Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Acta Radiol ; 50(8): 854-9, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19634024

RESUMEN

BACKGROUND: Contrast-enhanced ultrasound (CEUS) has gained interest because of its ability to gather vascular information in various organs. There is still a matter of debate concerning its value in breast lesions. The method of choice on how to administer the contrast agent varies depending on the organ to be studied. Infusion of microbubbles is used in echocardiography, while bolus administration is the preferred technique for abdominal organs. PURPOSE: To compare-in equal doses-bolus versus continuous infusion of microbubbles, using real-time contrast harmonic imaging in breast tumors. MATERIAL AND METHODS: A total of 29 female patients (mean age 54 years) with either clear malignant or benign findings in the breast or axilla were included. Contrast harmonic imaging (CHI US) was performed with a Philips iU22 using an L9-3 MHz linear probe, especially designed for this purpose. A low mechanical index (0.06-0.07) was used to avoid massive destruction of the microbubbles. A dose of 2.4 ml of Sono Vue was first infused intravenously over 1 min with an infusion pump. After 10 min, the same dose was injected as a bolus over 2 s, followed by a flush of 10 ml of saline solution. Contrast uptakes by the tumors were recorded 2 min from the moment of injection, with both methods for each patient. RESULTS: Bolus administration of contrast agent provided a sharply demarcated enhancement and wash-out pattern for all lesions. The continuous infusion of the same contrast agent failed to show any wash-in/wash-out or time-to-peak/peak intensity phenomena in all cases. CONCLUSION: CEUS using real-time harmonic imaging in order to evaluate breast tumors should be performed with bolus administration of contrast agent in order to achieve better intensity/time curve outcomes.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Medios de Contraste/administración & dosificación , Fosfolípidos/administración & dosificación , Hexafluoruro de Azufre/administración & dosificación , Ultrasonografía Mamaria , Adulto , Anciano , Axila , Neoplasias de la Mama/patología , Femenino , Humanos , Infusiones Intravenosas , Inyecciones , Persona de Mediana Edad
2.
Eur J Radiol ; 39(2): 104-10, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11522419

RESUMEN

OBJECTIVES: To examine interval cancer detection rate for a system of computer assisted detection (CAD) and its influence on radiologists' sensitivity/specificity in a screen-like retrospective review situation. MATERIALS AND METHODS: Three screening radiologists reviewed previous screen images of 59 interval cancers mixed with other screening mammograms (ratio 1:5) and non-mixed. Mixed interval cases were interpreted both without and with aid of CAD. RESULTS: CAD detected a number of 14 interval cancers while the three radiologists detected 17, 12 and 11 without and 16, 10 and 13 with CAD. Although CAD specificity was low (38%) no reduction in radiologists' specificity occurred using CAD (73%, 82% and 89% without and 78%, 90% and 92% with CAD). Non-mixed reading increased radiologists' detection rate to 21, 17 and 19 interval cancers respectively. CONCLUSION: Despite sufficiently high sensitivity for CAD alone no increase in radiologist sensitivity (or decrease in specificity) occurred with CAD. Improving CAD specificity, with unaffectedly high sensitivity, should make radiologists more inclined to revise interpretations according to CAD. The potential sensitivity increase, noted when using CAD as a double reader, could be realised in this way.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico , Toma de Decisiones Asistida por Computador , Diagnóstico por Computador , Anciano , Femenino , Humanos , Persona de Mediana Edad , Radiografía , Radiología , Sensibilidad y Especificidad , Salud de la Mujer
3.
Nucl Med Commun ; 21(2): 159-63, 2000 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10758611

RESUMEN

In this study, we made an intra-individual comparison of the uptake of 99Tcm-MDP and 99Tcm-MIBI in breast cancer. Twenty women with large breast masses (one dimension > or = 3 cm on mammography) underwent SPET in the supine position with both agents. All transverse sections demonstrating tumour activity were added together and the net (total) tumour uptake in a region of interest was compared to that of surrounding tissue activity (background). We also evaluated maximum tumour uptake versus background activity. Tumour uptake was observed in all examinations. In contrast to MIBI, eight MDP examinations showed increased uptake in normal breast parenchyma in addition to tumour uptake. There was no significant difference in net tumour uptake between the two tracers and non-parenchymal (indifferent) background activity, but the maximum tumour activity of MIBI was significantly higher than that of MDP. In the eight MDP examinations with parenchymal activity, mammograms were required to identify tumour uptake correctly. In conclusion, MDP may provide similar images to MIBI in postmenopausal women not receiving hormone replacement therapy. For other patients, MIBI gives better tumour depiction.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Radiofármacos , Medronato de Tecnecio Tc 99m , Tecnecio Tc 99m Sestamibi , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Neoplasias de la Mama/patología , Femenino , Humanos , Persona de Mediana Edad , Radiografía , Radiofármacos/farmacocinética , Posición Supina , Medronato de Tecnecio Tc 99m/farmacocinética , Tecnecio Tc 99m Sestamibi/farmacocinética , Distribución Tisular
5.
Acta Radiol ; 46(8): 782-90, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16392602

RESUMEN

PURPOSE: To determine the diagnostic accuracy of targeted electrical impedance imaging in characterizing breast lesions, and to evaluate whether lesion size, depth and histopathology affect the diagnosis. MATERIAL AND METHODS: A total of 137 women with 145 lesions (79 malignant and 66 benign) found by palpation or mammography were prospectively enrolled in this study. The patients were examined by means of clinical breast examination, mammography, ultrasonography, and electrical impedance imaging with TransScan TS2000. A level of suspicion (LOS) post-processing algorithm (v2.67) was used for TS2000 lesion assessment. Imaging findings were correlated with cytologic (n=54) and histologic diagnoses (n=91). Patients with benign lesions were followed up for a mean of 36 months. RESULTS: TS2000 showed a high sensitivity (86%) which did not differ significantly from that of mammography (87%) and ultrasonography (US) (75%). The specificity of TS2000 (49%) was significantly lower compared to mammography (97%, P<0.0001) and US (100%, P<0.0001). The additive use of TS2000 to mammography and US yielded no significant increase in sensitivity (97%), but the decrease in specificity was significant (46%, P<0.0001). Diagnostic effectiveness of TS2000 (Az=0.68), as measured by the area under the ROC curve, was significantly lower than for mammography (Az=0.93, P<0.0001) and for US (Az=0.91, P<0.0001). When using TS2000 in addition to mammography and US (Az=0.86), a significant impairment was found (P=0.0003). CONCLUSION: The role of targeted electrical impedance imaging as an adjunct to mammography and ultrasonography in the diagnosis of breast lesions is not justified by the result of this study.


Asunto(s)
Algoritmos , Enfermedades de la Mama/diagnóstico , Diagnóstico por Imagen/métodos , Impedancia Eléctrica , Procesamiento de Imagen Asistido por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades de la Mama/patología , Enfermedades de la Mama/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Mamografía , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Ultrasonografía Mamaria
6.
Acta Radiol ; 44(3): 284-7, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12751999

RESUMEN

PURPOSE: Response assessment at neoadjuvant (preoperative) chemotherapy of locally advanced breast cancer using clinical examination and mammography is insensitive. Mammoscintigraphy with 99mTc-MIBI was studied for the prediction of response at such therapy before finishing the chemotherapy cycles. MATERIAL AND METHODS: Chemotherapy was given as repeated courses of 5-fluorouracil, epirubicin and cyclophosphamide (FEC). In 1 patient group (n = 23), the tumor uptake relative to surrounding breast tissue and lung tissue at SPECT examination after finishing neoadjuvant chemotherapy was compared with the examination made before chemotherapy. In another group (n = 30), a similar comparison after the first therapy cycle (mean 19 days) with a baseline examination was made. Histologic examination of the resected tumors was made. RESULTS: After finishing chemotherapy, there was a strong reduction of the relative tumor activity, while there was no correlation with therapy effect as assessed by histology. After one therapy course, there was no significant reduction of the relative tumor uptake. CONCLUSION: Scintigraphy with 99mTc-MIBI demonstrated the response after finished neoadjuvant chemotherapy of breast cancer using FEC-courses. It cannot be used to predict a therapy response after one therapy course.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Radiofármacos , Tecnecio Tc 99m Sestamibi , Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Estudios de Casos y Controles , Ciclofosfamida/administración & dosificación , Epirrubicina/administración & dosificación , Femenino , Fluorouracilo/administración & dosificación , Humanos , Persona de Mediana Edad , Terapia Neoadyuvante , Estereoisomerismo , Factores de Tiempo , Tomografía Computarizada de Emisión de Fotón Único
7.
Acta Radiol ; 44(3): 288-93, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12752000

RESUMEN

PURPOSE: The aim of this study was to determine the clinical value of scintimammography with 99m-Tc-MIBI (Sc) as a complementary method to the triple diagnostic procedure in the diagnosis of breast lesions. MATERIAL AND METHODS: Ninety-six consecutive patients with 65 palpable and 54 non-palpable breast lesions were included in a prospective study. All lesions were evaluated by clinical examination, mammography and fine-needle-aspiration cytology (FNAC), called triple diagnostic procedure (TD). Prone planar scintimammography with 99m-Tc-MIBI was performed in all patients. Five groups were defined for diagnosis: 1 = normal; 2 = benign; 3 = probably benign; 4 = highly suspect of malignancy; and 5 = malignant. In the calculations, groups 1-3 were considered benign, and 4-5 malignant. All lesions were excised and examined histologically. The additional value of Sc + TD procedure was studied separately for palpable and non-palpable lesions. RESULTS: Histologically, 83 malignant and 36 benign lesions were found in the 119 breast lesions. Sensitivity for malignancy in palpable lesions of TD alone and of the combination TD + Sc were 95.6% and 100%, respectively. Sensitivity for malignancy in non-palpable lesions of TD and TD + Sc was 89.1% and 97.2%, respectively. CONCLUSION: Adding scintimammography to the triple diagnostic procedure increased the sensitivity for the detection of both palpable and non-palpable breast cancers, but decreased the specificity.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Radiofármacos , Tecnecio Tc 99m Sestamibi , Biopsia con Aguja , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/patología , Femenino , Humanos , Persona de Mediana Edad , Palpación , Valor Predictivo de las Pruebas , Estudios Prospectivos , Cintigrafía , Sensibilidad y Especificidad
8.
Acta Radiol ; 37(5): 727-31, 1996 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-8915284

RESUMEN

PURPOSE: In order to evaluate the prognostic significance of chest film findings in connection with cytomegalovirus (CMV) and/or pneumocystis carinii infection (PC), a retrospective review was made of the pulmonary charts of 274 recipients of kidney and/or pancreatic grafts transplanted between April 1987 and December 1990. MATERIAL, METHODS AND RESULTS: Positive laboratory findings for CMV and/or PC were seen in 92 patients. In 77 patients only CMV was found, 13 patients had both CMV and PC, and 2 patients had only PC. In 57 patients a chest examination was performed. The films were reviewed by 2 radiologists independently. In 32 patients normal chest film findings were seen, while 25 patients demonstrated pathological changes. Of the patients with pathological changes 3 had only pleuritis while the remaining 22 demonstrated parenchymal infiltrations. No deaths occurred among patients infected with CMV and/or PC, when the chest film findings were normal or pleuritis only was seen, but there were 9 deaths in the group of patients with parenchymal infiltrations. Of the patients who died, 2 had only CMV, 5 had both CMV and PC, and 2 had only PC. The overall mortality, regardless of radiological findings, did not exceed 3% in patients with CMV only, but increased to 38% in patients with both CMV and PC. In patients with parenchymal infiltrations the corresponding mortality figures were increased to 18% and 56%, respectively. CONCLUSION: We conclude that a radiologically verified pneumonia related to the infectious agent influences the prognosis, and that CMV pneumonia has a better prognosis than PC pneumonia.


Asunto(s)
Infecciones por Citomegalovirus/diagnóstico por imagen , Trasplante de Riñón/diagnóstico por imagen , Trasplante de Páncreas/diagnóstico por imagen , Neumonía por Pneumocystis/diagnóstico por imagen , Neumonía Viral/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Infecciones por Citomegalovirus/mortalidad , Humanos , Terapia de Inmunosupresión/efectos adversos , Neumonía por Pneumocystis/mortalidad , Neumonía Viral/mortalidad , Complicaciones Posoperatorias/microbiología , Complicaciones Posoperatorias/mortalidad , Pronóstico , Radiografía , Estudios Retrospectivos
9.
Eur J Nucl Med ; 9(11): 499-501, 1984.
Artículo en Inglés | MEDLINE | ID: mdl-6240400

RESUMEN

99mTc-Plasmin scintigraphy of suspected vein thrombosis registered by a gamma camera was compared with phlebography. The results indicate that the plasmin test can be an alternative method to phlebography. The plasmin test registered by a gamma camera has a high sensitivity but relatively low specificity; this agrees with the results of previous investigations regarding registration with a single detector.


Asunto(s)
Fibrinolisina , Tecnecio , Tromboflebitis/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flebografía , Cintigrafía
10.
Am J Obstet Gynecol ; 181(2): 348-52, 1999 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-10454681

RESUMEN

OBJECTIVE: Our purpose was to investigate the effects of various hormone replacement regimens on mammographic breast density. STUDY DESIGN: Mammographic density was recorded in women participating in a population-based screening program. All women were nonusers of hormone replacement therapy at first mammogram and thereafter reported continuous use of the same treatment: estrogen alone (n = 50) or estrogen in cyclic (n = 75) or continuous (n = 50) combination with progestogen. Mammographic density was quantified according to the Wolfe classification. RESULTS: An increase in mammographic density was much more common among women receiving continuous combination hormone replacement therapy (52%) than among those receiving cyclic (13%) and estrogen-only (18%) treatment. The increase in density was apparent already at first visit after the start of hormone replacement therapy. There was little change in mammographic status during long-term follow-up. CONCLUSION: Regimens of hormone replacement therapy were shown to have different effects on the normal breast. There is an urgent need to clarify the biologic nature and significance of a change in mammographic density during treatment and, in particular, its relation to symptoms and breast cancer risk.


Asunto(s)
Mama/anatomía & histología , Terapia de Reemplazo de Estrógeno/efectos adversos , Mamografía , Adulto , Anciano , Estrógenos/administración & dosificación , Femenino , Humanos , Persona de Mediana Edad , Progestinas/administración & dosificación
11.
Climacteric ; 4(1): 42-8, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11379377

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the impact of different hormone replacement therapy (HRT) regimens on mammographic breast density. STUDY DESIGN: Mammographic density was recorded in women participating in a population-based screening program. At first mammogram, all women were non-users of HRT, and thereafter reported continuous use of the same HRT regimen. The study population comprised 158 women: a total of 52 women were using continuous combined HRT (conjugated equine estrogen 0.625 mg plus medroxyprogesterone acetate 5 mg); 51 women were using low-dose oral estrogen alone (estriol 2 mg daily); and 55 women were using unopposed transdermal estrogen given as a patch (estradiol 50 micrograms/24 h). Films were coded and analyzed for mammographic density by an independent radiologist blinded to treatments. Mammographic density was classified according to Wolfe. RESULTS: An increase in mammographic density was much more common among women taking continuous combined HRT (40%) than for those using oral low-dose estrogen (6%) and transdermal (2%) treatment. The increase in density was already apparent at the first visit after starting HRT. During long-term follow-up, there was very little change in mammographic status. CONCLUSION: HRT regimens were shown to have different effects on the normal breast. There is an urgent need to clarify the biological nature and significance of a change in mammographic density during treatment and, in particular, its relation to symptoms and breast cancer risk.


Asunto(s)
Estriol/administración & dosificación , Estriol/efectos adversos , Terapia de Reemplazo de Estrógeno/efectos adversos , Terapia de Reemplazo de Estrógeno/métodos , Estrógenos Conjugados (USP)/administración & dosificación , Estrógenos Conjugados (USP)/efectos adversos , Enfermedad Fibroquística de la Mama/inducido químicamente , Enfermedad Fibroquística de la Mama/diagnóstico por imagen , Mamografía , Acetato de Medroxiprogesterona/administración & dosificación , Acetato de Medroxiprogesterona/efectos adversos , Congéneres de la Progesterona/administración & dosificación , Congéneres de la Progesterona/efectos adversos , Administración Cutánea , Administración Oral , Adulto , Análisis de Varianza , Quimioterapia Combinada , Femenino , Enfermedad Fibroquística de la Mama/clasificación , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Método Simple Ciego
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA