Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Rev Cardiovasc Med ; 24(7): 207, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39077022

RESUMEN

Background: Anaemia (low haemoglobin [Hb]) is well known to be associated with high mortality and adverse cardiac events following surgical treatment of abdominal aortic aneurysm (AAA). However, little is known about the relationship of AAA volume and Hb level alterations with endovascular repair of AAA. This study aimed to examine the changes in the Hb level and aneurysm volume before and after endovascular aneurysm repair (EVAR) for AAA and determine the relationship between the post-operative Hb level and the volume loss of AAA. Methods: This retrospective study reviewed patients with AAA who underwent EVAR between January 2020 and February 2021 at a tertiary medical centre. The clinical features and medical history of the patients were analysed. Alterations in the Hb level were recorded, and the AAA volume was calculated from computed tomography angiography images before and after EVAR to infer the association between the post-operative Hb level and alterations in AAA volume. Moreover, AAA volume, pre-operative Hb level and medical history were studied to identify the risk factors for anaemia 24 h after EVAR. Results: A total of 74 patients (mean age, 67 ± 7.9 years) were included in this study. The Hb level decreased significantly 24 h after EVAR, and the post-operative Hb level was negatively correlated with AAA volume loss (r = -0.252, p = 0.041). No relationship was observed between AAA volume loss and decrease in the Hb level (r = 0.072, p = 0.571) or between pre-operative AAA volume and decrease in the Hb level (r = 0.072, p = 0.566). Furthermore, 59.5% of the patients (n = 44) developed anaemia 24 h after EVAR. The odds ratio (OR) of anaemia 24 h after EVAR was 5.3 times higher in those with hypertension (OR, 5.304; 95% confidence interval [CI], 1.024-27.424) than in those without the condition. The pre-operative Hb level (or normal Hb level) was a protective factor (OR = 0.909; 95% CI, 0.853-0.969). The area under the receiver operating characteristic curve was 0.840. The post-operative Hb level declined significantly, and AAA volume loss contributed to it. Moreover, hypertension was identified to be a risk factor for anaemia 24 h after EVAR, and pre-operative Hb level was discerned to be a protective factor. Conclusions: The findings suggest that decrease in the Hb level in the early post-EVAR stage warrants the attention of surgeons, especially in patients with a history of hypertension or a low pre-operative Hb level.

2.
Heart Surg Forum ; 26(3): E271-E276, 2023 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-37401434

RESUMEN

BACKGROUND: To analyze the clinical effect of debranching thoracic endovascular aortic repair combined with ascending aortic banding. METHODS: The clinical data of patients who underwent a debranching thoracic endovascular aortic repair combined with ascending aortic banding at Anzhen Hospital (Beijing, China) between January 2019 and December 2021 were reviewed to evaluate the occurrence and outcomes of postoperative complications. RESULTS: A total of 30 patients underwent a debranching thoracic endovascular aortic repair combined with ascending aortic banding. There were 28 male patients (93.3%) with an average age of 59.9 ± 11.8 years. Twenty-five patients underwent simultaneous surgery and five patients had staged surgery. Postoperatively, two patients developed complete paraplegia (6.7%), three patients developed incomplete paraplegia (10%), two patients developed cerebral infarction (6.7%), and one patient developed femoral artery thromboembolism (3.3%). No patient died during the perioperative period, and one patient (3.3%) died during the follow-up period. None of the patients underwent retrograde type A aortic dissection during the perioperative and postoperative follow-up periods. CONCLUSIONS: Banding the ascending aorta with a vascular graft to restrict its movement and to serve as the proximal anchoring area of the stent graft can reduce the risk of retrograde type A aortic dissection.


Asunto(s)
Aneurisma de la Aorta Torácica , Reparación Endovascular de Aneurismas , Reparación Endovascular de Aneurismas/métodos , Humanos , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Disección Aórtica/cirugía , Disección de la Aorta Ascendente , Stents , Prótesis Vascular , Resultado del Tratamiento , Complicaciones Posoperatorias , Aneurisma de la Aorta Torácica/cirugía
3.
J Endovasc Ther ; 29(1): 132-142, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34342237

RESUMEN

PURPOSE: Aortic dissection (AD) is a catastrophic disease with complex hemodynamic conditions, however, understandings regarding its perfusion characteristics were not sufficient. In this study, a mock circulation loop (MCL) that integrated the Windkessel element and patient-specific silicone aortic phantoms was proposed to reproduce the aortic flow environment in vitro. MATERIALS AND METHODS: Patient-specific normal and dissected aortic phantoms with 12 branching vessels were established and embedded into this MCL. Velocities for aortic branches based on 20 healthy volunteers were regarded as the standardized data for flow division. By altering boundary conditions, the proposed MCL could mimic normal resting and left-sided heart failure (LHF) conditions. Flow rates and pressure status of the aortic branches could be quantified by separate sensors. RESULTS: In normal resting condition, the simulated heart rate and systemic flow rate were 60 bpm and 4.85 L/minute, respectively. For the LHF condition, the systolic and diastolic blood pressures were 75.94±0.77 mmHg and 57.65±0.35 mmHg, respectively. By tuning the vascular compliance and peripheral resistance, the flow distribution ratio (FDR) of each aortic branch was validated by the standardized data in the normal aortic phantom (mean difference 2.4%±1.70%). By comparing between the normal and dissected aortic models under resting condition, our results indicated that the AD model presented higher systolic (117.82±0.60 vs 108.75±2.26 mmHg) and diastolic (72.38±0.58 vs 70.46±2.33 mmHg) pressures, the time-average velocity in the true lumen (TL; 36.95 cm/s) was higher than that in the false lumen (FL; 22.95 cm/s), and the blood transport direction between the TL and FL varied in different re-entries. CONCLUSIONS: The proposed MCL could be applied as a research tool for in vitro hemodynamic analysis of the aorta diseases under various physical conditions.


Asunto(s)
Disección Aórtica , Disección Aórtica/diagnóstico por imagen , Aorta , Hemodinámica , Humanos , Modelos Cardiovasculares , Fantasmas de Imagen , Resultado del Tratamiento
4.
J Card Surg ; 37(10): 3426-3427, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35916149

RESUMEN

A stented elephant trunk graft entrapped in the false lumen during Sun's procedure (total arch replacement combined with stented elephant trunk implantation) is a serious complication with an extremely high mortality rate. This article describes a case of a patient who was successfully saved with the use of thoracic endovascular aortic repair.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Humanos , Stents , Resultado del Tratamiento
5.
J Card Surg ; 36(4): 1313-1319, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33522664

RESUMEN

BACKGROUND: This study aimed to evaluate the clinical outcomes of one-staged hybrid procedure for aortic lesions involving the distal aortic arch. METHODS: We retrospectively studied 99 consecutive patients who underwent the hybrid procedure (thoracic endovascular aortic repair combined with supra-arch branch vessel bypass) in our center between April 2009 and January 2020 for lesions involving the distal aortic arch. RESULTS: Median age was 64.0 (57.0-69.0) years, and 83 (83.8%) patients were male. There were five deaths in the perioperative period (three due to cerebral infarction and two due to intimal rupture). During the median follow-up of 41.0 months, 20 patients died, three had endoleak, one had a newly formed intimal tear, and two had femoral artery pseudoaneurysm. The 5- and 10-year survival rates of the total population were 72.2% and 48.8%, respectively. Additionally, there was no difference in the 5-year survival rate among the four groups according to different pathologies (Type B aortic dissection, aortic ulcer, aortic aneurysm, aortic pseudoaneurysm: 74.7%, 78.2%, 61.1%, and 75.5%, respectively, p = .58). Furthermore, there was no difference in the 5- and 10-year survival rates between the two groups according to the different bypass methods (right axillary artery [RAA]-left axillary artery [LAA] vs. RAA-LAA-left common carotid artery: 74.1% vs. 68.9%, p = .38). CONCLUSIONS: Although one-staged hybrid procedure has fewer complications in high-risk patients with lesions involving the distal aortic arch, the long-term survival rate is not optimistic.


Asunto(s)
Aorta Torácica , Aorta , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aorta/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Stents , Toracotomía , Resultado del Tratamiento
6.
Ann Vasc Surg ; 59: 237-243, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31009729

RESUMEN

BACKGROUND: The objective of the study was to investigate the hemodynamic changes of the blood flow in the aneurysm model after the multilayer stent placement using the fluid dynamic method, to analyze the effectiveness and properties of the multilayer stent in the treatment of aortic aneurysms. METHODS: A water tank was filled with 5 L of experimental liquid after the circular flow pressure test platform with a glass aneurysm model, and a multilayer stent was built. Pressure at the middle part and the distal aneurysm neck part of the model was then measured. At each site, the pressure was measured 20 times at 1-min intervals, and the testing results were averaged for accuracy. RESULTS: Without the stent, mean pressure at the middle part and at the distal aneurysm neck part of the model was 11.19 ± 0.23 Kpa and 13.31 ± 0.28 Kpa, respectively. With the stent, the mean pressure decreased to 10.60 ± 0.27 Kpa and 12.60 ± 0.29 Kpa, and the average difference was 0.59 ± 0.15 Kpa and 0.71 ± 0.15 Kpa, respectively. CONCLUSIONS: After the placement of the multilayer stent, pressure inside the model at the middle part and distal neck part could both be diminished, yet the mean dropped pressure may be too small to be sufficient to cause significant impact on preventing the expansion of abdominal aortic aneurysm; therefore, the pressure-lowering effect of the multilayer stent for abdominal aortic aneurysm may not be ideal compared with the traditional covered stents.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Presión Arterial , Procedimientos Endovasculares/instrumentación , Stents , Aneurisma de la Aorta Abdominal/fisiopatología , Velocidad del Flujo Sanguíneo , Humanos , Ensayo de Materiales , Modelos Anatómicos , Diseño de Prótesis , Flujo Sanguíneo Regional , Factores de Tiempo
7.
J Card Surg ; 32(12): 817-821, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29235151

RESUMEN

OBJECTIVE: This study aims to evaluate the results of one-stage ascending-to-abdominal aortic bypass and aortic valve replacement for concomitant aortic coarctation combined with aortic valve pathology. METHODS: From June 2009 to March 2017, 28 consecutive adult patients (23 males and five females) with aortic coarctation combined with aortic valve pathology underwent one-stage ascending-to-abdominal aorta bypass and aortic valve replacement or a Bentall procedure. Patients were followed for a mean of 45.5 ± 26.5 months (range 3-96 months). RESULT: All patients successfully underwent the one-stage procedure. No early deaths were recorded. The mean aortic cross-clamp and cardiopulmonary bypass times were 71 ± 23 and 113 ± 37 mins, respectively. Re-exploration for bleeding was performed on one patient (3.6%). The average post-operative hospital stay was 15.9 ± 4.9 days and the average operation time was 5.2 h. No paraplegia or stroke was observed. The blood pressure gradient of the upper and lower extremities significantly decreased (P < 0.001). Systolic blood pressure decreased from 158 ± 36 mmHg pre-operatively to 121 ± 18 mmHg post-operatively. No deaths or significant gradients between the upper and lower extremities occurred during follow-up. No death and complications of bypass grafts occurred during follow-up. CONCLUSION: Ascending-to-abdominal aortic bypass and concomitant aortic valve procedures are a suitable therapeutic option for severe aortic coarctation combined with aortic valve pathology in adult patients.


Asunto(s)
Aorta/cirugía , Coartación Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Injerto Vascular/métodos , Adulto , Coartación Aórtica/complicaciones , Insuficiencia de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/complicaciones , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
8.
J Vasc Surg ; 62(1): 43-8, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26115919

RESUMEN

OBJECTIVE: The objective of this study was to introduce a novel strategy for thoracic endovascular aortic repair of Stanford B aortic dissection using two-stent graft implantation (TSI), in which the proximal stent and distal stent with different sizes are sequentially deployed, and to summarize our experience with this technique. METHODS: A retrospective study was conducted of 72 consecutive patients (61 men; mean age, 55 ± 7 years; range, 41-67 years) with Stanford type B aortic dissection who underwent TSI treatment between January 2012 and May 2013. Among all patients, 43 (59.7%) involved the infrarenal aorta and 29 (40.3%) involved the whole thoracic and abdominal aorta; mean aortic involvement length was 226 ± 13 mm (range, 182-312 mm). Eight cases were for acute dissection (within 2 weeks from onset of symptoms), 11 cases were for chronic dissection (>3 months after initial dissection), and 53 cases were for subacute dissection (between 2 weeks and 3 months). Twenty-two cases (30.6%) were uncomplicated type and 50 cases (69.4%) were complicated type. Follow-up was performed postoperatively at 1 month, 6 months, and yearly thereafter. Technique success, aorta morphology, and procedure-related complications were evaluated. RESULTS: Technical success was achieved in 100%; 72 pairs of stent grafts (144 thoracic stent grafts) and 10 left subclavian artery chimney stents were used. The mean aortic length coverage by the stent grafts was 197.6 ± 20.3 mm, and mean taper diameter span was 7.5 ± 1.8 mm. All patients were followed up from 6 to 16 months (mean, 10 ± 4 months); 95.8% (69 of 72) had a thrombosed false lumen in the aortic coverage, and the true lumen expanded on average 57% ± 11% (23%-100%). No significant changes were found in aortic diameters of the proximal and distal ends of the two stent grafts and the angles between centerlines of the distal end of the stent and the aorta during follow-up. Procedure-related complications included transient paraplegia (coverage of the left subclavian artery without revascularization and extensive coverage of aorta >220 mm) due to acute spinal cord ischemia (n = 1) and malapposition of the distal stent (primary tear closed, true lumen expansion led to oversize rate insufficient in distal stent diameter; n = 1). No death or malperfusion complications were observed during the perioperative period and follow-up. CONCLUSIONS: Short-term outcomes showed TSI to be a flexible and effective approach to accurately repair Stanford B aortic dissection that could potentially address the limitations of currently available stent grafts. Further prospective clinical studies are warranted to evaluate its long-term efficacy.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Enfermedad Aguda , Adulto , Anciano , Disección Aórtica/diagnóstico , Angiografía de Substracción Digital , Aneurisma de la Aorta Torácica/diagnóstico , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Enfermedad Crónica , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
10.
J Card Surg ; 30(3): 274-5, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24934385

RESUMEN

Aberrant right subclavian artery (ARSA) is an uncommon congenital vascular abnormality. Acute Stanford type A aortic dissection with ARSA is rare. We report a strategy for Stanford type A aortic dissection with ARSA. The ascending aorta and the total aortic arch were replaced and a frozen elephant trunk was implanted into the descending aorta. The right subclavian artery was reconstructed with the perfusion branch of a four-branch prosthetic graft. Two weeks later, the proximal part of the ARSA was sealed with a vascular plug.


Asunto(s)
Aorta Torácica/cirugía , Aorta/cirugía , Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos de Cirugía Plástica/métodos , Arteria Subclavia/anomalías , Arteria Subclavia/cirugía , Enfermedad Aguda , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares/métodos
11.
Zhonghua Yi Xue Za Zhi ; 93(19): 1469-71, 2013 May 21.
Artículo en Zh | MEDLINE | ID: mdl-24029569

RESUMEN

OBJECTIVE: To retrospectively evaluate early and mid-term results of thoracic endovascular repair (TEVAR) of type B aortic dissection by the second generation of stent graft. METHODS: From January 2009 to January 2013, 383 acute, 43 sub-acute and 152 chronic patients with type B aortic dissection underwent TEVAR in our aortic center. The mean follow-up period was (27 ± 14) months. All clinical data were analyzed with SPSS 17.0. RESULTS: The 30-day mortality and morbidity were 0.35% and 1.2% respectively. The mid-term mortality and morbidity were 0.35% and 5.5%. Serious complications included retrograde type A dissection (n = 3), new tear at the distal end of stent (n = 26), endoleak (n = 3) and paraplegia (n = 0). The retreatment rate was 5.2% ( 6 patients were transformed to open operation and 24 patients underwent re-intervention). CONCLUSIONS: The early and mid-term results of thoracic endovascular repair (TEVAR) of type B aortic dissection by the second generation of stent graft showed lower mortality, no paraplegia and significant reduced endoleaks in comparison with the first generation stent graft. The new distal tear caused by the stent graft became the major complication. The design of the stent graft still need improvement.


Asunto(s)
Disección Aórtica/cirugía , Procedimientos Endovasculares , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Stents , Resultado del Tratamiento , Adulto Joven
12.
J Thorac Dis ; 15(8): 4306-4313, 2023 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-37691648

RESUMEN

Background: Although current research revealed the preoperative diameter of the aorta is related to aortic remodeling, prognosis should consider the true lumen (TL) and false lumen (FL) respectively too. Methods: The cohort of this retrospective analysis included 161 type A aortic dissection (TAAD) patients who underwent surgery at a single institution from September 1, 2017, to September 1, 2018. Computed tomography angiography (CTA) images were reviewed to assess changes of the diameters of the TL, FL and total aorta at the levels of the stented segment, distal end of the stent, celiac trunk, and below the renal artery. Results: During the study period, positive remodeling was observed in 33 (20.5%) patients. The probability of negative remodeling far from the stent segment was greater than the aorta close to the stent. Only the TL diameter was associated with each levels' changes and underwent significant change (P<0.05). Multivariate analysis identified aortic regurgitation as a risk factor for remodeling in the distal end of the stent. The maximum diameter of the FL was the only risk factor related to the remodeling type (odds ratio =0.10; 95% confidence interval: 0.01-0.51), a maximum diameter of the FL of >1.28 cm was associated with a higher probability of negative remodeling after surgery (specificity =0.994; sensitivity =0.571; area under the receiver operating characteristic curve =0.76). Conclusions: The TL and FL diameters on preoperative CTA images can be used to assess the risk of negative remodeling after surgery.

13.
Front Cardiovasc Med ; 9: 1035971, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36505364

RESUMEN

Objective: To determine the optimal timing of thoracic endovascular aortic repair (TEVAR) for patients with uncomplicated type B dissections who have a smoking history. Methods: Data from 308 consecutive patients with uncomplicated type B dissections, who have a smoking history and onset-to-TEVAR time within 90 days, were analyzed. The patients were divided into two groups: Acute and subacute phases. Univariate and multivariate regression analyses were performed. Smooth curve fitting and threshold analysis were performed to characterize the relationship between the onset-to-TEVAR time and follow-up deaths. Results: There were no significant differences between the two groups. Smooth curve fitting and threshold effect analysis showed that if early TEVAR was performed within 9.4 days from onset, there was better long-term survival and there was no significant difference after 9.4 days. Conclusion: By studying the relationship between onset-to-TEVAR time and all-cause mortality, we found that early TEVAR may have a lower all-cause mortality rate during follow-up in uncomplicated type B dissection patients who have a smoking history and within 90 days from onset.

14.
Front Cardiovasc Med ; 9: 869505, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35586645

RESUMEN

Background: Endovascular repair of type B aortic dissection (TBAD) with aberrant right subclavian artery (ARSA) is challenging due to anatomical complexity. The embedded modular single-branched stent graft (EMSBSG) could solve this problem. However, the hemodynamic efficacy of this innovative technique has not been fully assessed. This study aimed to propose morphometric and functional indicators to quantify the outcomes of EMSBSG in treating TBAD with ARSA. Material and Methods: A patient who had TBAD with ARSA underwent EMSBSG implantation was admitted. Computational fluid dynamics (CFD) and three-dimensional structural analyses were conducted based on CTA datasets before the operation (Pre-1) and at 4 and 25 days after EMSBSG implantation (Post-1 and Post-2). Quantitative and qualitative functional analyses were conducted via pressure-, velocity- and wall shear stress (WSS) -based parameters, such as the luminal pressure difference (LPD), total energy loss, and flow distribution ratio. By precisely registering the aortas at the three time points, parameter variations in the EMSBSG region were also computed to investigate the prognostic improvement after EMSBSG implantation. Results: The first balance point of LPD distally shifted to the abdominal aorta in Post-1 by a distance of 20.172 cm, and shifted out of the dissected region in Post-2, indicating positive pressure recovery post EMSBSG. The flow distribution ratios of all aortic arch branches increased after EMSBSG implantation. A positive normal deformation index in the EMSBSG region confirmed true lumen expansion; dominant ARN (area ratio of negative value) of pressure and WSS-based parameters indicated an improved prognosis from Post-1 to Post-2. Conclusions: The short-term results of EMSBSG in treating TBAD with ARSA proved to be promising, especially in EMSBSG region. Comprehensive evaluation could provide new insight into the therapy of TBAD with ARSA. Thus, it might guide the further management of complex aortic arch lesions.

15.
Quant Imaging Med Surg ; 11(6): 2861-2878, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34079747

RESUMEN

Infectious aortitis (IA) is a rare and life-threatening cardiovascular disease. Early diagnosis and timely intervention are crucial for reducing mortality associated with mycotic aortic aneurysms (MAAs); however, early diagnosis is challenging due to the nonspecific symptoms. Some cases are diagnosed at an advanced stage or after developing complications, such as rupture or aortic fistula. Current state-of-the-art imaging modalities-including computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT-can detect infected aneurysms in clinically suspicious cases. MAA features on imaging include lobulated pseudoaneurysm, indistinct irregular arterial wall, perianeurysmal gas, perianeurysmal edema, perianeurysmal soft tissue mass, aneurysmal thrombosis, and high metabolic activity with increased uptake of FDG. Enlarged lymph nodes are often found adjacent to the aneurysm, while iliopsoas abscess (IPA), spondylitis, and aortic fistulas are commonly associated complications. After surgery or endovascular repair, radiological features-including ectopic gas, peri-graft fluid, thickening of adjacent bowel, pseudoaneurysm formed at the graft anastomosis, and increased uptake of FDG-may indicate an infection of aortic graft. This article provides an overview of the clinical and imaging features of MAAs. Thus, familiarity with the imaging appearances of MAAs may assist radiologists in the diagnosis and facilitation of timely treatment.

16.
Ther Adv Chronic Dis ; 12: 20406223211026753, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34221307

RESUMEN

BACKGROUND: To investigate the efficacy and safety of biologics in the perioperative management of severe aortic valve regurgitation (AR) caused by Behçet syndrome (BS). METHODS: We retrospectively analyzed 20 patients with severe AR caused by BS who were all treated with biologics during the perioperative period of cardiac surgeries in our center between February 2016 and October 2020. RESULTS: A total of 20 patients with severe AR were enrolled, including 19 males and 1 female, with a mean age of 39.1 ± 8.8 years and a median course of 8 [interquartile range (IQR) 5.25-10.00] years. Before biologic administration, 92.9% of the patients who underwent aortic valve replacement had failed conventional therapy and developed postoperative paravalvular leakage (PVL) at a median interval of 4 months. Biologics were administered with background glucocorticoids (GCs) and immunosuppressants during the perioperative period for 22 aortic valve surgeries, including preoperatively with a median interval of 3.5 (IQR 2.75-4.25) months in 13 cases and within 3 months postoperatively in 9 cases. After a median follow up of 21 (IQR 15-32) months, 2 out of 13 cases (15.4%) preoperatively, and 1 out of 9 cases (11.1%) postoperatively treated with biologics developed PVL, and the rest were event free. The Behçet's Disease Current Activity Form score improved significantly (7 versus 0, median, p < 0.0001). Decrease of erythrocyte sedimentation rate [25.0 (IQR 11.00-36.25) mm/h versus 6.5 (IQR 4.0-8.8) mm/h, p < 0.001], and C-reactive protein [20.77 (IQR 7.19-29.58) mg/l versus 1.53 (IQR 0.94-2.92) mg/l, p = 0.001] were achieved rapidly and effectively. The GC dosage tapered from 40 (IQR 30-60) mg/d to 10 (IQR 5-11.25) mg/d, p < 0.0001. Immunosuppressants were tapered in number and dosage in 6 (30%) and 20 patients (100%), respectively. No serious adverse event was observed. CONCLUSION: Our study suggests that biologics were effective and well tolerated for the perioperative management of severe and refractory AR caused by BS, which significantly reduced the occurrence of postoperative PVL and had favorable GC- and immunosuppressant-sparing effect.

17.
Transplant Proc ; 52(1): 419-422, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31948801

RESUMEN

BACKGROUND: In the design and development of small-caliber artificial blood vessels, endothelialization is a key issue, but it is not well understood at present. Some studies have used vascular endothelial growth factor (VEGF) sustained-release methods to promote endothelial cell proliferation. However, this method is not ideal. This study has used drugs to induce endothelial cells to produce VEGF. This method in turn functions to promote cell proliferation and promote the endothelialization of artificial blood vessels. This study aimed to investigate the effect of the antiplatelet drug tirofiban on endothelial cell proliferation in vitro. METHODS: In this study, human umbilical vein endothelial cells (HUVECs) were used to determine the effect of tirofiban-stimulated cell proliferation. Analysis of cell proliferation, assayed by the Cell Counting Kit-8 assay, showed that the number of cells was increasingly higher than in the absence of tirofiban. It was also observed that heparin enhanced the tirofiban effect. The cell VEGF expression at different time points after tirofiban addition was detected by western blot analysis. RESULTS: The absorbance values of the experimental (1 µg/mL tirofiban) and the control groups (0 tirofiban) were 1.74 (SD, 0.03) and 1.51 (SD, 0.07) (P < .001), respectively, after 4 days of culture under the same conditions. The amount of VEGF produced by HUVECs gradually increased after treatment with tirofiban, reached a peak at 2 hours, and was 1.3-fold greater than the control group (P = .034). Compared with the tirofiban-only group, the absorbance value of the tirofiban and 10 µg/mL of heparin group was significantly increased (P < .001). CONCLUSIONS: Tirofiban promoted the proliferation of HUVECs by promoting the synthesis of VEGF in HUVECs. Heparin enhanced tirofiban activity in promoting HUVEC proliferation.


Asunto(s)
Proliferación Celular/efectos de los fármacos , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Inhibidores de Agregación Plaquetaria/farmacología , Tirofibán/farmacología , Factor A de Crecimiento Endotelial Vascular/biosíntesis , Células Cultivadas , Humanos
18.
Quant Imaging Med Surg ; 10(7): 1504-1514, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32676368

RESUMEN

BACKGROUND: To determine the prevalence, clinical and imaging features of intimal tear detected by ECG-gated multidetector computed tomography (MDCT) and confirmed by surgery in patients with acute type A intramural hematoma (ATAIMH) and acute type A aortic dissection (AAAD). METHODS: This retrospective study involved analysis of the intimal tear characteristics in 72 consecutive patients with ATAIMH and 209 with AAAD who were diagnosed by MDCT. The size and location of the intimal tear were measured and compared between these two groups of patients. The findings were also compared with those from 28 patients with ATAIMH who underwent surgical treatment to determine the intimal tear features as observed on CT angiography (CTA). RESULTS: Patients in the ATAIMH group were significantly older than those in the AAAD group (58.6±11.3 vs. 49.4±12.8 years, P<0.001), and females were predominant in the former category (ATAIMH vs. AAAD: 44.4% vs. 27.8%, P<0.01). Marfan syndrome and pregnancy were associated with most of the occurrences of AAAD. Sixty-four patients (88.9%) with ATAIMH were recognized as having intimal tear in the CTA images. The number of aortic segments in the ATAIMH patients was smaller than that in the AAAD patients (4.45±1.56 vs. 5.04±1.72 segments, P<0.01). The distribution of the intimal tear did not show any difference between the two groups. During the surgery, pericardial hemorrhage was observed in a higher proportion of patients in the ATAIMH than in the AAAD group (60.7% vs. 22.1%; P<0.01). In the former category, all of the intimal tears detected using CTA were confirmed during the operation, and the size was significantly larger than measured on the CTA images (6.95±5.12 vs. 19.59±6.51 mm, P<0.001). Six ATAIMH patients progressed to classical aortic dissection (AD) at surgery. CONCLUSIONS: Patients with ATAIMH have a high prevalence of intimal tear, which is significantly smaller than that measured in patients with classic AAAD. Just like AD, ATAIMH may also be triggered by intimal tear. Hence, timely surgical repair is needed.

20.
Chin Med J (Engl) ; 133(4): 402-407, 2020 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-31977549

RESUMEN

BACKGROUND: The preferred treatment for uncomplicated type B dissection (thoracic endovascular aortic repair [TEVAR] or medical) is still under debate. Since 2001, our center has performed TEVAR for uncomplicated type B dissection. Based on our data, 5- and 10-year survival rates among patients with uncomplicated type B dissection after TEVAR were 96.5% and 83.0%, respectively. We, therefore, believe that TEVAR is preferable for uncomplicated type B dissections. This study analyzed the impact of a pre-operative smoking history on long-term survival after TEVAR in patients with uncomplicated type B dissections. METHODS: From May 2001 to December 2013, data from 751 patients with type B dissections were collected and analyzed. Patients were divided into two groups (337 smoking patients and 414 non-smoking patients). The Kaplan-Meier method and log-rank test were used to compare survival curves of the two groups. Multivariable analyses using the Cox proportional hazards model were used to estimate the effects of smoking on survival rates. RESULTS: The 5- and 10-year survival rates of non-smokers were 97.6% (95% confidence interval [CI], 96.0%-99.2%) and 87.0% (95% CI, 81.6%-92.7%), respectively, and 94.9% (95% CI, 92.2%-97.7%) and 73.8% (95% CI, 62.3%-87.5%) for smokers, respectively (Log-rank test, P = 0.006). Multivariable analyses showed that smoking increased the risk of death during follow-up, 2.1-fold when compared to non-smokers (P = 0.039). CONCLUSION: A pre-operative smoking history increases long-term mortality rates after TEVAR in patients with uncomplicated type B dissections.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Fumar/efectos adversos , Adulto , Anciano , Disección Aórtica/mortalidad , Aneurisma de la Aorta Torácica/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA