Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Hand Surg Am ; 38(6): 1097-105, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23707009

RESUMEN

PURPOSE: The treatment of distal radius fractures with volar locked plating (VLP) has gained popularity. Many different designs and sizes of plates afford a wide variety of configurations of locking screws that can be placed into the distal fracture fragment. The purpose of this study was to determine whether using half of the distal locking screws decreased stability when compared with using all possible distal locking screws with 4 different VLP systems. METHODS: Twenty-four identical synthetic distal radius sawbone models were instrumented with 1 of 4 designs of VLP devices over a standardized dorsal wedge osteotomy to simulate a dorsally comminuted, extra-articular distal radius fracture. Distal locking screws were placed in varying configurations. Six radii per plate model with different screw configurations then underwent axial loading, volar bending, and dorsal bending using a servohydraulic machine. Distal fragment displacement was recorded using a differential variable reluctance transducer. RESULTS: There was no significant difference in fracture fragment displacement when using half of the distal locking screw set compared with using the full screw set. Mean differences in displacement between half and full screws were less than 0.1 mm. All configurations had the greatest magnitude of displacement during axial loading. Mean displacement was less in plates containing 2 rows of distal locking screws (-0.4 mm) compared with plates containing 1 row (-0.6 mm). CONCLUSIONS: Using half of the distal locking screws in VLP in an extra-articular, nonosteoporotic distal radial fracture model with noncyclical, nondestructive loading does not decrease construct stability compared with using all of the screws. Not filling all holes in VLP is more cost effective and does not sacrifice plate stiffness or construct stability. Plates with 2 rows of distal locking screws create more stable fixation than plates with 1 row of distal locking screws.


Asunto(s)
Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Fracturas del Radio/fisiopatología , Fracturas del Radio/cirugía , Placas Óseas , Diseño de Equipo , Fijación Interna de Fracturas/métodos , Fracturas Conminutas/cirugía , Humanos , Ensayo de Materiales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA