of the covariates was significantly associated with severe toxicity in the PLR models. Dose levels greater than approximately 1.0 Gy/fraction were most strongly associated with severe acute mucositis and dysphagia in the FDA models. CONCLUSIONS: FPLS and functional principal component analysis marginally improved predictive performance compared with PLR and provided robust dose-response associations. FDA is recommended for use in normal tissue complication probability modeling.


Asunto(s)
Trastornos de Deglución/etiología , Neoplasias de Cabeza y Cuello/radioterapia , Modelos Estadísticos , Mucositis/etiología , Órganos en Riesgo/efectos de la radiación , Traumatismos por Radiación/complicaciones , Enfermedad Aguda , Área Bajo la Curva , Carboplatino/efectos adversos , Cisplatino/efectos adversos , Relación Dosis-Respuesta en la Radiación , Humanos , Análisis de Componente Principal , Curva ROC , Fármacos Sensibilizantes a Radiaciones/efectos adversos , Dosificación Radioterapéutica , Análisis de Regresión
7.
Radiother Oncol ; 119(1): 166-71, 2016 04.
Artículo en Inglés | MEDLINE | ID: mdl-26970676

RESUMEN

BACKGROUND AND PURPOSE: Current oral mucositis normal tissue complication probability models, based on the dose distribution to the oral cavity volume, have suboptimal predictive power. Improving the delineation of the oral mucosa is likely to improve these models, but is resource intensive. We developed and evaluated fully-automated atlas-based segmentation (ABS) of a novel delineation technique for the oral mucosal surfaces. MATERIAL AND METHODS: An atlas of mucosal surface contours (MSC) consisting of 46 patients was developed. It was applied to an independent test cohort of 10 patients for whom manual segmentation of MSC structures, by three different clinicians, and conventional outlining of oral cavity contours (OCC), by an additional clinician, were also performed. Geometric comparisons were made using the dice similarity coefficient (DSC), validation index (VI) and Hausdorff distance (HD). Dosimetric comparisons were carried out using dose-volume histograms. RESULTS: The median difference, in the DSC and HD, between automated-manual comparisons and manual-manual comparisons were small and non-significant (-0.024; p=0.33 and -0.5; p=0.88, respectively). The median VI was 0.086. The maximum normalised volume difference between automated and manual MSC structures across all of the dose levels, averaged over the test cohort, was 8%. This difference reached approximately 28% when comparing automated MSC and OCC structures. CONCLUSIONS: Fully-automated ABS of MSC is suitable for use in radiotherapy dose-response modelling.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Mucosa Bucal/efectos de la radiación , Órganos en Riesgo , Atlas como Asunto , Relación Dosis-Respuesta en la Radiación , Humanos , Radiometría/métodos , Dosificación Radioterapéutica
8.
Radiother Oncol ; 115(1): 63-6, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25779721

RESUMEN

There is currently no standard method for delineating the oral mucosa and most attempts are oversimplified. A new method to obtain anatomically accurate contours of the oral mucosa surfaces was developed and applied to 11 patients. This is expected to represent an opportunity for improved toxicity modelling of oral mucositis.


Asunto(s)
Mucosa Bucal/anatomía & histología , Mucosa Bucal/efectos de la radiación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Estomatitis/etiología , Humanos , Planificación de la Radioterapia Asistida por Computador/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA