Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38782043

RESUMEN

BACKGROUND: Dexamethasone, an efficacious anti-inflammatory agent, is widely used after tooth extraction. However, its optimal injection site is yet to be investigated. PURPOSE: We compare the efficacy of dexamethasone injection at different sites on postoperative sequelae after extracting mandibular impacted third molars (MITMs). STUDY DESIGN, SETTING, AND SAMPLE: A prospective randomized controlled trial was conducted. Healthy adults with fully MITMs scheduled for extraction were included. Exclusion criteria were 1) patients with the systemic alteration that prevented the surgical procedure; 2) pregnancy, breastfeeding, and premenstrual period; 3) hypersensitivity to the drug under test; and 4) those who did not return for postoperative follow-up at 1, 3, and 7 days. EXPOSURE VARIABLE: The subjects were randomized to 3 groups. An online randomization plan generator assigned each subject to a single treatment by randomly permuting blocks. Different sites for postoperative dexamethasone injections included the buccal side of the adjacent second molar and extraction sockets. Dexamethasone injection (4 mg) on the buccal side of the adjacent second molar (group 1), an injection on the buccal side of extraction sockets (group 2), and an injection of physiological saline (0.8 mL) on the buccal side of the adjacent second molar (control). MAIN OUTCOME VARIABLES: The outcome variables were postoperative facial swelling, limitation of the mouth opening, postoperative pain, and postoperative quality of life evaluation. The pain was assessed using a visual analog scale at 1, 3, and 7 days, postoperatively. The quality of life was recorded throughout the Posse scale at 7 days. COVARIATES: The covariates are age, sex, length of operation, and type of impacted teeth and surgery. ANALYSES: The statistical analysis was performed using analysis of variance, repeated measures analysis of variance, χ2 test, or Fisher's exact tests with P values < .05 considered statistically significant. RESULTS: Our study included 58 participants with a mean age of 19.48 ± 3.31 years; group 1 (n = 24), group 2 (n = 20), and control group (n = 14). On day 3 postoperative, the swelling and trismus were significantly less in group 1 than in the other 2 groups (P < .05), and group 1 had an overall postoperative quality of life compared to other groups (P < .05). Unaffected speech function was present in 73.7% of patients in group 1, while 50% of patients in group 2 had affected speech function 3 days after the operation (P < .05). The "unable to open mouth" of the "Eating subscale" and "felt tingling" had statistical significance (P < .05). CONCLUSION AND RELEVANCE: Dexamethasone injections on the buccal side of the adjacent second molar can be a viable option for treating facial swelling and limitation of mouth opening after total MITMs extraction.

2.
Mater Horiz ; 11(8): 2010-2020, 2024 04 22.
Artículo en Inglés | MEDLINE | ID: mdl-38362790

RESUMEN

Flexible and stretchable heaters are increasingly recognized for their great potential in wearable thermotherapy to treat muscle spasms, joint injuries and arthritis. However, issues like lengthy processing, high fabrication cost, and toxic chemical involvement are obstacles on the way to popularize stretchable heaters for medical use. Herein, using a single-step customizable laser fabrication method, we put forward the design of cost-effective wearable laser-induced graphene (LIG) heaters with kirigami patterns, which offer multimodal stretchability and conformal fit to the skin around the human body. First, we develop the manufacturing process of the LIG heaters with three different kirigami patterns enabling reliable stretchability by out-of-plane buckling. Then, by adjusting the laser parameters, we confirm that the LIG produced by medium laser power could maintain a balance between mechanical strength and electrical conductivity. By optimizing cutting-spacing ratios through experimental measurements of stress, resistance and temperature profiles, as well as finite element analysis (FEA), we determine that a larger cutting-spacing ratio within the machining precision will lead to better mechanical, electrical and heating performance. The optimized stretchable heater in this paper could bear significant unidirectional strain over 100% or multidirectional strain over 20% without major loss in conductivity and heating performance. On-body tests and fatigue tests also proved great robustness in practical scenarios. With the advantage of safe usage, simple and customizable fabrication, easy bonding with skin, and multidirectional stretchability, the on-skin heaters are promising to substitute the traditional heating packs/wraps for thermotherapy.


Asunto(s)
Grafito , Hipertermia Inducida , Rayos Láser , Dispositivos Electrónicos Vestibles , Humanos , Hipertermia Inducida/métodos , Hipertermia Inducida/instrumentación , Diseño de Equipo , Análisis de Elementos Finitos , Conductividad Eléctrica
3.
Mater Horiz ; 11(10): 2528, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38686646

RESUMEN

Correction for 'Kirigami-enabled stretchable laser-induced graphene heaters for wearable thermotherapy' by Junyu Chen et al., Mater. Horiz., 2024, 11, 2010-2020, https://doi.org/10.1039/D3MH01884A.

4.
Technol Cancer Res Treat ; 23: 15330338231225864, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38311933

RESUMEN

Purpose: This study aims to develop a data-collecting package ExpressMLC and investigate the applicability of MapCHECK2 for multileaf collimator (MLC) modeling and commissioning for complex radiation treatment plans. Materials and methods: The MLC model incorporates realistic parameters to account for sophisticated MLC features. A set of 8 single-beam plans, denoted by ExpressMLC, is created for the determination of parameters. For the commissioning of the MLC model, 4 intensity modulated radiation therapy (IMRT) plans specified by the AAPM TG 119 report were transferred to a computed tomography study of MapCHECK2, recalculated, and compared to measurements on a Varian accelerator. Both per-beam and composite-beam dose verification were conducted. Results: Through sufficient characterization of the MLC model, under 3%/2 mm and 2%/2 mm criteria, MapCHECK2 can be used to accurately verify per beam dose with gamma passing rate better than 90.9% and 89.3%, respectively, while the Gafchromic EBT3 films can achieve gamma passing rate better than 89.3% and 85.7%, respectively. Under the same criteria, MapCHECK2 can achieve composite beam dose verification with a gamma passing rate better than 95.9% and 90.3%, while the Gafchromic EBT3 films can achieve a gamma passing rate better than 96.1% and 91.8%; the p-value from the Mann Whitney test between gamma passing rates of the per beam dose verification using full MapCHECK2 package calibrated MLC model and film calibrated MLC model is .44 and .47, respectively; the p-value between those of the true composite beam dose verification is .62 and .36, respectively. Conclusion: It is confirmed that the 2-dimensional (2D) diode array MapCHECK2 can be used for data collection for MLC modeling with the combination of the ExpressMLC package of plans, whose doses are sufficient for the determination of MLC parameters. It could be a fitting alternative to films to boost the efficiency of MLC modeling and commissioning without sacrificing accuracy.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Fantasmas de Imagen , Rayos gamma , Radioterapia de Intensidad Modulada/métodos , Radiometría/métodos
5.
Nat Commun ; 15(1): 6749, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39117667

RESUMEN

Ingestible electronics have the capacity to transform our ability to effectively diagnose and potentially treat a broad set of conditions. Current applications could be significantly enhanced by addressing poor electrode-tissue contact, lack of navigation, short dwell time, and limited battery life. Here we report the development of an ingestible, battery-free, and tissue-adhering robotic interface (IngRI) for non-invasive and chronic electrostimulation of the gut, which addresses challenges associated with contact, navigation, retention, and powering (C-N-R-P) faced by existing ingestibles. We show that near-field inductive coupling operating near 13.56 MHz was sufficient to power and modulate the IngRI to deliver therapeutically relevant electrostimulation, which can be further enhanced by a bio-inspired, hydrogel-enabled adhesive interface. In swine models, we demonstrated the electrical interaction of IngRI with the gastric mucosa by recording conductive signaling from the subcutaneous space. We further observed changes in plasma ghrelin levels, the "hunger hormone," while IngRI was activated in vivo, demonstrating its clinical potential in regulating appetite and treating other endocrine conditions. The results of this study suggest that concepts inspired by soft and wireless skin-interfacing electronic devices can be applied to ingestible electronics with potential clinical applications for evaluating and treating gastrointestinal conditions.


Asunto(s)
Ghrelina , Animales , Porcinos , Ghrelina/metabolismo , Ghrelina/sangre , Robótica/instrumentación , Mucosa Gástrica/metabolismo , Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Femenino , Humanos , Suministros de Energía Eléctrica , Tracto Gastrointestinal , Electrodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA