Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Cardiovasc Disord ; 24(1): 149, 2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38475690

RESUMEN

BACKGROUND: Tricuspid regurgitation (TR) is a prevalent disease that triggers systemic pathological changes including cardiac, respiratory, hepatic and digestive, hematopoietic, renal and skin issues. The burden of extra-cardiac manifestations has not been well described in TR patients and the clinical impact is unknown. METHODS: Patients with severe or more-than-severe TR during hospitalization, who did not have any previous cardiac procedures, hemodynamically significant congenital heart disease or concomitant severe aortic or mitral valve disease, were retrospectively analyzed. Pre-specified criteria and diagnosis of baseline characteristics were used to evaluate the presence of extra-cardiac manifestations secondary to TR after excluding comorbidities that may also lead to corresponding abnormalities. Extra-cardiac involvements encompass respiratory, hepatic and, digestive, renal, hematopoietic and dermatic system. Staging criteria are defined as no extra-cardiac system involvement in Stage 1, one in Stage 2, at least two extra-cardiac involvements in Stage 3 and any end-stage organ failure in Stage 4. A telephone follow-up was conducted to record the composite endpoint namely all-cause death or cardiac rehospitalization after the index hospitalization. RESULTS: A total of 258 patients were identified with a median age of 73 (interquartile range [IQR]: 62-83) years and 52.3% were female. Severe TR and more-than-severe TR patients accounted for 92.6% and 7.4% of the cohort. There were 20.5%, 27.5%, 37.6% and 14.3% of patients from Stage 1 to 4 respectively. The follow-up time was at a median of 251 (IQR: 183-324) days. TR Patients in Stage 3&4 were at an increased risk with borderline statistical significance to experience the composite endpoint compared to patients in Stage 1&2 (odds ratio [OR] 1.9, 95% confidence interval [CI] 1.0 to 3.7, P = 0.049). CONCLUSIONS: Approximately half of patients with at least severe TR presented with two or more extra-cardiac systemic manifestations, which may incur a 1.9-fold higher risk of all-cause death or cardiac rehospitalization than TR patients with one or less extra-cardiac involvement.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Insuficiencia de la Válvula Tricúspide/etiología , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Medición de Riesgo , Hemodinámica
2.
BMC Cardiovasc Disord ; 23(1): 354, 2023 07 17.
Artículo en Inglés | MEDLINE | ID: mdl-37460957

RESUMEN

BACKGROUND: We aim to determine predictors of inadequate left ventricular mass index (LVMi) regression at mid-term after transcatheter aortic valve replacement (TAVR), including the potential role of epicardial adipose tissue (EAT). METHODS: We retrospectively reviewed patients with both echocardiographic assessments and multi-slice computed tomography (MSCT) obtained one year after TAVR. The change of LVMi, the volume and the average CT attenuation of EAT from baseline to one-year follow-up was calculated. Patients were divided into two groups by the percentage change of LVMi at a cut-off of 15%. RESULTS: A total of 152 patients were included with a median age of 74 years (interquartile range [IQR] 69-78 years) and 56.6% being male. LVMi decreased (P < 0.0001) while EAT volume increased and the average CT attenuation decreased (both P < 0.0001) at one year. Baseline atrial fibrillation (P = 0.042), mitral regurgitation ≥ mild (P = 0.006), aortic regurgitation (AR) > mild (P = 0.001) and the change in the average CT attenuation of EAT (P = 0.026) were different between the decrease of LVMi ≥ 15% and < 15%. AR > mild at baseline was the only statistically significant predictor of a decrease of LVMi < 15% at one year (OR 0.33, 95% CI: 0.13 to 0.84, P = 0.021) in multivariate regression. CONCLUSIONS: Concomitant more-than-mild AR might predict better left ventricular reverse remodeling regression after TAVR.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estudios Retrospectivos , Función Ventricular Izquierda , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad , Remodelación Ventricular
3.
Eur Radiol ; 31(8): 6220-6229, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34156556

RESUMEN

OBJECTIVES: We sought to identify the impact of transcatheter aortic valve implantation (TAVI) on changes of fractional flow reserve computed tomography (FFRCT) values and the associated clinical impact. METHODS: A retrospective analysis was done with CT obtained pre-TAVI, prior to hospital discharge and at 1-year follow-up, which provided imaging sources for the calculation of FFRCT values based on an online platform. RESULTS: A total of 190 patients were enrolled. Patients with pre-procedural FFRCT value > 0.80 (i.e., negative) and ≤ 0.80 (i.e., positive) demonstrated a significantly opposite change in the value after TAVI (0.8798 vs. 0.8718, p < 0.001 and 0.7634 vs. 0.8222, p < 0.001, respectively). The history of coronary artery disease (CAD) was identified as an independent predictor for FFRCT changing from negative to positive after TAVI (odds ratio [OR] 2.927, 95% confidence interval [CI] 1.130-7.587, p = 0.027), with lesions more severely stenosed (OR 1.039, 95% CI 1.003-1.076, p = 0.034) and in left anterior descending coronary artery (LAD) (OR 3.939, 95% CI 1.060-14.637, p = 0.041) being prone to change. CONCLUSIONS: TAVI directly brings improvement in FFRCT values in patients with compromised coronary flow. Patients with a history of CAD, especially with lesions more severely stenosed and in LAD, were under risk of FFRCT changing from negative to positive after TAVI. KEY POINTS: •The effect of TAVI on coronary hemodynamics might be influenced by different ischemic severity and coronary territories reflected by FFRCT values. •As different FFRCT variations did not impact outcomes of TAVI patients, AS, but not coronary issues, may be the primary problem to affect, which needs further validation.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Reemplazo de la Válvula Aórtica Transcatéter , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Hemodinámica , Humanos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X
4.
BMC Cardiovasc Disord ; 21(1): 590, 2021 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-34876008

RESUMEN

BACKGROUND: Optimal projection is essential for valve deployment during transcatheter aortic valve implantation (TAVI). The purpose of this study was to propose an approach to predict optimal projection in TAVI candidates with different aortic valve anatomies. METHODS: 331 patients undergoing self-expanding TAVI were included and the so-called non-coronary cusp (NCC)-parallel technique was utilized, which generated the predicted projection by connecting NCC commissures on the transverse plane on the pre-procedural computed tomography images. RESULTS: 37.8% of the study cohort were bicuspid aortic valve (BAV) patients. Around 80% of both NCC-parallel views and final views were in the right anterior oblique (RAO) and caudal (CAU) quadrant. There was less than 5° change required from the NCC-parallel view to the final implanted view in 79% of tricuspid aortic valve (TAV) patients but only in 27% (13/48) of type 0 BAV patients with coronary arteries originated from the different cusps. After excluding the above mentioned BAV patients, 62.3% (48/77) of BAV patients needed less than 5° change to achieve optimal projection and only in 8 patients, the angular change was larger than 10° in either left/right anterior oblique or cranial/caudal direction. CONCLUSIONS: The NCC-parallel technique provides reliable prediction for optimal projection in self-expanding TAVI in all TAV and most BAV patients, with a vast majority of views in the RAO and CAU quadrant.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Tomografía Computarizada Multidetector , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Puntos Anatómicos de Referencia , Válvula Aórtica/anomalías , Toma de Decisiones Clínicas , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis
5.
Herz ; 46(Suppl 2): 166-172, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32880663

RESUMEN

BACKGROUND: Some patients referred for transcatheter aortic valve replacement (TAVR) have excessively large annuli (ELA) without device options according to current sizing charts. This retrospective study aims to summarize the presentation and outcomes of ELA patients receiving first-generation self-expanding valves. METHODS: The TAVR database was reviewed in search for cases of self-expanding valves. Patients who had annuli exceeding the perimeter limit on the device sizing chart were referred to as the ELA group. Patients who had annuli within the range covered by the two largest sizes and received the corresponding valve size served as the control group (CG). Baseline, procedures, outcomes, and imaging characteristics on multislice computed tomography (MSCT), such as native anatomy and postimplant stent geometry, were compared. RESULTS: A total of 28 patients were included in the ELA group and 82 in the CG. The patients in the ELA group were younger than those in the CG (72.5 ± 6.2 vs. 75.4 ± 5.8 years, P = 0.03). The median intended perimeter oversizing in relation to the annulus in the ELA group was much smaller than in the CG (-0.4 [-4.6, 4.1] % vs. 16.1 [11.7, 20.8] %, P < 0.01). The calcium burden in the aortic root was around 1.3-fold greater in the ELA group than the CG (756.0 [534.5, 1670.9] vs. 582.1 [310.3, 870.9] mm3, P = 0.01). The need for second valve implantation was higher in ELA (21.4% vs. 12.2%, P = 0.23) but no valve embolization was encountered. The 1­year follow-up was comparable, including >mild paravalvular leak. CONCLUSION: Under cautious patient selection using MSCT, TAVR with self-expanding valves in patients with ELA appears feasible. Supra-annular structures likely provide the extra anchoring.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Tomografía Computarizada Multidetector , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 96(7): 1491-1497, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32400115

RESUMEN

OBJECTIVE: We hypothesize that different degree of pre-existing aortic regurgitation (AR) may affect the presence of hypo-attenuated leaflet thickening (HALT) after transcatheter aortic valve replacement (TAVR). BACKGROUND: The mechanism of the presence of HALT post-TAVR is not fully understood. METHODS: We retrospectively evaluated the post-procedural multi-slice computed tomography (MSCT) before discharge for evidence of HALT. Patients were grouped according to the degree of pre-existing AR. Baseline, native anatomy and procedure details were compared, then multivariate regression was performed. RESULTS: MSCT analyzed was performed at a median of 6 days post-TAVR in 179 patients. HALT was detected in 10.6% of patients. After adjusting for variables that were significantly different between groups, pre-existing ≥ moderate AR was protective to the risk of HALT (OR 0.15, 95% CI 0.03-0.84, p = .03). Stratifying for factors that might explain the impact of pre-existing AR on HALT, patients with a small Sinus of Valsalva, non-eccentric remodeling and receiving a large bioprosthesis experienced a sevenfold higher risk for HALT (OR 7.16, 95% CI 2.05-25.08, p = .002). CONCLUSIONS: Patients underwent TAVR with pre-existing ≥ moderate AR appeared to experience a lower incidence of early HALT compared to those patients with less than moderate AR, which may be explained by a larger Sinus of Valsalva and a higher proportion of LV eccentric remodeling.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Masculino , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda , Remodelación Ventricular
7.
Catheter Cardiovasc Interv ; 95 Suppl 1: 616-623, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31943783

RESUMEN

OBJECTIVES: We evaluated the safety and usefulness of preparatory anatomical reshaping with a geometric hourglass-shaped balloon to optimize transcatheter aortic valve replacement (TAVR) outcomes in bicuspid aortic valve (BAV) stenosis. BACKGROUND: TAVR has been increasingly performed for BAV stenosis; however, technical challenges remain. Procedural results are suboptimal given unfavorable valvular anatomies. METHODS: Eligible patients with BAV stenosis were enrolled to undergo aortic valve predilatation with the hourglass-shaped TAV8 balloon before TAVR using the self-expandable Venus A-Valve. Procedural details and outcomes were compared to a sequential group of patients with BAV who underwent TAVR with the same device following preparatory dilatation using a cylindrical balloon. RESULTS: A total of 22 patients were enrolled in the TAV8 group and 53 were included in the control group. Valve downsizing was less common in the TAV8 group (36.4 vs. 67.9%; p = .012). Stable valve release and optimal implant depth were consistently achieved in the TAV8 group with no requirement for a second valve (0 vs. 17.0%; p = .039) and with higher device success rates (100.0 vs 77.4%; p = .014). Residual aortic regurgitation graded as ≥mild was less common in the TAV8 group (13.6 vs 45.3%; p = .009). Mortality was similar (0 vs. 3.8%; p = 1); no major/disabling stroke or conversion to open-heart surgery was seen in either group within 30 days. CONCLUSIONS: Compared with standard cylindrical balloon valvuloplasty, preparatory reshaping with the hourglass-shaped balloon before self-expandable TAVR in BAV was associated with significantly better procedural results and may encourage more promising outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/instrumentación , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/mortalidad , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/mortalidad , Enfermedad de la Válvula Aórtica Bicúspide/fisiopatología , Femenino , Humanos , Masculino , Proyectos Piloto , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
8.
BMC Cardiovasc Disord ; 20(1): 229, 2020 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-32423380

RESUMEN

BACKGROUND: To explore why bicuspid aortic stenosis has certain clinical differences from the tricuspid morphology, we evaluated the metabolomics profile involved in bicuspid aortic valve (BAV) aortic stenosis prior to and after transcatheter aortic valve replacement (TAVR) in comparison with tricuspid aortic valve (TAV). METHODS: In this TAVR cohort with prospectively collected data, blood samples were obtained before TAVR valve deployment and at the 7th day after TAVR, which were then sent for liquid and gas chromatography-mass spectrometry detection. Besides comparisons between BAV and TAV, BAV patients were also divided in subgroups according to baseline hemodynamics (i.e. maximal transaortic velocity, Vmax) and post-procedural reverse left ventricular (LV) remodeling (i.e. the change in LV mass index from baseline, ∆LVMI) for further analysis. Metabolic differences between groups were identified by integrating univariate test, multivariate analysis and weighted correlation network analysis algorithm. RESULTS: A total of 57 patients were enrolled including 33 BAV patients. The BAV group showed lower arginine and proline metabolism both before and post TAVR than TAV represented by decreased expression of L-Glutamine. In BAV subgroup analysis, patients with baseline Vmax > 5 m/s (n = 11) or the 4th quartile of change in ∆LVMI at one-year follow-up (i.e. poorly-recovered LV, n = 8) showed elevated arachidonic acid metabolism compared with Vmax < 4.5 m/s (n = 12) or the 1st quartile of ∆LVMI (i.e. well-recovered LV, n = 8) respectively. CONCLUSIONS: Difference in arginine and proline metabolism was identified between BAV and TAV in TAVR recipients. Elevated arachidonic acid metabolism may reflect more severe baseline hemodynamics and worse LV reserve remodeling after TAVR in BAV.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Metabolismo Energético , Enfermedades de las Válvulas Cardíacas/cirugía , Metabolómica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/fisiopatología , Ácido Araquidónico/sangre , Arginina/sangre , Enfermedad de la Válvula Aórtica Bicúspide , Biomarcadores/sangre , Femenino , Enfermedades de las Válvulas Cardíacas/sangre , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/fisiopatología , Hemodinámica , Humanos , Masculino , Prolina/sangre , Estudios Prospectivos , Recuperación de la Función , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda , Remodelación Ventricular
9.
J Interv Cardiol ; 2019: 7348964, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31777470

RESUMEN

OBJECTIVES: We aimed to assess the procedural and clinical results of transcatheter aortic valve replacement (TAVR) for nonraphe bicuspid aortic stenosis (AS) with coronary vs mixed cusp fusion. BACKGROUND: It remains unclear whether cusp fusion morphology affects TAVR outcomes in patients with nonraphe bicuspid AS. METHODS: This retrospective study enrolled consecutive patients with severe symptomatic AS and type-0 bicuspid aortic valve, who underwent TAVR at our institution between 2012 and 2017. TAVR outcomes were defined based on the Valve Academic Research Consortium-2 recommendations. RESULTS: Compared to patients with mixed cusp fusion (44/71), those with coronary cusp fusion (27/71) had a larger ellipticity index for the aortic annulus (21.9% ± 9.0% vs 15.6% ± 9.3%, p=0.007) and increased left ventricular outflow tract obstruction (31.1% ± 9.4% vs 26.9% ± 7.5%, p=0.04) but comparable rates of second valve implantation (15.9% vs 14.8%), mild paravalvular leakage (PVL, 38.5% vs 30.2%), permanent pacemaker implantation (PPM, 25.9% vs 15.9%), and 30-day mortality (7.4% vs 6.8%). Use of a first-generation transcatheter heart valve was associated with higher risk for mild PVL (odds ratio (OR) = 4.37; 95% confidence interval (95% CI) = 1.14-16.75; p=0.03) but not PPM (OR = 0.77; 95% CI = 0.22-2.62; p=0.67), whereas a larger oversizing ratio tended to be associated with a higher PPM rate (OR = 1.49; 95% CI = 0.46-4.86; p=0.51) but lower incidence of mild PVL (OR = 0.51; 95% CI = 0.19-1.35; p=0.17). CONCLUSIONS: In AS patients with type-0 bicuspid valves, cusp fusion morphology does not affect the procedural or clinical results of TAVR. Use of second-generation transcatheter heart valves may provide more favorable results in such patients. This trial is registered with NCT01683474.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Humanos , Masculino , Tomografía Computarizada Multidetector , Diseño de Prótesis
10.
J Interv Cardiol ; 31(6): 878-884, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30079561

RESUMEN

BACKGROUND: Studies of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) specifically for bicuspid aortic valve (BAV) patients are lacking. We aim to delineate possible aspects that might affect the incidence of PPI in a retrospective cohort of BAV patients treated with early-generation self-expanding devices. METHODS: A total of 80 patients with bicuspid morphology who successfully underwent TAVR by self-expanding devices without prior PPI were included. Baseline clinical, echocardiographic, and angiographic characteristics, procedural and post-procedural details were collected. RESULTS: The incidence of PPI after early-generation self-expanding valves in this BAV cohort was 26.3%. Baseline characteristics were comparable between patients requiring PPI post-TAVR or not. Perimeter oversizing greater than 20% significantly increased the risk of PPI compared with an oversizing of 10-20% (OR 5.08 [1.22, 21.07], P = 0.03). The proportion of patients with a depth of implantation greater than 6 mm was significantly higher in those who required PPI (82.4% vs 54.3%, P = 0.04). When testing the impact of depth of implantation >6 mm and oversizing in different morphologies, only in type 1 bicuspid patients and by oversizing>20% increased the risk of PPI (OR 12.00 [1.25, 115.36], P = 0.03) compared with an oversizing of 10-20%. CONCLUSIONS: Excessive perimeter oversizing in relation to aortic annulus and depth of implantation greater than 6 mm should be avoided to improve PPI post-TAVR for BAV patients receiving self-expanding devices, especially for type 1 BAV.


Asunto(s)
Válvula Aórtica/anomalías , Arritmias Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Marcapaso Artificial/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Arritmias Cardíacas/etiología , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Humanos , Incidencia , Masculino , Tomografía Computarizada Multidetector , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
11.
J Thromb Thrombolysis ; 45(3): 463-465, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29478129

RESUMEN

The imaging finding of hypo-attenuated leaflet thickening (HALT) on bioprosthesis after transcatheter aortic valve replacement (TAVR) has been reported. The underlying mechanism is not clear, but leaflet thrombosis is speculated to be the cause. Heterogeneous antiplatelet responses may play a role in the process. This is a prospective, single-center pilot study in patients who received successful TAVR from June 2012 to November 2016. HALT on post-procedural multi-detector computed tomography. We thoroughly genotyped 34 SNPs and 8 SNPs that have been reported for clopidogrel and aspirin resistance. A total of 148 patients were enrolled. There were 15 patients demonstrating signs of HALT. Patients with HALT had a higher rate of atrial fibrillation (AF) pre-TAVR (33.3 vs. 7.5%, P = 0.01). We found that rs4244285 G>A polymorphism of the CYP2C19 gene was associated with the risk of HALT in the overdominant model (OR 4.00 [1.15-13.97], P = 0.02 for GA vs. GG+AA) adjusted by sex and the presence of pre-TAVR AF. Antiplatelet drug resistance is a reasonable possibility involved in HALT. Potential directions were suggested in polymorphisms of the CYP2C19 gene.


Asunto(s)
Inhibidores de Agregación Plaquetaria/uso terapéutico , Polimorfismo de Nucleótido Simple , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Aspirina/farmacología , Aspirina/uso terapéutico , Clopidogrel , Citocromo P-450 CYP2C19/genética , Resistencia a Medicamentos/genética , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Masculino , Proyectos Piloto , Estudios Prospectivos , Ticlopidina/análogos & derivados , Ticlopidina/farmacología , Ticlopidina/uso terapéutico
12.
Catheter Cardiovasc Interv ; 87 Suppl 1: 570-8, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26856312

RESUMEN

OBJECTIVE: The present study was performed to investigate the relationship between chronic obstructive pulmonary disease (COPD) and transcatheter aortic valve implantation (TAVI). BACKGROUND: Controversies regarding the relationship between COPD and TAVI have intensified. METHODS: A literature review of the PubMed online database was performed, and articles published between January 1, 2002 and March 20, 2015 were analyzed. Random-effect and fixed-effect models were used, depending on the between-study heterogeneity. RESULTS: A total of 28 studies, involving 51,530 patients, were identified in our review. The burden of COPD ranged from 12.5% to 43.4%, and COPD negatively impacted both short-term and long-term all-cause survival (30 days: odds ratio [OR], 1.43, 95% CI, 1.14-1.79; >2 years: hazard ratio [HR], 1.34, 95% CI, 1.12-1.61). COPD was also associated with increased short-term and mid-term cardiac-cause mortality (30 days: OR, 1.29, 95% CI, 1.02-1.64; 1 year: HR: 1.09, 1.02-1.17). Moreover, COPD (OR, 1.97, 95% CI, 1.29-3.0) predicted post-TAVI acute kidney disease. Importantly, chronic kidney disease (CKD) (HR, 1.2, 95% CI, 1.1-1.32) and the distance of the 6 minute walk test (6MWT) (HR, 1.16, 1.06-1.27) predicted TAVI futility in patients with COPD. CONCLUSION: COPD is common among patients undergoing TAVI, and COPD impacts both short- and long-term survival. COPD patients, who had a lower BMI, shorter distance of 6MWT and CKD, were at higher risk for TAVI futility.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Lesión Renal Aguda/epidemiología , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Índice de Masa Corporal , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Distribución de Chi-Cuadrado , Comorbilidad , Prueba de Esfuerzo , Tolerancia al Ejercicio , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Modelos Logísticos , Pulmón/fisiopatología , Masculino , Análisis Multivariante , Oportunidad Relativa , Prevalencia , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/mortalidad , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Insuficiencia Renal Crónica/epidemiología , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Caminata
14.
BMJ Open ; 13(12): e078061, 2023 12 18.
Artículo en Inglés | MEDLINE | ID: mdl-38110378

RESUMEN

INTRODUCTION: Decisions regarding the optimal timing of intervention for asymptomatic aortic stenosis (AS) are controversial. The study aims to identify potential risk factors for asymptomatic patients with severe AS that are associated with worse prognosis and to evaluate the benefits of early interventions for asymptomatic patients presenting with one or more additional risk factors. METHODS AND ANALYSIS: This is a non-interventional, prospective, open-label, multicentre registry study across China. A total of 1000 patients will be enrolled and categorised as symptomatic or asymptomatic. The primary endpoint is the occurrence of all-cause mortality, stroke, acute myocardial infarction and heart failure-related hospitalisation at 1-year follow-up. In asymptomatic severe AS patients presenting with one or more risk factors, the occurrence rate of the primary endpoint between those who undergo transcatheter aortic valve replacement (TAVR) and those who do not will be compared. We will also compare the occurrence rate of the primary endpoint for asymptomatic severe AS patients with additional risk factors who undergo TAVR with those presenting with symptoms. This study is believed to provide additional evidence to help clinicians identify and refer severe AS patients who are asymptomatic but present with additional risk factors for early intervention of TAVR. ETHICS AND DISSEMINATION: The study protocol has been approved by the local ethics committee of each participating site: West China Hospital, Sichuan University; Sir Run Run Shaw Hospital, Zhejiang University School of Medicine; Second Hospital of Hebei Medical University; Tianjin Chest Hospital; and First Affiliated Hospital of Nanchang University. All participants will provide written informed consent. Study results will be published through academic conferences and peer-reviewed journals. TRIAL REGISTRATION: This study was registered at the Chinese Clinical Trial Registry (https:// www.chictr.org.cn), with the registration number ChiCTR2200064853.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estudios Multicéntricos como Asunto , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
Circ Cardiovasc Interv ; 16(12): e013083, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37846559

RESUMEN

BACKGROUND: Data concerning the outcomes of transcatheter aortic valve replacement in type 0 bicuspid aortic stenosis (AS) are scarce. The study aims to compare the outcomes of transcatheter aortic valve replacement for AS in patients with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy. METHODS: We enrolled consecutive patients undergoing transcatheter aortic valve replacement for severe AS between 2012 and 2022 in this single-center retrospective cohort study. The primary outcome was mortality, while secondary outcomes included in-hospital complications such as stroke and pacemaker implantation and transcatheter heart valve hemodynamic performance. RESULTS: The number of patients with AS with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy was 328, 302, and 642, respectively. Self-expanding transcatheter heart valves were used in the majority of patients (n=1160; 91.4%). In the matched population, differences in mortality (30 days: 4.2% versus 1.7% versus 1.7%, Poverall=0.522; 1 year: 10% versus 2.3% versus 6.2%, Poverall=0.099) and all stroke (30 days: 1.0% versus 0.9% versus 0.0%, Poverall=0.765; 1 year: 1.4% versus 1.6% versus 1.3%, Poverall=NS) were nonsignificant, and the incidence of overall in-hospital complications was comparable among groups. Ascending aortic diameter was the single predictor of 1-year mortality in type 0 bicuspid patients (hazard ratio, 1.59 [95% CI, 1.03-2.44]; P=0.035). The proportion of patients with a mean residual gradient ≥20 mm Hg was the highest in those with type 0 bicuspid anatomy, although the need for permanent pacemaker implantation was the lowest in this group. CONCLUSIONS: Major clinical outcomes of transcatheter aortic valve replacement for AS in patients with type 0 bicuspid, type 1 bicuspid, and tricuspid aortic valve anatomy are equivalent at short- and mid-term follow-up. These observations merit further exploration in prospective international registries and randomized controlled trials.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Prospectivos , Estudios Retrospectivos , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía
16.
Nat Rev Cardiol ; 20(1): 52-67, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35726019

RESUMEN

Indications for transcatheter aortic valve implantation (TAVI) have expanded in many countries to include patients with aortic stenosis who are at low surgical risk, and a similar expansion to this cohort is anticipated elsewhere in the world, together with an increase in the proportion of patients with bicuspid aortic valve (BAV) morphology as the age of the patients being treated decreases. To date, patients with BAV have been excluded from major randomized trials of TAVI owing to anatomical considerations. As a consequence, BAV has been a relative contraindication to the use of TAVI in international guidelines. Although clinical experience and observational data are accumulating, BAV presents numerous anatomical challenges for successful TAVI, despite advances in device design. Furthermore, in those with BAV, substantial geographical variation exists in patient characteristics, clinical approach and procedural strategy. Therefore, in this Roadmap article, we summarize the existing evidence and provide consensus recommendations from an international group of experts on the application of TAVI in patients with BAV in advance of the anticipated growth in the use of this procedure in this challenging cohort of patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/etiología , Válvula Mitral , Resultado del Tratamiento , Enfermedad de la Válvula Aórtica Bicúspide/etiología , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estándares de Referencia
17.
JACC Cardiovasc Interv ; 15(2): 123-134, 2022 01 24.
Artículo en Inglés | MEDLINE | ID: mdl-35057982

RESUMEN

OBJECTIVES: The aim of this study was to assess cusp symmetry and coronary ostial eccentricity and its impact on coronary access following transcatheter aortic valve replacement (TAVR) using a patient-specific commissural alignment implantation technique. BACKGROUND: TAVR implantation techniques to obtain neocommissural alignment have been introduced. The impact of cusp symmetry and coronary ostial eccentricity on coronary access after TAVR remains unknown. METHODS: Cardiac computed tomographic scans from 200 tricuspid aortic valves (TAVs) and 200 type 1 bicuspid aortic valves (BAVs) were studied. Cusp symmetry and coronary ostial eccentricity were assessed. In addition, the right coronary cusp/left coronary cusp and right coronary artery (RCA)/left coronary artery (LCA) ostia overlap views were calculated and compared. RESULTS: Severe cusp asymmetry (>135°) was more frequent in BAVs (52.5%) than in TAVs (2.5%) (P < 0.001), with the noncoronary cusp being the most common dominant cusp. The RCA ostium was found to be more often eccentric (>20°) than the LCA ostium (28% vs 6%, respectively; P < 0.001). Considering the right/left cusp overlap view, there was <20° deviation between the right coronary cusp-left coronary cusp centered line and the RCA-LCA centered line in 95% of all patients (TAV, 97%; BAV, 93%). The right/left cusp and coronary ostia overlap view differed by <10° and <20° fluoroscopic angulation in 75% and 98% of all cases, respectively. CONCLUSIONS: Using the right/left cusp overlap view to obtain commissural alignment in TAVR is also an effective approach to implant one of the transcatheter heart valve commissures in the near center between both coronary ostia in most TAVs and type 1 BAVs. Preprocedural CT assessment remains crucial to assess cusp symmetry and coronary ostial eccentricity.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Válvula Tricúspide/cirugía
18.
Front Cardiovasc Med ; 9: 794850, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35369357

RESUMEN

Objective: We sought to conduct a systematic review and meta-analysis of clinical adverse events in patients undergoing transcatheter aortic valve replacement (TAVR) with bicuspid aortic valve (BAV) vs. tricuspid aortic valve (TAV) anatomy and the efficacy of balloon-expandable (BE) vs. self-expanding (SE) valves in the BAV population. Comparisons aforementioned will be made stratified into early- and new-generation devices. Differences of prosthetic geometry on CT between patients with BAV and TAV were presented. In addition, BAV morphological presentations in included studies were summarized. Method: Observational studies and a randomized controlled trial of patients with BAV undergoing TAVR were included according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. Results: A total of 43 studies were included in the final analysis. In patients undergoing TAVR, type 1 BAV was the most common phenotype and type 2 BAV accounted for the least. Significant higher risks of conversion to surgical aortic valve replacement (SAVR), the need of a second valve, a moderate or severe paravalvular leakage (PVL), device failure, acute kidney injury (AKI), and stroke were observed in patients with BAV than in patients with TAV during hospitalization. BAV had a higher risk of new permanent pacemaker implantation (PPI) both at hospitalization and a 30-day follow-up. Risk of 1-year mortality was significantly lower in patients with BAV than that with TAV [odds ratio (OR) = 0.85, 95% CI 0.75-0.97, p = 0.01]. BE transcatheter heart valves (THVs) had higher risks of annular rupture but a lower risk of the need of a second valve and a new PPI than SE THVs. Moreover, BE THV was less expanded and more elliptical in BAV than in TAV. In general, the rates of clinical adverse events were lower in new-generation THVs than in early-generation THVs in both BAV and TAV. Conclusions: Despite higher risks of conversion to SAVR, the need of a second valve, moderate or severe PVL, device failure, AKI, stroke, and new PPI, TAVR seems to be a viable option for selected patients with severe bicuspid aortic stenosis (AS), which demonstrated a potential benefit of 1-year survival, especially among lower surgical risk population using new-generation devices. Larger randomized studies are needed to guide patient selection and verified the durable performance of THVs in the BAV population.

19.
JACC Cardiovasc Interv ; 15(16): 1652-1660, 2022 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-35981839

RESUMEN

BACKGROUND: It is unknown whether the sex difference whereby female transcatheter aortic valve replacement (TAVR) candidates had a lower risk profile, a higher incidence of in-hospital complications, but more favorable short- and long-term survival observed in tricuspid cohorts undergoing TAVR would persist in patients with bicuspid aortic valves (BAVs). OBJECTIVES: The aim of this study was to reexamine the impact of sex on outcomes following TAVR in patients with BAVs. METHODS: In this single-center study, patients with BAVs undergoing TAVR for severe aortic stenosis from 2012 to 2021 were retrospectively included. Baseline characteristics, aortic root anatomy, and in-hospital and 1-year valve hemodynamic status and survival were compared between sexes. RESULTS: A total of 510 patients with BAVs were included. At baseline, women presented with fewer comorbidities. Men had a greater proportion of Sievers type 1 BAV, higher calcium volumes (549.2 ± 408.4 mm3 vs 920.8 ± 654.3 mm3; P < 0.001), and larger aortic root structures. Women experienced more vascular complications (12.9% vs 4.9%; P = 0.002) and bleeding (11.1% vs 5.3%; P = 0.019) and higher residual gradients (16.9 ± 7.7 mm Hg vs 13.2 ± 6.4 mm Hg; P < 0.001), while men were more likely to undergo second valve implantations during index TAVR (6.3% vs 15.9%; P = 0.001). Death at 1 year was not significantly different between sexes (HR: 1.15; 95% CI: 0.56-2.35; P = 0.70). Bleeding (adjusted HR: 4.62; 95% CI: 1.51-14.12; P = 0.007) was the single independent predictor of 1-year death for women. CONCLUSIONS: In patients with BAVs undergoing TAVR, women presented with fewer comorbidities, while men had a greater proportion of type 1 BAV, more calcification, and larger aortic roots. In-hospital outcomes favored men, with fewer complications except for the need for second valve implantation, but 1-year survival was comparable between sexes.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Estudios Retrospectivos , Caracteres Sexuales , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
20.
J Int Med Res ; 49(6): 3000605211021732, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34111997

RESUMEN

Coronary artery fistula is an abnormal direct connection between the coronary artery and any of the four chambers of the heart or great vessels. A fistula from the left circumflex coronary artery to the coronary sinus is a relatively rare situation. We report a case of 12-month-old infant with coronary artery fistula from the left circumflex coronary artery to the coronary sinus that was identified incidentally. The N-terminal pro-brain natriuretic peptide level was elevated. Additionally, the proximal segment of the left circumflex coronary artery was dilated. On the basis of these findings, percutaneous closure of the fistula was performed with a vascular plug. This procedure achieved no residual flow and good hemodynamics were observed during follow-up.


Asunto(s)
Seno Coronario , Anomalías de los Vasos Coronarios , Fístula , Cateterismo Cardíaco , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/cirugía , Fístula/diagnóstico por imagen , Fístula/cirugía , Humanos , Lactante
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA