Guang Pu Xue Yu Guang Pu Fen Xi ; 36(10): 3351-4, 2016 Oct.
Artículo en Zh | MEDLINE | ID: mdl-30246987

RESUMEN

A separation/preconcentration procedure with coprecipitation has been proposed for the flame atomic absorption spectrometric (FAAS) determination of cadmium at trace level in food and environmental samples. Manganese(Ⅱ) was used as a carrier which chelated with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol to detect the content of trace cadmium in shrimp and shell fish samples with flame atomic absorption spectrometry for the first time. The precipitate could be easily dissolved with concentrated nitric acid. The optimum coprecipitation of this new method including the amount of reagent, amount of manganese(Ⅱ), the pH, and the standing time of the precipitate had been confirmed for the quantitative recoveries of the analytes. The effect of matrix ions and the interference of co-existing ions were also evaluated. Under the experimental conditions established by the optimization step, the system of Mn(Ⅱ)-5-Br-PADAP was able to overcome the matrix interference which showed the effect of separation and enrichment well. The linear range of cadmium content was determined to be 0.1~1.0 mg·L-1. The sensitivity and the relative standard deviation(RSD) were found 0.147(mg·L-1)-1, 0.73%, respectively. The optimum procedure allows the determination of cadmium with limit of detection of 4.27 µg·L-1. The complexity of preprocessing was determined by the complexity of food samples. So the differences of cadmium content in the samples between the direct determination with atomic absorption spectrometry and the measurement after coprecipitation were examined, which providedevidences for the superiority of the system again. Cadmium in shell fish and shrimp samples were 1.85 mg·kg-1 and 1.74 mg·kg-1, which in line with international standards of the Codex Alimentarius Commission(CAC). The credibility of the method was evaluated by standard additional method and recovery experiments. The standard addition recoveries of sample and RSDs of the method were in the range of 99.9%~100.3% and 0.15%~0.83%. The results of recovery experiment showed that the presented coprecipitation procedure had good repetition, high accuracy. In addition, with the method, we could draw conclusions that the experiments were simple and rapid. The developed method described in the literature was successfully applied for the determination of trace cadmium in shrimp and shell fish samples with satisfactory results.


Asunto(s)
Cadmio/análisis , Espectrofotometría Atómica , Animales , Compuestos Azo , Quelantes , Crustáceos , Concentración de Iones de Hidrógeno , Indicadores y Reactivos , Moluscos
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(5): 1357-9, 2013 May.
Artículo en Zh | MEDLINE | ID: mdl-23905351

RESUMEN

A method was proposed for the determination of trace lead with flame atomic absorption spectrometry after preconcentration of lead by rapid coprecipitation technique with PAR-Fe (III) at pH 6.0. The analytical parameters including pH, amount of iron (III), amount of reagent, the standing time of the precipitate, etc., were examined. The detection limits (DL) were found to be 18.7 microg x L(-1) for Pb (II). In analysis of lake water and the milk tea powder samples, RSD's and the standard addition recovery of this method were in the ranges of 1.03%-2.24% and 94.2%-98.3% respectively. The effect of matrix can be overcome by the method and the results are satisfyiog. The method shows good application prospect in the determination of trace lead owing to its rapidness and reproducibility.


Asunto(s)
Contaminación de Alimentos/análisis , Plomo/análisis , Leche/química , Espectrofotometría Atómica/métodos , Agua/química , Animales , Precipitación Química , Contaminantes Químicos del Agua/análisis