1.
Cytometry A ; 101(8): 630-638, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35150049

RESUMEN

As label-free biomarkers, bioelectrical properties of single cells have been widely used in hematology analyzers for 3-part differential of leukocytes, in which, however, instrument dependent bioelectrical parameters (e.g., DC/AC impedance values) rather than inherent bioelectrical parameters (e.g., diameter Dc , specific membrane capacitance Csm and cytoplasmic conductivity σcy ) were used, leading to poor comparisons among different instruments. In order to address this issue, this study collected inherent bioelectrical parameters from hundreds of thousands of white blood cells based on a home-developed impedance flow cytometry with corresponding 3-part differential of leukocytes realized. More specifically, leukocytes were separated into three major subtypes of granulocytes, monocytes and lymphocytes based on density gradient centrifugation. Then these separated cells were aspirated through a constriction-microchannel based impedance flow cytometry where inherent bioelectrical parameters of Dc , Csm and σcy were quantified as 9.8 ± 0.7 µm, 2.06 ± 0.26 µF/cm2 , and 0.34 ± 0.05 S/m for granulocytes (ncell  = 134,829); 10.4 ± 1.0 µm, 2.45 ± 0.48 µF/cm2 , and 0.42 ± 0.08 S/m for monocytes (ncell  = 40,226); 8.0 ± 0.5 µm, 2.23 ± 0.34 µF/cm2 , and 0.35 ± 0.08 S/m for lymphocytes (ncell  = 129,193). Based on these inherent bioelectrical parameters, neural pattern recognition was conducted, producing a high "classification accuracy" of 93.5% in classifying these three subtypes of leukocytes. These results indicate that as inherent bioelectrical parameters, Dc , Csm , and σcy can be used to electrically phenotype white blood cells in a label-free manner.


Asunto(s)
Leucocitos , Membrana Celular , Capacidad Eléctrica , Impedancia Eléctrica , Citometría de Flujo
2.
J Med Internet Res ; 24(1): e28036, 2022 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-35076405

RESUMEN

BACKGROUND: The use of artificial intelligence (AI) in the medical domain has attracted considerable research interest. Inference applications in the medical domain require energy-efficient AI models. In contrast to other types of data in visual AI, data from medical laboratories usually comprise features with strong signals. Numerous energy optimization techniques have been developed to relieve the burden on the hardware required to deploy a complex learning model. However, the energy efficiency levels of different AI models used for medical applications have not been studied. OBJECTIVE: The aim of this study was to explore and compare the energy efficiency levels of commonly used machine learning algorithms-logistic regression (LR), k-nearest neighbor, support vector machine, random forest (RF), and extreme gradient boosting (XGB) algorithms, as well as four different variants of neural network (NN) algorithms-when applied to clinical laboratory datasets. METHODS: We applied the aforementioned algorithms to two distinct clinical laboratory data sets: a mass spectrometry data set regarding Staphylococcus aureus for predicting methicillin resistance (3338 cases; 268 features) and a urinalysis data set for predicting Trichomonas vaginalis infection (839,164 cases; 9 features). We compared the performance of the nine inference algorithms in terms of accuracy, area under the receiver operating characteristic curve (AUROC), time consumption, and power consumption. The time and power consumption levels were determined using performance counter data from Intel Power Gadget 3.5. RESULTS: The experimental results indicated that the RF and XGB algorithms achieved the two highest AUROC values for both data sets (84.7% and 83.9%, respectively, for the mass spectrometry data set; 91.1% and 91.4%, respectively, for the urinalysis data set). The XGB and LR algorithms exhibited the shortest inference time for both data sets (0.47 milliseconds for both in the mass spectrometry data set; 0.39 and 0.47 milliseconds, respectively, for the urinalysis data set). Compared with the RF algorithm, the XGB and LR algorithms exhibited a 45% and 53%-60% reduction in inference time for the mass spectrometry and urinalysis data sets, respectively. In terms of energy efficiency, the XGB algorithm exhibited the lowest power consumption for the mass spectrometry data set (9.42 Watts) and the LR algorithm exhibited the lowest power consumption for the urinalysis data set (9.98 Watts). Compared with a five-hidden-layer NN, the XGB and LR algorithms achieved 16%-24% and 9%-13% lower power consumption levels for the mass spectrometry and urinalysis data sets, respectively. In all experiments, the XGB algorithm exhibited the best performance in terms of accuracy, run time, and energy efficiency. CONCLUSIONS: The XGB algorithm achieved balanced performance levels in terms of AUROC, run time, and energy efficiency for the two clinical laboratory data sets. Considering the energy constraints in real-world scenarios, the XGB algorithm is ideal for medical AI applications.


Asunto(s)
Inteligencia Artificial , Laboratorios Clínicos , Algoritmos , Conservación de los Recursos Energéticos , Humanos , Aprendizaje Automático
3.
Int J Mol Sci ; 23(18)2022 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-36142574

RESUMEN

Background: We developed a hybrid platform using a negative combined with a positive selection strategy to capture circulating tumor cells (CTCs) and detect epidermal growth factor receptor (EGFR) mutations in patients with metastatic lung adenocarcinoma. Methods: Blood samples were collected from patients with pathology-proven treatment-naïve stage IV lung adenocarcinoma. Genomic DNA was extracted from CTCs collected for EGFR mutational tests. The second set of CTC-EGFR mutational tests were performed after three months of anti-cancer therapy. Results: A total of 80 samples collected from 28 patients enrolled between July 2016 and August 2018. Seventeen patients had EGFR mutations, including Exon 19 deletion (n = 11), L858R (n = 5), and de-novo T790 and L858R (n = 1). Concordance between tissue and CTCs before treatment was 88.2% in EGFR- mutant patients and 90.9% in non-mutant patients. The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of EGFR mutation tests for CTCs were 89.3%, 88.2%, 90.9%, 93.8%, and 83.3%, respectively. Conclusions: CTCs captured by a hybrid platform using a negative and positive selection strategy may serve as a suitable and reliable source of lung cancer tumor DNA for detecting EGFR mutations, including T790M.


Asunto(s)
Adenocarcinoma del Pulmón , Receptores ErbB/genética , Neoplasias Pulmonares , Células Neoplásicas Circulantes , Adenocarcinoma del Pulmón/genética , Humanos , Neoplasias Pulmonares/patología , Mutación , Células Neoplásicas Circulantes/patología , Inhibidores de Proteínas Quinasas
4.
Epilepsy Behav ; 103(Pt A): 106843, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31882325

RESUMEN

INTRODUCTION: The choice of subdural grid (SDG) or stereoelectroencephalography (sEEG) for patients with epilepsy can be complex and in some cases overlap. Comparing postoperative pain and narcotics consumption with SDG or sEEG can help develop an intracranial monitoring strategy. MATERIALS AND METHODS: A retrospective study was performed for adult patients undergoing SDG or sEEG monitoring. Numeric Rating Scale (NRS) was used for pain assessment. Types and dosage of the opioids were calculated by converting into milligram morphine equivalents (MME). Narcotic consumption was analyzed at the following three time periods: I. the first 24 h of implantation; II. from the second postimplantation day to the day of explantation; and III. the days following electrode removal to discharge. RESULTS: Forty-two patients who underwent SDG and 31 patients who underwent sEEG implantation were analyzed. After implantation, average NRS was 3.7 for SDG and 2.2 for sEEG (P < .001). After explantation, the NRS was 3.5 for SDG and 1.4 in sEEG (P < .001). Sixty percent of SDG patients and 13% of sEEG patients used more than one opioid in period III (P < .001). The SDG group had a significantly higher MME throughout the three periods compared with the sEEG group: period I: 448 (SDG) vs. 205 (sEEG) mg, P = .002; period II: 377 (SDG) vs. 102 (sEEG) mg, P < .001; and period III: 328 (SDG) vs. 75 (sEEG) mg; P = .002. Patients with the larger SDG implantation had the higher NRS (P = .03) and the higher MME at period I (P = .019). There was no correlation between the number of depth electrodes and pain control in patients with sEEG. CONCLUSIONS: Patients undergoing sEEG had significantly less pain and required fewer opiates compared with patients with SDG. These differences in perioperative pain may be a consideration when choosing between these two invasive monitoring options.


Asunto(s)
Analgésicos Opioides/administración & dosificación , Electrocorticografía/métodos , Electrodos Implantados , Electroencefalografía/métodos , Dolor Postoperatorio/tratamiento farmacológico , Técnicas Estereotáxicas , Adulto , Epilepsia Refractaria/diagnóstico por imagen , Epilepsia Refractaria/tratamiento farmacológico , Epilepsia Refractaria/cirugía , Electrocorticografía/normas , Electrodos Implantados/normas , Electroencefalografía/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Narcóticos/administración & dosificación , Dimensión del Dolor/métodos , Dimensión del Dolor/normas , Dolor Postoperatorio/diagnóstico por imagen , Estudios Retrospectivos , Técnicas Estereotáxicas/normas
5.
J Med Internet Res ; 22(8): e20261, 2020 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-32763879

RESUMEN

BACKGROUND: Colorectal cancer screening by fecal occult blood testing has been an important public health test and shown to reduce colorectal cancer-related mortality. However, the low participation rate in colorectal cancer screening by the general public remains a problematic public health issue. This fact could be attributed to the complex and unpleasant operation of the screening tool. OBJECTIVE: This study aimed to validate a novel toilet paper-based point-of-care test (ie, JustWipe) as a public health instrument to detect fecal occult blood and provide detailed results from the evaluation of the analytic characteristics in the clinical validation. METHODS: The mechanism of fecal specimen collection by the toilet-paper device was verified with repeatability and reproducibility tests. We also evaluated the analytical characteristics of the test reagents. For clinical validation, we conducted comparisons between JustWipe and other fecal occult blood tests. The first comparison was between JustWipe and typical fecal occult blood testing in a central laboratory setting with 70 fecal specimens from the hospital. For the second comparison, a total of 58 volunteers were recruited, and JustWipe was compared with the commercially available Hemoccult SENSA in a point-of-care setting. RESULTS: Adequate amounts of fecal specimens were collected using the toilet-paper device with small day-to-day and person-to-person variations. The limit of detection of the test reagent was evaluated to be 3.75 µg of hemoglobin per milliliter of reagent. Moreover, the test reagent also showed high repeatability (100%) on different days and high reproducibility (>96%) among different users. The overall agreement between JustWipe and a typical fecal occult blood test in a central laboratory setting was 82.9%. In the setting of point-of-care tests, the overall agreement between JustWipe and Hemoccult SENSA was 89.7%. Moreover, the usability questionnaire showed that the novel test tool had high scores in operation friendliness (87.3/100), ease of reading results (97.4/100), and information usefulness (96.1/100). CONCLUSIONS: We developed and validated a toilet paper-based fecal occult blood test for use as a point-of-care test for the rapid (in 60 seconds) and easy testing of fecal occult blood. These favorable characteristics render it a promising tool for colorectal cancer screening as a public health instrument.


Asunto(s)
Aparatos Sanitarios/provisión & distribución , Neoplasias Colorrectales/diagnóstico , Tamizaje Masivo/métodos , Sangre Oculta , Pruebas en el Punto de Atención/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Encuestas y Cuestionarios , Voluntarios
6.
J Neurooncol ; 142(3): 577-586, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30805752

RESUMEN

PURPOSE: Awake craniotomy is well-established for tumors resected in eloquent brain areas. Whether awake craniotomy provides improved seizure control in patients with epileptic gliomas has not been well evaluated. This study analyzed the incidence, risk factors and outcome of seizures during and following awake craniotomies for patients presenting with epilepsy and glioma. METHODS: Forty-one patients undergoing awake craniotomies for epileptic gliomas were retrospectively analyzed. Postoperative seizure was defined as either early (postoperative day 7 + before) or late onset (after postoperative day 7). Neurologic function was assessed with modified Rankin Scales (mRS) and seizure outcome was assessed using International League Against Epilepsy (ILAE) classification. Multivariable logistic regression was used for clinical variables associated with postoperative seizures. RESULTS: Three patients (7.3%) had intraoperative seizures however did not fail the awake craniotomies. Mean mRS before and after the awake craniotomies were 2.4 and 2.1, respectively (P = 0.032). Fourteen (34.1%) patients had early seizures, which caused longer hospitalization than those without early seizures (P = 0.03). Surgical resection to isocitrate dehydrogenase 1 (IDH1) mutation tumors, comparing to IDH1 wild type tumors, caused better postoperative seizure control. 6-month late seizure freedom was achieved in 33 patients (80.5%). Early seizure recurrence (odds ratio = 30.75; P = 0.039) and postoperative mRS ≥ 3 (odds ratio = 7.00; P = 0.047) were independent risk factors for late seizures. CONCLUSIONS: Intraoperative seizures could be well-controlled during awake craniotomies. Early postoperative seizures extended hospitalization and strongly predicted late seizure recurrence. Awake craniotomies benefited long-term seizure control in patients with epileptic gliomas.


Asunto(s)
Craneotomía/métodos , Epilepsia/cirugía , Glioma/cirugía , Complicaciones Intraoperatorias/prevención & control , Complicaciones Posoperatorias/prevención & control , Convulsiones/prevención & control , Vigilia , Adulto , Neoplasias Encefálicas/complicaciones , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/cirugía , Epilepsia/complicaciones , Epilepsia/patología , Femenino , Estudios de Seguimiento , Glioma/complicaciones , Glioma/patología , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos
7.
Cytometry A ; 93(8): 822-828, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-30063818

RESUMEN

As label-free biomarkers, the mechanical properties of nuclei are widely treated as promising biomechanical markers for cell type classification and cellular status evaluation. However, previously reported mechanical parameters were derived from only around 10 nuclei, lacking statistical significances due to low sample numbers. To address this issue, nuclei were first isolated from SW620 and A549 cells, respectively, using a chemical treatment method. This was followed by aspirating them through two types of microfluidic constriction channels for mechanical property characterization. In this study, hundreds of nuclei were characterized, producing passage times of 0.5 ± 1.2 s for SW620 nuclei in type I constriction channel (n = 153), 0.045 ± 0.047 s for SW620 nuclei in type II constriction channel (n = 215) and 0.50 ± 0.86 s for A549 nuclei in type II constriction channel. In addition, neural network based pattern recognition was used to classify the nuclei isolated from SW620 and A549 cells, producing successful classification rates of 87.2% for diameters of nuclei, 85.5% for passage times of nuclei and 89.3% for both passage times and diameters of nuclei. These results indicate that the characterization of the mechanical properties of nuclei may contribute to the classification of different tumor cells.


Asunto(s)
Núcleo Celular/química , Citoplasma/química , Técnicas Analíticas Microfluídicas , Análisis de la Célula Individual , Células A549 , Membrana Celular , Constricción , Humanos , Fenómenos Mecánicos
8.
Intern Med J ; 48(6): 661-667, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29193638

RESUMEN

BACKGROUND: Delayed detection of atrial fibrillation (AF) is common in patients with stroke. However, it is not well known whether delayed identification of AF in patients with stroke affects the prognosis of patients. AIMS: To evaluate the association between the timing of AF diagnosis after stroke and clinical outcomes. METHODS: We identified a cohort of all patients admitted with a primary diagnosis of first-ever ischaemic stroke, which was categorised into three groups, namely, non-AF, AF presenting with stroke and delayed AF diagnosis groups. The study patients were individually followed for 5 years to evaluate the occurrence of recurrent stroke and death. RESULTS: In total, 17 399 patients were hospitalised with first-ever ischemic stroke, of whom 16 261 constituted the non-AF group, 907 the AF presenting with stroke group and 231 the delayed AF diagnosis group. During the 5-year follow up, 2773 (17.1%), 175 (19.3%) and 68 (29.4%) patients in the non-AF, AF presenting with stroke and delayed AF diagnosis groups, respectively, were hospitalised for recurrent stroke. The delayed AF diagnosis group exhibited a 1.57-times higher risk of recurrent stroke than the AF presenting with stroke group, after adjustment for the CHA2DS2-VASc scores (adjusted hazard ratio (HR): 1.57; 95% confidence interval (CI) = 1.19-2.08; P = 0.002). In addition, delayed diagnosis of AF significantly increased the risk of recurrent stroke in men, but not in women, after adjustment for the CHA2DS2-VASc scores. CONCLUSION: Delayed diagnosis of AF after stroke increased the risk of recurrent stroke, particularly in men.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Diagnóstico Tardío/estadística & datos numéricos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/mortalidad , Anciano , Bases de Datos Factuales , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Taiwán/epidemiología
9.
Int J Mol Sci ; 18(6)2017 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-28629175

RESUMEN

This paper presents the instrumentation of a microfluidic analyzer enabling the characterization of single-cell biophysical properties, which includes seven key components: a microfluidic module, a pressure module, an imaging module, an impedance module, two LabVIEW platforms for instrument operation and raw data processing, respectively, and a Python code for data translation. Under the control of the LabVIEW platform for instrument operation, the pressure module flushes single cells into the microfluidic module with raw biophysical parameters sampled by the imaging and impedance modules and processed by the LabVIEW platform for raw data processing, which were further translated into intrinsic cellular biophysical parameters using the code developed in Python. Based on this system, specific membrane capacitance, cytoplasm conductivity, and instantaneous Young's modulus of three cell types were quantified as 2.76 ± 0.57 µF/cm², 1.00 ± 0.14 S/m, and 3.79 ± 1.11 kPa for A549 cells (ncell = 202); 1.88 ± 0.31 µF/cm², 1.05 ± 0.16 S/m, and 3.74 ± 0.75 kPa for 95D cells (ncell = 257); 2.11 ± 0.38 µF/cm², 0.87 ± 0.11 S/m, and 5.39 ± 0.89 kPa for H460 cells (ncell = 246). As a semi-automatic instrument with a throughput of roughly 1 cell per second, this prototype instrument can be potentially used for the characterization of cellular biophysical properties.


Asunto(s)
Membrana Celular/química , Módulo de Elasticidad , Capacidad Eléctrica , Conductividad Eléctrica , Técnicas Analíticas Microfluídicas/instrumentación , Microfluídica/instrumentación , Análisis de la Célula Individual/instrumentación , Fenómenos Biofísicos , Técnicas Biosensibles/instrumentación , Citoplasma , Impedancia Eléctrica , Procesamiento Automatizado de Datos , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/métodos , Análisis de la Célula Individual/métodos
10.
Sensors (Basel) ; 15(8): 18801-12, 2015 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-26263992

RESUMEN

This study reports a piezoelectric poly(vinylidene fluoride) (PVDF) polymer-based sensor patch for respiration detections in dynamic walking condition. The working mechanism of respiration signal generation is based on the periodical deformations on a human chest wall during the respiratory movements, which in turn mechanically stretch the piezoelectric PVDF film to generate the corresponding electrical signals. In this study, the PVDF sensing film was completely encapsulated within the sensor patch forming a mass-spring-damper mechanical system to prevent the noises generated in a dynamic condition. To verify the design of sensor patch to prevent dynamic noises, experimental investigations were carried out. Results demonstrated the respiration signals generated and the respiratory rates measured by the proposed sensor patch were in line with the same measurements based on a commercial respiratory effort transducer both in a static (e.g., sitting) or dynamic (e.g., walking) condition. As a whole, this study has developed a PVDF-based sensor patch which is capable of monitoring respirations in a dynamic walking condition with high fidelity. Other distinctive features include its small size, light weight, ease of use, low cost, and portability. All these make it a promising sensing device to monitor respirations particularly in home care units.


Asunto(s)
Electricidad , Monitoreo Fisiológico/instrumentación , Polímeros/química , Polivinilos/química , Respiración , Caminata/fisiología , Humanos , Procesamiento de Señales Asistido por Computador
11.
Sensors (Basel) ; 15(3): 6789-806, 2015 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-25808775

RESUMEN

This study reports a microfluidic-based optical sensing device for label-free detection of circulating tumor cells (CTCs), a rare cell species in blood circulation. Based on the metabolic features of cancer cells, live CTCs can be quantified indirectly through their lactic acid production. Compared with the conventional schemes for CTC detection, this label-free approach could prevent the biological bias due to the heterogeneity of the surface antigens on cancer cells. In this study, a microfluidic device was proposed to generate uniform water-in-oil cell-encapsulating micro-droplets, followed by the fluorescence-based optical detection of lactic acid produced within the micro-droplets. To test its feasibility to quantify cancer cells, experiments were carried out. Results showed that the detection signals were proportional to the number of cancer cells within the micro-droplets, whereas such signals were insensitive to the existence and number of leukocytes within. To further demonstrate its feasibility for cancer cell detection, the cancer cells with known cell number in a cell suspension was detected based on the method. Results revealed that there was no significant difference between the detected number and the real number of cancer cells. As a whole, the proposed method opens up a new route to detect live CTCs in a label-free manner.


Asunto(s)
Técnicas Biosensibles , Técnicas Analíticas Microfluídicas , Neoplasias/diagnóstico , Células Neoplásicas Circulantes/metabolismo , Línea Celular Tumoral , Separación Celular , Supervivencia Celular , Humanos , Ácido Láctico/metabolismo , Leucocitos/metabolismo , Leucocitos/patología , Neoplasias/metabolismo , Células Neoplásicas Circulantes/patología , Dispositivos Ópticos
12.
Int J Mol Sci ; 16(5): 9804-30, 2015 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-25938973

RESUMEN

This article reviews recent developments in microfluidic impedance flow cytometry for high-throughput electrical property characterization of single cells. Four major perspectives of microfluidic impedance flow cytometry for single-cell characterization are included in this review: (1) early developments of microfluidic impedance flow cytometry for single-cell electrical property characterization; (2) microfluidic impedance flow cytometry with enhanced sensitivity; (3) microfluidic impedance and optical flow cytometry for single-cell analysis and (4) integrated point of care system based on microfluidic impedance flow cytometry. We examine the advantages and limitations of each technique and discuss future research opportunities from the perspectives of both technical innovation and clinical applications.


Asunto(s)
Citometría de Flujo/métodos , Ensayos Analíticos de Alto Rendimiento/métodos , Microfluídica/métodos , Análisis de la Célula Individual/métodos , Animales , Impedancia Eléctrica , Humanos , Sistemas de Atención de Punto
13.
Biomed Microdevices ; 16(3): 345-54, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24496886

RESUMEN

This study reports a microfluidic system for high throughput, uniform, and size-tunable generation of cell-containing collagen microbeads. The principle is based on two pneumatically-driven mechanisms to achieve multi-channel mixture suspension transportation, and to actuate the spotting actions of micro-vibrators that continuously generate tiny collagen micro-droplets into a thin oil layer and then a sterile Pluronic® F127 surfactant solution located below. The temporarily formed collagen microdroplets are then thermally gelatinized. By regulating the feeding rate of cells/collagen suspension, and the spotting frequency of micro-vibrator, the size of the collagen microbeads can be manipulated. One of the key technical features is its capability to generate uniform collagen microbeads (coefficient of variation: 5.4-8.6 %) with sizes ranging from 73.9 to 349.3 µm in diameter. This is currently difficult to achieve using the existing methods particularly the generation of cell-encapsulating collagen microbeads with diameter less than 100 µm. Another advantageous trait is that the ultrastructure of the generated collagen microbeads is similar to that found in native collagen. In this study, moreover, the use of the proposed device for the microencapsulation of 3T3 cells in collagen microbeads has been successfully demonstrated showing that the encapsulated cells maintained high cell viability (96 ± 2 %). Furthermore, a reasonable proliferative capability of the encapsulated cells was observed during 7 days culture. As a whole, the proposed device has opened up a new route to generate cell-containing collagen microbeads, which is found particularly meaningful for biomedical applications.


Asunto(s)
Colágeno/química , Técnicas Analíticas Microfluídicas/instrumentación , Microesferas , Animales , Cápsulas , Proliferación Celular , Supervivencia Celular , Células Inmovilizadas/citología , Diseño de Equipo
14.
Biosensors (Basel) ; 14(6)2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38920601

RESUMEN

Optically induced dielectrophoresis (ODEP)-based microparticle sorting and separation is regarded as promising. However, current methods normally lack the downstream process for the transportation and collection of separated microparticles, which could limit its applications. To address this issue, an ODEP microfluidic chip encompassing three microchannels that join only at the central part of the microchannels (i.e., the working zone) was designed. During operation, three laminar flows were generated in the zone, where two dynamic light bar arrays were designed to sort and separate PS (polystyrene) microbeads of different sizes in a continuous manner. The separated PS microbeads were then continuously transported in laminar flows in a partition manner for the final collection. The results revealed that the method was capable of sorting and separating PS microbeads in a high-purity manner (e.g., the microbead purity values were 89.9 ± 3.7, 88.0 ± 2.5, and 92.8 ± 6.5% for the 5.8, 10.8, and 15.8 µm microbeads harvested, respectively). Overall, this study demonstrated the use of laminar flow and ODEP to achieve size-based sorting, separation, and collection of microparticles in a continuous and high-performance manner. Apart from the demonstration, this method can also be utilized for size-based sorting and the separation of other biological or nonbiological microparticles.


Asunto(s)
Electroforesis , Técnicas Analíticas Microfluídicas , Microesferas , Tamaño de la Partícula , Poliestirenos , Microfluídica
15.
Cancers (Basel) ; 15(22)2023 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-38001632

RESUMEN

Analysis of circulating tumor cells (CTCs) holds promise to diagnose cancer or monitor its development. Among the methods, counting CTC numbers in blood samples could be the simplest way to implement it. Nevertheless, its clinical utility has not yet been fully accepted. The reasons could be due to the rarity and heterogeneity of CTCs in blood samples that could lead to misleading results from assays only based on single CTC counts. To address this issue, a feasible direction is to combine the CTC counts with other clinical data for analysis. Recent studies have demonstrated the use of this new strategy for early detection and prognosis evaluation of cancers, or even for the distinguishment of cancers with different stages. Overall, this approach could pave a new path to improve the technical problems in the clinical applications of CTC counting techniques. In this review, the information relevant to CTCs, including their characteristics, clinical use of CTC counting, and technologies for CTC enrichment, were first introduced. This was followed by discussing the challenges and new perspectives of CTC counting techniques for clinical applications. Finally, the advantages and the recent progress in combining CTC counts with other clinical parameters for clinical applications have been discussed.

16.
Diagnostics (Basel) ; 13(10)2023 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-37238189

RESUMEN

The current methods for detecting antiplatelet antibodies are mostly manual and labor-intensive. A convenient and rapid detection method is required for effectively detecting alloimmunization during platelet transfusion. In our study, to detect antiplatelet antibodies, positive and negative sera of random-donor antiplatelet antibodies were collected after completing a routine solid-phase red cell adherence test (SPRCA). Platelet concentrates from our random volunteer donors were also prepared using the ZZAP method and then used in a faster, significantly less labor-intensive process, a filtration enzyme-linked immunosorbent assay (fELISA), for detecting antibodies against platelet surface antigens. All fELISA chromogen intensities were processed using ImageJ software. By dividing the final chromogen intensity of each test serum with the background chromogen intensity of whole platelets, the reactivity ratios of fELISA can be used to differentiate positive SPRCA sera from negative sera. A sensitivity of 93.9% and a specificity of 93.3% were obtained for 50 µL of sera using fELISA. The area under the ROC curve reached 0.96 when comparing fELISA with the SPRCA test. We have successfully developed a rapid fELISA method for detecting antiplatelet antibodies.

17.
Biosensors (Basel) ; 13(11)2023 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-37998128

RESUMEN

For the rapid detection of bacteria in a blood sample, nucleic acid amplification-based assays are believed to be promising. Nevertheless, the nucleic acids released from the dead blood cells or bacteria could affect the assay performance. This highlights the importance of the isolation of live bacteria from blood samples. To address this issue, this study proposes a two-step process. First, a blood sample was treated with the immuno-magnetic microbeads-based separation to remove the majority of blood cells. Second, an optically induced dielectrophoresis (ODEP) microfluidic system with an integrated dynamic circular light image array was utilized to further isolate and purify the live bacteria from the remaining blood cells based on their size difference. In this work, the ODEP microfluidic system was developed. Its performance for the isolation and purification of bacteria was evaluated. The results revealed that the method was able to harvest the live bacteria in a high purity (90.5~99.2%) manner. Overall, the proposed method was proven to be capable of isolating and purifying high-purity live bacteria without causing damage to the co-existing cells. This technical feature was found to be valuable for the subsequent nucleic-acid-based bacteria detection, in which the interferences caused by the nontarget nucleic acids could be eliminated.


Asunto(s)
Técnicas Analíticas Microfluídicas , Ácidos Nucleicos , Microfluídica , Bacterias
18.
Clin Neurol Neurosurg ; 228: 107687, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36963286

RESUMEN

OBJECTIVE: Continuous cardiac monitoring on patients with aneurysmal subarachnoid hemorrhage (aSAH) is difficult out of intensive care unit (ICU) in the subacute stage. Therefore, we verified the feasibility of a novel electrocardiography (ECG) patch device to record long-term heart rhythm. METHODS: The ECG patches were applied on aSAH patients during their stay in general ward. Any types of significant arrythmia were identified, and heart rate variability (HRV) measures were calculated in time and frequency domains. We analyzed the correlation between heart rhythm with Hunt and Hess scale and modified Fisher scale as well as the occurrence of secondary complications. RESULTS: Twenty-six patients used the devices on median day 6 after aSAH onset, with put on and take down time average as 137 s and 45 s, respectively. Mean record time was 221.7 h, and no adverse event presented within the period. Hunt and Hess II/III subgroup had higher percentage of HRV high frequency band than IV/V subgroup (9.1 % vs 3.5 %, p = 0.043), whereas ultra low frequency band presented more in the later subgroup (50.4 % vs 61.4 %, p = 0.035). The very low frequency percentage significantly decreased (p = 0.025) at an average of 3 days prior to the occurrence of secondary complications compared to the days without complications. CONCLUSION: For aSAH patients in general ward during subacute stage, the ECG patch is a safe and feasible tool. The correlation of long-term heart rhythm with prognosis is worthy to be investigated on larger sample size using this device in the future.


Asunto(s)
Hemorragia Subaracnoidea , Humanos , Hemorragia Subaracnoidea/complicaciones , Estudios de Factibilidad , Pronóstico , Electrocardiografía
19.
Micromachines (Basel) ; 14(12)2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-38138338

RESUMEN

The analysis of circulating tumor cells (CTCs) at the molecular level holds great promise for several clinical applications. For this goal, the harvest of high-purity, size-sorted CTCs with different subtypes from a blood sample are important. For this purpose, a two-step CTC isolation protocol was proposed, by which the immunomagnetic beads-based cell separation was first utilized to remove the majority of blood cells. After that, an optically induced dielectrophoresis (ODEP) microfluidic system was developed to (1) purify the CTCs from the remaining magnetic microbeads-bound blood cells and to (2) sort and separate the CTCs with different sizes. In this study, the ODEP microfluidic system was designed and fabricated. Moreover, its optimum operation conditions and performance were explored. The results exhibited that the presented technique was able to purify and sort the cancer cells with two different sizes from a tested cell suspension in a high-purity (93.5% and 90.1% for the OECM 1 and HA22T cancer cells, respectively) manner. Overall, this study presented a technique for the purification and sorting of cancer cells with different sizes. Apart from this application, the technique is also useful for other applications in which the high-purity and label-free purification and sorting of cells with different sizes is required.

20.
Biosens Bioelectron ; 215: 114574, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-35926394

RESUMEN

We have developed a novel molecular diagnostic platform (photothermal bead-based nucleic acid amplification test; pbbNAAT) that greatly improves the low sensitivity of direct loop-mediated isothermal amplification (LAMP) and allows for specific detection of LAMP amplicons in complex samples. The pbbNAAT integrates specific ligand-functionalized polypyrrole-coated iron oxide particles (PPy@IOs) capable of photothermal conversion and single-molecule magnetic capture of target analytes, the released nucleic acid, and LAMP-amplified products under external light energy control and magnetic manipulations. This allows for sample pretreatment, pbbLAMP amplification, and subsequent amplicon detection with bead-based ELISA in a one-stop microreactor without loss. In addition, photonic heating with PPy@IOs and external light control provide instant and uniform heating for thermolysis and pbbLAMP implementations. Moreover, it generates higher primer annealing stringency for LAMP primers in pbbLAMP; thus, it can detect pathogen-specific DNA accurately and promptly in pathogen-spiked complex materials. The sample pretreatment procedure of pbbNAAT can greatly reduce inhibitors originating from complex samples, which enables the maintenance of maximal enzyme activities for highly sensitive detection. More importantly, the pbbLAMP assay coupled with magnetic capture permits subsequent bead-based ELISA detection to determine true positive LAMP amplicons on PPy@IOs. The pbbNAAT platform has a high tolerance to inhibitors originating from complex samples, high analytical specificity, and limitation of detection (LoD) as low as 8 CFU/reaction to detect E. coli spiked in human whole blood, bovine milk, and can be completed in less than 1 h. Therefore, we believe that pbbNAAT can serve as a suitable direct LAMP platform for on-site POCTs.


Asunto(s)
Técnicas Biosensibles , Polímeros , Escherichia coli , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico/métodos , Pruebas en el Punto de Atención , Pirroles , Sensibilidad y Especificidad