Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 57(6): 1908-1921, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36218321

RESUMEN

BACKGROUND: Free-breathing 1 H ventilation MRI shows promise but only single-center validation has yet been performed against methods which directly image lung ventilation in patients with cystic fibrosis (CF). PURPOSE: To investigate the relationship between 129 Xe and 1 H ventilation images using data acquired at two centers. STUDY TYPE: Sequence comparison. POPULATION: Center 1; 24 patients with CF (12 female) aged 9-47 years. Center 2; 7 patients with CF (6 female) aged 13-18 years, and 6 healthy controls (6 female) aged 21-31 years. Data were acquired in different patients at each center. FIELD STRENGTH/SEQUENCE: 1.5 T, 3D steady-state free precession and 2D spoiled gradient echo. ASSESSMENT: Subjects were scanned with 129 Xe ventilation and 1 H free-breathing MRI and performed pulmonary function tests. Ventilation defect percent (VDP) was calculated using linear binning and images were visually assessed by H.M., L.J.S., and G.J.C. (10, 5, and 8 years' experience). STATISTICAL TESTS: Correlations and linear regression analyses were performed between 129 Xe VDP, 1 H VDP, FEV1 , and LCI. Bland-Altman analysis of 129 Xe VDP and 1 H VDP was carried out. Differences in metrics were assessed using one-way ANOVA or Kruskal-Wallis tests. RESULTS: 129 Xe VDP and 1 H VDP correlated strongly with; each other (r = 0.84), FEV1 z-score (129 Xe VDP r = -0.83, 1 H VDP r = -0.80), and LCI (129 Xe VDP r = 0.91, 1 H VDP r = 0.82). Bland-Altman analysis of 129 Xe VDP and 1 H VDP from both centers had a bias of 0.07% and limits of agreement of -16.1% and 16.2%. Linear regression relationships of VDP with FEV1 were not significantly different between 129 Xe and 1 H VDP (P = 0.08), while 129 Xe VDP had a stronger relationship with LCI than 1 H VDP. DATA CONCLUSION: 1 H ventilation MRI shows large-scale agreement with 129 Xe ventilation MRI in CF patients with established lung disease but may be less sensitive to subtle ventilation changes in patients with early-stage lung disease. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Fibrosis Quística , Humanos , Femenino , Fibrosis Quística/diagnóstico por imagen , Ventilación Pulmonar , Pulmón/diagnóstico por imagen , Respiración , Imagen por Resonancia Magnética/métodos , Isótopos de Xenón
2.
Eur Radiol ; 33(7): 4767-4779, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36826502

RESUMEN

OBJECTIVES: Follow-up of congenital lung abnormalities (CLA) is currently done with chest computer tomography (CT). Major disadvantages of CT are exposure to ionizing radiation and need for contrast enhancement to visualise vascularisation. Chest magnetic resonance imaging (MRI) could be a safe alternative to image CLA without using contrast agents. The objective of this cohort study was to develop a non-contrast MRI protocol for the follow-up of paediatric CLA patients, and to compare findings on MRI to postnatal CT in school age CLA patients. METHODS: Twenty-one CLA patients, 4 after surgical resection and 17 unoperated (mean age 12.8 (range 9.4-15.9) years), underwent spirometry and chest MRI. MRI was compared to postnatal CT on appearance and size of the lesion, and lesion associated abnormalities, such as hyperinflation and atelectasis. RESULTS: By comparing school-age chest MRI to postnatal CT, radiological appearance and diagnostic interpretation of the type of lesion changed in 7 (41%) of the 17 unoperated patients. In unoperated patients, the relative size of the lesion in relation to the total lung volume remained stable (0.9% (range - 6.2 to + 6.7%), p = 0.3) and the relative size of lesion-associated parenchymal abnormalities decreased (- 2.2% (range - 0.8 to + 2.8%), p = 0.005). CONCLUSION: Non-contrast-enhanced chest MRI was able to identify all CLA-related lung abnormalities. Changes in radiological appearance between MRI and CT were related to CLA changes, patients' growth, and differences between imaging modalities. Further validation is needed for MRI to be introduced as a safe imaging method for the follow-up of paediatric CLA patients. KEY POINTS: • Non-contrast-enhanced chest MRI is able to identify anatomical lung changes related to congenital lung abnormalities, including vascularisation. • At long-term follow-up, the average size of congenital lung abnormalities in relation to normal lung volume remains stable. • At long-term follow-up, the average size of congenital lung abnormalities associated parenchymal abnormalities such as atelectasis in relation to normal lung volume decreases.


Asunto(s)
Bivalvos , Atelectasia Pulmonar , Humanos , Niño , Animales , Adolescente , Estudios de Cohortes , Tomografía Computarizada por Rayos X/métodos , Pulmón/patología , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética
3.
Neuroimage ; 245: 118752, 2021 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-34823024

RESUMEN

AIMS: Non-invasive measures of brain iron content would be of great benefit in neurodegeneration with brain iron accumulation (NBIA) to serve as a biomarker for disease progression and evaluation of iron chelation therapy. Although magnetic resonance imaging (MRI) provides several quantitative measures of brain iron content, none of these have been validated for patients with a severely increased cerebral iron burden. We aimed to validate R2* as a quantitative measure of brain iron content in aceruloplasminemia, the most severely iron-loaded NBIA phenotype. METHODS: Tissue samples from 50 gray- and white matter regions of a postmortem aceruloplasminemia brain and control subject were scanned at 1.5 T to obtain R2*, and biochemically analyzed with inductively coupled plasma mass spectrometry. For gray matter samples of the aceruloplasminemia brain, sample R2* values were compared with postmortem in situ MRI data that had been obtained from the same subject at 3 T - in situ R2*. Relationships between R2* and tissue iron concentration were determined by linear regression analyses. RESULTS: Median iron concentrations throughout the whole aceruloplasminemia brain were 10 to 15 times higher than in the control subject, and R2* was linearly associated with iron concentration. For gray matter samples of the aceruloplasminemia subject with an iron concentration up to 1000 mg/kg, 91% of variation in R2* could be explained by iron, and in situ R2* at 3 T and sample R2* at 1.5 T were highly correlated. For white matter regions of the aceruloplasminemia brain, 85% of variation in R2* could be explained by iron. CONCLUSIONS: R2* is highly sensitive to variations in iron concentration in the severely iron-loaded brain, and might be used as a non-invasive measure of brain iron content in aceruloplasminemia and potentially other NBIA disorders.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Ceruloplasmina/deficiencia , Trastornos del Metabolismo del Hierro/diagnóstico por imagen , Trastornos del Metabolismo del Hierro/metabolismo , Hierro/metabolismo , Imagen por Resonancia Magnética/métodos , Enfermedades Neurodegenerativas/diagnóstico por imagen , Enfermedades Neurodegenerativas/metabolismo , Autopsia , Ceruloplasmina/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Fenotipo
4.
Basic Res Cardiol ; 116(1): 51, 2021 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-34510273

RESUMEN

Pulmonary hypertension is common in heart failure with preserved ejection fraction (HFpEF). Here, we tested the hypothesis that comorbidities [diabetes mellitus (DM, streptozotocin), hypercholesterolemia (HC, high-fat diet) and chronic kidney disease (CKD, renal microembolization)] directly impair pulmonary vasomotor control in a DM + HC + CKD swine model. 6 months after induction of DM + HC + CKD, pulmonary arterial pressure was similar in chronically instrumented female DM + HC + CKD (n = 19) and Healthy swine (n = 18). However, cardiac output was lower both at rest and during exercise, implying an elevated pulmonary vascular resistance (PVR) in DM + HC + CKD swine (153 ± 10 vs. 122 ± 9 mmHg∙L-1∙min∙kg). Phosphodiesterase 5 inhibition and endothelin receptor antagonism decreased PVR in DM + HC + CKD (- 12 ± 12 and - 22 ± 7 mmHg∙L-1∙min∙kg) but not in Healthy swine (- 1 ± 12 and 2 ± 14 mmHg∙L-1∙min∙kg), indicating increased vasoconstrictor influences of phosphodiesterase 5 and endothelin. Inhibition of nitric oxide synthase produced pulmonary vasoconstriction that was similar in Healthy and DM + HC + CKD swine, but unmasked a pulmonary vasodilator effect of endothelin receptor antagonism in Healthy (- 56 ± 26 mmHg∙L-1∙min∙kg), whereas it failed to significantly decrease PVR in DM + HC + CKD, indicating loss of nitric oxide mediated inhibition of endothelin in DM + HC + CKD. Scavenging of reactive oxygen species (ROS) had no effect on PVR in either Healthy or DM + HC + CKD swine. Cardiovascular magnetic resonance imaging, under anesthesia, showed no right ventricular changes. Finally, despite an increased contribution of endogenous nitric oxide to vasomotor tone regulation in the systemic vasculature, systemic vascular resistance at rest was higher in DM + HC + CKD compared to Healthy swine (824 ± 41 vs. 698 ± 35 mmHg∙L-1∙min∙kg). ROS scavenging induced systemic vasodilation in DM + HC + CKD, but not Healthy swine. In conclusion, common comorbidities directly alter pulmonary vascular control, by enhanced PDE5 and endothelin-mediated vasoconstrictor influences, well before overt left ventricular backward failure or pulmonary hypertension develop.


Asunto(s)
Insuficiencia Cardíaca , Animales , Antagonistas de los Receptores de Endotelina/farmacología , Femenino , Óxido Nítrico , Volumen Sistólico , Porcinos , Vasoconstricción , Vasodilatadores
5.
Eur Radiol ; 31(6): 3846-3855, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33219845

RESUMEN

OBJECTIVES: The aim of this study was to assess the effect of a deep learning (DL)-based reconstruction algorithm on late gadolinium enhancement (LGE) image quality and to evaluate its influence on scar quantification. METHODS: Sixty patients (46 ± 17 years, 50% male) with suspected or known cardiomyopathy underwent CMR. Short-axis LGE images were reconstructed using the conventional reconstruction and a DL network (DLRecon) with tunable noise reduction (NR) levels from 0 to 100%. Image quality of standard LGE images and DLRecon images with 75% NR was scored using a 5-point scale (poor to excellent). In 30 patients with LGE, scar size was quantified using thresholding techniques with different standard deviations (SD) above remote myocardium, and using full width at half maximum (FWHM) technique in images with varying NR levels. RESULTS: DLRecon images were of higher quality than standard LGE images (subjective quality score 3.3 ± 0.5 vs. 3.6 ± 0.7, p < 0.001). Scar size increased with increasing NR levels using the SD methods. With 100% NR level, scar size increased 36%, 87%, and 138% using 2SD, 4SD, and 6SD quantification method, respectively, compared to standard LGE images (all p values < 0.001). However, with the FWHM method, no differences in scar size were found (p = 0.06). CONCLUSIONS: LGE image quality improved significantly using a DL-based reconstruction algorithm. However, this algorithm has an important impact on scar quantification depending on which quantification technique is used. The FWHM method is preferred because of its independency of NR. Clinicians should be aware of this impact on scar quantification, as DL-based reconstruction algorithms are being used. KEY POINTS: • The image quality based on (subjective) visual assessment and image sharpness of late gadolinium enhancement images improved significantly using a deep learning-based reconstruction algorithm that aims to reconstruct high signal-to-noise images using a denoising technique. • Special care should be taken when scar size is quantified using thresholding techniques with different standard deviations above remote myocardium because of the large impact of these advanced image enhancement algorithms. • The full width at half maximum method is recommended to quantify scar size when deep learning algorithms based on noise reduction are used, as this method is the least sensitive to the level of noise and showed the best agreement with visual late gadolinium enhancement assessment.


Asunto(s)
Aprendizaje Profundo , Gadolinio , Algoritmos , Cicatriz/diagnóstico por imagen , Cicatriz/patología , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen , Imagen por Resonancia Magnética , Masculino , Miocardio/patología
6.
Recent Results Cancer Res ; 216: 31-110, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32594384

RESUMEN

Imaging in Oncology is rapidly moving from the detection and size measurement of a lesion to the quantitative assessment of metabolic processes and cellular and molecular interactions. Increasing insights into cancer as a complex disease with involvement of the tumor stroma in tumor pathobiological processes have made it clear that for successful control of cancer, treatment strategies should not only be directed at the cancer cells but should also take aspects of the tumor microenvironment into account. This requires an understanding of the complex molecular and cellular interactions in cancer tissue. Recent developments in imaging technology have increased the possibility to image various pathobiological processes in cancer development and response to treatment. For computed tomography (CT) and magnetic resonance imaging (MRI) various improvements in hardware, software, and imaging probes have lifted these modalities from classical anatomical imaging techniques to techniques suitable to image and quantify various physiological processes and molecular and cellular interactions. Next to a more general overview of possible imaging targets in oncology, this chapter provides an overview of the various developments in CT and MRI technology and some specific applications.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Humanos , Oncología Médica
7.
J Cardiovasc Magn Reson ; 22(1): 68, 2020 09 17.
Artículo en Inglés | MEDLINE | ID: mdl-32938483

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) phase contrast (PC) flow measurements suffer from phase offset errors. Background subtraction based on stationary phantom measurements can most reliably be used to overcome this inaccuracy. Stationary tissue correction is an alternative and does not require additional phantom scanning. The aim of this study was 1) to compare measurements with and without stationary tissue correction to phantom corrected measurements on different GE Healthcare CMR scanners using different software packages and 2) to evaluate the clinical implications of these methods. METHODS: CMR PC imaging of both the aortic and pulmonary artery flow was performed in patients on three different 1.5 T CMR scanners (GE Healthcare) using identical scan parameters. Uncorrected, first, second and third order stationary tissue corrected flow measurement were compared to phantom corrected flow measurements, our reference method, using Medis QFlow, Circle cvi42 and MASS software. The optimal (optimized) stationary tissue order was determined per scanner and software program. Velocity offsets, net flow, clinically significant difference (deviation > 10% net flow), and regurgitation severity were assessed. RESULTS: Data from 175 patients (28 (17-38) years) were included, of which 84% had congenital heart disease. First, second and third order and optimized stationary tissue correction did not improve the velocity offsets and net flow measurements. Uncorrected measurements resulted in the least clinically significant differences in net flow compared to phantom corrected data. Optimized stationary tissue correction per scanner and software program resulted in net flow differences (> 10%) in 19% (MASS) and 30% (Circle cvi42) of all measurements compared to 18% (MASS) and 23% (Circle cvi42) with no correction. Compared to phantom correction, regurgitation reclassification was the least common using uncorrected data. One CMR scanner performed worse and significant net flow differences of > 10% were present both with and without stationary tissue correction in more than 30% of all measurements. CONCLUSION: Phase offset errors had a significant impact on net flow quantification, regurgitation assessment and varied greatly between CMR scanners. Background phase correction using stationary tissue correction worsened accuracy compared to no correction on three GE Healthcare CMR scanners. Therefore, careful assessment of phase offset errors at each individual scanner is essential to determine whether routine use of phantom correction is necessary. TRIAL REGISTRATION: Observational Study.


Asunto(s)
Aorta/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Hemodinámica , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética/instrumentación , Arteria Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Adolescente , Adulto , Aorta/fisiopatología , Insuficiencia de la Válvula Aórtica/fisiopatología , Velocidad del Flujo Sanguíneo , Niño , Femenino , Cardiopatías Congénitas/fisiopatología , Humanos , Masculino , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Arteria Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/fisiopatología , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Adulto Joven
8.
Eur Radiol ; 29(6): 2770-2782, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30519932

RESUMEN

OBJECTIVES: This study was conducted in order to evaluate the effect of geometric distortion (GD) on MRI lung volume quantification and evaluate available manual, semi-automated, and fully automated methods for lung segmentation. METHODS: A phantom was scanned with MRI and CT. GD was quantified as the difference in phantom's volume between MRI and CT, with CT as gold standard. Dice scores were used to measure overlap in shapes. Furthermore, 11 subjects from a prospective population-based cohort study each underwent four chest MRI acquisitions. The resulting 44 MRI scans with 2D and 3D Gradwarp were used to test five segmentation methods. Intraclass correlation coefficient, Bland-Altman plots, Wilcoxon, Mann-Whitney U, and paired t tests were used for statistics. RESULTS: Using phantoms, volume differences between CT and MRI varied according to MRI positions and 2D and 3D Gradwarp correction. With the phantom located at the isocenter, MRI overestimated the volume relative to CT by 5.56 ± 1.16 to 6.99 ± 0.22% with body and torso coils, respectively. Higher Dice scores and smaller intraobject differences were found for 3D Gradwarp MR images. In subjects, semi-automated and fully automated segmentation tools showed high agreement with manual segmentations (ICC = 0.971-0.993 for end-inspiratory scans; ICC = 0.992-0.995 for end-expiratory scans). Manual segmentation time per scan was approximately 3-4 h and 2-3 min for fully automated methods. CONCLUSIONS: Volume overestimation of MRI due to GD can be quantified. Semi-automated and fully automated segmentation methods allow accurate, reproducible, and fast lung volume quantification. Chest MRI can be a valid radiation-free imaging modality for lung segmentation and volume quantification in large cohort studies. KEY POINTS: • Geometric distortion varies according to MRI setting and patient positioning. • Automated segmentation methods allow fast and accurate lung volume quantification. • MRI is a valid radiation-free alternative to CT for quantitative data analysis.


Asunto(s)
Imagenología Tridimensional/métodos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Niño , Estudios de Cohortes , Femenino , Humanos , Mediciones del Volumen Pulmonar/métodos , Masculino , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados
9.
Basic Res Cardiol ; 112(3): 28, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28386775

RESUMEN

Despite early revascularization, remodeling and dysfunction of the left ventricle (LV) after acute myocardial infarction (AMI) remain important therapeutic targets. Intermittent pacing therapy (IPT) of the LV can limit infarct size, when applied during early reperfusion. However, the effects of IPT on post-AMI LV remodeling and infarct healing are unknown. We therefore investigated the effects of IPT on global LV remodeling and infarct geometry in swine with a 3-day old AMI. For this purpose, fifteen pigs underwent 2 h ligation of the left circumflex coronary artery followed by reperfusion. An epicardial pacing lead was implanted in the peri-infarct zone. After three days, global LV remodeling and infarct geometry were assessed using magnetic resonance imaging (MRI). Animals were stratified into MI control and IPT groups. Thirty-five days post-AMI, follow-up MRI was obtained and myofibroblast content, markers of extracellular matrix (ECM) turnover and Wnt/frizzled signaling in infarct and non-infarct control tissue were studied. Results showed that IPT had no significant effect on global LV remodeling, function or infarct mass, but modulated infarct healing. In MI control pigs, infarct mass reduction was principally due to a 26.2 ± 4.4% reduction in infarct thickness (P ≤ 0.05), whereas in IPT pigs it was mainly due to a 35.7 ± 4.5% decrease in the number of infarct segments (P ≤ 0.05), with no significant change in infarct thickness. Myofibroblast content of the infarct zone was higher in IPT (10.9 ± 2.1%) compared to MI control (5.4 ± 1.6%; P ≤ 0.05). Higher myofibroblast presence did not coincide with alterations in expression of genes involved in ECM turnover or Wnt/frizzled signaling at 5 weeks follow-up. Taken together, IPT limited infarct expansion and altered infarct composition, showing that IPT influences remodeling of the infarct zone, likely by increasing regional myofibroblast content.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Infarto del Miocardio/patología , Remodelación Ventricular , Animales , Modelos Animales de Enfermedad , Femenino , Imagen por Resonancia Magnética , Masculino , Reacción en Cadena de la Polimerasa , Distribución Aleatoria , Porcinos
10.
Pediatr Radiol ; 45(13): 1901-15, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26342643

RESUMEN

Pediatric chest MRI is challenging. High-resolution scans of the lungs and airways are compromised by long imaging times, low lung proton density and motion. Low signal is a problem of normal lung. Lung abnormalities commonly cause increased signal intenstities. Among the most important factors for a successful MRI is patient cooperation, so the long acquisition times make patient preparation crucial. Children usually have problems with long breath-holds and with the concept of quiet breathing. Young children are even more challenging because of higher cardiac and respiratory rates giving motion blurring. For these reasons, CT has often been preferred over MRI for chest pediatric imaging. Despite its drawbacks, MRI also has advantages over CT, which justifies its further development and clinical use. The most important advantage is the absence of ionizing radiation, which allows frequent scanning for short- and long-term follow-up studies of chronic diseases. Moreover, MRI allows assessment of functional aspects of the chest, such as lung perfusion and ventilation, or airways and diaphragm mechanics. In this review, we describe the most common MRI acquisition techniques on the verge of clinical translation, their problems and the possible solutions to make chest MRI feasible in children.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Enfermedades Respiratorias/diagnóstico , Niño , Humanos , Enfermedades Pulmonares/diagnóstico , Tomografía Computarizada por Rayos X
11.
J Obstet Gynaecol Res ; 40(4): 1051-8, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24428703

RESUMEN

AIM: The aim of this study was to determine whether an optimized 3.0-Tesla magnetic resonance imaging (MRI) protocol is sensitive and specific enough to detect patients with endometriosis. MATERIAL AND METHODS: This was a prospective cohort study with consecutive patients. Forty consecutive patients with clinical suspicion of endometriosis underwent 3.0-Tesla MRI, including a T2-weighted high-resolution fast spin echo sequence (spatial resolution=0.75 ×1.2 ×1.5 mm³) and a 3D T1-weighted high-resolution gradient echo sequence (spatial resolution=0.75 ×1.2 × 2.0 mm³). Two radiologists reviewed the dataset with consensus reading. During laparoscopy, which was used as reference standard, all lesions were characterized according to the revised criteria of the American Fertility Society. Patient-level and region-level sensitivities and specificities and lesion-level sensitivities were calculated. RESULTS: Patient-level sensitivity was 42% for stage I (5/12) and 100% for stages II, III and IV (25/25). Patient-level specificity for all stages was 100% (3/3). The region-level sensitivity and specificity was 63% and 97%, respectively. The sensitivity per lesion was 61% (90% for deep lesions, 48% for superficial lesions and 100% for endometriomata). The detection rate of obliteration of the cul-the-sac was 100% (10/10) with no false positive findings. The interreader agreement was substantial to perfect (kappa=1 per patient, 0.65 per lesion and 0.71 for obliteration of the cul-the-sac). CONCLUSIONS: An optimized 3.0-Tesla MRI protocol is accurate in detecting stage II to stage IV endometriosis.


Asunto(s)
Endometriosis/diagnóstico , Enfermedades del Ovario/diagnóstico , Enfermedades Peritoneales/diagnóstico , Adolescente , Adulto , Estudios de Cohortes , Endometriosis/fisiopatología , Endometriosis/cirugía , Femenino , Humanos , Imagenología Tridimensional/instrumentación , Laparoscopía , Imagen por Resonancia Magnética/instrumentación , Países Bajos , Enfermedades del Ovario/fisiopatología , Enfermedades del Ovario/cirugía , Enfermedades Peritoneales/fisiopatología , Enfermedades Peritoneales/cirugía , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Imagen de Cuerpo Entero , Adulto Joven
12.
Recent Results Cancer Res ; 187: 3-63, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23179877

RESUMEN

Imaging in Oncology is rapidly moving from the detection and size measurement of a lesion to the quantitative assessment of metabolic processes and cellular and molecular interactions. Increasing insights into cancer as a complex disease with involvement of the tumor stroma in tumor pathobiological processes have made it clear that for successful control of cancer, treatment strategies should not only be directed at the tumor cells but also targeted at the tumor microenvironment. This requires understanding of the complex molecular and cellular interactions in cancer tissue. Recent developments in imaging technology have increased the possibility to image various pathobiological processes in cancer development and response to treatment. For computed tomography (CT) and magnetic resonance imaging (MRI) various improvements in hardware, software, and imaging probes have lifted these modalities from classical anatomical imaging techniques to techniques suitable to image and quantify various physiological processes and molecular and cellular interactions. Next to a more general overview of possible imaging targets in oncology this chapter provides an overview of the various developments in CT and MRI technology and some specific applications.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias/patología , Tomografía Computarizada por Rayos X/métodos , Humanos , Neoplasias/diagnóstico por imagen
13.
Pediatr Pulmonol ; 57(12): 2981-2991, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35982507

RESUMEN

BACKGROUND AND OBJECTIVE: The most common respiratory complication of prematurity is bronchopulmonary dysplasia (BPD), leading to structural lung changes and impaired respiratory outcomes. However, also preterm children without BPD may show similar adverse respiratory outcomes. There is a need for a safe imaging modality for preterm children with and without BPD for disease severity assessment and risk stratification. Our objective was to develop a magnetic resonance imaging (MRI) protocol in preterm children with and without BPD at school age. METHODS: Nine healthy volunteers (median age 11.6 [range: 8.8-12.8] years), 11 preterm children with BPD (11.0 [7.2-15.6] years), and 9 without BPD (11.1 [10.7-12.6] years) underwent MRI. Images were scored on hypo- and hyperintense abnormalities, bronchopathy, and architectural distortion. MRI data were correlated to spirometry. Ventilation and perfusion defects were analyzed using Fourier Decomposition (FD) MRI. RESULTS: On MRI, children with BPD had higher %diseased lung (9.1 (interquartile range [IQR] 5.9-11.6)%) compared to preterm children without BPD (3.4 (IQR 2.5-5.4)%, p < 0.001) and healthy volunteers (0.4 (IQR 0.1-0.8)%, p < 0.001). %Diseased lung correlated negatively with %predicted FEV1 (r = -0.40, p = 0.04), FEV1 /FVC (r = -0.49, p = 0.009) and FEF75 (r = -0.63, p < 0.001). Ventilation and perfusion defects on FD sequence corresponded to hypointense regions on expiratory MRI. CONCLUSION: Chest MRI can identify structural and functional lung damage at school age in preterm children with and without BPD, showing a good correlation with spirometry. We propose MRI as a sensitive and safe imaging method (without ionizing radiation, contrast agents, or the use of anesthesia) for the long-term follow-up of preterm children.


Asunto(s)
Displasia Broncopulmonar , Recién Nacido , Niño , Humanos , Displasia Broncopulmonar/diagnóstico por imagen , Volumen Espiratorio Forzado , Estudios de Factibilidad , Estudios de Seguimiento , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética
14.
Neuroradiology ; 53(8): 553-63, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20924757

RESUMEN

INTRODUCTION: After minor head injury (MHI), post-concussive symptoms commonly occur. The purpose of this study was to correlate the severity of post-concussive symptoms in MHI patients with MRI measures of microstructural brain injury, namely mean diffusivity (MD) and fractional anisotropy (FA), as well as the presence of microhaemorrhages. METHODS: Twenty MHI patients and 12 healthy controls were scanned at 3 T using diffusion tensor imaging (DTI) and high-resolution gradient recalled echo (HRGRE) T2*-weighted sequences. One patient was excluded from the analysis because of bilateral subdural haematomas. DTI data were preprocessed using Tract Based Spatial Statistics. The resulting MD and FA images were correlated with the severity of post-concussive symptoms evaluated with the Rivermead Postconcussion Symptoms Questionnaire. The number and location of microhaemorrhages were assessed on the HRGRE T2*-weighted images. RESULTS: Comparing patients with controls, there were no differences in MD. FA was decreased in the right temporal subcortical white matter. MD was increased in association with the severity of post-concussive symptoms in the inferior fronto-occipital fasciculus (IFO), the inferior longitudinal fasciculus and the superior longitudinal fasciculus. FA was reduced in association with the severity of post-concussive symptoms in the uncinate fasciculus, the IFO, the internal capsule and the corpus callosum, as well as in the parietal and frontal subcortical white matter. Microhaemorrhages were observed in one patient only. CONCLUSIONS: The severity of post-concussive symptoms after MHI was significantly correlated with a reduction of white matter integrity, providing evidence of microstructural brain injury as a neuropathological substrate of the post-concussion syndrome.


Asunto(s)
Lesiones Encefálicas/patología , Hemorragia Cerebral/patología , Traumatismos Craneocerebrales/patología , Imagen de Difusión por Resonancia Magnética/métodos , Fibras Nerviosas Mielínicas/patología , Síndrome Posconmocional/patología , Adolescente , Adulto , Lesiones Encefálicas/etiología , Hemorragia Cerebral/etiología , Traumatismos Craneocerebrales/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
15.
Quant Imaging Med Surg ; 11(4): 1247-1255, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33816164

RESUMEN

BACKGROUND: T2 mapping is increasingly used to quantify cartilage degeneration in knee osteoarthritis (OA), yet reproducibility studies in a multicenter setting are limited. The purpose of this study was to determine the longitudinal reproducibility and multicenter variation of cartilage T2 mapping, using various MRI equipment and acquisition protocols. METHODS: In this prospective multicenter study, four traveling, healthy human subjects underwent T2 mapping twice at five different centers with a 6-month-interval. Centers had various MRI scanners, field strengths, and T2 mapping acquisition protocols. Mean T2 values were calculated in six cartilage regions of interest (ROIs) as well as an average value per patient. A phantom was scanned once at each center. To evaluate longitudinal reproducibility, intraclass correlation coefficients (ICC), root-mean-square coefficient of variation (RMS-CV), and a Bland-Altman plot were used. To assess the variation of in vivo and phantom T2 values across centers, ANOVA was performed. RESULTS: ICCs of the T2 mapping measurements per ROI and the ROI's combined ranged from 0.73 to 0.91, indicating good to excellent longitudinal reproducibility. RMS-CVs ranged from 1.1% to 1.5% (per ROI) and 0.6% to 1.6% (ROIs combined) across the centers. A Bland-Altman plot did not reveal a systematic error. Evident, but consistent, discrepancies in T2 values were observed across centers, both in vivo and in the phantom. CONCLUSIONS: The results of this study suggest that T2 mapping can be used to longitudinal assess cartilage degeneration in multicenter studies. Given the differences in absolute cartilage T2 values across centers, absolute T2 values derived from various centers in multicenter multivendor trials should not be pooled.

16.
Orphanet J Rare Dis ; 16(1): 21, 2021 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-33413525

RESUMEN

BACKGROUND: In Pompe disease, an inherited metabolic muscle disorder, severe diaphragmatic weakness often occurs. Enzyme replacement treatment is relatively ineffective for respiratory function, possibly because of irreversible damage to the diaphragm early in the disease course. Mildly impaired diaphragmatic function may not be recognized by spirometry, which is commonly used to study respiratory function. In this cross-sectional study, we aimed to identify early signs of diaphragmatic weakness in Pompe patients using chest MRI. METHODS: Pompe patients covering the spectrum of disease severity, and sex and age matched healthy controls were prospectively included and studied using spirometry-controlled sagittal MR images of both mid-hemidiaphragms during forced inspiration. The motions of the diaphragm and thoracic wall were evaluated by measuring thoracic cranial-caudal and anterior-posterior distance ratios between inspiration and expiration. The diaphragm shape was evaluated by measuring the height of the diaphragm curvature. We used multiple linear regression analysis to compare different groups. RESULTS: We included 22 Pompe patients with decreased spirometry results (forced vital capacity in supine position < 80% predicted); 13 Pompe patients with normal spirometry results (forced vital capacity in supine position ≥ 80% predicted) and 18 healthy controls. The mean cranial-caudal ratio was only 1.32 in patients with decreased spirometry results, 1.60 in patients with normal spirometry results and 1.72 in healthy controls (p < 0.001). Anterior-posterior ratios showed no significant differences. The mean height ratios of the diaphragm curvature were 1.41 in patients with decreased spirometry results, 1.08 in patients with normal spirometry results and 0.82 in healthy controls (p = 0.001), indicating an increased curvature of the diaphragm during inspiration in Pompe patients. CONCLUSIONS: Even in early-stage Pompe disease, when spirometry results are still within normal range, the motion of the diaphragm is already reduced and the shape is more curved during inspiration. MRI can be used to detect early signs of diaphragmatic weakness in patients with Pompe disease, which might help to select patients for early intervention to prevent possible irreversible damage to the diaphragm.


Asunto(s)
Enfermedad del Almacenamiento de Glucógeno Tipo II , Estudios Transversales , Enfermedad del Almacenamiento de Glucógeno Tipo II/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Espirometría , Capacidad Vital
17.
Eur Radiol ; 20(2): 255-74, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19672602

RESUMEN

Through labelling of cells with magnetic contrast agents it is possible to follow the fate of transplanted cells in vivo with magnetic resonance imaging (MRI) as has been demonstrated in animal studies as well as in a clinical setting. A large variety of labelling strategies are available that allow for prolonged and sensitive detection of the labelled cells with MRI. The various protocols each harbour specific advantages and disadvantages. In choosing a particular labelling strategy it is also important to ascertain that the labelling procedure does not negatively influence cell functionality, for which a large variety of assays are available. In order to overcome the challenges still faced in fully exploiting the benefits of in vivo cell tracking by MRI a good understanding and standardisation of the procedures and assays used will be crucial.


Asunto(s)
Células Cultivadas/citología , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/tendencias , Técnicas de Sonda Molecular/tendencias , Animales , Humanos , Coloración y Etiquetado/métodos , Coloración y Etiquetado/tendencias
18.
Hum Brain Mapp ; 30(9): 2789-803, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19117278

RESUMEN

After minor head injury (MHI) postconcussive symptoms (PCS) such as memory and attention deficits frequently occur. It has been hypothesised that PCS are caused by microstructural damage to the brain due to shearing injury, which is not detectable with conventional imaging, and may be responsible for a functional deficit. The purpose of this study was to correlate functional magnetic resonance imaging brain activation of working memory and selective attention with PCS. 21 MHI patients and 12 healthy controls were scanned at 3T. Stimulation paradigms were the n-back and Counting Stroop tasks to engage working memory and selective attention, respectively. Functional data analysis consisted of random effects group analyses, correlating brain activation patterns with the severity of PCS as evaluated with the Rivermead postconcussion symptoms questionnaire. At minimal working memory load, activation was seen in patients with greater severity of PCS in the working memory network. With an increase of working memory load, increase of activation was more pronounced in patients with greater severity of PCS. At high and increased working memory load, activation associated with the severity of PCS was seen in the posterior parietal area, parahippocampal gyrus, and posterior cingulate gyrus. Activation related to selective attention processing was increased with greater severity of PCS. The increased activity in relation to working memory and attention, and the recruitment of brain areas outside the working memory network at high working memory load, may be considered a reflection of the brain's compensatory response to microstructural injury in patients with PCS.


Asunto(s)
Trastorno por Déficit de Atención con Hiperactividad/fisiopatología , Encéfalo/fisiopatología , Lesión Axonal Difusa/fisiopatología , Traumatismos Cerrados de la Cabeza/complicaciones , Trastornos de la Memoria/fisiopatología , Síndrome Posconmocional/fisiopatología , Adaptación Fisiológica/fisiología , Adolescente , Adulto , Atención/fisiología , Trastorno por Déficit de Atención con Hiperactividad/etiología , Trastorno por Déficit de Atención con Hiperactividad/patología , Encéfalo/patología , Mapeo Encefálico , Trastornos del Conocimiento/etiología , Trastornos del Conocimiento/patología , Trastornos del Conocimiento/fisiopatología , Lesión Axonal Difusa/patología , Femenino , Lateralidad Funcional/fisiología , Humanos , Imagen por Resonancia Magnética , Masculino , Trastornos de la Memoria/etiología , Trastornos de la Memoria/patología , Memoria a Corto Plazo/fisiología , Persona de Mediana Edad , Red Nerviosa/patología , Red Nerviosa/fisiopatología , Pruebas Neuropsicológicas , Síndrome Posconmocional/patología , Estudios Prospectivos , Recuperación de la Función/fisiología , Encuestas y Cuestionarios , Adulto Joven
19.
Magn Reson Med ; 61(2): 299-306, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19165879

RESUMEN

To evaluate feasibility and diagnostic quality of ultra-short TR/TE two-dimensional (2D) steady state free precession (SSFP) MRI for cystic fibrosis (CF) patients. We performed lung MRI at 1.5 Tesla in 20 CF-patients (6-17 years, 12 males). Axial, coronal, and sagittal sections were acquired in inspiration and expiration with maximum breath-hold time 10 s. MR and CT images were scored using a modified Brody scoring system to assess bronchiectasis, mucous plugging, atelectasis/consolidations, and air trapping. All images were scored by two experienced observers. A complete MR investigation took maximally 15 min. Maximal breath-holds were only 10 s and well tolerated. MRI identified major bronchiectasis, mucous plugging and atelectasis. End-expiratory scans showed patches of parenchyma with reduced signal intensity that may corresponded to areas of trapped air on expiratory CT scans. This MRI protocol based on ultra-short TR/TE 2D SSFP is quick and well tolerated and provides highly relevant imaging features as seen on CT in CF patients. Most importantly, the SNR of the expiratory scans enables to visualize air trapping. The preliminary results of this study suggest MRI as a noteworthy additional imaging tool for routine monitoring of CF patients.


Asunto(s)
Algoritmos , Fibrosis Quística/patología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Pulmón/patología , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Adolescente , Niño , Estudios de Factibilidad , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
20.
PLoS One ; 14(7): e0219291, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31310623

RESUMEN

OBJECTIVES: Autopsy rates worldwide have dropped significantly over the last decades and imaging-based autopsies are increasingly used as an alternative to conventional autopsy. Our aim was to evaluate the clinical performance and cost of minimally invasive autopsy. METHODS: This study was part of a prospective cohort study evaluating a newly implemented minimally invasive autopsy consisting of MRI, CT, and biopsies. We calculated diagnostic yield and clinical utility-defined as the percentage successfully answered clinical questions-of minimally invasive autopsy. We performed minimally invasive autopsy in 46 deceased (30 men, 16 women; mean age 62.9±17.5, min-max: 18-91). RESULTS: Ninety-six major diagnoses were found with the minimally invasive autopsy of which 47/96 (49.0%) were new diagnoses. CT found 65/96 (67.7%) major diagnoses and MRI found 82/96 (85.4%) major diagnoses. Eighty-four clinical questions were asked in all cases. Seventy-one (84.5%) of these questions could be answered with minimally invasive autopsy. CT successfully answered 34/84 (40.5%) clinical questions; in 23/84 (27.4%) without the need for biopsies, and in 11/84 (13.0%) a biopsy was required. MRI successfully answered 60/84 (71.4%) clinical questions, in 27/84 (32.1%) without the need for biopsies, and in 33/84 (39.8%) a biopsy was required. The mean cost of a minimally invasive autopsy was €1296 including brain biopsies and €1087 without brain biopsies. Mean cost of CT was €187 and of MRI €284. CONCLUSIONS: A minimally invasive autopsy, consisting of CT, MRI and CT-guided biopsies, performs well in answering clinical questions and detecting major diagnoses. However, the diagnostic yield and clinical utility were quite low for postmortem CT and MRI as standalone modalities.


Asunto(s)
Autopsia/economía , Autopsia/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Causas de Muerte , Femenino , Hospitales , Humanos , Biopsia Guiada por Imagen/economía , Imagen por Resonancia Magnética/economía , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/economía , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA