RESUMEN
Polysaccharides are widely used in biomedicine because of their unique biological activity, low costs, and easy-to-obtain. In this paper, Bletilla striata polysaccharide (BSP) was integrated into waterborne polyurethane (WPU) to prepare a series of WPU-BSP (WPUB) hydrogels. The hydrogels showed good compressive strength, water absorption and retention ability, which are favorable for wound healing. Among them, the WPUB4 gel has the best comprehensive performances, including a compressive strength of 1.07 MPa, a swelling rate of 16.3, a reasonable WVRT of 2013 g/m2/day, and a long water retention time. About the in vitro biocompatibility, moreover, the WPUB4 hydrogel has a low hemolysis rate of 2.47%, a hydroxyl radical clearance rate of 35.5%, and little cytotoxicity with cell viability of 101.4%. Most importantly, the WPUB hydrogel dressings showed excellent ability in promoting wound healing. Compared to the conventional gauze, the wound surface area of mice treated with WPUB hydrogel was significantly reduced on day 3 after surgery and the wounds were healed on day 7. The new skin had a thicker epidermis and more capillaries. The WPUB hydrogels integrating BSP are promising to function as wound dressings.
Asunto(s)
Hidrogeles , Orchidaceae , Animales , Ratones , Poliuretanos , Polisacáridos , Vendajes , AguaRESUMEN
Osteoporotic vertebral fracture (OVF) is a risk factor for morbidity and mortality in elderly population, and accurate diagnosis is important for improving treatment outcomes. OVF diagnosis suffers from high misdiagnosis and underdiagnosis rates, as well as high workload. Deep learning methods applied to plain radiographs, a simple, fast, and inexpensive examination, might solve this problem. We developed and validated a deep-learning-based vertebral fracture diagnostic system using area loss ratio, which assisted a multitasking network to perform skeletal position detection and segmentation and identify and grade vertebral fractures. As the training set and internal validation set, we used 11,397 plain radiographs from six community centers in Shanghai. For the external validation set, 1276 participants were recruited from the outpatient clinic of the Shanghai Sixth People's Hospital (1276 plain radiographs). Radiologists performed all X-ray images and used the Genant semiquantitative tool for fracture diagnosis and grading as the ground truth data. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were used to evaluate diagnostic performance. The AI_OVF_SH system demonstrated high accuracy and computational speed in skeletal position detection and segmentation. In the internal validation set, the accuracy, sensitivity, and specificity with the AI_OVF_SH model were 97.41%, 84.08%, and 97.25%, respectively, for all fractures. The sensitivity and specificity for moderate fractures were 88.55% and 99.74%, respectively, and for severe fractures, they were 92.30% and 99.92%. In the external validation set, the accuracy, sensitivity, and specificity for all fractures were 96.85%, 83.35%, and 94.70%, respectively. For moderate fractures, the sensitivity and specificity were 85.61% and 99.85%, respectively, and 93.46% and 99.92% for severe fractures. Therefore, the AI_OVF_SH system is an efficient tool to assist radiologists and clinicians to improve the diagnosing of vertebral fractures. © 2023 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).
Asunto(s)
Fracturas Osteoporóticas , Fracturas de la Columna Vertebral , Anciano , Humanos , Fracturas de la Columna Vertebral/etiología , Inteligencia Artificial , China , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/complicaciones , Columna VertebralRESUMEN
In degenerative disc disease, an injectable hydrogel can fill a degenerate area completely, reduce the risk of implant migration and subsequent loss of height of the intervertebral disc, and minimise surgical defects. Here, we propose a method of preparing an injectable silk fibroin/polyurethane (SF/PU) composite hydrogel by chemical cross-linking under physiological conditions. Mechanical testing was used to determine the mechanical strength of the hydrogel. The impact of hydrogel height on the biomechanical properties was discussed to estimate the working capacity of the hydrogel for further clinical application. Rheological properties were also examined to assess the practical ability of the hydrogel for clinical application. Hydrogel injection and cell assessment is also of interest for clinical application. An SF/PU composite hydrogel can be injected through a small incision. A cell proliferation assay using bone marrow stromal cells showed positive cell viability and increased proliferation over a seven-day period in culture. Importantly, the hydrogel can be monitored in real-time using X-ray fluoroscopy during and after surgery according to the results of X-ray fluoroscopy examination, and shows good visibility based on X-ray assays. In particular, the hydrogel offers the clinically important advantage of visibility in CT and T2-weighted magnetic resonance imaging. Based on the results of the current study, the SF/AU composite hydrogel may offer several advantages for future application in nucleus pulposus replacement.
Asunto(s)
Fibroínas/química , Hidrogeles , Disco Intervertebral , Poliuretanos/química , Seda/química , Microscopía Electrónica de Rastreo , ReologíaRESUMEN
In spinal degenerative disease, an injectable liquid hydrogel can fill in defect entirely, lessen the danger of implant relocation and following loss of disc height, minimizing the operative trauma. Here, we propose an injectable in-situ chemically cross-linked hydrogel by a two-component reaction of liquid silk fibroin with liquid polyurethane at physiological temperature conditions. Confined compression tests and fatigue tests were reported to assess physical properties of the hydrogel. Impact of different diameter on the biomechanical behaviours was tested to evaluate the clinical potentiality of the hydrogel for replacing nucleus pulposus. Degradation behaviours in different solutions and animal experiments were also investigated to examine the tissue biocompatibility of the hydrogel. The hydrogel modulus was affected by the hydrogel geometrical (diameter) parameters. SF/PU composite hydrogel can survive a million cycles, unconstrained fatigue resistance. More importantly, in vivo biocompatibility using New Zealand white rabbits, showed good biocompatibility over a three-month period in culture. Particularly, they showed the significant clinical merit of providing stronger axial compressive stiffness on confined compression test. Based on the outcomes of the present research, the SF/PU composite hydrogel may provide significant advantages for use in future clinical application in replacing nucleus pulposus field.