Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 24(5): e13916, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36763085

RESUMEN

PURPOSE: Adaptive radiation therapy (ART) on the integrated Elekta Unity magnetic resonance (MR)-linac requires routine quality assurance to verify delivery accuracy and system data transfer. In this work, our objective was to develop and validate a novel automated end-to-end test suite that verifies data transfer between multiple software platforms and quantifies the performance of multiple machine subcomponents critical to the ART process. METHODS: We designed and implemented a software tool to quantify the MR and megavoltage (MV) isocenter coincidence, treatment couch positioning consistency, isocenter shift accuracy for the adapted plan as well as the MLC and jaw position accuracy following the beam aperture adaptation. Our tool employs a reference treatment plan with a simulated isocenter shift generated on an MR image of a readily available phantom with MR and MV visible fiducials. Execution of the test occurs within the standard adapt-to-position (ATP) clinical workflow with MV images collected of the delivered treatment fields. Using descriptive statistics, we quantified uncertainty in couch positioning, isocentre shift as well as the jaw and MLC positions of the adapted fields. We also executed sensitivity measurements to evaluate the detection algorithm's performance. RESULTS: We report the results of 301 daily testing instances. We demonstrated consistent tracking of the MR-to-MV alignment with respect to the established value and to detect small changes on the order of 0.2 mm following machine service events. We found couch position consistency relative to the test baseline value was within 95% CI [-0.31, 0.26 mm]. For phantom shifts that form the basis for the plan adaptation, we found agreement between MV-image-detected phantom shift and online image registration, within ± 1.5 mm in all directions with a 95% CI difference of [-1.29, 0.79 mm]. For beam aperture adaptation accuracy, we found differences between the planned and detected jaw positions had a mean value of 0.27 mm and 95% CI of [-0.29, 0.82 mm] and -0.17 mm and 95% CI of [-0.37, 0.05 mm] for the MLC positions. Automated fiducial detected accuracy was within 0.08 ± 0.20 mm of manual localization. Introduced jaw and MLC position errors (1-10 mm) were detected within 0.55 mm (within 1 mm for 15/256 instances for the jaws). Phantom shifts (1.3 or 5 mm in each cardinal direction) from a reference position were detected within 0.26 mm. CONCLUSIONS: We have demonstrated the accuracy and sensitivity of a daily end-to-end test suite capable of detecting errors in multiple machine subcomponents including system data transfer. Our test suite evaluates the entire treatment workflow and has captured system communication issues prior to patient treatment. With automated processing and the use of a standard vendor-provided phantom, it is possible to expand to other Unity sites.


Asunto(s)
Imagen por Resonancia Magnética , Aceleradores de Partículas , Humanos , Imagen por Resonancia Magnética/métodos , Programas Informáticos , Control de Calidad , Fantasmas de Imagen , Espectroscopía de Resonancia Magnética , Planificación de la Radioterapia Asistida por Computador/métodos
2.
J Appl Clin Med Phys ; 24(11): e14160, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37793084

RESUMEN

The purpose of this guideline is to provide a list of critical performance tests to assist the Qualified Medical Physicist (QMP) in establishing and maintaining a safe and effective quality assurance (QA) program. The performance tests on a linear accelerator (linac) should be selected to fit the clinical patterns of use of the accelerator and care should be given to perform tests which are relevant to detecting errors related to the specific use of the accelerator. Current recommendations for linac QA were reviewed to determine any changes required to those tests highlighted by the original report as well as considering new components of the treatment process that have become common since its publication. Recommendations are made on the acquisition of reference data, routine establishment of machine isocenter, basing performance tests on clinical use of the linac, working with vendors to establish QA tests and performing tests after maintenance and upgrades. The recommended tests proposed in this guideline were chosen based on consensus of the guideline's committee after assessing necessary changes from the previous report. The tests are grouped together by class of test (e.g., dosimetry, mechanical, etc.) and clinical parameter tested. Implementation notes are included for each test so that the QMP can understand the overall goal of each test. This guideline will assist the QMP in developing a comprehensive QA program for linacs in the external beam radiation therapy setting. The committee sought to prioritize tests by their implication on quality and patient safety. The QMP is ultimately responsible for implementing appropriate tests. In the spirit of the report from American Association of Physicists in Medicine Task Group 100, individual institutions are encouraged to analyze the risks involved in their own clinical practice and determine which performance tests are relevant in their own radiotherapy clinics.


Asunto(s)
Radiometría , Planificación de la Radioterapia Asistida por Computador , Humanos , Aceleradores de Partículas , Cintigrafía , Física
3.
Br J Radiol ; 97(1153): 31-40, 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38263844

RESUMEN

Recent innovations in image guidance, treatment delivery, and adaptive radiotherapy (RT) have created a new paradigm for planning target volume (PTV) margin design for patients with prostate cancer. We performed a review of the recent literature on PTV margin selection and design for intact prostate RT, excluding post-operative RT, brachytherapy, and proton therapy. Our review describes the increased focus on prostate and seminal vesicles as heterogenous deforming structures with further emergence of intra-prostatic GTV boost and concurrent pelvic lymph node treatment. To capture recent innovations, we highlight the evolution in cone beam CT guidance, and increasing use of MRI for improved target delineation and image registration and supporting online adaptive RT. Moreover, we summarize new and evolving image-guidance treatment platforms as well as recent reports of novel immobilization strategies and motion tracking. Our report also captures recent implementations of artificial intelligence to support image guidance and adaptive RT. To characterize the clinical impact of PTV margin changes via model-based risk estimates and clinical trials, we highlight recent high impact reports. Our report focusses on topics in the context of PTV margins but also showcase studies attempting to move beyond the PTV margin recipes with robust optimization and probabilistic planning approaches. Although guidelines exist for target margins conventional using CT-based image guidance, further validation is required to understand the optimal margins for online adaptation either alone or combined with real-time motion compensation to minimize systematic and random uncertainties in the treatment of patients with prostate cancer.


Asunto(s)
Braquiterapia , Neoplasias de la Próstata , Masculino , Humanos , Inteligencia Artificial , Tomografía Computarizada de Haz Cónico , Ganglios Linfáticos
4.
Radiother Oncol ; 193: 110120, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38311029

RESUMEN

PURPOSE: Children who require radiation therapy (RT) should ideally be treated awake, without anaesthesia, if possible. Audiovisual distraction is a known method to facilitate awake treatment, but its effectiveness at keeping children from moving during treatment is not known. The aim of this study was to evaluate intrafraction movement of children receiving RT while awake. METHODS: In this prospective study, we measured the intrafraction movement of children undergoing treatment with fractionated RT, using pre- and post-RT cone beam CT (CBCT) with image matching on bony anatomy. Study CBCTs were acquired at first fraction, weekly during RT, and at last fraction. The primary endpoint was the magnitude of vector change between the pre- and post-RT scans. Our hypothesis was that 90 % of CBCT acquisitions would have minimal movement, defined as <3 mm for head-and-neck (HN) treatments and <5 mm for non-HN treatments. RESULTS: A total of 65 children were enrolled and had evaluable data across 302 treatments with CBCT acquisitions. Median age was 11 years (range, 2-18; 1st and 3rd quartiles 7 and 14 years, respectively). Minimal movement was observed in 99.4 % of HN treatments and 97.2 % of non-HN treatments. The study hypothesis of >90 % of evaluations having minimal movement was met. Children who were age >11 years moved less at initial evaluation but tended to move more as a course of radiation progressed, as compared to children who were younger. CONCLUSION: Children receiving RT with audiovisual distraction while awake had small magnitudes of observed intrafraction movement, with minimal movement in >97 % of observed RT fractions. This study validates methods of anaesthesia avoidance using audiovisual distraction for selected children.


Asunto(s)
Anestesia , Radioterapia Guiada por Imagen , Humanos , Niño , Estudios Prospectivos , Movimiento , Tomografía Computarizada de Haz Cónico/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos
5.
Phys Imaging Radiat Oncol ; 30: 100588, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38883145

RESUMEN

Background and Purpose: Application of different deformable dose accumulation (DDA) solutions makes institutional comparisons after online-adaptive magnetic resonance-guided radiotherapy (OA-MRgRT) challenging. The aim of this multi-institutional study was to analyze accuracy and agreement of DDA-implementations in OA-MRgRT. Material and Methods: One gold standard (GS) case deformed with a biomechanical-model and five clinical cases consisting of prostate (2x), cervix, liver, and lymph node cancer, treated with OA-MRgRT, were analyzed. Six centers conducted DDA using institutional implementations. Deformable image registration (DIR) and DDA results were compared using the contour metrics Dice Similarity Coefficient (DSC), surface-DSC, Hausdorff-distance (HD95%), and accumulated dose-volume histograms (DVHs) analyzed via intraclass correlation coefficient (ICC) and clinical dosimetric criteria (CDC). Results: For the GS, median DDA errors ranged from 0.0 to 2.8 Gy across contours and implementations. DIR of clinical cases resulted in DSC > 0.8 for up to 81.3% of contours and a variability of surface-DSC values depending on the implementation. Maximum HD95%=73.3 mm was found for duodenum in the liver case. Although DVH ICC > 0.90 was found after DDA for all but two contours, relevant absolute CDC differences were observed in clinical cases: Prostate I/II showed maximum differences in bladder V28Gy (10.2/7.6%), while for cervix, liver, and lymph node the highest differences were found for rectum D2cm3 (2.8 Gy), duodenum Dmax (7.1 Gy), and rectum D0.5cm3 (4.6 Gy). Conclusion: Overall, high agreement was found between the different DIR and DDA implementations. Case- and algorithm-dependent differences were observed, leading to potentially clinically relevant results. Larger studies are needed to define future DDA-guidelines.

6.
Phys Imaging Radiat Oncol ; 30: 100570, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38544680

RESUMEN

Background and Purpose: Integrated magnetic resonance linear accelerator (MR-Linac) systems offer potential for biologically based adaptive radiation therapy using apparent diffusion coefficient (ADC). Accurate tracking of longitudinal ADC changes is key to establishing ADC-driven dose adaptation. Here, we report repeatability and reproducibility of intraprostatic ADC using deformable image registration (DIR) to correct for inter-fraction prostate changes. Materials and Methods: The study included within-fraction repeat ADC measurements for three consecutive fractions for 20 patients with prostate cancer treated on a 1.5 T MR-Linac. We deformably registered successive fraction T2-weighted images and applied the deformation vector field to corresponding ADC maps to align to fraction 2. We delineated gross tumour volume (GTV), peripheral zone (PZ) and prostate clinical target volume (CTV) regions-of-interest (ROIs) on T2-weighted MRI and copied to ADC maps. We computed intraclass correlation coefficients (ICC) and percent repeatability coefficient (%RC) to determine within-fraction repeatability and between-fraction reproducibility for individual voxels, mean and 10th percentile ADC values per ROI. Results: The ICC between repeats and fractions was excellent for mean and 10th percentile ADC in all ROIs (ICC > 0.86), and moderate repeatability and reproducibility existed for individual voxels (ICC > 0.542). Similarly, low %RC within-fraction (4.2-17.9 %) mean and 10th percentile ADC existed, with greater %RC between fractions (10.2-36.8 %). Higher %RC existed for individual voxel within-fraction (21.7-30.6 %) and between-fraction (32.1-34.5 %) ADC. Conclusions: Results suggest excellent ADC repeatability and reproducibility in clinically relevant ROIs using DIR to correct between-fraction anatomical changes. We established the precision of voxel-level ADC tracking for future biologically based adaptation implementation.

7.
Artículo en Inglés | MEDLINE | ID: mdl-38445180

RESUMEN

Purpose: An integrated magnetic resonance scanner and linear accelerator (MR-linac) was implemented with daily online adaptive radiation therapy (ART). This study evaluated patient-reported experiences with their overall hospital care as well as treatment in the MR-linac environment. Methods: Patients pre-screened for MR eligibility and claustrophobia were referred to simulation on a 1.5 T MR-linac. Patient-reported experience measures were captured using two validated surveys. The 15-item MR-anxiety questionnaire (MR-AQ) was administered immediately after the first treatment to rate MR-related anxiety and relaxation. The 40-item satisfaction with cancer care questionnaire rating doctors, radiation therapists, the services and care organization and their outpatient experience was administered immediately after the last treatment using five-point Likert responses. Results were analyzed using descriptive statistics. Results: 205 patients were included in this analysis. Multiple sites were treated across the pelvis and abdomen with a median treatment time per fraction of 46 and 66 min respectively. Patients rated MR-related anxiety as "not at all" (87%), "somewhat" (11%), "moderately" (1%) and "very much so" (1%). Positive satisfaction responses ranged from 78 to 100% (median 93%) across all items. All radiation therapist-specific items were rated positively as 96-100%. The five lowest rated items (range 78-85%) were related to general provision of information, coordination, and communication. Overall hospital care was rated positively at 99%. Conclusion: In this large, single-institution prospective cohort, all patients had low MR-related anxiety and completed treatment as planned despite lengthy ART treatments with the MR-linac. Patients overall were highly satisfied with their cancer care involving ART using an MR-linac.

8.
J Clin Monit Comput ; 27(2): 147-55, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23100168

RESUMEN

The PCO2 in arterial blood (PaCO2) is a good parameter for monitoring ventilation and acid-base changes in ventilated patients, but its measurement is invasive and difficult to obtain in small children. Attempts have been made to use the partial pressure of CO2 in end-tidal gas (PETCO2), as a noninvasive surrogate for PaCO2. Studies have revealed that, unfortunately, the differences between PETCO2 and PaCO2 are too variable to be clinically useful. We hypothesized that end-inspiratory rebreathing, previously shown to equalize PETCO2 and PaCO2 in spontaneously breathing humans, would also be effective with positive pressure ventilation. Eight newborn Yorkshire pigs were mechanically ventilated via a partial rebreathing circuit to implement end-inspiratory rebreathing. Arterial blood was sampled and tested for PaCO2. A variety of alveolar ventilations resulting in different combinations of end-tidal PCO2 (30-50 mmHg) and PO2 (35-500 mmHg) were tested for differences between PETCO2 and PaCO2 (PET-aCO2). The PET-aCO2 of all samples was (mean ± 1.96 SD) 0.4 ± 2.7 mmHg. Our study demonstrates that, in ventilated juvenile animals, end-inspiratory rebreathing maintains PET-aCO2 to what would be a clinically useful range. If verified clinically, this approach could open the way for non-invasive monitoring of arterial PCO2 in critically ill patients.


Asunto(s)
Análisis de los Gases de la Sangre/métodos , Dióxido de Carbono/química , Respiración Artificial/métodos , Respiración , Procesamiento de Señales Asistido por Computador , Anestesia/métodos , Animales , Animales Recién Nacidos , Presión Arterial , Arterias/fisiología , Análisis de los Gases de la Sangre/instrumentación , Dióxido de Carbono/sangre , Modelos Animales , Monitoreo Intraoperatorio/métodos , Presión Parcial , Pediatría/métodos , Presión , Porcinos
9.
Artículo en Inglés | MEDLINE | ID: mdl-37265510

RESUMEN

Purpose: To develop a practice-based training strategy to transition from radiation oncologist to therapist-driven prostate MR-Linac adaptive radiotherapy. Methods and materials: In phase 1, 7 therapists independently contoured the prostate and organs-at-risk on T2-weighted MR images from 11 previously treated MR-Linac prostate patients. Contours were evaluated quantitatively (i.e. Dice similarity coefficient [DSC] calculated against oncologist generated online contours) and qualitatively (i.e. oncologist using a 5-point Likert scale; a score ≥ 4 was deemed a pass, a 90% pass rate was required to proceed to the next phase). Phase 2 consisted of supervised online workflow with therapists required no intervention from the oncologist on 10 total cases to advance. Phase 3 involved unsupervised therapist-driven workflow, with offline support from oncologists prior to the next fraction. Results: In phase 1, the mean DSC was 0.92 (range 0.85-0.97), and mean Likert score was 3.7 for the prostate. Five therapists did not attain a pass rate (3-5 cases with prostate contour score < 4), underwent follow-up one-on-one review, and performed contours on a further training set (n = 5). Each participant completed a median of 12 (range 10-13) cases in phase 2; of 82 cases, minor direction were required from the oncologist on 5 regarding target contouring. Radiation oncologists reviewed 179 treatment fractions in phase 3, and deemed 5 cases acceptable but with suggestions for next fraction; all other cases were accepted without suggestions. Conclusion: A training stepwise program was developed and successfully implemented to enable a therapist-driven workflow for online prostate MR-Linac adaptive radiotherapy.

10.
Med Dosim ; 2023 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-37985297

RESUMEN

Postoperative prostate radiotherapy requires large planning target volume (PTV) margins to account for motion and deformation of the prostate bed. Adaptive radiation therapy (ART) can incorporate image-guidance data to personalize PTVs that maintain coverage while reducing toxicity. We present feasibility and dosimetry results of a prospective study of postprostatectomy ART. Twenty-one patients were treated with single-adaptation ART. Conventional treatments were delivered for fractions 1 to 6 and adapted plans for the remaining 27 fractions. Clinical target volumes (CTVs) and small bowel delineated on fraction 1 to 4 CBCT were used to generate adapted PTVs and planning organ-at-risk (OAR) volumes for adapted plans. PTV volume and OAR dose were compared between ART and conventional using Wilcoxon signed-rank tests. Weekly CBCT were used to assess the fraction of CTV covered by PTV, CTV D99, and small bowel D1cc. Clinical metrics were compared using a Student's t-test (p < 0.05 significant). Offline adaptive planning required 1.9 ± 0.4 days (mean ± SD). ART decreased mean adapted PTV volume 61 ± 37 cc and bladder wall D50 compared with conventional treatment (p < 0.01). The CTV was fully covered for 96% (97%) of fractions with ART (conventional). Reconstructing dose on weekly CBCT, a nonsignificant reduction in CTV D99 was observed with ART (94%) compared to conventional (96%). Reduced CTV D99 with ART was significantly correlated with large anterior-posterior rectal diameter on simulation CT. ART reduced the number of fractions exceeding our institution's small bowel D1c limit from 14% to 7%. This study has demonstrated the feasibility of offline ART for post-prostatectomy cancer. ART facilitates PTV volume reduction while maintaining reasonable CTV coverage and can reduce the dose to adjacent normal tissues.

11.
Phys Med Biol ; 67(12)2022 06 10.
Artículo en Inglés | MEDLINE | ID: mdl-35609587

RESUMEN

Objective.Machine learning (ML) based radiation treatment planning addresses the iterative and time-consuming nature of conventional inverse planning. Given the rising importance of magnetic resonance (MR) only treatment planning workflows, we sought to determine if an ML based treatment planning model, trained on computed tomography (CT) imaging, could be applied to MR through domain adaptation.Methods.In this study, MR and CT imaging was collected from 55 prostate cancer patients treated on an MR linear accelerator. ML based plans were generated for each patient on both CT and MR imaging using a commercially available model in RayStation 8B. The dose distributions and acceptance rates of MR and CT based plans were compared using institutional dose-volume evaluation criteria. The dosimetric differences between MR and CT plans were further decomposed into setup, cohort, and imaging domain components.Results.MR plans were highly acceptable, meeting 93.1% of all evaluation criteria compared to 96.3% of CT plans, with dose equivalence for all evaluation criteria except for the bladder wall, penile bulb, small and large bowel, and one rectum wall criteria (p< 0.05). Changing the input imaging modality (domain component) only accounted for about half of the dosimetric differences observed between MR and CT plans. Anatomical differences between the ML training set and the MR linac cohort (cohort component) were also a significant contributor.Significance.We were able to create highly acceptable MR based treatment plans using a CT-trained ML model for treatment planning, although clinically significant dose deviations from the CT based plans were observed. Future work should focus on combining this framework with atlas selection metrics to create an interpretable quality assurance QA framework for ML based treatment planning.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Masculino , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X/métodos
12.
Front Oncol ; 12: 877452, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35494044

RESUMEN

Background: A magnetic resonance linear accelerator (MR-Linac) provides superior soft tissue contrast to evaluate inter- and intra-fraction motion and facilitate online adaptive radiation therapy (ART). We present here an unusual case of locally advanced castrate-resistant prostate cancer treated with high-dose palliative ultra-hypofractionated radiation therapy on the MR-Linac with significant inter-fraction tumor regression. Case Presentation: The patient was a 65-year-old man diagnosed with metastatic prostate cancer to bone and pelvic lymph nodes 7 years prior. At diagnosis, he presented with a PSA of 23 ng/ml and was commenced on a luteinizing hormone-releasing hormone agonist, achieving a PSA nadir of 4.68 ng/ml at 12 months. The patient subsequently had progressive lower urinary tract symptoms, his PSA increased to 47 ng/ml, and there was a markedly enlarged pelvic mass involving the prostate with gross extra-capsular disease and invasion into the posterior bladder wall. The patient was referred for palliative radiation to the pelvic mass due to urinary symptoms, pain, and lower limb paraesthesia. Treatment was planned to be delivered on the MR-Linac with a schedule of 36 Gy over 6 weekly factions allowing for maximal target dose delivery while minimizing surrounding organs at risk (OARs) radiation exposure. Unexpectedly, the target volume had a marked 49% (453 cc to 233 cc) reduction that was accounted for in the online adaptive process. A new reference plan was generated after 3 fractions to add sacral plexus as an OAR, previously not visible due to mass encroachment. The patient reported ongoing reduction in urinary symptoms, pelvic pain, and lower limb paresthesia by the end of treatment. Conclusion: Using daily MR-guided ART, improved visualization of the changing target and OARs ensured safe dose escalation. The unexpected positive response of the target and improved patient outcomes demonstrated the added value of the MR-Linac for online adaptive radiotherapy in this setting.

13.
Artículo en Inglés | MEDLINE | ID: mdl-36105770

RESUMEN

Purpose: The purpose of this study is to evaluate the impact of intrafraction pelvic motion by comparing the adapted plan dose (APD) and the computed delivered dose of the day (DDOTD) for patients with prostate cancer (PCa) treated with SBRT on the MR-Linac. Methods: Twenty patients with PCa treated with MR-guided adaptive SBRT were included. A 9-field IMRT distribution was adapted based on the anatomy of the day to deliver a total prescription dose of 3000 cGy in 5 fractions to the prostate plus a 5 mm isotropic margin. Prostate, bladder, and rectum were re-contoured on the MR-image acquired during treatment delivery (MRBO). DDOTD was computed by propagating the dose from the daily adapted plan generated during treatment onto the MRBO. Results: Target coverage was met for all fractions, however, computed DDOTD was significantly less than the APD (p < 0.05). During an average treatment of 53 min, mean bladder volume increased by 116%, which led to a significant decrease in the DDOTD bladder D40% (p < 0.001). However, DDOTD to bladder 5 cc was significantly higher (p < 0.001) than APD. Rectum intrafraction changes were observed based on a volume change of -20% to 83% and presence of significant dose changes from APD to DDOTD for rectum D20% (p < 0.05) and D1cc (p < 0.0001). Conclusions: Intrafraction motion observed during prostate SBRT treatment on the MR-Linac have dosimetric impacts on both the target and organs at risk. Post-treatment computation using DDOTD may inform adaptation beyond anatomic changes in subsequent treatment fractions to best capitalize on MR-Linac technology and widen the therapeutic index of SBRT for PCa.

14.
Artículo en Inglés | MEDLINE | ID: mdl-35252598

RESUMEN

INTRODUCTION: To compare the dosimetry of prostate stereotactic radiotherapy (SBRT) delivered by adaptive intensity modulated radiotherapy (A-IMRT) and 3 degree of freedom volumetric modulated arc therapy (3DOF-VMAT). METHODS & MATERIALS: Twenty-five prostate patients treated with High Dose Rate (HDR) brachytherapy followed by SBRT were included (fifteen with hydrogel spacer in place for treatment). Interfraction changes in the volume of prostate, rectum and bladder were measured. Fractional dose to these structures was estimated for A-IMRT and 3DOF-VMAT for comparison against the corresponding reference dose and between each other. RESULTS: Clinically acceptable dose was delivered to prostate in all 125 fractions through A-IMRT and 3DOF-VMAT. A-IMRT was better than 3DOF-VMAT in reducing dose to 1 cm3 of rectum. Conversely, 3DOF-VMAT was superior in sparing 50% and 20% of rectum. When comparing the reference and delivered dose, there was no significant difference for Bladder D5cm3 for either technique. However, rectum in the high dose region benefited more from A-IMRT by being irradiated to a lower than reference dose in more fractions than 3DOF-VMAT. Hydrogel spacer reduced the rectal dose and was associated with a smaller deviation from reference dose for rectum D50% for A-IMRT. CONCLUSIONS: Despite the presence of large interfraction organ volumes changes, clinically acceptable dose was delivered to the prostate by both systems. A-IMRT facilitated a greater rectal sparing from the high dose region than 3DOF-VMAT. Further reduction in rectal dose could be achieved by hydrogel spacer to displace the rectum, or by adaptation delivered by VMAT.

15.
J Magn Reson Imaging ; 34(3): 608-15, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21761490

RESUMEN

PURPOSE: To provide the first comparison of absolute renal perfusion obtained by arterial spin labeling (ASL) and separable compartment modeling of dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). Moreover, we provide the first application of the dual bolus approach to quantitative DCE-MRI perfusion measurements in the kidney. MATERIALS AND METHODS: Consecutive ASL and DCE-MRI acquisitions were performed on six rabbits on a 1.5 T MRI system. Gadolinium (Gd)-DTPA was administered in two separate injections to decouple measurement of the arterial input function and tissue uptake curves. For DCE perfusion, pixel-wise and mean cortex region-of-interest tissue curves were fit to a separable compartment model. RESULTS: Absolute renal cortex perfusion estimates obtained by DCE and ASL were in close agreement: 3.28 ± 0.59 mL/g/min (ASL), 2.98 ± 0.60 mL/g/min (DCE), and 3.57 ± 0.96 mL/g/min (pixel-wise DCE). Renal medulla perfusion was 1.53 ± 0.35 mL/g/min (ASL) but was not adequately described by the separable compartment model. CONCLUSION: ASL and DCE-MRI provided similar measures of absolute perfusion in the renal cortex, offering both noncontrast and contrast-based alternatives to improve current renal MRI assessment of kidney function.


Asunto(s)
Algoritmos , Gadolinio DTPA , Interpretación de Imagen Asistida por Computador/métodos , Riñón/fisiología , Angiografía por Resonancia Magnética/métodos , Arteria Renal/fisiología , Circulación Renal/fisiología , Animales , Velocidad del Flujo Sanguíneo/fisiología , Medios de Contraste , Aumento de la Imagen/métodos , Conejos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Marcadores de Spin
16.
Pediatr Res ; 69(5 Pt 1): 418-24, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21258264

RESUMEN

The swine brain is emerging as a potentially valuable translational animal model of neurodevelopment and offers the ability to assess the impact of experimentally induced neurological disorders. The goal for this study was to characterize swine brain development using noninvasive MRI measures of microstructural and cerebrovascular changes. Thirteen pigs at various postnatal ages (2.3-43.5 kg) were imaged on a 1.5-Tesla MRI system. Microstructural changes were assessed using diffusion tensor imaging measures of mean diffusivity and fractional anisotropy. Cerebrovascular changes were assessed using arterial spin labeling measures of baseline cerebral blood flow (CBF) and the cerebrovascular reactivity (CVR) of the blood-oxygen level dependent (BOLD) MRI signal to CO2. We found a positive logarithmic relationship for regional tissue volumes and fractional anisotropy with body weight, which is similar to the pattern reported in the developing human brain. Unlike in the maturing human brain, no consistent changes in mean diffusivity or baseline CBF with development were observed. Changes in BOLD CVR exhibited a positive logarithmic relationship with body weight, which may impact the interpretation of functional MRI results at different stages of development. This animal model can be validated by applying the same noninvasive measures in humans.


Asunto(s)
Envejecimiento , Encéfalo/irrigación sanguínea , Encéfalo/crecimiento & desarrollo , Circulación Cerebrovascular , Imagen por Resonancia Magnética , Factores de Edad , Animales , Peso Corporal , Dióxido de Carbono/sangre , Imagen de Difusión por Resonancia Magnética , Espiración , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Modelos Lineales , Modelos Animales , Oxígeno/sangre , Presión Parcial , Flujo Sanguíneo Regional , Porcinos
17.
Curr Oncol ; 28(1): 549-559, 2021 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-33477698

RESUMEN

BACKGROUND: The purpose of our study was to characterize clinical features among brain metastasis (BM) patients who were long term survivors (LTS). METHODS: We reviewed a registry of BM patients referred to our multidisciplinary BM clinic between 2006 and 2014 and identified 97 who lived ≥ 3 years following BM diagnosis. The clinical and treatment characteristics were obtained from a prospectively maintained database, and additional information was obtained through review of electronic medical records and radiologic images. Survival analyses were performed using the Kaplan-Meier method. RESULTS: Median follow up for LTS was 67 months (range 36-181). Median age was 54 years, 65% had single BM, 39% had stable extracranial disease at the time of BM treatment, and brain was the first site of metastasis in 76%. Targetable mutations were present in 39% of patients and 66% received treatment with targeted-, hormonal-, or immuno-therapy. Brain surgery at the time of diagnosis was performed in 40% and stereotactic radiosurgery (SRS) or whole brain radiotherapy (alone or combination) in 52% and 56%, respectively. Following initial BM treatment, 5-year intracranial disease-free survival was 39%, and the cumulative incidence of symptomatic radio-necrosis was 16%. Five and ten-year overall survival was 72% and 26%, respectively. CONCLUSION: Most LTS were younger than 60 years old and had a single BM. Many received treatment with surgery or targeted, immune, or hormonal therapy.


Asunto(s)
Neoplasias Encefálicas , Radiocirugia , Encéfalo , Neoplasias Encefálicas/terapia , Humanos , Persona de Mediana Edad , Supervivencia sin Progresión , Análisis de Supervivencia
18.
Lung Cancer ; 155: 34-39, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33721614

RESUMEN

INTRODUCTION: Patients with EGFR-mutated (EGFRm) non-small cell lung cancer (NSCLC) are at particularly high risk of developing brain metastases (BrM). In addition to EGFR targeting tyrosine kinase inhibitors (TKI), radiosurgery (SRS) has an important role in the management of EGFRm BrM. However, data specific to the response and toxicity of EGFRm BrM to SRS are sparse. We evaluated the incidence of local failure (LF) and toxicity of EGFRm and EGFR-wild-type (EGFRwt) BrM treated with SRS. METHODS: We analyzed a prospective registry of BrM patients treated at our centre between 2008 and 2017 and identified EGFRm and EGFRwt NSCLC patients treated with SRS ±â€¯systemic therapy for BrM. Incidences of local failure (LF) and radionecrosis (RN) were determined, and Cox regression was performed for univariate and multivariate analyses (MVAs). RESULTS: We analyzed data from 218 patients (615 lesions - 225 EGFRm and 390 EGFRwt). Median imaging follow-up per patient was 14.5 months (0.5-96.3). Prior to or concomitant with SRS, 62 % of EGFRm patients received TKI and 93 % received TKI post SRS. The 24-month incidence of LF was 6% and 16 % for EGFRm BrM and EGFRwt, respectively (0.43(0.19-0.95); p = 0.037). The 24-month incidence of RN was 4% and 6% for EGFRm and EGFRwt BrM, respectively (0.8(0.32-1.98) p = 0.63). On MVA, BrM size and prescription dose (PD) significantly correlated with a higher risk of LF and BrM size correlated with a higher risk of RN. CONCLUSION: We observed excellent rates of response and toxicity following SRS in EGFRm compared to EGFRwt NSCLC, suggesting that EGFRm BrM have a favourable risk benefit ratio compared to EGFRwt NSCLC.


Asunto(s)
Neoplasias Encefálicas , Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Radiocirugia , Neoplasias Encefálicas/secundario , Neoplasias Encefálicas/cirugía , Carcinoma de Pulmón de Células no Pequeñas/genética , Receptores ErbB/genética , Humanos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Mutación , Estudios Retrospectivos
19.
J Magn Reson Imaging ; 31(2): 298-304, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20099341

RESUMEN

PURPOSE: To evaluate the reproducibility and gender differences in cerebrovascular reactivity (CVR) measurements obtained using the blood-oxygen level dependent (BOLD) response to controlled changes in end-tidal partial pressure of carbon dioxide (PETCO(2)). MATERIALS AND METHODS: We obtained ethical approval to image 19 healthy volunteers (10 men, 9 women) on a 1.5 Tesla (T) MRI scanner twice on two separate days using identical procedures. CVR images were generated by collecting BOLD MRI data during controlled changes in PETCO(2) induced by a sequential gas delivery system. RESULTS: Using the intraclass correlation coefficient (ICC), we demonstrated excellent within-day CVR measures in gray matter (GM) (ICC = 0.92) and white matter (WM) (ICC = 0.88) regions, excellent between-day reproducibility in GM (ICC = 0.81), and good between-day reproducibility in the WM (ICC = 0.66). CVR values between men and women were significantly different in the GM and WM. Men exhibited a 22 +/- 2% greater CVR in GM and a 17 +/- 2% greater CVR in WM compared with females. CONCLUSION: Our results demonstrate the reliability of BOLD MRI CVR measurements obtained using a controlled cerebrovascular challenge. Using this technique, we also revealed significantly increased BOLD response to CO(2) in males compared with females.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Encéfalo/fisiología , Dióxido de Carbono/administración & dosificación , Circulación Cerebrovascular/fisiología , Imagen por Resonancia Magnética/métodos , Oxígeno/metabolismo , Intercambio Gaseoso Pulmonar/fisiología , Velocidad del Flujo Sanguíneo/efectos de los fármacos , Encéfalo/irrigación sanguínea , Encéfalo/efectos de los fármacos , Circulación Cerebrovascular/efectos de los fármacos , Femenino , Humanos , Masculino , Intercambio Gaseoso Pulmonar/efectos de los fármacos , Factores Sexuales , Vasodilatación/efectos de los fármacos , Vasodilatación/fisiología
20.
J Magn Reson Imaging ; 32(5): 1068-75, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21031510

RESUMEN

PURPOSE: To demonstrate the feasibility and repeatability of cerebrovascular reactivity (CVR) imaging using a controlled CO(2) challenge in mechanically ventilated juvenile pigs. MATERIALS AND METHODS: Precise end-tidal partial pressure CO(2) (PETCO(2)) control was achieved via a computer-controlled model-driven prospective end-tidal targeting (MPET) system integrated with mechanical ventilation using a custom-built secondary breathing circuit. Test-retest blood-oxygen level dependent (BOLD) CVR images were collected in nine juvenile pigs by quantifying the BOLD response to iso-oxic square-wave PETCO(2) changes. For comparison, test-retest baseline arterial spin labeling (ASL) cerebral blood flow (CBF) images were collected. Repeatability was quantified using the intra-class correlation coefficient (ICC) and coefficient of variation (CV). RESULTS: The repeatability of the PETCO(2) (CV < 2%) step changes resulted in BOLD CVR ICC > 0.94 and CV < 6% for cortical brain regions, which was similar to ASL CBF repeatability (ICC > 0.96 and CV < 4%). CONCLUSION: This study demonstrates the feasibility and precision of CVR imaging with an MPET CO(2) challenge in mechanically ventilated subjects using an animal model. Translation of this method into clinical imaging protocols may enable CVR imaging in young children with cerebrovascular disease who require general anesthesia.


Asunto(s)
Anestesia Intravenosa , Velocidad del Flujo Sanguíneo , Circulación Cerebrovascular , Imagen por Resonancia Magnética , Respiración Artificial , Animales , Dióxido de Carbono/sangre , Masculino , Oxígeno/administración & dosificación , Oxígeno/sangre , Respiración Artificial/métodos , Procesamiento de Señales Asistido por Computador , Sus scrofa , Volumen de Ventilación Pulmonar
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA