Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 195
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Hepatol ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38636849

RESUMEN

BACKGROUND & AIMS: Ultrasonography (US) is recommended for HCC surveillance in high-risk patients but has limited performance in detecting early-stage HCC. We aimed to compare the diagnostic performance of biannual US and annual non-contrast abbreviated magnetic resonance imaging (NC-AMRI) as HCC surveillance modalities in high-risk patients. METHODS: This prospective, multicenter cohort study enrolled participants with an estimated annual risk of HCC greater than 5% between October 2015 and April 2017. Participants underwent six rounds of HCC surveillance at 6-month intervals, with both US and NC-AMRI at rounds 1, 3, and 5, and only US at rounds 2, 4, and 6. The sensitivity, diagnostic yield (DY), and false referral rate (FRR) for HCC detection by US and NC-AMRI were compared. RESULTS: In total, 208 participants underwent 980 US and 516 NC-AMRI examinations during 30 months of follow-up. Among them, 34 HCCs were diagnosed in 31 participants, with 20 (64.5%) classified as very early-stage and 11 (35.5%) as early-stage HCC. The sensitivity of annual NC-AMRI (71.0%, 22/31) was marginally higher than that of biannual US (45.2%, 14/31; p = 0.077). NC-AMRI showed a significantly higher DY than US (4.26% vs. 1.43%, p <0.001), with a similar FRR (2.91% vs. 3.06%, p = 0.885). A simulation of alternating US and NC-AMRI at 6-month intervals yielded a sensitivity of 83.9% (26/31), significantly exceeding that of biannual US (p = 0.006). CONCLUSIONS: Annual NC-AMRI showed a marginally higher sensitivity than biannual US for HCC detection in high-risk patients. The DY of annual NC-AMRI was significantly higher than that of biannual US, without increasing the FRR. Thus, alternating US and NC-AMRI at 6-month intervals could be an optimal surveillance strategy for high-risk patients. IMPACT AND IMPLICATIONS: Current guidelines permit the use of magnetic resonance imaging (MRI) as a surveillance tool for hepatocellular carcinoma in patients in whom ultrasonography (US) is inadequate. However, the specific indications, imaging sequences, and intervals for MRI surveillance remain unclear. In our study, we found that annual non-contrast abbreviated MRI exhibited marginally higher sensitivity and significantly better diagnostic yield than biannual US in patients at high risk of hepatocellular carcinoma. Alternating US and non-contrast abbreviated MRI at 6-month intervals led to significantly improved sensitivity compared to biannual US, making it a potentially optimal surveillance strategy for high-risk patients. GOV IDENTIFIER: NCT02551250.

2.
Am J Gastroenterol ; 119(6): 1117-1125, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38634559

RESUMEN

INTRODUCTION: Visceral obesity is a risk factor for reflux esophagitis (RE). We investigated the risk of RE according to visceral adipose tissue (VAT) measured by deep neural network architecture using computed tomography (CT) and evaluated the longitudinal association between abdominal adipose tissue changes and the disease course of RE. METHODS: Individuals receiving health checkups who underwent esophagogastroduodenoscopy (EGD) and abdominal CT at Seoul National University Healthcare System Gangnam Center between 2015 and 2016 were included. Visceral and subcutaneous adipose tissue areas and volumes were measured using a deep neural network architecture and CT. The association between the abdominal adipose tissue area and volume and the risk of RE was evaluated. Participants who underwent follow-up EGD and abdominal CT were selected; the effects of changes in abdominal adipose tissue area and volume on RE endoscopic grade were investigated using Cox proportional hazards regression. RESULTS: We enrolled 6,570 patients who underwent EGD and abdominal CT on the same day. RE was associated with male sex, hypertension, diabetes, excessive alcohol intake, current smoking status, and levels of physical activity. The VAT area and volume increased the risk of RE dose-dependently. A decreasing VAT volume was significantly associated with improvement in RE endoscopic grade (hazard ratio: 3.22, 95% confidence interval: 1.82-5.71). Changes in subcutaneous adipose tissue volume and the disease course of RE were not significantly correlated. DISCUSSION: Visceral obesity is strongly associated with RE. VAT volume reduction was prospectively associated with improvement in RE endoscopic grade dose-dependently. Visceral obesity is a potential target for RE treatment.


Asunto(s)
Endoscopía del Sistema Digestivo , Esofagitis Péptica , Grasa Intraabdominal , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Persona de Mediana Edad , Grasa Intraabdominal/diagnóstico por imagen , Grasa Intraabdominal/patología , Esofagitis Péptica/diagnóstico por imagen , Esofagitis Péptica/patología , Endoscopía del Sistema Digestivo/métodos , Factores de Riesgo , Adulto , Obesidad Abdominal/complicaciones , Obesidad Abdominal/diagnóstico por imagen , Redes Neurales de la Computación , Anciano , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
3.
Radiology ; 311(1): e233114, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38563667

RESUMEN

Background Noninvasive diagnostic guidelines for hepatocellular carcinoma (HCC) vary across different global geographic areas, especially regarding criteria about gadoxetic acid-enhanced MRI. Purpose To compare the diagnostic performance of four different international HCC diagnosis guidelines and readers' judgment in diagnosing HCC using gadoxetic acid-enhanced MRI in patients at high risk for HCC. Materials and Methods This retrospective study included patients who had not undergone treatment, were at risk for HCC, and who underwent gadoxetic acid-enhanced MRI from January 2015 to June 2018 from 11 tertiary hospitals in South Korea. Four radiologists independently reviewed focal liver lesions (FLLs) according to four guidelines: American Association for the Study of Liver Diseases (AASLD)/Liver Imaging Reporting and Data System (LI-RADS), Korean Liver Cancer Association-National Cancer Center (KLCA-NCC), European Association for the Study of the Liver (EASL), and Asian Pacific Association for the Study of the Liver (APASL). Reader judgment (HCC or not HCC) was also recorded. Malignant FLLs were confirmed at pathology, and histologic and clinical follow-up data were used for benign FLLs. The guidelines' diagnostic performance was compared using generalized estimating equations. Additionally, the diagnostic odds ratio was assessed. Results A total of 2445 FLLs (median size, 27.4 mm) were analyzed in 2237 patients (mean age, 59 years ± 11 [SD]; 1666 male patients); 69.3% (1694 of 2445) were HCCs. KLCA-NCC showed the highest accuracy (80.0%; 95% CI: 78.7, 81.2; P = .001), with high sensitivity in Eastern guidelines (APASL, 89.1% [95% CI: 87.8, 90.3]; KLCA-NCC, 78.2% [95% CI: 76.6, 79.7]) and high specificity in Western guidelines (AASLD/LI-RADS, 89.6% [95% CI: 87.8, 91.2]; EASL, 88.1% [95% CI: 86.2, 89.9]) (P = .001). The diagnostic odds ratios were 20.7 (95% CI: 17.0, 25.3) for AASLD/LI-RADS, 18.9 (95% CI: 15.8, 22.6) for KLCA-NCC, 16.8 (95% CI: 13.8, 20.4) for EASL, and 8.9 (95% CI: 7.4, 10.7) for APASL. The readers' judgment demonstrated higher accuracy than that of the guidelines (accuracy, 86.0%; 95% CI: 84.9, 86.9; P = .001). Conclusion Among four different international HCC diagnosis guidelines, Eastern guidelines demonstrated higher sensitivity, whereas Western guidelines displayed higher specificity. KLCA-NCC achieved the highest accuracy, and AASLD/LI-RADS exhibited the highest diagnostic odds ratio. © RSNA, 2024 Supplemental material is available for this article.


Asunto(s)
Carcinoma Hepatocelular , Gadolinio DTPA , Neoplasias Hepáticas , Humanos , Masculino , Persona de Mediana Edad , Carcinoma Hepatocelular/diagnóstico por imagen , Estudios Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética
4.
Eur Radiol ; 34(7): 4674-4685, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38114846

RESUMEN

OBJECTIVES: To identify MRI features for differentiating type 2 from type 1 intraductal papillary neoplasms of bile duct (IPNB) and assessing malignant potential of IPNB. METHODS: This retrospective study included 60 patients with surgically proven IPNB who had undergone preoperative MRI between January 2007 and December 2020. All surgical specimens were reviewed retrospectively to classify types 1 and 2 IPNBs and assess tumor grade. Significant MRI features for differentiating type 2 (n = 40) from type 1 IPNB (n = 20); and for IPNB with an associated invasive carcinoma (n = 43) from intraepithelial neoplasia (n = 17) were determined using logistic regression analysis. RESULTS: An associated invasive carcinoma was more frequently found in type 2 than in type 1 IPNB (85.0% [34/40] vs. 45.0% [9/20], p = 0.003). At univariable analysis, MRI features including extrahepatic location, no dilatation of tumor-bearing segment of bile duct, isolated upstream bile duct dilatation, and single lesion were associated with type 2 IPNB (all p ≤ 0.012). At multivariable analysis, significant MRI findings for differentiating type 2 from type 1 IPNB were extrahepatic location and no dilatation of tumor-bearing segment of bile duct (odds ratio [OR], 7.24 and 46.40, respectively). At univariable and multivariable analysis, tumor size ≥ 2.5 cm (OR, 8.45), bile duct wall thickening (OR, 4.82), and irregular polypoid or nodular tumor shape (OR, 6.44) were significant MRI features for differentiating IPNB with an associated invasive carcinoma from IPNB with intraepithelial neoplasia. CONCLUSION: MRI with MR cholangiopancreatography may be helpful in differentiating type 2 IPNB from type 1 IPNB and assessing malignant potential of IPNB. CLINICAL RELEVANCE STATEMENT: Preoperative MRI with MR cholangiopancreatography may be helpful in differentiating type 2 intraductal papillary neoplasms of bile duct (IPNB) from type 1 IPNB and assessing malignant potential of IPNB. KEY POINTS: • In terms of tumor grade, the incidence of invasive carcinoma was significantly higher in type 2 intraductal papillary neoplasm of the bile duct (IPNB) than in type 1 IPNB. • At MRI, extrahepatic location and no dilatation of tumor-bearing segment are significant features for differentiating type 2 IPNBs from type 1 IPNBs. • At MRI, large tumor size, bile duct wall thickening, and irregular polypoid or nodular tumor shape are significant features for differentiating IPNB with an associated invasive carcinoma from IPNB with intraepithelial neoplasia.


Asunto(s)
Neoplasias de los Conductos Biliares , Imagen por Resonancia Magnética , Humanos , Masculino , Femenino , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Neoplasias de los Conductos Biliares/diagnóstico por imagen , Neoplasias de los Conductos Biliares/patología , Persona de Mediana Edad , Anciano , Diagnóstico Diferencial , Adulto , Anciano de 80 o más Años
5.
Eur Radiol ; 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38492004

RESUMEN

OBJECTIVE: To investigate whether a deep learning (DL) controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-volumetric interpolated breath-hold examination (VIBE) technique can improve image quality, lesion conspicuity, and lesion detection compared to a standard CAIPIRINHA-VIBE technique in gadoxetic acid-enhanced liver MRI. METHODS: This retrospective single-center study included 168 patients who underwent gadoxetic acid-enhanced liver MRI at 3 T using both standard CAIPIRINHA-VIBE and DL CAIPIRINHA-VIBE techniques on pre-contrast and hepatobiliary phase (HBP) images. Additionally, high-resolution (HR) DL CAIPIRINHA-VIBE was obtained with 1-mm slice thickness on the HBP. Three abdominal radiologists independently assessed the image quality and lesion conspicuity of pre-contrast and HBP images. Statistical analyses involved the Wilcoxon signed-rank test for image quality assessment and the generalized estimation equation for lesion conspicuity and detection evaluation. RESULTS: DL and HR-DL CAIPIRINHA-VIBE demonstrated significantly improved overall image quality and reduced artifacts on pre-contrast and HBP images compared to standard CAIPIRINHA-VIBE (p < 0.001), with a shorter acquisition time (DL vs standard, 11 s vs 17 s). However, the former presented a more synthetic appearance (both p < 0.05). HR-DL CAIPIRINHA-VIBE showed superior lesion conspicuity to standard and DL CAIPIRINHA-VIBE on HBP images (p < 0.001). Moreover, HR-DL CAIPIRINHA-VIBE exhibited a significantly higher detection rate of small (< 2 cm) solid focal liver lesions (FLLs) on HBP images compared to standard CAIPIRINHA-VIBE (92.5% vs 87.4%; odds ratio = 1.83; p = 0.036). CONCLUSION: DL and HR-DL CAIPIRINHA-VIBE achieved superior image quality compared to standard CAIPIRINHA-VIBE. Additionally, HR-DL CAIPIRINHA-VIBE improved the lesion conspicuity and detection of small solid FLLs. DL and HR-DL CAIPIRINHA-VIBE hold the potential clinical utility for gadoxetic acid-enhanced liver MRI. CLINICAL RELEVANCE STATEMENT: DL and HR-DL CAIPIRINHA-VIBE hold promise as potential alternatives to standard CAIPIRINHA-VIBE in routine clinical liver MRI, improving the image quality and lesion conspicuity, enhancing the detection of small (< 2 cm) solid focal liver lesions, and reducing the acquisition time. KEY POINTS: • DL and HR-DL CAIPIRINHA-VIBE demonstrated improved overall image quality and reduced artifacts on pre-contrast and HBP images compared to standard CAIPIRINHA-VIBE, in addition to a shorter acquisition time. • DL and HR-DL CAIPIRINHA-VIBE yielded a more synthetic appearance than standard CAIPIRINHA-VIBE. • HR-DL CAIPIRINHA-VIBE showed improved lesion conspicuity than standard CAIPIRINHA-VIBE on HBP images, with a higher detection of small (< 2 cm) solid focal liver lesions.

6.
AJR Am J Roentgenol ; 222(2): e2330156, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37991335

RESUMEN

BACKGROUND. Contrast-enhanced ultrasound (CEUS) with perfluorobutane has used varying protocols and diagnostic criteria for hepatocellular carcinoma (HCC). OBJECTIVE. The purpose of this article was to assess diagnostic performance for HCC of CEUS with perfluorobutane in high-risk patients using various criteria. METHODS. This retrospective post hoc study evaluating individual patient data from three earlier prospective studies from one hospital included 204 patients (136 men, 68 women; mean age, 63 ± 11 [SD] years) at high risk of HCC with 213 liver observations. Patients underwent CEUS using perfluorobutane from March 2019 to June 2022. Three radiologists (the examination's operator and two subsequent reviewers) independently interpreted examinations, assessing arterial, portal venous (arterial phase completion through 2 minutes), transitional (2-5 minutes after injection), and Kupffer (≥ 10 minutes after injection) phase findings. Six criteria for HCC were tested: 1, any arterial phase hyperenhancement (APHE) with Kupffer phase hypoenhancement; 2, nonrim APHE with Kupffer phase hypoenhancement; 3, nonrim APHE with portal venous washout; 4, nonrim APHE with portal venous washout and/or Kupffer phase hypoenhancement; 5, nonrim APHE with portal venous and/or transitional washout; 6, nonrim APHE with any of portal venous washout, transitional washout, or Kupffer phase hypoenhancement. Depending on the criteria, observations were instead deemed to be a non-HCC malignancy if showing rim APHE, early washout (at < 1 minute), or marked washout (at 2 minutes). Reference was pathology for malignant observations and pathology or imaging follow-up for benign observations. Diagnostic performance was assessed, pooling readers' data. RESULTS. Criterion 1 (no recognized features of non-HCC malignancy) had highest sensitivity (86.9%) but lowest specificity (43.2%) for HCC. Compared with nonrim APHE and portal venous washout (criterion 3), the addition of Kupffer phase hypoenhancement (criterion 4), transitional washout (criterion 5), or either feature (criterion 6) significantly increased sensitivity (34.4% vs 62.6-64.2%) and accuracy (61.8% vs 75.1-76.5%), but significantly decreased specificity (98.5% vs 91.9-94.1%). Criteria 2, 4, 5, and 6 (all incorporating transitional washout and/or Kupffer phase hypoenhancement) showed no significant differences in sensitivity (62.6-64.2%), specificity (91.9-94.1%), or accuracy (75.1-76.5%). CONCLUSION. Recognition of features of non-HCC malignancy improved specificity for HCC. Incorporation of the findings of transitional washout and/or Kupffer phase hypoenhancement improved sensitivity and accuracy, albeit lowered specificity, versus arterial and portal venous findings alone, without further performance variation among criteria incorporating those two findings. CLINICAL IMPACT. Kupffer phase acquisition may be optional for observations classified as HCC or non-HCC malignancy by arterial, portal venous, and transitional phases.


Asunto(s)
Carcinoma Hepatocelular , Fluorocarburos , Neoplasias Hepáticas , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Estudios Retrospectivos , Estudios Prospectivos , Medios de Contraste , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad , Ultrasonografía/métodos
7.
Radiology ; 307(1): e221510, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36594835

RESUMEN

Background Quantitative US (QUS) using radiofrequency data analysis has been recently introduced for noninvasive evaluation of hepatic steatosis. Deep learning algorithms may improve the diagnostic performance of QUS for hepatic steatosis. Purpose To evaluate a two-dimensional (2D) convolutional neural network (CNN) algorithm using QUS parametric maps and B-mode images for diagnosis of hepatic steatosis, with the MRI-derived proton density fat fraction (PDFF) as the reference standard, in patients with nonalcoholic fatty liver disease (NAFLD). Materials and Methods: Consecutive adult participants with suspected NAFLD were prospectively enrolled at a single academic medical center from July 2020 to June 2021. Using radiofrequency data analysis, two QUS parameters (tissue attenuation imaging [TAI] and tissue scatter-distribution imaging [TSI]) were measured. On B-mode images, hepatic steatosis was graded using visual scoring (none, mild, moderate, or severe). Using B-mode images and two QUS parametric maps (TAI and TSI) as input data, the algorithm estimated the US fat fraction (USFF) as a percentage. The correlation between the USFF and MRI PDFF was evaluated using the Pearson correlation coefficient. The diagnostic performance of the USFF for hepatic steatosis (MRI PDFF ≥5%) was evaluated using receiver operating characteristic curve analysis and compared with that of TAI, TSI, and visual scoring. Results Overall, 173 participants (mean age, 51 years ± 14 [SD]; 96 men) were included, with 126 (73%) having hepatic steatosis (MRI PDFF ≥5%). USFF correlated strongly with MRI PDFF (Pearson r = 0.86, 95% CI: 0.82, 0.90; P < .001). For diagnosing hepatic steatosis (MRI PDFF ≥5%), the USFF yielded an area under the receiver operating characteristic curve of 0.97 (95% CI: 0.93, 0.99), higher than those of TAI, TSI, and visual scoring (P = .015, .006, and < .001, respectively), with a sensitivity of 90% (95% CI: 84, 95 [114 of 126]) and a specificity of 91% (95% CI: 80, 98 [43 of 47]) at a cutoff value of 5.7%. Conclusion A deep learning algorithm using quantitative US parametric maps and B-mode images accurately estimated the hepatic fat fraction and diagnosed hepatic steatosis in participants with nonalcoholic fatty liver disease. ClinicalTrials.gov registration nos. NCT04462562, NCT04180631 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Sidhu and Fang in this issue.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Adulto , Humanos , Masculino , Persona de Mediana Edad , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Redes Neurales de la Computación , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Estudios Prospectivos , Curva ROC
8.
Liver Transpl ; 29(5): 497-507, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36738083

RESUMEN

Several major transplantation centers have used composite multimodality evaluation for the preoperative evaluation of potential living liver donors. This approach can be time-consuming and, although rare, can cause complications. We aimed to demonstrate the clinical feasibility of our comprehensive preoperative MR protocol for the preoperative assessment of living liver donor candidates instead of composite multimodality evaluation. Thirty-five consecutive living liver donor candidates underwent multiphasic liver CT and comprehensive donor protocol MR examinations for preoperative evaluation in a single large-volume liver transplantation (LT) center. Three blinded abdominal radiologists reviewed the CT and MR images for vascular and biliary variations. The strength of agreement between CT and MR angiography was assessed using the kappa index. The detection rate of biliary anatomical variations was calculated. The sensitivity and specificity for detecting significant steatosis (>5%) were calculated. The estimated total volume and right lobe volumes measured by MR volumetry were compared with the corresponding CT volumetry measurements using the intraclass correlation coefficient (ICC). Among the 35 patients, 26 underwent LT. The measurement of agreement showed a moderate to substantial agreement between CT and MR angiography interpretations (kappa values, 0.47-0.79; p < 0.001). Combining T2-weighted and T1-weighted MR cholangiography techniques detected all biliary anatomical variations in 9 of the 26 patients. MR-proton density fat fraction showed a sensitivity of 100% (3/3) and a specificity of 91.3% (21/23) for detecting pathologically determined steatosis (>5%). MR volumetry reached an excellent agreement with CT volumetry (reviewers 1 and 2: ICC, 0.92; 95% CI, 0.84-0.96). Our one-stop comprehensive liver donor MR imaging protocol can provide complete information regarding hepatic vascular and biliary anatomies, hepatic parenchymal quality, and liver volume for living liver donor candidates and can replace composite multimodality evaluation.


Asunto(s)
Trasplante de Hígado , Humanos , Trasplante de Hígado/efectos adversos , Medios de Contraste , Imagen por Resonancia Magnética/métodos , Hígado/diagnóstico por imagen , Hígado/cirugía , Hígado/irrigación sanguínea , Donadores Vivos
9.
Eur Radiol ; 33(6): 4378-4388, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36512042

RESUMEN

OBJECTIVES: To evaluate the recall rate and performance of free-breathing T1W dynamic imaging in patients who underwent gadoxetic acid-enhanced liver MRI. METHODS: We retrospectively reviewed patients who underwent free-breathing dynamic T1WI liver MRI using Cartesian (XD-VIBE) or self-gated radial (SG-GRASP) sequences at two institutions. Four radiologists independently reviewed the overall image quality, streak, and motion artifacts for precontrast, arterial, and portal venous phases on a 4-point scale. Hepatic observations were annotated and assessed according to LI-RADS v2018. RESULTS: In total, 360 patients were included (XD-VIBE [n = 253], SG-GRASP [n = 107]). The overall image quality of free-breathing T1WI was 3.4 ± 0.4, 3.2 ± 0.4, and 3.5 ± 0.4 for precontrast, arterial, and portal venous phases, respectively. The actual recall rate was 0.6% (2/360). The SG-GRASP group showed fewer motion artifacts and more streak artifacts than the XD-VIBE group in all phases (p < 0.001 for all). The overall image quality was not significantly different between the two sequences in arterial (3.2 ± 0.4 in both, p = 0.607) and portal venous phases (3.5 ± 0.4 in XD-VIBE, 3.4 ± 0.4 in SG-GRASP, p = 0.214). Two sequences did not show significant differences in the lesion detection rate (figure of merit, FOM: 0.67 vs. 0.68, p = 0.876) or diagnostic performance for hepatocellular carcinoma (FOM: 0.55 vs. 0.62, p = 0.105). CONCLUSIONS: Both XD-VIBE and SG-GRASP provided sufficient image quality for patients at risk of developing motion artifacts, without significant differences in image quality or the lesion detection rate between sequences. KEY POINTS: • The overall image quality of free-breathing T1-weighted images using Cartesian or radial sequences was 3.4 ± 0.4, 3.2 ± 0.4, and 3.5 ± 0.4 for precontrast, arterial, and portal venous phases, respectively. • Only 0.3% (1/360) had undiagnostic exams and the actual recall rate was 0.6% (2/360) in patients who underwent free-breathing dynamic T1WI. • The overall lesion detection rate was 0.67 without a significant difference between Cartesian and radial sequences (figure of merit: 0.67 vs. 0.68, respectively, p = 0.876).


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Artefactos , Estudios Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagen , Medios de Contraste/farmacología , Imagen por Resonancia Magnética/métodos , Aumento de la Imagen/métodos
10.
Eur Radiol ; 33(6): 4344-4354, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36576547

RESUMEN

OBJECTIVE: Low monoenergetic images obtained using noise-reduction techniques may reduce CT contrast media requirements. We aimed to investigate the effectiveness of low-contrast-dose CT using dual-energy CT and deep learning-based denoising (DLD) techniques in patients at high risk of hepatocellular carcinoma (HCC). METHODS: We performed a prospective, randomized controlled noninferiority trial at a tertiary hospital between June 2019 and August 2020 (NCT04027556). Patients at high risk of HCC were randomly assigned (1:1) to the standard-contrast-dose group or low-contrast-dose group, which targeted a 40% reduction in contrast medium dose based on lean body weight. HCC conspicuity on arterial phase images was the primary endpoint with a noninferiority margin of 0.2. Images were independently assessed by three radiologists; model-based iterative reconstruction (MBIR) images of the standard-contrast-dose group and low monoenergetic (50-keV) DLD images of the low-contrast-dose group were compared using a generalized estimating equation. RESULTS: Ninety participants (age 59 ± 10 years; 68 men) were analyzed. Compared with the standard-contrast-dose group (n = 47), 40% less contrast media was used in the low-contrast-dose group (n = 43) (107.0 ± 17.1 mL vs. 64.5 ± 11.3 mL, p < 0.001). In the arterial phase, HCC conspicuity on 50-keV DLD images in the low-contrast-dose group was noninferior to that of MBIR images in the standard-contrast-dose group (2.92 vs. 2.56; difference, 0.36; 95% confidence interval, -0.13 to ∞; p = 0.013). CONCLUSIONS: The contrast dose in liver CT can be reduced by 40% without impairing HCC conspicuity when using 50-keV and DLD techniques. KEY POINTS: • In the arterial phase, hepatocellular carcinoma conspicuity on 50-keV deep learning-based denoising images in the low-contrast-dose group was noninferior to that of model-based iterative reconstruction images in the standard-contrast-dose group. • HCC detection was comparable between 50-keV deep learning-based denoising images in the low-contrast-dose group and model-based iterative reconstruction images in the standard-contrast-dose group.


Asunto(s)
Carcinoma Hepatocelular , Aprendizaje Profundo , Neoplasias Hepáticas , Masculino , Humanos , Persona de Mediana Edad , Anciano , Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Medios de Contraste , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Relación Señal-Ruido , Estudios Retrospectivos , Algoritmos
11.
Eur Radiol ; 33(5): 3660-3670, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36934202

RESUMEN

OBJECTIVE: To investigate the image quality and lesion conspicuity of a deep-learning-based contrast-boosting (DL-CB) algorithm on double-low-dose (DLD) CT of simultaneous reduction of radiation and contrast doses in participants at high-risk for hepatocellular carcinoma (HCC). METHODS: Participants were recruited and underwent four-phase dynamic CT (NCT04722120). They were randomly assigned to either standard-dose (SD) or DLD protocol. All CT images were initially reconstructed using iterative reconstruction, and the images of the DLD protocol were further processed using the DL-CB algorithm (DLD-DL). The primary endpoint was the contrast-to-noise ratio (CNR), the secondary endpoint was qualitative image quality (noise, hepatic lesion, and vessel conspicuity), and the tertiary endpoint was lesion detection rate. The t-test or repeated measures analysis of variance was used for analysis. RESULTS: Sixty-eight participants with 57 focal liver lesions were enrolled (20 with HCC and 37 with benign findings). The DLD protocol had a 19.8% lower radiation dose (DLP, 855.1 ± 254.8 mGy·cm vs. 713.3 ± 94.6 mGy·cm, p = .003) and 27% lower contrast dose (106.9 ± 15.0 mL vs. 77.9 ± 9.4 mL, p < .001) than the SD protocol. The comparative analysis demonstrated that CNR (p < .001) and portal vein conspicuity (p = .002) were significantly higher in the DLD-DL than in the SD protocol. There was no significant difference in lesion detection rate for all lesions (82.7% vs. 73.3%, p = .140) and HCCs (75.7% vs. 70.4%, p = .644) between the SD protocol and DLD-DL. CONCLUSIONS: DL-CB on double-low-dose CT provided improved CNR of the aorta and portal vein without significant impairment of the detection rate of HCC compared to the standard-dose acquisition, even in participants at high risk for HCC. KEY POINTS: • Deep-learning-based contrast-boosting algorithm on double-low-dose CT provided an improved contrast-to-noise ratio compared to standard-dose CT. • The detection rate of focal liver lesions was not significantly differed between standard-dose CT and a deep-learning-based contrast-boosting algorithm on double-low-dose CT. • Double-low-dose CT without a deep-learning algorithm presented lower CNR and worse image quality.


Asunto(s)
Carcinoma Hepatocelular , Aprendizaje Profundo , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Neoplasias Hepáticas/diagnóstico por imagen , Estudios Prospectivos , Método Doble Ciego , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
12.
Eur Radiol ; 33(12): 9152-9166, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37500964

RESUMEN

The 10th Global Forum for Liver Magnetic Resonance Imaging (MRI) was held as a virtual 2-day meeting in October 2021, attended by delegates from North and South America, Asia, Australia, and Europe. Most delegates were radiologists with experience in liver MRI, with representation also from specialists in liver surgery, oncology, and hepatology. Presentations, discussions, and working groups at the Forum focused on the following themes: • Gadoxetic acid in clinical practice: Eastern and Western perspectives on current uses and challenges in hepatocellular carcinoma (HCC) screening/surveillance, diagnosis, and management • Economics and outcomes of HCC imaging • Radiomics, artificial intelligence (AI) and deep learning (DL) applications of MRI in HCC. These themes are the subject of the current manuscript. A second manuscript discusses multidisciplinary tumor board perspectives: how to approach early-, mid-, and late-stage HCC management from the perspectives of a liver surgeon, interventional radiologist, and oncologist (Taouli et al, 2023). Delegates voted on consensus statements that were developed by working groups on these meeting themes. A consensus was considered to be reached if at least 80% of the voting delegates agreed on the statements. CLINICAL RELEVANCE STATEMENT: This review highlights the clinical applications of gadoxetic acid-enhanced MRI for liver cancer screening and diagnosis, as well as its cost-effectiveness and the applications of radiomics and AI in patients with liver cancer. KEY POINTS: • Interpretation of gadoxetic acid-enhanced MRI differs slightly between Eastern and Western guidelines, reflecting different regional requirements for sensitivity vs specificity. • Emerging data are encouraging for the cost-effectiveness of gadoxetic acid-enhanced MRI in HCC screening and diagnosis, but more studies are required. • Radiomics and artificial intelligence are likely, in the future, to contribute to the detection, staging, assessment of treatment response and prediction of prognosis of HCC-reducing the burden on radiologists and other specialists and supporting timely and targeted treatment for patients.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Inteligencia Artificial , Medios de Contraste , Gadolinio DTPA , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Sensibilidad y Especificidad , Estudios Retrospectivos
13.
Eur Radiol ; 33(12): 9167-9181, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37439935

RESUMEN

The 10th Global Forum for Liver Magnetic Resonance Imaging was held in October 2021. The themes of the presentations and discussions at this Forum are described in detail in the review by Taouli et al (2023). The focus of this second manuscript developed from the Forum is on multidisciplinary tumor board perspectives in hepatocellular carcinoma (HCC) management: how to approach early-, mid-, and late-stage management from the perspectives of a liver surgeon, an interventional radiologist, and an oncologist. The manuscript also includes a panel discussion by multidisciplinary experts on three selected cases that explore challenging aspects of HCC management. CLINICAL RELEVANCE STATEMENT: This review highlights the importance of a multidisciplinary team approach in liver cancer patients and includes the perspectives of a liver surgeon, an interventional radiologist, and an oncologist, including illustrative case studies. KEY POINTS: • A liver surgeon, interventional radiologist, and oncologist presented their perspectives on the treatment of early-, mid-, and late-stage HCC. • Different perspectives on HCC management between specialties emphasize the importance of multidisciplinary tumor boards. • A multidisciplinary faculty discussed challenging aspects of HCC management, as highlighted by three case studies.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/patología , Consenso , Medios de Contraste , Gadolinio DTPA , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Grupo de Atención al Paciente
14.
Int J Hyperthermia ; 40(1): 2235102, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37455021

RESUMEN

BACKGROUND: The novel separable clustered electrode system with two adjustable active tips (ICAEs) and a fine multipurpose needle (MPN) for in situ temperature monitoring and adjuvant agent injection was developed and validated in an animal study. The purpose of this study was to evaluate the technical efficacy and complication of the novel electrode system for patients who have small HCC. METHODS: In this prospective, single-center clinical trial, ten participants with 14 small (≤ 2 cm, BCLC 0-A) HCCs referred for RFA were enrolled. A novel electrode system consisting of two ICAEs and one MPN with a thermometer and side holes was used for RFA. The RF energy was delivered using a multichannel RF system combining bipolar and switching monopolar modes. Technical success, efficacy, and complications were evaluated on immediate and one-month follow-up CT. RESULTS: Technical success was achieved in 92.9% (13/14) of tumors. One participant withdrew consent after RFA, and technical efficacy was achieved in 91.7% (11/12) of tumors. None showed thermal injury to nontarget organs. All patients were discharged the day after RFA without major complications. The active electrode lengths were adjusted in 60% (6/10) of patients during the procedure to tailor the ablation zone (83.3%, n = 5) or treat two tumors with different sizes (16.7%, n = 1). MPN was capable of continuous temperature monitoring during all ablations (100%, 14/14). CONCLUSIONS: RFA using a novel electrode system showed acceptable technical efficacy and safety in patients with small HCCs. Further comparative studies are needed for the investigation of the system's potential benefits compared to conventional electrodes.


Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter , Neoplasias Hepáticas , Ablación por Radiofrecuencia , Animales , Humanos , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/patología , Ablación por Catéter/métodos , Electrodos , Estudios de Factibilidad , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Estudios Prospectivos , Resultado del Tratamiento
15.
Int J Hyperthermia ; 40(1): 2213424, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37253458

RESUMEN

Purpose: To investigate the feasibility rate and the mid-term outcomes of fusion imaging-guided radiofrequency ablation (RFA) with artificial ascites or pleural effusion of hepatocellular carcinomas (HCCs) based on tumor locations.Materials and Methods: In this single-center retrospective study, 456 patients with single HCCs ≤4 cm were referred for RFA from April 2019 to April 2020. The tumor locations were classified into a conventional location (CL) and difficult location (DL, close to the diaphragm/heart/major vessels/bile ducts/gastrointestinal tract/kidneys). This study assessed the feasibility rate of CT/MRI-US fusion system-guided RFA with artificial ascites or pleural effusion and the therapeutic outcomes including technical success, technique efficacy, and local tumor progression (LTP) according to tumor location. Cumulative LTP rates were estimated using the Kaplan-Meier method.Results: 235 of 456 (51.5%) patients had HCCs in DL. Ablation was feasible in 431 of 456 (94.5%) patients. The feasibility rate was significantly lower in DL group than in CL group (89.8% [211/235] vs. 99.5% [220/221], p < 0.001). The technical success and technique efficacy rates were 100% [211/211] vs. 99.5% [219/220] and 98.6% [208/211] vs. 100% [220/220] in DL and CL groups, respectively (p > 0.05). The estimated 1-, 2-, and 3-year cumulative LTP rates in DL group were 1.0%, 2.5%, and 2.5%, respectively, and were not significantly different from the 2.3%, 3.9%, and 3.9% observed in CL group (p = 0.456).Conclusion: Fusion imaging-guided RFA with artificial ascites or pleural effusion could decrease technically infeasible cases and provide comparable LTP rates for HCCs in DL to HCCs in CL.


Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter , Neoplasias Hepáticas , Derrame Pleural , Ablación por Radiofrecuencia , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Ascitis/diagnóstico por imagen , Ascitis/cirugía , Estudios Retrospectivos , Estudios de Factibilidad , Ablación por Catéter/métodos , Derrame Pleural/diagnóstico por imagen , Derrame Pleural/cirugía , Resultado del Tratamiento
16.
Radiology ; 302(1): 107-115, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34581625

RESUMEN

Background Diagnostic performance of the Liver Imaging Reporting and Data System tumor in vein (LR-TIV) category at CT and/or MRI has not yet been evaluated, to the knowledge of the authors. Purpose To assess the diagnostic performance of the LR-TIV category in detecting macroscopic tumors in veins (TIVs) at CT and hepatobiliary contrast agent-enhanced (HBA) MRI, with pathologic results used as the reference standard. Materials and Methods Between January 2010 and December 2019, consecutive patients with or without macroscopic TIV who underwent both CT and HBA MRI before hepatic resection or liver transplant were retrospectively included. Three radiologists independently assessed the LR-TIV features of enhancing soft tissue in vein and features suggestive of TIV (FSTIV) and reached a consensus. Macroscopic TIV at pathologic examination was the reference standard. Sensitivities and specificities of the LR-TIV category without and with FSTIV were calculated, and the added value of FSTIV was evaluated by using the McNemar test. Results In the 1322 patients with (n = 101) or without (n = 1221) macroscopic TIV (median age, 64 years [interquartile range, 58-70 years]; 1053 men), without consideration of FSTIV, the sensitivity and specificity of enhancing soft tissue in vein for detecting macroscopic TIV at pathologic examination were 64.4% (65 of 101) and 99.8% (1218 of 1221) with CT and 62.4% (63 of 101) and 99.8% (1218 of 1221) with HBA MRI, respectively. With consideration of FSTIV, the sensitivity and specificity of the LR-TIV category became 67.3% (68 of 101 patients) and 99.7% (1217 of 1221 patients) at both CT and HBA MRI. No difference was found between measurements without and with FSTIV (sensitivity, 62% vs 67% for CT [P = .45] and 64% vs 67% for HBA MRI [P = .18]; specificity, 99% for both CT and HBA MRI [P > .99 for both]). Conclusion The Liver Imaging Reporting and Data System tumor in vein category showed moderate sensitivity and high specificity in the detection of macroscopic tumors in veins at both CT and hepatobiliary contrast agent-enhanced MRI, with pathologic examination used as the reference standard. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Morrell in this issue.


Asunto(s)
Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Sistemas de Información Radiológica , Tomografía Computarizada por Rayos X/métodos , Neoplasias Vasculares/diagnóstico por imagen , Anciano , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Hígado/irrigación sanguínea , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
17.
J Magn Reson Imaging ; 56(6): 1757-1768, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35388939

RESUMEN

BACKGROUND: Pancreatobiliary MRI is often recommended for patients at risk of developing pancreas cancer. But the surveillance MRI protocol has not yet been widely accepted. PURPOSE: To establish an accelerated MRI protocol targeting the table time of 15 minutes for pancreatic cancer surveillance and test its performance in lesion characterization. STUDY TYPE: Prospective. POPULATION: A total of 30 participants were enrolled, who were undergoing follow-up care for intraductal papillary mucinous neoplasms or newly diagnosed pancreatic cysts (≥10 mm) and were scheduled for or had recently undergone contrast-enhanced CT (CECT). FIELD STRENGTH/SEQUENCE: A 3 T; heavily T2WI, 3D MRCP, DWI, dynamic T1WI, two-point Dixon. ASSESSMENT: In-room time and table time were measured. Seven radiologists independently reviewed image quality of MRI and then the presence of high-risk stigmata and worrisome features in addition to diagnostic confidence for accelerated MRI, CECT, and the noncontrast part of accelerated MRI (NC-MRI). STATISTICAL ANALYSIS: Fisher's exact test was used for categorical variables and either the Student's t-test or Mann-Whitney test was performed for continuous variables. The generalized estimated equation was used to compare the diagnostic performance of examinations on a per-patient basis. Interobserver agreement was evaluated via Fleiss kappa. A P value of <0.05 was considered to be statistically significant. RESULTS: The in-room time was 18.5 ± 2.6 minutes (range: 13.7-24.9) and the table time was 13.9 ± 1.9 minutes (range: 10.7-17.5). There was no significant difference between the diagnostic performances of the three examinations (pooled sensitivity: 75% for accelerated MRI and CECT, 68% for NC-MRI, P = 0.95), with the highest significant diagnostic confidence for accelerated MRI (4.2 ± 0.1). With accelerated MRI, the interobserver agreement was fair to excellent for high-risk stigmata (κ = 0.34-0.98). DATA CONCLUSION: Accelerated MRI protocol affords a table time of 15 minutes, making it potentially suitable for cancer surveillance in patients at risk of developing pancreatic cancer. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Carcinoma Ductal Pancreático/diagnóstico , Carcinoma Ductal Pancreático/patología , Estudios Prospectivos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/patología , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Neoplasias Pancreáticas
18.
Eur Radiol ; 32(9): 6407-6417, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35380228

RESUMEN

OBJECTIVES: To evaluate the diagnostic value of deep learning model (DLM) reconstructed dual-energy CT (DECT) low-keV virtual monoenergetic imaging (VMI) for assessing hypoenhancing hepatic metastases. METHODS: This retrospective study included 131 patients who underwent contrast-enhanced DECT (80-kVp and 150-kVp with a tin filter) in the portal venous phase for hepatic metastasis surveillance. Linearly blended images simulating 100-kVp images (100-kVp), standard 40-keV VMI images (40-keV VMI), and post-processed 40-keV VMI using a vendor-agnostic DLM (i.e., DLM 40-keV VMI) were reconstructed. Lesion conspicuity and diagnostic acceptability were assessed by three independent reviewers and compared using the Wilcoxon signed-rank test. The contrast-to-noise ratios (CNRs) were also measured placing ROIs in metastatic lesions and liver parenchyma. The detection performance of hepatic metastases was assessed by using a jackknife alternative free-response ROC method. The consensus by two independent radiologists was used as the reference standard. RESULTS: DLM 40-keV VMI, compared to 40-keV VMI and 100-kVp, showed a higher lesion-to-liver CNR (8.25 ± 3.23 vs. 6.05 ± 2.38 vs. 5.99 ± 2.00), better lesion conspicuity (4.3 (4.0-4.7) vs. 3.7 (3.7-4.0) vs. 3.7 (3.3-4.0)), and better diagnostic acceptability (4.3 (4.0-4.3) vs. 3.0 (2.7-3.3) vs. 4.0 (4.0-4.3)) (p < 0.001 for all). For lesion detection (246 hepatic metastases in 68 patients), the figure of merit was significantly higher with DLM 40-keV VMI than with 40-keV VMI (0.852 vs. 0.822, p = 0.012), whereas no significant difference existed between DLM 40-keV VMI and 100-kVp (0.852 vs. 0.842, p = 0.31). CONCLUSIONS: DLM 40-keV VMI provided better image quality and comparable diagnostic performance for detecting hypoenhancing hepatic metastases compared to linearly blended images. KEY POINTS: • DLM 40-keV VMI provides a superior image quality compared with 40-keV or 100-kVp for assessing hypoenhancing hepatic metastasis. • DLM 40-keV VMI has the highest CNR and lesion conspicuity score for hypoenhancing hepatic metastasis due to noise reduction and structural preservation. • DLM 40-keV VMI provides higher lesion detectability than standard 40-keV VMI (p = 0.012).


Asunto(s)
Aprendizaje Profundo , Neoplasias Hepáticas , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Estudios Retrospectivos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos
19.
Eur Radiol ; 32(1): 56-66, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34170366

RESUMEN

OBJECTIVES: To investigate clinical and CT factors associated with local resectability in patients with nonmetastatic pancreatic cancers after neoadjuvant chemotherapy ± radiation therapy (CRT). METHODS: This retrospective study included consecutive patients with nonmetastatic pancreatic cancers who underwent neoadjuvant CRT between June 2009 and June 2019. Tumor size, tumor-vascular contact with artery/vein, and local resectability categories (resectable, borderline resectable, or locally advanced) were assessed at baseline and post-CRT CT. Baseline and post-CRT carbohydrate antigen (CA) 19-9 levels were also assessed. Clinical or imaging features related to R0 resection were determined using logistic regression analysis. RESULTS: A total of 179 patients (mean age, 62.4 ± 9.3 years; 92 men) were included. After neoadjuvant CRT, 105 (58.7%) patients received R0 resection, while 74 (41.3%) did not. R0 resection rates were significantly different according to post-CRT CT resectability categories (p < 0.001): 82.8% (48/58), 70.1% (47/67), and 18.5% (10/54) for resectable, borderline resectable, and locally advanced disease, respectively. For post-CRT borderline resectable disease, ≥ 50% decrease in CA 19-9 was significantly associated with R0 resection (odds ratio (OR), 3.160; p = 0.02). For post-CRT locally advanced disease, small post-CRT tumor size ≤ 2 cm (OR, 9.668; p = 0.026) and decreased tumor-arterial contact (OR, 24.213; p = 0.022) were significantly associated with R0 resection. CONCLUSION: Post-CRT CT resectability categorization may be useful for the assessment of R0 resectability in patients with pancreatic cancer following neoadjuvant CRT. Additionally, ≥ 50% decrease in CA 19-9 was associated with R0 resection in post-CRT borderline resectable disease, while small post-CRT tumor size and decreased tumor-arterial contact were with locally advanced disease. KEY POINTS: • R0 resection rates following neoadjuvant chemotherapy ± radiation therapy (CRT) were 82.8%, 70.1%, and 18.5% in resectable, borderline resectable, and locally advanced disease, respectively, at post-CRT CT (p < 0.001). • For post-CRT borderline resectable disease, ≥ 50% decrease in carbohydrate antigen (CA) 19-9 was significantly associated with R0 resection. • For post-CRT locally advanced disease, small post-CRT tumor size ≤ 2 cm and decreased tumor-arterial contact were significantly associated with R0 resection.


Asunto(s)
Terapia Neoadyuvante , Neoplasias Pancreáticas , Anciano , Protocolos de Quimioterapia Combinada Antineoplásica , Biomarcadores de Tumor , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Neoplasias Pancreáticas/tratamiento farmacológico , Neoplasias Pancreáticas/terapia , Estudios Retrospectivos
20.
Eur Radiol ; 32(5): 2865-2874, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34821967

RESUMEN

OBJECTIVES: To compare the overall image quality and detectability of significant (malignant and pre-malignant) liver lesions of low-dose liver CT (LDCT, 33.3% dose) using deep learning denoising (DLD) to standard-dose CT (SDCT, 100% dose) using model-based iterative reconstruction (MBIR). METHODS: In this retrospective study, CT images of 80 patients with hepatic focal lesions were included. For noninferiority analysis of overall image quality, a margin of - 0.5 points (scored in a 5-point scale) for the difference between scan protocols was pre-defined. Other quantitative or qualitative image quality assessments were performed. Additionally, detectability of significant liver lesions was compared, with 64 pairs of CT, using the jackknife alternative free-response ROC analysis, with noninferior margin defined by the lower limit of 95% confidence interval (CI) of the difference of figure-of-merit less than - 0.1. RESULTS: The mean overall image quality scores with LDCT and SDCT were 3.77 ± 0.38 and 3.94 ± 0.34, respectively, demonstrating a difference of - 0.17 (95% CI: - 0.21 to - 0.12), which did not cross the predefined noninferiority margin of - 0.5. Furthermore, LDCT showed significantly superior quantitative results of liver lesion contrast to noise ratio (p < 0.05). However, although LDCT scored higher than the average score in qualitative image quality assessments, they were significantly lower than those of SDCT (p < 0.05). Figure-of-merit for lesion detection was 0.859 for LDCT and 0.878 for SDCT, showing noninferiority (difference: - 0.019, 95% CI: - 0.058 to 0.021). CONCLUSION: LDCT using DLD with 67% radiation dose reduction showed non-inferior overall image quality and lesion detectability, compared to SDCT. KEY POINTS: • Low-dose liver CT using deep learning denoising (DLD), at 67% dose reduction, provided non-inferior overall image quality compared to standard-dose CT using model-based iterative reconstruction (MBIR). • Low-dose CT using DLD showed significantly less noise and higher CNR lesion to liver than standard-dose CT using MBIR and demonstrated at least average image quality score among all readers, albeit with lower scores than standard-dose CT using MBIR. • Low-dose liver CT showed noninferior detectability for malignant and pre-malignant liver lesions, compared to standard-dose CT.


Asunto(s)
Aprendizaje Profundo , Neoplasias Hepáticas , Algoritmos , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA