1.
Magn Reson Med ; 69(1): 171-8, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22457233

RESUMEN

The feasibility of shutter-speed model dynamic-contrast-enhanced MRI pharmacokinetic analyses for prostate cancer detection was investigated in a prebiopsy patient cohort. Differences of results from the fast-exchange-regime-allowed (FXR-a) shutter-speed model version and the fast-exchange-limit-constrained (FXL-c) standard model are demonstrated. Although the spatial information is more limited, postdynamic-contrast-enhanced MRI biopsy specimens were also examined. The MRI results were correlated with the biopsy pathology findings. Of all the model parameters, region-of-interest-averaged K(trans) difference [ΔK(trans) ≡ K(trans)(FXR-a) - K(trans)(FXL-c)] or two-dimensional K(trans)(FXR-a) vs. k(ep)(FXR-a) values were found to provide the most useful biomarkers for malignant/benign prostate tissue discrimination (at 100% sensitivity for a population of 13, the specificity is 88%) and disease burden determination. (The best specificity for the fast-exchange-limit-constrained analysis is 63%, with the two-dimensional plot.) K(trans) and k(ep) are each measures of passive transcapillary contrast reagent transfer rate constants. Parameter value increases with shutter-speed model (relative to standard model) analysis are larger in malignant foci than in normal-appearing glandular tissue. Pathology analyses verify the shutter-speed model (FXR-a) promise for prostate cancer detection. Parametric mapping may further improve pharmacokinetic biomarker performance.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico , Anciano , Humanos , Aumento de la Imagen , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
2.
Clin Cancer Res ; 19(24): 6902-11, 2013 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-24132922

RESUMEN

PURPOSE: We conducted a phase I trial of the addition of sorafenib to a chemoradiotherapy regimen in patients with high-risk (intermediate/high grade, >5 cm) extremity soft tissue sarcoma undergoing limb salvage surgery. We conducted a correlative study of quantitative dynamic contrast-enhanced MRI (DCE-MRI) to assess response to treatment. EXPERIMENTAL DESIGN: Patients were treated at increasing dose levels of sorafenib (200 mg daily, 400 mg daily, 400 mg twice daily) initiated 14 days before three preoperative and three postoperative cycles of epirubicin/ifosfamide. Radiation (28 Gy) was administered during cycle 2 with epirubicin omitted. The primary objective was to determine the maximum tolerated dose (MTD) of sorafenib. DCE-MRI was conducted at baseline, after 2 weeks of sorafenib, and before surgery. The imaging data were subjected to quantitative pharmacokinetic analyses. RESULTS: Eighteen subjects were enrolled, of which 16 were evaluable. The MTD of sorafenib was 400 mg daily. Common grade 3-4 adverse events included neutropenia (94%), hypophosphatemia (75%), anemia (69%), thrombocytopenia (50%), and neutropenic fever/infection (50%). Of note, 38% developed wound complications requiring surgical intervention. The rate of ≥95% histopathologic tumor necrosis was 44%. Changes in DCE-MRI biomarker ΔK(trans) after 2 weeks of sorafenib correlated with histologic response (R(2) = 0.67, P = 0.012) at surgery. CONCLUSION: The addition of sorafenib to preoperative chemoradiotherapy is feasible and warrants further investigation in a larger trial. DCE-MRI detected changes in tumor perfusion after 2 weeks of sorafenib and may be a minimally invasive tool for rapid assessment of drug effect in soft tissue sarcoma.


Asunto(s)
Niacinamida/análogos & derivados , Compuestos de Fenilurea/administración & dosificación , Sarcoma/tratamiento farmacológico , Sarcoma/radioterapia , Adulto , Quimioradioterapia , Terapia Combinada , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Dosis Máxima Tolerada , Persona de Mediana Edad , Estadificación de Neoplasias , Niacinamida/administración & dosificación , Periodo Preoperatorio , Radiografía , Sarcoma/diagnóstico por imagen , Sarcoma/patología , Sorafenib , Adulto Joven
3.
J Magn Reson ; 218: 77-85, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22578558

RESUMEN

Prostate Dynamic-Contrast-Enhanced (DCE) MRI often exhibits fast and extensive global contrast reagent (CR) extravasation - measured by K(trans), a pharmacokinetic parameter proportional to its rate. This implies that the CR concentration [CR] is high in the extracellular, extravascular space (EES) during a large portion of the DCE-MRI study. Since CR is detected indirectly, through water proton signal change, the effects of equilibrium transcytolemmal water exchange may be significant in the data and thus should be admitted in DCE-MRI pharmacokinetic modeling. The implications for parameter values were investigated through simulations, and analyses of actual prostate data, with different models. Model parameter correlation and precision were also explored. A near-optimal version of the exchange-sensitized model was found. Our results indicate that ΔK(trans) (the K(trans) difference returned by this version and a model assuming exchange to be effectively infinitely fast) may be a very useful biomarker for discriminating malignant from benign prostate tissue. Using an exchange-sensitized model, we find that the mean intracellular water lifetime (τ(i)) - an exchange measure - can be meaningfully mapped for the prostate. Our results show prostate glandular zone differences in τ(i) values.


Asunto(s)
Agua Corporal/metabolismo , Membrana Celular/metabolismo , Imagen por Resonancia Magnética/métodos , Próstata/anatomía & histología , Próstata/metabolismo , Anciano , Biomarcadores , Biopsia , Membrana Celular/química , Medios de Contraste , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Modelos Biológicos , Farmacocinética , Neoplasias de la Próstata/diagnóstico , Protones , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS