Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Cardiovasc Comput Tomogr ; 18(2): 142-153, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38143234

RESUMEN

BACKGROUND: Coronary computed tomography angiography (CCTA) analysis is currently performed by experts and is a laborious process. Fully automated edge-detection methods have been developed to expedite CCTA segmentation however their use is limited as there are concerns about their accuracy. This study aims to compare the performance of an automated CCTA analysis software and the experts using near-infrared spectroscopy-intravascular ultrasound imaging (NIRS-IVUS) as a reference standard. METHODS: Fifty-one participants (150 vessels) with chronic coronary syndrome who underwent CCTA and 3-vessel NIRS-IVUS were included. CCTA analysis was performed by an expert and an automated edge detection method and their estimations were compared to NIRS-IVUS at a segment-, lesion-, and frame-level. RESULTS: Segment-level analysis demonstrated a similar performance of the two CCTA analyses (conventional and automatic) with large biases and limits of agreement compared to NIRS-IVUS estimations for the total atheroma (ICC: 0.55 vs 0.25, mean difference:192 (-102-487) vs 243 (-132-617) and percent atheroma volume (ICC: 0.30 vs 0.12, mean difference: 12.8 (-5.91-31.6) vs 20.0 (0.79-39.2). Lesion-level analysis showed that the experts were able to detect more accurately lesions than the automated method (68.2 â€‹% and 60.7 â€‹%) however both analyses had poor reliability in assessing the minimal lumen area (ICC 0.44 vs 0.36) and the maximum plaque burden (ICC 0.33 vs 0.33) when NIRS-IVUS was used as the reference standard. CONCLUSIONS: Conventional and automated CCTA analyses had similar performance in assessing coronary artery pathology using NIRS-IVUS as a reference standard. Therefore, automated segmentation can be used to expedite CCTA analysis and enhance its applications in clinical practice.


Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Humanos , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Reproducibilidad de los Resultados , Ultrasonografía Intervencional/métodos , Valor Predictivo de las Pruebas , Algoritmos , Vasos Coronarios/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen
2.
Front Cardiovasc Med ; 10: 1250800, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37868778

RESUMEN

Introduction: Changes in coronary artery luminal dimensions during the cardiac cycle can impact the accurate quantification of volumetric analyses in intravascular ultrasound (IVUS) image studies. Accurate ED-frame detection is pivotal for guiding interventional decisions, optimizing therapeutic interventions, and ensuring standardized volumetric analysis in research studies. Images acquired at different phases of the cardiac cycle may also lead to inaccurate quantification of atheroma volume due to the longitudinal motion of the catheter in relation to the vessel. As IVUS images are acquired throughout the cardiac cycle, end-diastolic frames are typically identified retrospectively by human analysts to minimize motion artefacts and enable more accurate and reproducible volumetric analysis. Methods: In this paper, a novel neural network-based approach for accurate end-diastolic frame detection in IVUS sequences is proposed, trained using electrocardiogram (ECG) signals acquired synchronously during IVUS acquisition. The framework integrates dedicated motion encoders and a bidirectional attention recurrent network (BARNet) with a temporal difference encoder to extract frame-by-frame motion features corresponding to the phases of the cardiac cycle. In addition, a spatiotemporal rotation encoder is included to capture the IVUS catheter's rotational movement with respect to the coronary artery. Results: With a prediction tolerance range of 66.7 ms, the proposed approach was able to find 71.9%, 67.8%, and 69.9% of end-diastolic frames in the left anterior descending, left circumflex and right coronary arteries, respectively, when tested against ECG estimations. When the result was compared with two expert analysts' estimation, the approach achieved a superior performance. Discussion: These findings indicate that the developed methodology is accurate and fully reproducible and therefore it should be preferred over experts for end-diastolic frame detection in IVUS sequences.

3.
Anatol J Cardiol ; 26(3): 218-225, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35346908

RESUMEN

OBJECTIVE: To investigate the safety and efficacy of a percutaneous revascularization strategy that is based on the use of drug-coated balloon for the treatment of patients with acute coronary syndrome and de novo Medina type 0,1,0 or 0,0,1 left main stem bifurcation lesions. METHODS: In this multicenter, prospective, proof-of-concept study, patients fulfilling the above criteria were enrolled and received treatment with drug-coated balloon combined with provisional drug-eluting stent implantation in the proximal major branches of the left main stem. Patients who declined this revascularization approach were treated with drug-eluting stent implantation 1-2 mm distally to the left anterior descending or left circumflex artery ostium followed by drug-coated balloon therapy for the ostial disease. The primary endpoint of the study was the calculation of percent diameter stenosis on quantitative coronary angiography post-procedure as well as event rate at 8 months follow-up. RESULTS: A total of 30 patients were enrolled in the study; their mean age was 60.3 ± 7.8 years, while 22 (73.3%) were male. Twenty-two patients were treated only with drugcoated balloon and provisional drug-eluting stent implantation and 8 had drug-eluting stent implantation followed by drug-coated balloon therapy of the ostium of the left main stem major branch. All the procedures were successful with no immediate complications. The percent diameter stenosis of lesion decreased significantly post-procedure from 87.5% (80.0-90.0) to 20% (17.5-30.0), P <.001. During the follow-up period, no major adverse cardiac events were reported. CONCLUSIONS: This proof-of-concept study indicates that ostial drug-coated balloon therapy of the left main stem major branches is safe and effective. Larger clinical data and longer follow-up are needed before advocating its regular use in clinical practice.


Asunto(s)
Angioplastia Coronaria con Balón , Stents Liberadores de Fármacos , Anciano , Angiografía Coronaria , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
4.
Front Cardiovasc Med ; 9: 890799, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35722127

RESUMEN

Background: Intravascular imaging has been used to assess the morphology of lesions causing an acute coronary syndrome (ACS) in native vessels (NV) and identify differences between plaques that ruptured (PR) and caused an event and those that ruptured without clinical manifestations. However, there is no data about the morphological and physiological characteristics of neoatherosclerotic plaques that ruptured (PR-NA) which constitute a common cause of stent failure. Methods: We retrospectively analyzed data from patients admitted with an acute myocardial infarction that had optical coherence tomography (OCT) imaging of the culprit vessel before balloon pre-dilation. OCT pullbacks showing PR were segmented at every 0.4 mm. The extent of the formed cavity, lipid and calcific tissue, thrombus, and macrophages were measured, and the fibrous cap thickness (FCT) and the incidence of micro-channels and cholesterol crystals were reported. These data were used to reconstruct a representative model of the native and neoatherosclerotic lesion geometry that was processed with computational fluid dynamics (CFD) techniques to estimate the distribution of the endothelial shear stress and plaque structural stress. Result: Eighty patients were included in the present analysis: 56 had PR in NV (PR-NV group) and 24 in NA segments (PR-NA group). The PR-NV group had a larger minimum lumen area (2.93 ± 2.03 vs. 2.00 ± 1.26 mm2, p = 0.015) but similar lesion length and area stenosis compared to PR-NA group. The mean FCT (186 ± 65 vs. 232 ± 80 µm, p = 0.009) and the lipid index was smaller (16.7 ± 13.8 vs. 25.9 ± 14.1, p = 0.008) while the of calcific index (8.3 ± 9.5 vs. 2.2 ± 1.6%, p = 0.002) and the incidence of micro-channels (41.4 vs. 12.5%, p = 0.013) was higher in the PR-NV group. Conversely, there was no difference in the incidence of cholesterol crystals, thrombus burden or the location of the rupture site between groups. CFD analysis revealed higher maximum endothelial shear stress (19.1 vs. 11.0 Pa) and lower maximum plaque structural stress (38.8 vs. 95.1 kPa) in the PR-NA compared to the PR-NV model. Conclusion: We reported significant morphological and physiological differences between culprit ruptured plaques in native and stented segments. Further research is needed to better understand the causes of these differences and the mechanisms regulating neoatherosclerotic lesion destabilization.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA