J Phys Ther Sci ; 32(6): 405-409, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32581434

RESUMEN

[Purpose] We evaluated the reliability of the measurement function of the Honda Walking Assist Device and investigated the effect of the device on walking improvements, and foot and ankle function, in hemiplegic stroke patients. [Participants and Methods] We recruited 16 hemiplegic stroke patients who performed 10-meter walk tests, twice without assistance and once with device assistance. Based on the rate of change of velocity, we divided the participants into two groups and compared the walking parameters, the toe grip strength, the cross tests, and the maximum step width. Two examiners assessed the 10-meter walk test results, and the authors calculated the intraclass correlation coefficients for walking speed, stride length, cadence, flexion, extension, and scissor angles. [Results] The intraclass correlation coefficients were greater than 0.70 for all the walking parameters we measured. The device increased hip joint movement but did not alter the maximum walking speed of the stroke patients. The patients in the group with a greater change in velocity displayed lower toe grip strength and decreased maximum step width and used orthoses more commonly. [Conclusion] The walking measurement function of the device was reliable. The immediate effect of the device in stroke patients may be influenced by the level of paralysis and the presence of an orthosis.