Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Cureus ; 14(5): e25548, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35783884

RESUMEN

We report the case of a 49-year-old woman presenting with amenorrhea and progressive visual field defect for one month. Endocrinological workup revealed a high concentration of serum prolactin, and magnetic resonance imaging (MRI) showed pituitary macroadenoma with extrasellar extension as well as compression of optic nerves. Treatment with a dopamine agonist, cabergoline, for eight weeks led to the resolution of the visual field defect accompanied by a rapid decrease in the serum prolactin level. Follow-up MRI three months after the initial diagnosis revealed alleviation of visible mechanical compression of the optic chiasm by the tumor. We considered that the absence of retinal nerve damage and prompt initiation of cabergoline contributed to the rapid recovery of the visual acuity.

2.
Case Rep Ophthalmol ; 10(1): 53-60, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31097945

RESUMEN

We report two cases of aphakia in whom an intraocular lens (IOL) was intrasclerally fixated through the pars plana to minimize further corneal endothelial damage. A modified lock-and-lead technique was used. A sclerotomy and scleral incision were made 2.5 mm from the limbus. A 24-G catheter needle was used for penetration of the leading haptic, and two ultrathin 30-G needles were used to bury the ends of the haptics. The scleral incision was sutured with 8-0 nylon. Corneal endothelial cells were preserved after surgery. Neither intra- nor postoperative complications were observed. Intrascleral fixation of an IOL through the pars plana effectively minimizes further damage to corneal endothelial cells in select cases.

3.
Eur J Ophthalmol ; 29(4): 458-463, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29877117

RESUMEN

PURPOSE: To develop a new technique for the placement of a Baerveldt glaucoma implant tube through a long scleral tunnel. MATERIALS AND METHODS: Patients with refractory glaucoma undergoing the maximum tolerated medical therapy were recruited. We created a scleral tunnel with a 24-gauge catheter needle and used the external tube for guidance when introducing a Baerveldt glaucoma implant tube. Main outcome measures included intraocular pressure, supplemental medical therapy score, intraoperative complications, and postoperative complications. RESULTS: Nine eyes of six patients were included in the study. The mean preoperative intraocular pressure (score) was 41.0 mmHg (4.78). Mean postoperative intraocular pressures were 18.3 mmHg (0.22), 18.8 mmHg (0.13), and 16.9 mmHg (0.50) at postoperative 1, 3, and 6 months, respectively. Minor vitreous hemorrhages were observed in three cases. Postoperative hypotony (<5 mmHg) was observed only in the first case at postoperative day 3. In one case, a stent suture could not be placed because the patient was restive intraoperatively, which resulted in an expulsive hemorrhage at 3 months postoperatively. The tube could have penetrated into the anterior chamber in another case. Tube exposure and corneal erosions were not observed in all cases. CONCLUSION: We developed a new technique to place a Baerveldt glaucoma implant tube through a long scleral tunnel. The outcomes were comparable to other reports of Baerveldt glaucoma implant surgery, although the number of cases was limited in this study. A long scleral tunnel can substitute for a preserved scleral patch and self-scleral flap to avoid tube-related complications.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma Neovascular/cirugía , Implantación de Prótesis/métodos , Esclerótica/cirugía , Colgajos Quirúrgicos , Adulto , Anciano , Retinopatía Diabética/complicaciones , Femenino , Glaucoma Neovascular/etiología , Humanos , Presión Intraocular/fisiología , Complicaciones Intraoperatorias , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos , Tonometría Ocular
4.
Eur J Ophthalmol ; 27(4): 509-511, 2017 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-28430320

RESUMEN

PURPOSE: To describe a new technique for remnant removal in cases of posterior capsular rupture during cataract surgery and Soemmering ring extraction during intraocular lens (IOL) removal. METHODS: An IOL injector, inserted into the anterior chamber, provides a new exit for residual lens fragments. Passive fluid flow, supplied by an anterior chamber maintainer or some ocular viscoelastic device (OVD) injection, delivers the residual fragments into a lumen of the injector in assistance with a second device such as a phaco-chopper and vitreous cutter. RESULTS: Soemmering rings can be removed safely through small incisions even when under the iris. Nucleus fragments in anterior chamber can be removed safely. Fragments that fall into the vitreous cavity can float up for removal by passive flow. CONCLUSIONS: This new technique, remnant extraction through lens injector with essential flow, has several practical advantages over existing methods including reduced OVD injection and smaller incision size. It may offer an alternative to existing methods of remnant removal in cases of posterior capsular rupture during cataract surgery and Soemmering ring extraction.


Asunto(s)
Cámara Anterior/cirugía , Extracción de Catarata/efectos adversos , Remoción de Dispositivos/métodos , Cuerpos Extraños/cirugía , Lentes Intraoculares , Ruptura de la Cápsula Posterior del Ojo/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Subluxación del Cristalino/cirugía , Masculino , Persona de Mediana Edad , Ruptura de la Cápsula Posterior del Ojo/etiología , Sustancias Viscoelásticas/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA