Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Infection ; 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38607591

RESUMEN

BACKGROUND: Within endemic regions in southern and eastern Germany, Borna disease virus 1 (BoDV-1) causes rare zoonotic spill-over infections in humans, leading to encephalitis with a high case-fatality risk. So far, intra-vitam diagnosis has mainly been based on RT-qPCR from cerebrospinal fluid (CSF) and serology, both being associated with diagnostic challenges. Whilst low RNA copy numbers in CSF limit the sensitivity of RT-qPCR from this material, seroconversion often occurs late during the course of the disease. CASE PRESENTATION: Here, we report the new case of a 40 - 50 year-old patient in whom the detection of virus-specific T cells via ELISpot corroborated the diagnosis of BoDV-1 infection. The patient showed a typical course of the disease with prodromal symptoms like fever and headaches 2.5 weeks prior to hospital admission, required mechanical ventilation from day three after hospitalisation and remained in deep coma until death ten days after admission. RESULTS: Infection was first detected by positive RT-qPCR from a CSF sample drawn four days after admission (viral load 890 copies/mL). A positive ELISpot result was obtained from peripheral blood collected on day seven, when virus-specific IgG antibodies were not detectable in serum, possibly due to previous immune adsorption for suspected autoimmune-mediated encephalitis. CONCLUSION: This case demonstrates that BoDV-1 ELISpot serves as additional diagnostic tool even in the first week after hospitalisation of patients with BoDV-1 encephalitis.

2.
Ann Neurol ; 88(4): 723-735, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32794235

RESUMEN

OBJECTIVE: The number of diagnosed fatal encephalitis cases in humans caused by the classical Borna disease virus (BoDV-1) has been increasing, ever since it was proved that BoDV-1 can cause human infections. However, awareness of this entity is low, and a specific imaging pattern has not yet been identified. We therefore provide the first comprehensive description of the morphology of human BoDV-1 encephalitis, with histopathological verification of imaging abnormalities. METHODS: In an institutional review board-approved multicenter study, we carried out a retrospective analysis of 55 magnetic resonance imaging (MRI) examinations of 19 patients with confirmed BoDV-1 encephalitis. Fifty brain regions were analyzed systematically (T1w, T2w, T2*w, T1w + Gd, and DWI), in order to discern a specific pattern of inflammation. Histopathological analysis of 25 locations in one patient served as correlation for MRI abnormalities. RESULTS: Baseline imaging, acquired at a mean of 11 ± 10 days after symptom onset, in addition to follow-up scans of 16 patients, revealed characteristic T2 hyperintensities with a predilection for the head of the caudate nucleus, insula, and cortical spread to the limbic system, whereas the occipital lobes and cerebellar hemispheres were unaffected. This gradient was confirmed by histology. Nine patients (47.4%) developed T1 hyperintensities of the basal ganglia, corresponding to accumulated lipid phagocytes on histology and typical for late-stage necrosis. INTERPRETATION: BoDV-1 encephalitis shows a distinct pattern of inflammation in both the early and late stages of the disease. Its appearance can mimic sporadic Creutzfeldt-Jakob disease on MRI and should be considered a differential diagnosis in the case of atypical clinical presentation. ANN NEUROL 2020;88:723-735.


Asunto(s)
Encefalitis Viral/patología , Infecciones por Mononegavirales/patología , Adolescente , Adulto , Anciano , Bornaviridae , Encéfalo/patología , Niño , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Fenotipo , Estudios Retrospectivos , Adulto Joven
3.
Ultraschall Med ; 42(2): 178-186, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32663881

RESUMEN

BACKGROUND: This prospective multicenter study funded by the DEGUM assesses the diagnostic accuracy of standardized contrast-enhanced ultrasound (CEUS) for the noninvasive diagnosis of hepatocellular carcinoma (HCC) in high-risk patients. METHODS: Patients at high risk for HCC with a histologically proven focal liver lesion on B-mode ultrasound were recruited prospectively in a multicenter approach. Clinical and imaging data were entered via online entry forms. The diagnostic accuracies for the noninvasive diagnosis of HCC were compared for the conventional interpretation of standardized CEUS at the time of the examination (= CEUS on-site) and the two CEUS algorithms ESCULAP (Erlanger Synopsis for Contrast-enhanced Ultrasound for Liver lesion Assessment in Patients at risk) and CEUS LI-RADS (Contrast-Enhanced UltraSound Liver Imaging Reporting and Data System). RESULTS: 321 patients were recruited in 43 centers; 299 (93.1 %) had liver cirrhosis. The diagnosis according to histology was HCC in 256 cases, and intrahepatic cholangiocarcinoma (iCCA) in 23 cases. In the subgroup of cirrhotic patients (n = 299), the highest sensitivity for the diagnosis of HCC was achieved with the CEUS algorithm ESCULAP (94.2 %) and CEUS on-site (90.9 %). The lowest sensitivity was reached with the CEUS LI-RADS algorithm (64 %; p < 0.001). However, the specificity of CEUS LI-RADS (78.9 %) was superior to that of ESCULAP (50.9 %) and CEUS on-site (64.9 %; p < 0.001). At the same time, the negative predictive value (NPV) of CEUS LI-RADS was significantly inferior to that of ESCULAP (34.1 % vs. 67.4 %; p < 0.001) and CEUS on-site (62.7 %; p < 0.001). The positive predictive values of all modalities were high (around 90 %), with the best results seen for CEUS LI-RADS and CEUS on-site. CONCLUSION: This is the first multicenter, prospective comparison of standardized CEUS and the recently developed CEUS-based algorithms in histologically proven liver lesions in cirrhotic patients. Our results reaffirm the excellent diagnostic accuracy of CEUS for the noninvasive diagnosis of HCC in high-risk patients. However, on-site diagnosis by an experienced examiner achieves an almost equal diagnostic accuracy compared to CEUS-based diagnostic algorithms.


Asunto(s)
Neoplasias de los Conductos Biliares , Carcinoma Hepatocelular , Neoplasias Hepáticas , Algoritmos , Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Prospectivos , Ultrasonografía
4.
Radiologe ; 61(Suppl 1): 19-28, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34378067

RESUMEN

In multimodal radiologic imaging, contrast-enhanced ultrasound (CEUS) is increasingly used. One of the advantages of CEUS is the possibility of repeated application of contrast media without decreasing renal function or affecting the thyroid gland. Small solid liver lesions can be diagnosed and detected with high accuracy. Moreover, solid lesions in other abdominal organs can also be characterized. Frequent applications for solid lesions in the near field concern thyroid tumors and lymph nodes. For prostate diagnostics, CEUS can be used with an endorectal probe and perfusion imaging. This review explains how the additional (semi-)quantitative perfusion analysis, especially time-intensity curve (TIC) analyses, and wash-in/wash-out kinetics of integrated or external perfusion software programs facilitate new options in dynamic assessment of microvascularization during tumor follow-up care and even minimally invasive tumor therapy.


Asunto(s)
Imagen de Perfusión , Humanos
5.
Medicina (Kaunas) ; 57(9)2021 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-34577905

RESUMEN

Background and Objectives: The standard diagnostic procedure for a patient with a suspected polytrauma injury is computed tomography (CT). In individual cases, however, extended acute imaging using magnetic resonance imaging (MRI) can provide valuable and therapy-relevant information. The aim of our cohort study was to find such cases and to describe their characteristics in order to be able to give possible recommendations for MRI application in acute trauma situations. Materials and Methods: In the study period from 2015-2019, an evaluation of the imaging performed on polytrauma patients was carried out. The specific diagnostic and therapeutic criteria of the MRI group were further defined. Results: In total, 580 patients with an ISS ≥16 (injury severity score) were included in the study. Of these 580 patients, 568 patients received a CT scan and 12 patients an MRI scan as part of the initial diagnostic. Altogether, 66.67% of the MRIs took place outside of regular service hours. The main findings for MRI indications were neurological abnormalities with a focus on myelon injuries. Further MRI examinations were performed to rule out vascular injuries. All in all, 58.3% of the MRIs performed resulted in modified therapeutic strategies afterward. Conclusions: MRI in the context of acute diagnostic of a severely injured patient will likely remain reserved for special indications in the future. However, maximum care hospitals with a high flow of severely injured patients should provide 24/7 MR imaging to ensure the best possible care, especially in neurological and blunt vascular injuries.


Asunto(s)
Imagen por Resonancia Magnética , Heridas no Penetrantes , Estudios de Cohortes , Cuidados Críticos , Humanos , Puntaje de Gravedad del Traumatismo , Estudios Retrospectivos
6.
Ultraschall Med ; 39(4): 440-447, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28946152

RESUMEN

AIM: Using new perfusion software for evaluation of the success of percutaneous treatments of malignant liver tumors with CEUS. MATERIALS AND METHODS: Retrospective analysis of 88 patients (74 male, 14 female; 30 - 84 years) with 165 malignant liver lesions. The lesions were 57 metastases and 108 HCCs. The success of interventional treatment (IRE n = 47; RFA n = 38; MWA n = 44; TACE n = 36) was evaluated by CEUS and perfusion software (VueBox®). CEUS was performed after injection of 1 - 2.4 ml of sulfur hexafluoride microbubbles (SonoVue®) using a 1 - 5 MHz convex probe. DICOM loops up to 1 min. in the ablation area were stored digitally in the PACS. Regions of interest (ROI) were manually placed in the center, the margins of the lesions as well as in the surrounding tissue. Using VueBox® peak, time to peak (TTP), mean transit time (mTT), rise time (RT), the wash-in and wash-out rate were calculated for the regions, in order to evaluate the success of the percutaneous treatment after the ablation in comparison to the ceCT/ceMRI up to 6 months after the treatment. RESULTS: There were significant differences in all cases between the center compared to the margins for the main perfusion parameters (peak, mTT, RT) (p < 0.001). Peak, wash-in and wash-out ratios were further analyzed with the type of lesion and the method of ablation. All parameters were significantly different between lesions treated successfully vs. lesions with recurrence. CONCLUSION: A combination of CEUS with perfusion imaging enables critical assessment of successful treatment after percutaneous interventional procedures for a malignant liver lesion.


Asunto(s)
Neoplasias Hepáticas , Programas Informáticos , Ultrasonografía , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Fosfolípidos , Estudios Retrospectivos , Hexafluoruro de Azufre , Ultrasonografía/métodos
7.
Ultraschall Med ; 38(6): 619-625, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29108077

RESUMEN

AIM: The purpose of this study was to compare contrast-enhanced ultrasound (CEUS), magnetic resonance imaging (MRI) using liver-specific contrast agent and a combination of both for the characterization of focal liver lesions (FLL). METHODS: 83 patients with both benign and malignant liver lesions were examined using CEUS and MRI after the intravenous administration of liver-specific contrast media. All patients had inconclusive results from prior imaging examinations. Histopathological specimens could be obtained in 53 patients. Ultrasound was performed using a multi-frequency curved probe (1 - 6 MHz) after the injection of 1 - 2.4 ml ultrasound contrast media. The sensitivity, specificity, positive predictive value and negative predictive value of CEUS, MRI and a combination of both (CEUS + MRI) were compared. RESULTS: The sensitivity, specificity, positive and negative predictive values regarding lesion classification were 90.9 %, 70.6 %, 92.3 % and 66.6 %, respectively, for CEUS; 90.9 %, 82.4 %, 95.2 % and 70.0 %, respectively, for MRI; and 96.9 %, 70.6 %, 92.7 % and 85.7 % respectively, for CEUS + MRI. There were no statistically significant differences. 6 malignant lesions were missed using CEUS or MRI alone (false negatives). The use of both modalities combined reduced the false-negative results to 2. CONCLUSION: CEUS and MRI with liver-specific contrast media are very reliable and of equal informative value in the characterization of focal liver lesions. The number of false-negative results can be decreased using a combination of the two methods.


Asunto(s)
Neoplasias Hepáticas , Medios de Contraste , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X , Ultrasonografía
9.
Eur Radiol ; 25(5): 1407-12, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25500715

RESUMEN

PURPOSE: To evaluate the clinical value and impact of radiological imaging in published medial case reports. METHODS: We analysed 671 consecutively published case reports of a peer-reviewed medical journal for case reports. The general use of radiological imaging as well as the specific imaging modality used in each case (ultrasound, x-ray, fluoroscopy, CT, MRI) was documented, and most importantly the 'final problem solver', i.e. the diagnostic modality giving the final clue to the patient's diagnosis, was identified. RESULTS: In 511 of 671 (76.1 %) analysed case reports at least one radiological modality was used in the diagnostic cascade. In 28.6% of all cases the final diagnosis was achieved by radiological imaging. All other cases were solved by the patient's history and physical examination (15.2%), histology (12.4%), and blood analysis (9.6%). When radiology was the 'final problem solver', it was mainly CT (51.6%) and MRI (30.6%). In 52.2% of the case reports the radiological image was included in the article. CONCLUSION: In case reports published in a prominent general medical journal radiological imaging is an important key player in the diagnostic process. In many cases, it is also the diagnostic tool which ultimately leads to determining the final diagnosis. KEY POINTS: • Radiology was the most important specialty for finding the final diagnosis. • CT was the most successful problem-solving imaging modality followed by MRI. • MRI and CT had the best solution rates of more than 30%.


Asunto(s)
Diagnóstico por Imagen/métodos , Diagnóstico por Imagen/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Diagnóstico Diferencial , Femenino , Humanos , Lactante , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X , Adulto Joven
10.
Neurooncol Adv ; 6(1): vdae060, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38800697

RESUMEN

Background: Growing research demonstrates the ability to predict histology or genetic information of various malignancies using radiomic features extracted from imaging data. This study aimed to investigate MRI-based radiomics in predicting the primary tumor of brain metastases through internal and external validation, using oversampling techniques to address the class imbalance. Methods: This IRB-approved retrospective multicenter study included brain metastases from lung cancer, melanoma, breast cancer, colorectal cancer, and a combined heterogenous group of other primary entities (5-class classification). Local data were acquired between 2003 and 2021 from 231 patients (545 metastases). External validation was performed with 82 patients (280 metastases) and 258 patients (809 metastases) from the publicly available Stanford BrainMetShare and the University of California San Francisco Brain Metastases Stereotactic Radiosurgery datasets, respectively. Preprocessing included brain extraction, bias correction, coregistration, intensity normalization, and semi-manual binary tumor segmentation. Two-thousand five hundred and twenty-eight radiomic features were extracted from T1w (±â€…contrast), fluid-attenuated inversion recovery (FLAIR), and wavelet transforms for each sequence (8 decompositions). Random forest classifiers were trained with selected features on original and oversampled data (5-fold cross-validation) and evaluated on internal/external holdout test sets using accuracy, precision, recall, F1 score, and area under the receiver-operating characteristic curve (AUC). Results: Oversampling did not improve the overall unsatisfactory performance on the internal and external test sets. Incorrect data partitioning (oversampling before train/validation/test split) leads to a massive overestimation of model performance. Conclusions: Radiomics models' capability to predict histologic or genomic data from imaging should be critically assessed; external validation is essential.

11.
Cancers (Basel) ; 14(19)2022 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-36230668

RESUMEN

BACKGROUND: The aim was to improve preoperative diagnostics of solid non-cystic thyroid lesions by using new high-performance multiparametric ultrasound examination techniques. METHODS: Multiparametric ultrasound consists of B-mode, shear-wave elastography and contrast enhanced ultrasound (CEUS) including Time-Intensity-Curve (TIC) analysis. A bolus of 1-2.4 mL Sulfur Hexafluorid microbubbles was injected for CEUS. Postoperative histopathology was the diagnostic gold standard. RESULTS: 116 patients were included in this study. 102 benign thyroid nodules were diagnosed as well as 20 carcinomas. Suspicious B-mode findings like microcalcifications, a blurry edge and no homogeneous sonomorphological structure were detected in 60, 75 and 80% of all carcinomas but only in 13.7, 36.3 and 46.1% of all benign lesions. The average shear-wave elastography measurements of malignant lesions (4.6 m/s or 69.8 kPa centrally and 4.2 m/s or 60.1 kPa marginally) exceed the values of benign nodules. Suspicious CEUS findings like a not-homogeneous wash-in and a wash-out were detected almost twice as often in carcinomas. CONCLUSION: Multiparametric ultrasound offers new possibilities for the preoperative distinction between benign and malignant thyroid nodules. A score based system of B-mode, shear-wave and CEUS malignancy criteria shows promising results in the detection of thyroid carcinomas. It reaches a sensitivity of 95% and specificity of 75.49%.

12.
Diagnostics (Basel) ; 12(7)2022 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-35885653

RESUMEN

In the management of patients with chronic liver disease, the assessment of liver function is essential for treatment planning. Gd-EOB-DTPA-enhanced MRI allows for both the acquisition of anatomical information and regional liver function quantification. The objective of this study was to demonstrate and evaluate the diagnostic performance of two fully automatically generated imaging-based liver function scores that take the whole liver into account. T1 images from the native and hepatobiliary phases and the corresponding T1 maps from 195 patients were analyzed. A novel artificial-intelligence-based software prototype performed image segmentation and registration, calculated the reduction rate of the T1 relaxation time for the whole liver (rrT1liver) and used it to calculate a personalized liver function score, then generated a unified score-the MELIF score-by combining the liver function score with a patient-specific factor that included weight, height and liver volume. Both scores correlated strongly with the MELD score, which is used as a reference for global liver function. However, MELIF showed a stronger correlation than the rrT1liver score. This study demonstrated that the fully automated determination of total liver function, regionally resolved, using MR liver imaging is feasible, providing the opportunity to use the MELIF score as a diagnostic marker in future prospective studies.

13.
Clin Hemorheol Microcirc ; 78(1): 29-40, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33523044

RESUMEN

The external perfusion software (VueBox™) for contrast-enhanced ultrasound (CEUS), enables the quantitative analysis of micro-vascularization within non-cystic lesions in terms of characterization and detection. This review summarizes our work about parathyroid gland, thyroid gland, liver, prostate and other tissues as well as original studies in the use of parametric perfusion imaging. Useful perfusion parameters are introduced.


Asunto(s)
Medios de Contraste/uso terapéutico , Imagen de Perfusión/métodos , Ultrasonografía/métodos , Femenino , Humanos , Masculino
14.
Sci Rep ; 11(1): 17677, 2021 09 03.
Artículo en Inglés | MEDLINE | ID: mdl-34480040

RESUMEN

The aim of this present clinical pilot study is the display of typical perfusion results in patients with solid, non-cystic breast lesions. The lesions were characterized using contrast enhanced ultrasound (CEUS) with (i) time intensity curve analyses (TIC) and (ii) parametric color maps. The 24 asymptomatic patients included were genetically tested for having an elevated risk for breast cancer. At a center of early detection of familial ovary and breast cancer, those patients received annual MRI and grey-scale ultrasound. If lesions remained unclear or appeared even suspicious, those patients also received CEUS. CEUS was performed after intravenous application of sulfur hexafluoride microbubbles. Digital DICOM cine loops were continuously stored for one minute in PACS (picture archiving and communication system). Perfusion images and TIC analyses were calculated off-line with external perfusion software (VueBox). The lesion diameter ranged between 7 and 15 mm (mean 11 ± 3 mm). Five hypoechoic irregular lesions were scars, 6 lesions were benign and 12 lesions were highly suspicious for breast cancer with irregular enhancement at the margins and a partial wash out. In those 12 cases, histopathology confirmed breast cancer. All the suspicious lesions were correctly identified visually. For the perfusion analysis only Peak Enhancement (PE) and Area Under the Curve (AUC) added more information for correctly identifying the lesions. Typical for benign lesions is a prolonged contrast agent enhancement with lower PE and prolonged wash out, while scars are characterized typically by a reduced enhancement in the center. No differences (p = 0.428) were found in PE in the center of benign lesions (64.2 ± 28.9 dB), malignant lesions (88.1 ± 93.6 dB) and a scar (40.0 ± 17.0 dB). No significant differences (p = 0.174) were found for PE values at the margin of benign lesions (96.4 ± 144.9 dB), malignant lesions (54.3 ± 86.2 dB) or scar tissue (203.8 ± 218.9 dB). Significant differences (p < 0.001) were found in PE of the surrounding tissue when comparing benign lesions (33.6 ± 25.2 dB) to malignant lesions (15.7 ± 36.3 dB) and scars (277.2 ± 199.9 dB). No differences (p = 0.821) were found in AUC in the center of benign lesions (391.3 ± 213.7), malignant lesions (314.7 ± 643.9) and a scar (213.1 ± 124.5). No differences (p = 0.601) were found in AUC values of the margin of benign lesions (313.3 ± 372.8), malignant lesions (272.6 ± 566.4) or scar tissue (695.0 ± 360.6). Significant differences (p < 0.01) were found in AUC of the surrounding tissue for benign lesions (151.7 ± 127.8), malignant lesions (177.9 ± 1345.6) and scars (1091 ± 693.3). There were no differences in perfusion evaluation for mean transit time (mTT), rise time (RT) and time to peak (TTP) when comparing the center to the margins and the surrounding tissue. The CEUS perfusion parameters PE and AUC allow a very good assessment of the risk of malignant breast lesions and thus a downgrading of BI-RADS 4 lesions. The use of the external perfusion software (VueBox, Bracco, Milan, Italy) did not lead to any further improvement in the diagnosis of suspicious breast lesions and does appears not to have any additional diagnostic value in breast lesions.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Ultrasonografía Mamaria , Femenino , Humanos , Imagen por Resonancia Magnética , Proyectos Piloto , Programas Informáticos
15.
Clin Hemorheol Microcirc ; 77(3): 303-310, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33337354

RESUMEN

AIM: The aim of this study was to assess the success of irreversible electroporation (IRE) in prostate cancer and to differentiate between reactive changes and tumor. MATERIAL AND METHODS: This is a retrospective pilot study of 50 patients after irreversible electroporation (IRE) in prostate cancer between 50-79 years (mean age 65 years). Each patient received a transabdominal sonography using a 1-6 MHz convex matrix probe. Contrast-enhanced ultrasound (CEUS) was performed after i.v. bolus injection of 2.0 ml sulphur hexafluoride microbubbles. DICOM loops were continuously stored up to one minute. Parametric images were calculated by integrated perfusion analysis software. A comparison was drawn to a follow-up MRI six months after ablation. RESULTS: While 13 patients showed local recurrence, 37 patients were successfully treated, meaning no local recurrence within six months after ablation. 18 patients showed signs of prostatitis after IRE. Tumorous changes were visually characterized by dynamic early nodular hypervascularization with fast and high wash-in. Correspondingly, nodular red and yellow shades were seen in parametric imaging. All patients with remaining tumor were correctly identified with CEUS and parametric imaging. After IRE there is a relevant decrease in tumor microcirculation in all patients, as seen in more purple shades of the prostate. The sensitivity for detecting residual tumor with CEUS compared to MRI was 76%, the specificity was 81%. The corresponding positive predictive value (PPV) was 73% and the negative predictive value (NPV) was 83%. CONCLUSION: CEUS and parametric imaging enable a critical analysis of post-ablation defects after IRE for prostate cancer even with a transabdominal approach. Remaining tumor can be detected with the help of pseudo-colors.


Asunto(s)
Medios de Contraste/uso terapéutico , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/terapia , Ultrasonografía/métodos , Anciano , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Retrospectivos
16.
PLoS One ; 14(6): e0217599, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31181127

RESUMEN

AIM: Evaluation of an external color coded perfusion quantification software with CEUS for the post-interventional success control following TACE in patients with HCC. MATERIAL AND METHODS: 31 patients (5 females, 26 males, age range 34-82 years, mean 66.8 years) with 59 HCC lesions underwent superselective TACE using DSM Beads between 01/2015 and 06/2018. All patients underwent CEUS by an experienced examiner using a convex multifrequency probe (1-6 MHz) within 24 hours following TACE to detect residual tumor tissue. Retrospective evaluation using a perfusion quantification software regarding pE, TTP, mTT, Ri and WiAUC in the center of the lesion, the margin and surrounding liver. RESULTS: In all lesions, a post-interventional visual reduction of the tumor microvascularization was observed. Significant differences between center of the lesion vs. margin and surrounding liver were found regarding peak enhancement (867.8 ± 2416 center vs 2028 ± 3954 margin p<0.005) and center 867.8 ± 2416 vs 2824 ± 4290 surrounding liver, p<0.0001)). However, no significant differences were found concerning Ri, WiAuC, mTT and TTP. CONCLUSION: CEUS with color- coded perfusion imaging is a valuable supporting tool for post-interventional success control following TACE of liver lesions. Peak enhancement seems to be the most valuable parameter.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen de Perfusión/métodos , Adulto , Anciano , Anciano de 80 o más Años , Quimioembolización Terapéutica/métodos , Medios de Contraste , Femenino , Humanos , Hígado/patología , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Microcirculación , Persona de Mediana Edad , Perfusión/métodos , Estudios Retrospectivos , Ultrasonografía/métodos
17.
J Gastrointestin Liver Dis ; 28(3): 311-318, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31517328

RESUMEN

AIM: Evaluation of the post-interventional success following irreversible electroporation (IRE) using a new color coded perfusion quantification software with contrast-enhanced ultrasound (CEUS) in patients with malignant lesions of the liver. METHODS: Thirty-eight patients with 68 malignant liver lesions underwent IRE. All malignant lesions were investigated with CEUS before and within 24 hours following IRE to detect residual tumor tissue. The parameters analyzed by color coded perfusion quantification software were: the peak enhancement (pE), time to peak (TTP), mean transit time (mTT), rise (Ri) and wash-in area under the curve (WiAUC). Perfusion in the center, the margins of the lesions and in the surrounding liver were evaluated using these parameters. RESULTS: Hepatocellular carcinoma (HCC) with complete ablation showed significantly different changes between the center and the margin of the lesions for WiAUC (p<0.05) and pE (p<0.01). Also significant differences were noted between the center of the lesions and the surrounded tissue for the same parameters (p<0.01). In the completely ablated metastatic lesions, significant differences were found between the center of the lesion and the margins (p < 0.01) and between the center of the lesion and the surrounding liver (p < 0.05) for WiAUC. mTT, TTP and Ri showed no significant changes between the center of the lesions, margin of the lesions or surrounding tissue. Also, no significant differences were found for these parameters in the different regions of interest for HCC or the metastatic lesions with partial ablation success. CONCLUSION: CEUS with perfusion imaging is a valuable supporting tool for the post-interventional evaluation of liver lesions following IRE. Focus should be placed on the peak enhancement (pE) and the wash-in area under the curve (WiAUC).


Asunto(s)
Técnicas de Ablación , Carcinoma Hepatocelular , Medios de Contraste/administración & dosificación , Electroporación , Neoplasias Hepáticas , Imagen de Perfusión/métodos , Fosfolípidos/administración & dosificación , Hexafluoruro de Azufre/administración & dosificación , Ultrasonografía Doppler en Color , Técnicas de Ablación/efectos adversos , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Carcinoma Hepatocelular/irrigación sanguínea , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/cirugía , Femenino , Humanos , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Masculino , Márgenes de Escisión , Microcirculación , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Factores de Tiempo , Resultado del Tratamiento
18.
Clin Hemorheol Microcirc ; 73(1): 73-83, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31561352

RESUMEN

AIM: Evaluation of the post-interventional success following ablative techniques (radiofrequency and microwave) using a new color coded perfusion quantification software with CEUS in patients with primary and secondary liver malignancies. MATERIAL AND METHODS: 75 patients (60 males, 15 females, age 24-84 years, mean 62.7 years) with 128 malignant liver lesions were included in this study. Between 01/2013 and 06/2018, the therapeutic interventional procedure in 88 lesions was MWA, in 40 lesions RFA. All patients underwent CEUS using a convex multifrequency probe (1-6 MHz) following application of 1-2.4 ml sulphur hexaflouride microbubbles, before and within 24 hours following RFA and MWA to detect residual tumor tissue. Postprocessing of the stored DICOM loops from 15 sec up to 1 min using a perfusion quantification software regarding peak enhancement (pE), time to peak (TTP), mean transit time (MTT), rise time (Ri) and Wash-in area under the curve (WiAUC) in the center of the lesion, the border area and periphery was performed. RESULTS: In patients treated with RFA, pE differences between center of the lesion vs. surrounding liver were found to be statistically extremely significant (p < 0.001), differences between center of the lesion and margin were also statistically significant (p < 0.01). mTT, TTP, WiAuC and Ri showed no significant difference between center, margin or surrounding liver.In patients treated with MWA, statistically significant differences (p < 0.05) were found for pE, Ri and mTT regarding the differences between center of lesion and surrounding tissue. WiAuC and TTP showed no significant differences between center, margin or surrounding liver. CONCLUSION: CEUS with perfusion imaging is a valuable supporting tool for post-interventional success control following RFA and MWA of primary and secondary liver maligancies. Focus should be placed upon pE following MWA and pE, Ri and mTT following RFA.


Asunto(s)
Técnicas de Ablación/métodos , Medios de Contraste/uso terapéutico , Neoplasias Hepáticas/diagnóstico por imagen , Ablación por Radiofrecuencia/métodos , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Perfusión/métodos , Adulto Joven
19.
Cancer Manag Res ; 11: 317-322, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30643457

RESUMEN

BACKGROUND: For colorectal liver metastases (CRLM) that are not amenable to surgery or thermal ablation, irreversible electroporation (IRE) is a novel local treatment modality and additional option. METHODS: This study is a retrospective long-term follow-up of patients with CRLM who underwent IRE as salvage treatment. RESULTS: Of the 24 included patients, 18 (75.0%) were male, and the median age was 57 (range: 28-75) years. The mean time elapsed from diagnosis to IRE was 37.9±37.3 months. Mean overall survival was 26.5 months after IRE (range: 2.5-69.2 months) and 58.1 months after diagnosis (range: 14.8-180.1 months). One-, three-, and five-year survival rates after initial diagnosis were 100.0%, 79.2%, and 41.2%; after IRE, the respective survival rates were 79.1%, 25.0%, and 8.3%. There were no statistically significant differences detected in survival after IRE with respect to gender, age, T- or N-stage at the time of diagnosis, size of metastases subject to IRE, number of hepatic lesions, or time elapsed between IRE and diagnosis. CONCLUSION: For nonresectable CRLM, long-term survival data emphasize the value of IRE as a new minimally invasive local therapeutic approach in multimodal palliative treatment, which is currently limited to systemic or regional therapies in this setting.

20.
Clin Hemorheol Microcirc ; 66(4): 293-302, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28527200

RESUMEN

OBJECTIVE: To identify the indications for CEUS in renal imaging in an interdisciplinary ultrasound department. METHODS: 102 CEUS examinations of the kidney in 82 patients between September 2014 and July 2016 were analysed regarding the indication for ultrasound. CEUS was performed by one experienced sonographer agent after bolus injection of 1.0 up to 2.4 ml sulphur hexafluoride microbubbles using multifrequency probes with Contrast Harmonic imaging. RESULTS: CEUS of the kidney was performed in patients from 20 to 87 years. 44% of the patients had a stage 3 of chronic kidney disease and higher 38% of the patients had undergone a renal transplantation. No adverse events were observed. 54% of examinations were requested by nephrologists. The remaining by surgeons, oncologists or gastroenterologists. In 47% the objectives were the evaluation of complex renal cysts, in 31% the analysis of kidney perfusion, in 19% the assessment of solid renal masses. The remaining were perirenal tumours (2%) and infection (1%). CONCLUSIONS: CEUS is a good diagnostic alternative for patients with impaired renal function, complicated cysts, infections, solid renal lesions and after renal transplant.


Asunto(s)
Medios de Contraste/uso terapéutico , Riñón/diagnóstico por imagen , Perfusión/métodos , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Riñón/patología , Masculino , Persona de Mediana Edad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA