Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Br J Haematol ; 193(6): 1203-1212, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33954979

RESUMEN

A universal anti-Xa assay for the determination of rivaroxaban, apixaban and edoxaban drug concentrations would simplify laboratory procedures and facilitate widespread implementation. Following two pilot studies analysing spiked samples and material from 698 patients, we conducted a prospective multicentre cross-sectional study, including 867 patients treated with rivaroxaban, apixaban or edoxaban in clinical practice to comprehensively evaluate a simple, readily available anti-Xa assay that would accurately measure drug concentrations and correctly predict relevant levels in clinical practice. Anti-Xa activity was measured by an assay calibrated with low-molecular-weight heparin (LMWH) in addition to ultra-high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). As an external validation, LMWH-calibrated anti-Xa activity was also determined in nine external laboratories. The LMWH-calibrated anti-Xa activity correlated strongly with rivaroxaban, apixaban or edoxaban drug levels [rs  = 0·98, 95% confidence interval (CI) 0·98-0·98]. The sensitivity for the clinically relevant cut-off levels of 30, 50 and 100 µg/l was 96·2% (95% CI 94·4-97·4), 96·4% (95% CI 94·4-97·7) and 96·7% (95% CI 94·3-98·1) respectively. Concordant results were obtained in the external validation study. In conclusion, a universal, LMWH-calibrated anti-Xa assay accurately measured rivaroxaban, apixaban and edoxaban concentrations and correctly predicted relevant drug concentrations in clinical practice.


Asunto(s)
Ciclofosfamida/farmacocinética , Monitoreo de Drogas , Inhibidores del Factor Xa/sangre , Pirazoles/farmacocinética , Piridonas/farmacocinética , Rivaroxabán/farmacocinética , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cromatografía Líquida de Alta Presión , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Retrospectivos , Espectrometría de Masas en Tándem
2.
Immunity ; 34(2): 258-68, 2011 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-21349432

RESUMEN

Activated mast cells trigger edema in allergic and inflammatory disease. We report a paracrine mechanism by which mast cell-released heparin increases vascular permeability in vivo. Heparin activated the protease factor XII, which initiates bradykinin formation in plasma. Targeting factor XII or kinin B2 receptors abolished heparin-triggered leukocyte-endothelium adhesion and interfered with a mast cell-driven drop in blood pressure in rodents. Intravital laser scanning microscopy and tracer measurements showed heparin-driven fluid extravasation in mouse skin microvessels. Ablation of factor XII or kinin B2 receptors abolished heparin-induced skin edema and protected mice from allergen-activated mast cell-driven leakage. In contrast, heparin and activated mast cells induced excessive edema in mice deficient in the major inhibitor of factor XII, C1 esterase inhibitor. Allergen exposure triggered edema attacks in hereditary angioedema patients, lacking C1 esterase inhibitor. The data indicate that heparin-initiated bradykinin formation plays a fundamental role in mast cell-mediated diseases.


Asunto(s)
Bradiquinina/biosíntesis , Síndrome de Fuga Capilar/fisiopatología , Permeabilidad Capilar/fisiología , Heparina/fisiología , Mastocitos/metabolismo , Anafilaxis Cutánea Pasiva/fisiología , Animales , Bradiquinina/genética , Síndrome de Fuga Capilar/etiología , Adhesión Celular , Proteína Inhibidora del Complemento C1/fisiología , Edema/etiología , Edema/fisiopatología , Células Endoteliales/patología , Activación Enzimática , Factor XII/fisiología , Heparina/metabolismo , Hipotensión/etiología , Hipotensión/fisiopatología , Inmunoglobulina E/inmunología , Sistema Calicreína-Quinina/fisiología , Leucocitos/fisiología , Masculino , Ratones , Comunicación Paracrina/fisiología , Plasma , Ratas , Transducción de Señal/fisiología , Piel/irrigación sanguínea
3.
Eur J Anaesthesiol ; 36(6): 457-465, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30950901

RESUMEN

BACKGROUND: Major guidelines emphasise the potential of visco-elastic methods to overcome the limitations of conventional laboratory assays in the peri-operative setting. Their sensitivity regarding mild bleeding disorders (MBDs), the most common bleeding disorders in the general population, is however unknown. OBJECTIVE: The aim of this study was to investigate the sensitivity of thromboelastometry for diagnosis of MBD. DESIGN: A single-centre prospective cohort study. SETTING: Haematology outpatient unit of a tertiary general hospital in Central Switzerland. PATIENTS: All consecutive patients referred over a 32-month period with a suspected bleeding disorder were included and thromboelastometry was conducted using a ROTEM delta (EXTEM, INTEM and FIBTEM). Diagnostic work-up was performed according to current guidelines including the ISTH bleeding assessment tool (ISTH BAT). MAIN OUTCOME MEASURES: Distribution of clotting time (CT) and maximum clot firmness (MCF) results in relation to the presence of MBD. RESULTS: Two hundred and seventeen patients were assessed; the median [IQR] age was 39 years [28 to 57]; 151 patients were women (70%). MBD was diagnosed in 97 patients (45%), no MBD was found in 100 patients (46%) and a systemic disorder recognised in 20 patients (9%). Presence of MBD was not associated with a significant difference in thromboelastometry variables (0.2 s in CT EXTEM, 95% CI -2.3 to 2.7; -0.2 mm in MCF EXTEM, 95% CI -1.8 to 1.5; -0.7 s in CT INTEM, 95% CI -12.6 to 11.2; 0.6 mm in MCF INTEM, 95% CI -1.2 to 1.3; 0.8 mm in MCF FIBTEM, 95% CI -1.6 to 1.4) and most results were within the established reference ranges. CONCLUSION: Our data did not support the use of thromboelastometry as a diagnostic tool in patients with MBD.


Asunto(s)
Trastornos Hemorrágicos/diagnóstico , Tromboelastografía , Adulto , Estudios de Factibilidad , Femenino , Trastornos Hemorrágicos/sangre , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Suiza
4.
Allergy Asthma Proc ; 38(3): 216-221, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28441992

RESUMEN

BACKGROUND: Increased estrogen levels during pregnancy can exacerbate hereditary angioedema (HAE), yet disease and treatment ramifications remain poorly studied in pregnant women. OBJECTIVE: Data from the international Berinert Patient Registry were used to evaluate outcomes of pregnancies exposed to plasma-derived, pasteurized, nanofiltered C1-inhibitor concentrate (pnfC1-INH) during routine HAE management. METHODS: This observational registry, conducted between 2010 and 2014 at 30 U.S. and 7 European sites, gathered data on 318 subjects and 15,000 pnfC1-INH infusions. Whenever possible, the subjects who used pnfC1-INH during pregnancy were followed up to term to assess neonatal outcomes and to collect maternal adverse events (AE) that occurred up to 1 month after pnfC1-INH administration. RESULTS: The registry data base included 11 pregnancies in 10 subjects who used pnfC1-INH for HAE attack treatment and/or prophylaxis (>261 doses during pregnancy). Eight pregnancies concluded in the birth of a healthy baby. Of the remaining three pregnancies: one was voluntarily terminated at 9 weeks of gestation; a second ended as a first-trimester spontaneous abortion 1 week after the subject's most recent pnfC1-INH infusion and was considered unrelated to pnf-C1INH treatment; and the third occurred in a subject who exited the registry approximately 2 months before her due date, with no further follow up. As assessed for 30 days after each pnfC1-INH infusion, there were no AEs that were considered related to pnfC1-INH therapy. CONCLUSION: Administration of pnfC1-INH during pregnancy was generally safe and not associated with any treatment-related AEs. In all registry pregnancies followed up to term, the birth of a healthy baby was reported.


Asunto(s)
Angioedemas Hereditarios/tratamiento farmacológico , Proteína Inhibidora del Complemento C1/uso terapéutico , Adulto , Proteína Inhibidora del Complemento C1/administración & dosificación , Proteína Inhibidora del Complemento C1/efectos adversos , Femenino , Humanos , Embarazo , Complicaciones Cardiovasculares del Embarazo/tratamiento farmacológico , Resultado del Embarazo , Sistema de Registros , Adulto Joven
5.
Transfus Med Hemother ; 44(2): 78-83, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28503123

RESUMEN

BACKGROUND: Studies investigating thromboelastometry or thrombelastography analyses in a physiological context are scattered and not easy to access. OBJECTIVE: To systematically retrieve and describe published reports studying healthy subjects and targeting at the correlation of ROTEM® and TEG® measurements with conventional parameters of hemostasis. METHODS: Systematic Review: Papers were searched in Medline, Scopus and the Science Citation Index database. Reference lists of included studies and of reviews were screened. To be included papers had to report ROTEM or TEG data on healthy subjects. Two reviewers screened papers for inclusion, read full texts of potentially relevant papers, and extracted data of included papers. RESULTS: Searches identified 1,721 records of which 1,713 were either excluded immediately or after reading the full text. The remaining 8 studies enrolled 632 subjects. The association of conventional parameters of hemostasis with ROTEM and with TEG was investigated in one and two studies, respectively. Overall correlation was limited and ranged from 0.0 to 0.40 (total thrombus generation vs. fibrinogen; clotting time INTEM vs. activated partial thromboplastin time). CONCLUSIONS: Studies assessing the relationship between thromboelastometry or thromboelastography analyses and conventional parameters of hemostasis in healthy subjects remains scarce, and correlations are limited. Further research is needed to understand the physiology of thromboelastometry and thromboelastography parameters.

6.
Br J Haematol ; 175(4): 677-685, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27468696

RESUMEN

Although patient self-management (PSM) of oral anticoagulation with vitamin K antagonists is recommended for patients requiring long-term anticoagulation, important aspects are still unclear. Using data from a large international survey (n = 15 834; median age 72 years; 30·1% female), we studied predictors of poor anticoagulation control (percentage of International Normalized Ratio values within therapeutic range below 75%) and developed a simple prediction model. The following variables were identified as risk factors for poor anticoagulation control and included in the final model: higher intensity of therapeutic range (odds ratio [OR] on every level 1·9; 95% confidence interval [CI] 1·8-2·0), long intervals between measurements (>14 d; 1·5; 95% CI 1·3-1·7), female sex (OR 1·3; 95% CI 1·2-1·4), and management other than PSM (OR 1·4; 95% CI 1·2-1·6). At a threshold of 0·2 (at least one variable present), the model predicted poor anticoagulation control with a sensitivity of 85·3% (95% CI: 84·0, 86·4) and a specificity of 28·5% (27·6, 29·5). The area under the receiver operated characteristic curve was 0·65. Using the proposed prediction model, physicians will be able to identify patients with a low chance of performing well, considering additional training, regular follow-up, or adjustment of therapeutic ranges.


Asunto(s)
Anticoagulantes/administración & dosificación , Coagulación Sanguínea/efectos de los fármacos , Autocuidado , Vitamina K/antagonistas & inhibidores , Administración Oral , Anciano , Anciano de 80 o más Años , Pruebas de Coagulación Sanguínea , Femenino , Humanos , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Pronóstico , Curva ROC , Encuestas y Cuestionarios , Resultado del Tratamiento
7.
Blood Adv ; 8(11): 2825-2834, 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38588487

RESUMEN

ABSTRACT: New analytical techniques can assess hundreds of proteins simultaneously with high sensitivity, facilitating the observation of their complex interplay and role in disease mechanisms. We hypothesized that proteomic profiling targeting proteins involved in thrombus formation, inflammation, and the immune response would identify potentially new biomarkers for heparin-induced thrombocytopenia (HIT). Four existing panels of the Olink proximity extension assay covering 356 proteins involved in thrombus formation, inflammation, and immune response were applied to randomly selected patients with suspected HIT (confirmed HIT, n = 32; HIT ruled out, n = 38; and positive heparin/platelet factor 4 [H/PF4] antibodies, n = 28). The relative difference in protein concentration was analyzed using a linear regression model adjusted for sex and age. To confirm the test results, soluble P-selectin was determined using enzyme-linked immunosorbent assay (ELISA) in above mentioned patients and an additional second data set (n = 49). HIT was defined as a positive heparin-induced platelet activation assay (washed platelet assay). Among 98 patients of the primary data set, the median 4Ts score was 5 in patients with HIT, 4 in patients with positive H/PF4 antibodies, and 3 in patients without HIT. The median optical density of a polyspecific H/PF4 ELISA were 3.0, 0.9, and 0.3. Soluble P-selectin remained statistically significant after multiple test adjustments. The area under the receiver operating characteristic curve was 0.81 for Olink and 0.8 for ELISA. Future studies shall assess the diagnostic and prognostic value of soluble P-selectin in the management of HIT.


Asunto(s)
Biomarcadores , Heparina , Proteómica , Trombocitopenia , Humanos , Heparina/efectos adversos , Femenino , Proteómica/métodos , Masculino , Trombocitopenia/inducido químicamente , Trombocitopenia/diagnóstico , Trombocitopenia/sangre , Persona de Mediana Edad , Anciano , Selectina-P/sangre , Factor Plaquetario 4 , Adulto , Activación Plaquetaria
8.
JAMA Netw Open ; 7(3): e243786, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38530310

RESUMEN

Importance: Heparin-induced thrombocytopenia (HIT) is a life-threatening condition that requires urgent diagnostic clarification. However, knowledge of the diagnostic utility of the recommended diagnostic tests is limited in clinical practice. Objective: To evaluate the current diagnostic practice for managing the suspicion of HIT. Design, Setting, and Participants: This prospective diagnostic study was conducted from January 2018 to May 2021 among consecutive patients with suspected HIT from 11 study centers in Switzerland, Germany, and the United States. Detailed clinical data and laboratory information were recorded. Platelet factor 4/heparin antibodies were quantified using an automated chemiluminescent immunoassay (CLIA). A washed-platelet heparin-induced platelet activation (HIPA) test was used as a reference standard to define HIT. Exposures: Suspicion of HIT. Main Outcomes and Measures: The primary outcome was the diagnostic accuracy of the 4Ts score, the CLIA, and the recommended algorithm serially combining both tests. Results: Of 1448 patients included between 2018 and 2021, 1318 were available for the current analysis (median [IQR] age, 67 [57-75] years; 849 [64.6%] male). HIPA was positive in 111 patients (prevalence, 8.4%). The most frequent setting was intensive care unit (487 [37.0%]) or cardiovascular surgery (434 [33.0%]). The 4Ts score was low risk in 625 patients (46.8%). By 2 × 2 table, the numbers of patients with false-negative results were 10 (9.0%; 4Ts score), 5 (4.5%; CLIA), and 15 (13.5%; recommended diagnostic algorithm). The numbers of patients with false-positive results were 592 (49.0%; 4Ts score), 73 (6.0%; CLIA), and 50 (4.1%; recommended diagnostic algorithm), respectively. Conclusions and Relevance: In this diagnostic study of patients suspected of having HIT, when the recommended diagnostic algorithm was used in clinical practice, antibody testing was required in half the patients. A substantial number of patients were, however, still misclassified, which could lead to delayed diagnosis or overtreatment. Development of improved diagnostic algorithms for HIT diagnosis should be pursued.


Asunto(s)
Trombocitopenia , Humanos , Masculino , Anciano , Femenino , Estudios Prospectivos , Trombocitopenia/inducido químicamente , Trombocitopenia/diagnóstico , Heparina/efectos adversos , Algoritmos , Alemania
9.
Thromb J ; 11(1): 6, 2013 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-23496906

RESUMEN

BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.

10.
Ther Umsch ; 70(8): 443-8, 2013 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-23876750

RESUMEN

Coagulation assays are prone to pre-analytical problems and results may be influenced by varying clinical and pharmaceutical aspects. Particularly anticoagulants interact with coagulation testing in many ways. Thromboplastin time will be prolonged dose-dependently in patients taking vitamin K antagonists; moreover the new oral anticoagulants have been shown to have variable impact on the results of the thromboplastin time as well as on other coagulation tests, depending on the mechanism of action of these new drugs as well as on the mechanism of the coagulation test. When measuring anti-Xa activity it should be realised that all drugs with anti-Xa activity will influence the result, which means not only heparins but also the new anti-Xa inhibitors. Respective calibration curves are an indispensable condition to provide the clinician with valuable results. On the other hand this implies that the laboratory knows which anticoagulant is given to the patient. This is an example among others that clinical aspects are important to know for proper interpretation of the results of coagulation testing. Other examples are e. g. bleeding disorders, actual bleeding status or thromboembolic events. Several cases are discussed which exemplify possible pitfalls in the interpretation of coagulation testing.


Asunto(s)
Trastornos de la Coagulación Sanguínea/diagnóstico , Trastornos de la Coagulación Sanguínea/tratamiento farmacológico , Pruebas de Coagulación Sanguínea/métodos , Pruebas de Coagulación Sanguínea/normas , Guías como Asunto , Adulto , Anciano , Anticoagulantes , Trastornos de la Coagulación Sanguínea/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA