Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Chem ; 95(18): 7186-7194, 2023 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-37103881

RESUMEN

The emergence of the coronavirus disease 2019 (COVID-19) pandemic prompted researchers to develop portable biosensing platforms, anticipating to detect the analyte in a label-free, direct, and simple manner, for deploying on site to prevent the spread of the infectious disease. Herein, we developed a facile wavelength-based SPR sensor built with the aid of a 3D printing technology and synthesized air-stable NIR-emitting perovskite nanocomposites as the light source. The simple synthesis processes for the perovskite quantum dots enabled low-cost and large-area production and good emission stability. The integration of the two technologies enabled the proposed SPR sensor to exhibit the characteristics of lightweight, compactness, and being without a plug, just fitting the requirements of on-site detection. Experimentally, the detection limit of the proposed NIR SPR biosensor for refractive index change reached the 10-6 RIU level, comparable with that of state-of-the-art portable SPR sensors. In addition, the bio-applicability of the platform was validated by incorporating a homemade high-affinity polyclonal antibody toward the SARS-CoV-2 spike protein. The results demonstrated that the proposed system was capable of discriminating between clinical swab samples collected from COVID-19 patients and healthy subjects because the used polyclonal antibody exhibited high specificity against SARS-CoV-2. Most importantly, the whole measurement process not only took less than 15 min but also needed no complex procedures or multiple reagents. We believe that the findings disclosed in this work can open an avenue in the field of on-site detection for highly pathogenic viruses.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Nanocompuestos , Humanos , Resonancia por Plasmón de Superficie/métodos , SARS-CoV-2 , COVID-19/diagnóstico , Técnicas Biosensibles/métodos , Anticuerpos
2.
J Nanosci Nanotechnol ; 17(2): 1076-082, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29676552

RESUMEN

Bulb-shaped field emission lamps (FELs) with a helical cathode filament were simulated and fabricated in this research. The light bulbs comprised a helical stainless steel filament cathode grown with carbon nano-coils (CNCs) and an Al anode deposited on the bottom hemisphere of a 60-mm-diameter glass bulb. White light was generated when the field-emitted electrons bombarded a layer of three-color phosphor coated on the anode. A numerical simulation model for the helical-cathode FELs was constructed, and the field emission (FE) performance was carefully studied. Due to the screening effect, the electric field strength as well as the FE current density on the inner side of the helix dramatically decreased with decreasing helical pitch. Real FELs using cathodes with various helical radii and pitches were fabricated and their FE currents were measured. The theoretical and experimental results were in good agreement. A maximum total FE current was found at a pitch of 16 mm (helical radius = 2 mm), where the optimum trade-off between a large total surface area and a small screening effect was obtained. The optimized FEL showed a total luminous flux of about 220 lm at an applied voltage of 8 kV and a color rendering index of 94. Compared to a straight filament cathode, a helical cathode offered a higher total FE current or, alternatively, a lower current density and a longer cathode life, if we fix the total current by using a lower voltage.

3.
J Nanosci Nanotechnol ; 11(3): 2315-20, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21449387

RESUMEN

A carbonyl iron/carbon fiber material consisting of carbon fibers grown on micrometer-sized carbonyl iron sphere, was synthesized by chemical vapor deposition using a mixture of C2H2 and H2. The hollow-core carbon fibers (outer diameter: 140 nm and inner diameter: 40 nm) were composed of well-ordered graphene layers which were almost parallel to the long axis of the fibers. A composite (2 mm thick) consisting of the carbonyl iron/carbon fibers and epoxy resin demonstrated excellent electromagnetic (EM) wave absorption. Minimum reflection losses of -36 dB (99.95% of EM wave absorption) at 7.6 GHz and -32 dB (99.92% of EM wave absorption) at 34.1 GHz were achieved. The well-dispersed and network-like carbon fibers in the resin matrix affected the dielectric loss of the EM wave while the carbonyl iron affected the magnetic loss.


Asunto(s)
Hierro/química , Nanotubos de Carbono/química , Nanotubos de Carbono/ultraestructura , Absorción , Cristalización/métodos , Campos Electromagnéticos , Ensayo de Materiales , Nanotecnología/métodos , Tamaño de la Partícula , Refractometría , Dispersión de Radiación
4.
Polymers (Basel) ; 13(18)2021 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-34577980

RESUMEN

In this study, the ballistic performance of armors composed of a polyurea elastomer/Kevlar fabric composite and a shear thickening fluid (STF) structure was investigated. The polyurea used was a reaction product of aromatic diphenylmethane isocyanate (A agent) and amine-terminated polyether resin (B agent). The A and B agents were diluted, mixed and brushed onto Kevlar fabric. After the reaction of A and B agents was complete, the polyurea/Kevlar composite was formed. STF structure was prepared through pouring the STF into a honeycomb paper panel. The ballistic tests were conducted with reference to NIJ 0101.06 Ballistic Test Specification Class II and Class IIIA, using 9 mm FMJ and 44 magnum bullets. The ballistic test results reveal that polyurea/Kevlar fabric composites offer better impact resistance than conventional Kevlar fabrics and a 2 mm STF structure could replace approximately 10 layers of Kevlar in a ballistic resistant layer. Our results also showed that a high-strength composite laminate using the best polyurea/Kevlar plates combined with the STF structure was more than 17% lighter and thinner than the conventional Kevlar laminate, indicating that the high-strength protective material developed in this study is superior to the traditional protective materials.

5.
Nanomaterials (Basel) ; 11(6)2021 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-34207195

RESUMEN

Corrosion prevention and infrared (IR) stealth are conflicting goals. While graphene nanosheets (GN) provide an excellent physical barrier against corrosive agent diffusion, thus lowering the permeability of anti-corrosion coatings, they have the side-effect of decreasing IR stealth. In this work, the anti-corrosion properties of 100-µm-thick composite epoxy coatings with various concentrations (0.01-1 wt.%) of GN fillers thermally reduced at different temperatures (300 °C, 700 °C, 1100 °C) are first compared. The performance was characterized by potentiodynamic polarization scanning, electrochemical impedance spectroscopy, water contact angle and salt spray tests. The corrosion resistance for coatings was found to be optimum at a very low filler concentration (0.05 wt.%). The corrosion current density was 4.57 × 10-11 A/cm2 for GN reduced at 1100 °C, showing no degradation after 500 h of salt-spray testing: a significant improvement over the anti-corrosion behavior of epoxy coatings. Further, to suppress the high IR thermal signature of GN and epoxy, Al was added to the optimized composite at different concentrations. The increased IR emissivity due to GN was not only eliminated but was in fact reduced relative to the pure epoxy. These optimized coatings of Al-GN-epoxy not only exhibited greatly reduced IR emissivity but also showed no sign of corrosion after 500 h of salt spray test.

6.
Polymers (Basel) ; 12(4)2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32244627

RESUMEN

We demonstrate a facile and effective method, which is low-cost and easy to scale up, to fabricate holey graphene nanosheets (HGNSs) via ultrafast heating during synthesis. Various heating temperatures are used to modify the material properties of HGNSs. First, we use HGNSs as the electrode active materials for electric double-layer capacitors (EDLCs). A synthesis temperature of 900 °C seems to be optimal, i.e., the conductivity and adhesion of HGNSs reach a compromise. The gravimetric capacitance of this HGNS sample (namely HGNS-900) is 56 F·g-1. However, the volumetric capacitance is low, which hinders its practical application. Secondly, we incorporate activated carbon (AC) into HGNS-900 to make a composite EDLC material. The effect of the AC:HGNS-900 ratio on the capacitance, high-rate performance, and cycling stability are systematically investigated. With a proper amount of HGNS-900, both the electrode gravimetric and volumetric capacitances at high rate charging/discharging are clearly higher than those of plain AC electrodes. The AC/HGNS-900 composite is a promising electrode material for nonaqueous EDLC applications.

7.
Sci Rep ; 5: 10976, 2015 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-26042359

RESUMEN

A field-emission light source with high luminance, excellent luminance uniformity, and tunable luminance characteristics with a novel lateral-gate structure is demonstrated. The lateral-gate triode structure comprises SiC nanowire emitters on a Ag cathode electrode and a pair of Ag gate electrodes placed laterally on both sides of the cathode. The simple and cost-effective screen printing technique is employed to pattern the lateral-gates and cathode structure on soda lime glass. The area coverage of the screen-printed cathode and gates on the glass substrate (area: 6 × 8 cm(2)) is in the range of 2.04% - 4.74% depending on the set of cathode-gate electrodes on the substrate. The lateral-gate structure with its small area coverage exhibits a two-dimensional luminance pattern with high brightness and good luminance uniformity. A maximum luminance of 10,952 cd/cm(2) and a luminance uniformity of >90% can be achieved with a gate voltage of 500 V and an anode voltage of 4000 V, with an anode current of 1.44 mA and current leakage to the gate from the cathode of about 10%.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA