Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Anal Chem ; 95(19): 7665-7675, 2023 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-37071799

RESUMEN

Extracellular vesicles (EVs) carry RNA cargo that is believed to be associated with the cell-of-origin and thus have the potential to serve as a minimally invasive liquid biopsy marker for supplying molecular information to guide treatment decisions (i.e., precision medicine). We report the affinity isolation of EV subpopulations with monoclonal antibodies attached to the surface of a microfluidic chip that is made from a plastic to allow for high-scale production. The EV microfluidic affinity purification (EV-MAP) chip was used for the isolation of EVs sourced from two-orthogonal cell types and was demonstrated for its utility in a proof-of-concept application to provide molecular subtyping information for breast cancer patients. The orthogonal selection process better recapitulated the epithelial tumor microenvironment by isolating two subpopulations of EVs: EVEpCAM (epithelial cell adhesion molecule, epithelial origin) and EVFAPα (fibroblast activation protein α, mesenchymal origin). The EV-MAP provided recovery >80% with a specificity of 99 ± 1% based on exosomal mRNA (exo-mRNA) and real time-droplet digital polymerase chain reaction results. When selected from the plasma of healthy donors and breast cancer patients, EVs did not differ in size or total RNA mass for both markers. On average, 0.5 mL of plasma from breast cancer patients yielded ∼2.25 ng of total RNA for both EVEpCAM and EVFAPα, while in the case of cancer-free individuals, it yielded 0.8 and 1.25 ng of total RNA from EVEpCAM and EVFAPα, respectively. To assess the potential of these two EV subpopulations to provide molecular information for prognostication, we performed the PAM50 test (Prosigna) on exo-mRNA harvested from each EV subpopulation. Results suggested that EVEpCAM and EVFAPα exo-mRNA profiling using subsets of the PAM50 genes and a novel algorithm (i.e., exo-PAM50) generated 100% concordance with the tumor tissue.


Asunto(s)
Neoplasias de la Mama , Vesículas Extracelulares , Humanos , Femenino , Neoplasias de la Mama/genética , Neoplasias de la Mama/metabolismo , Molécula de Adhesión Celular Epitelial/metabolismo , ARN Mensajero/genética , ARN Mensajero/metabolismo , Vesículas Extracelulares/metabolismo , Biopsia Líquida , Microambiente Tumoral
2.
Anal Chem ; 95(26): 9892-9900, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37336762

RESUMEN

We present a chip-based extended nano-Coulter counter (XnCC) that can detect nanoparticles affinity-selected from biological samples with low concentration limit-of-detection that surpasses existing resistive pulse sensors by 2-3 orders of magnitude. The XnCC was engineered to contain 5 in-plane pores each with an effective diameter of 350 nm placed in parallel and can provide high detection efficiency for single particles translocating both hydrodynamically and electrokinetically through these pores. The XnCC was fabricated in cyclic olefin polymer (COP) via nanoinjection molding to allow for high-scale production. The concentration limit-of-detection of the XnCC was 5.5 × 103 particles/mL, which was a 1,100-fold improvement compared to a single in-plane pore device. The application examples of the XnCC included counting affinity selected SARS-CoV-2 viral particles from saliva samples using an aptamer and pillared microchip; the selection/XnCC assay could distinguish the COVID-19(+) saliva samples from those that were COVID-19(-). In the second example, ovarian cancer extracellular vesicles (EVs) were affinity selected using a pillared chip modified with a MUC16 monoclonal antibody. The affinity selection chip coupled with the XnCC was successful in discriminating between patients with high grade serous ovarian cancer and healthy donors using blood plasma as the input sample.


Asunto(s)
COVID-19 , Vesículas Extracelulares , Nanopartículas , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Virión
3.
Int J Mol Sci ; 22(15)2021 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-34360536

RESUMEN

The endothelium is the inner layer of all blood vessels and it regulates hemostasis. It also plays an active role in the regulation of the systemic inflammatory response. Systemic inflammatory disease often results in alterations in vascular endothelium barrier function, increased permeability, excessive leukocyte trafficking, and reactive oxygen species production, leading to organ damage. Therapeutics targeting endothelium inflammation are urgently needed, but strong concerns regarding the level of phenotypic heterogeneity of microvascular endothelial cells between different organs and species have been expressed. Microvascular endothelial cell heterogeneity in different organs and organ-specific variations in endothelial cell structure and function are regulated by intrinsic signals that are differentially expressed across organs and species; a result of this is that neutrophil recruitment to discrete organs may be regulated differently. In this review, we will discuss the morphological and functional variations in differently originated microvascular endothelia and discuss how these variances affect systemic function in response to inflammation. We will review emerging in vivo and in vitro models and techniques, including microphysiological devices, proteomics, and RNA sequencing used to study the cellular and molecular heterogeneity of endothelia from different organs. A better understanding of microvascular endothelial cell heterogeneity will provide a roadmap for developing novel therapeutics to target the endothelium.


Asunto(s)
Antiinflamatorios/farmacología , Endotelio Vascular/efectos de los fármacos , Inflamación/tratamiento farmacológico , Animales , Humanos
4.
Biochemistry ; 57(38): 5533-5543, 2018 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-30183257

RESUMEN

Mobilization of iron from bacterioferritin (BfrB) requires specific interactions with a [2Fe-2S] ferredoxin (Bfd). Blocking the BfrB:Bfd interaction results in irreversible iron accumulation in BfrB and iron deficiency in the cytosol [Eshelman, K., et al. (2017) Metallomics 9, 646-659]. The only known Bfd structure, which was obtained in complex with BfrB (Protein Data Bank entry 4E6K ), indicated a new fold and suggested that the stability of Bfd is aided by an anion binding site consisting of R26, R29, and K46. We investigated the Bfd fold using site-directed mutagenesis, X-ray crystallography, and biochemistry in solution. The X-ray structure, which is nearly identical to that of Bfd in the BfrB:Bfd complex, shows that the [2Fe-2S] cluster preorganizes residues at the BfrB:Bfd interface into a structure complementary to the Bfd binding site on BfrB. Studies in solution showed rapid loss of the [2Fe-2S] cluster at a low ionic strength but higher stability with an increasing ionic strength, thus supporting a structural anion binding site. Structures of the R26E and R26E/K46Y mutants are nearly identical to that of Bfd, except for a new network of hydrogen bonds stabilizing the region encompassing the former anion binding site. The stability of the R26E and R26E/K46Y mutants, which is weakly and completely independent of solution ionic strength, respectively, corroborates that Bfd requires an anion binding site. The mutations, which caused only small changes to the strength of the BfrB:Bfd interaction and mobilization of iron from BfrB, indicate that the anion binding site in Bfd serves primarily a structural role.


Asunto(s)
Aniones/metabolismo , Proteínas Bacterianas/metabolismo , Grupo Citocromo b/metabolismo , Ferritinas/metabolismo , Homeostasis , Proteínas Hierro-Azufre/metabolismo , Hierro/metabolismo , Pseudomonas aeruginosa/metabolismo , Proteínas Bacterianas/química , Proteínas Bacterianas/genética , Sitios de Unión , Catálisis , Cristalografía por Rayos X , Grupo Citocromo b/química , Grupo Citocromo b/genética , Ferredoxinas/metabolismo , Ferritinas/química , Ferritinas/genética , Proteínas Hierro-Azufre/química , Proteínas Hierro-Azufre/genética , Modelos Moleculares , Mutagénesis Sitio-Dirigida , Mutación , Conformación Proteica , Dominios Proteicos
5.
Electroanalysis ; 34(12): 1961-1975, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37539083

RESUMEN

We report an in-plane extended nanopore Coulter counter (XnCC) chip fabricated in a thermoplastic via imprinting. The fabrication of the sensor utilized both photolithography and focused ion beam milling to make the microfluidic network and the in-plane pore sensor, respectively, in Si from which UV resin stamps were generated followed by thermal imprinting to produce the final device in the appropriate plastic (cyclic olefin polymer, COP). As an example of the utility of this in-plane extended nanopore sensor, we enumerated SARS-CoV-2 viral particles (VPs) affinity-selected from saliva and extracellular vesicles (EVs) affinity-selected from plasma samples secured from mouse models exposed to different ionizing radiation doses.

6.
Sci Adv ; 8(39): eabn9665, 2022 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-36170362

RESUMEN

We report a microfluidic assay to select active severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viral particles (VPs), which were defined as intact particles with an accessible angiotensin-converting enzyme 2 receptor binding domain (RBD) on the spike (S) protein, from clinical samples. Affinity selection of SARS-CoV-2 particles was carried out using injection molded microfluidic chips, which allow for high-scale production to accommodate large-scale screening. The microfluidic contained a surface-bound aptamer directed against the virus's S protein RBD to affinity select SARS-CoV-2 VPs. Following selection (~94% recovery), the VPs were released from the chip's surface using a blue light light-emitting diode (89% efficiency). Selected SARS-CoV-2 VP enumeration was carried out using reverse transcription quantitative polymerase chain reaction. The VP selection assay successfully identified healthy donors (clinical specificity = 100%) and 19 of 20 patients with coronavirus disease 2019 (COVID-19) (95% sensitivity). In 15 patients with COVID-19, the presence of active SARS-CoV-2 VPs was found. The chip can be reprogrammed for any VP or exosomes by simply changing the affinity agent.

7.
Artículo en Inglés | MEDLINE | ID: mdl-34414401

RESUMEN

Extracellular vesicles (EVs) have been recognized as an evolving biomarker within the liquid biopsy family. While carrying both host cell proteins and different types of RNAs, EVs are also present in sufficient quantities in biological samples to be tested using many molecular analysis platforms to interrogate their content. However, because EVs in biological samples are comprised of both disease and non-disease related EVs, enrichment is often required to remove potential interferences from the downstream molecular assay. Most benchtop isolation/enrichment methods require > milliliter levels of sample and can cause varying degrees of damage to the EVs. In addition, some of the common EV benchtop isolation methods do not sort the diseased from the non-diseased related EVs. Simultaneously, the detection of the overall concentration and size distribution of the EVs is highly dependent on techniques such as electron microscopy and Nanoparticle Tracking Analysis, which can include unexpected variations and biases as well as complexity in the analysis. This review discusses the importance of EVs as a biomarker secured from a liquid biopsy and covers some of the traditional and non-traditional, including microfluidics and resistive pulse sensing, technologies for EV isolation and detection, respectively.

8.
Annu Rev Anal Chem (Palo Alto Calif) ; 14(1): 207-229, 2021 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-33974805

RESUMEN

Liquid biopsy markers, which can be secured from a simple blood draw or other biological samples, are used to manage a variety of diseases and even monitor for bacterial or viral infections. Although there are several different types of liquid biopsy markers, the subcellular ones, including cell-free DNA, microRNA, extracellular vesicles, and viral particles, are evolving in terms of their utility. A challenge with liquid biopsy markers is that they must be enriched from the biological sample prior to analysis because they are a vast minority in a mixed population, and potential interferences may be present in the sample matrix that can inhibit profiling the molecular cargo from the subcellular marker. In this article, we discuss existing and developing analytical enrichment platforms used to isolate subcellular liquid biopsy markers, and discuss their figures of merit such as recovery, throughput, and purity.


Asunto(s)
Biomarcadores de Tumor , Vesículas Extracelulares , Biopsia Líquida
9.
Radiother Oncol ; 158: 21-32, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33581220

RESUMEN

Radiation-induced endothelial/vascular injury is a major complicating factor in radiotherapy and a leading cause of morbidity and mortality in nuclear or radiological catastrophes. Exposure of tissue to ionizing radiation (IR) leads to the release of oxygen radicals and proteases that result in loss of endothelial barrier function and leukocyte dysfunction leading to tissue injury and organ damage. Microvascular endothelial cells are particularly sensitive to IR and radiation-induced alterations in endothelial cell function are thought to be a critical factor in organ damage through endothelial cell activation, enhanced leukocyte-endothelial cell interactions, increased barrier permeability and initiation of apoptotic pathways. These radiation-induced inflammatory responses are important in early and late radiation pathologies in various organs. A better understanding of mechanisms of radiation-induced endothelium dysfunction is therefore vital, as radiobiological response of endothelium is of major importance for medical management and therapeutic development for radiation injuries. In this review, we summarize the current knowledge of cellular and molecular mechanisms of radiation-induced endothelium damage and their impact on early and late radiation injury. Furthermore, we review established and emerging in vivo and in vitro models that have been developed to study the mechanisms of radiation-induced endothelium damage and to design, develop and rapidly screen therapeutics for treatment of radiation-induced vascular damage. Currently there are no specific therapeutics available to protect against radiation-induced loss of endothelial barrier function, leukocyte dysfunction and resulting organ damage. Developing therapeutics to prevent endothelium dysfunction and normal tissue damage during radiotherapy can serve as the urgently needed medical countermeasures.


Asunto(s)
Células Endoteliales , Traumatismos por Radiación , Endotelio , Endotelio Vascular , Humanos , Traumatismos por Radiación/etiología , Radiación Ionizante , Especies Reactivas de Oxígeno
10.
Expert Rev Mol Diagn ; 20(8): 771-788, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32500751

RESUMEN

INTRODUCTION: There is a short time window (4.5 h) for the effective treatment of acute ischemic stroke (AIS), which uses recombinant tissue plasminogen activator (rt-PA). Unfortunately, this short therapeutic timeframe is a contributing factor to the relatively small number of patients (~7%) that receive rt-PA. While neuroimaging is the major diagnostic for AIS, more timely decisions could be made using a molecular diagnostic. AREAS COVERED: In this review, we survey neuroimaging techniques used to diagnose stroke and their limitations. We also highlight the potential of various molecular/cellular biomarkers, especially peripheral blood-based (i.e. liquid biopsy) biomarkers, for diagnosing stroke to allow for precision decisions on managing stroke in a timely manner. Both protein and nucleic acid molecular biomarkers are reviewed. In particular, mRNA markers are discussed for AIS and hemorrhagic stroke diagnosis sourced from both cells and extracellular vesicles. EXPERT OPINION: While there are a plethora of molecular markers for stroke diagnosis that have been reported, they have yet to be FDA-cleared. Possible reasons include the inability for these markers to appear in sufficient quantities for highly sensitive clinical decisions within the rt-PA therapeutic time.


Asunto(s)
Biomarcadores , Biopsia Líquida/métodos , Accidente Cerebrovascular/diagnóstico , Células Sanguíneas/metabolismo , Barrera Hematoencefálica/metabolismo , Manejo de la Enfermedad , Susceptibilidad a Enfermedades , Perfilación de la Expresión Génica , Humanos , Imagen Multimodal/métodos , Pronóstico , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/terapia , Transcriptoma , Resultado del Tratamiento
11.
Chem Commun (Camb) ; 56(29): 4098-4101, 2020 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-32163053

RESUMEN

We detail a heterobifunctional, 7-aminocoumarin photocleavable (PC) linker with unique properties to covalently attach Abs to surfaces and subsequently release them with visible light (400-450 nm). The PC linker allowed rapid (2 min) and efficient (>90%) release of CTCs and EVs without damaging their molecular cargo.


Asunto(s)
Anticuerpos Monoclonales/química , Cumarinas/química , Vesículas Extracelulares , Células Neoplásicas Circulantes , Anticuerpos Monoclonales/efectos de la radiación , Línea Celular Tumoral , Supervivencia Celular , Cumarinas/efectos de la radiación , Humanos , Luz , Biopsia Líquida , Microfluídica
12.
Commun Biol ; 3(1): 613, 2020 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-33106557

RESUMEN

Currently there is no in vitro diagnostic test for acute ischemic stroke (AIS), yet rapid diagnosis is crucial for effective thrombolytic treatment. We previously demonstrated the utility of CD8(+) T-cells' mRNA expression for AIS detection; however extracellular vesicles (EVs) were not evaluated as a source of mRNA for AIS testing. We now report a microfluidic device for the rapid and efficient affinity-enrichment of CD8(+) EVs and subsequent EV's mRNA analysis using droplet digital PCR (ddPCR). The microfluidic device contains a dense array of micropillars modified with anti-CD8α monoclonal antibodies that enriched 158 ± 10 nm sized EVs at 4.3 ± 2.1 × 109 particles/100 µL of plasma. Analysis of mRNA from CD8(+) EVs and their parental T-cells revealed correlation in the expression for AIS-specific genes in both cell lines and healthy donors. In a blinded study, 80% test positivity for AIS patients and controls was revealed with a total analysis time of 3.7 h.


Asunto(s)
Vesículas Extracelulares/fisiología , Regulación de la Expresión Génica/fisiología , Accidente Cerebrovascular Isquémico/diagnóstico , Dispositivos Laboratorio en un Chip , ARN Mensajero/metabolismo , Biomarcadores , Isquemia Encefálica/metabolismo , Línea Celular , Humanos , ARN Mensajero/genética , Linfocitos T
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA