Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Biol Chem ; 300(1): 105556, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38097188

RESUMEN

A renewable source of porcine macrophages derived from pluripotent stem cells (PSCs) would be a valuable alternative to primary porcine alveolar macrophages (PAMs) in the research of host-pathogen interaction mechanisms. We developed an efficient and rapid protocol, within 11 days, to derive macrophages from porcine PSCs (pPSCs). The pPSC-derived macrophages (pPSCdMs) exhibited molecular and functional characteristics of primary macrophages. The pPSCdMs showed macrophage-specific surface protein expression and macrophage-specific transcription factors, similar to PAMs. The pPSCdMs also exhibited the functional characteristics of macrophages, such as endocytosis, phagocytosis, porcine respiratory and reproductive syndrome virus infection and the response to lipopolysaccharide stimulation. Furthermore, we performed transcriptome sequencing of the whole differentiation process to track the fate transitions of porcine PSCs involved in the signaling pathway. The activation of transforming growth factor beta signaling was required for the formation of mesoderm and the inhibition of the transforming growth factor beta signaling pathway at the hematopoietic endothelium stage could enhance the fate transformation of hematopoiesis. In summary, we developed an efficient and rapid protocol to generate pPSCdMs that showed aspects of functional maturity comparable with PAMs. pPSCdMs could provide a broad prospect for the platforms of host-pathogen interaction mechanisms.


Asunto(s)
Macrófagos Alveolares , Células Madre Pluripotentes , Porcinos , Animales , Endocitosis , Hematopoyesis/efectos de los fármacos , Lipopolisacáridos/farmacología , Macrófagos Alveolares/citología , Macrófagos Alveolares/efectos de los fármacos , Macrófagos Alveolares/metabolismo , Macrófagos Alveolares/virología , Mesodermo/metabolismo , Células Madre Pluripotentes/citología , Células Madre Pluripotentes/efectos de los fármacos , Virus del Síndrome Respiratorio y Reproductivo Porcino/fisiología , Transducción de Señal/efectos de los fármacos , Porcinos/virología , Factores de Transcripción/metabolismo , Factor de Crecimiento Transformador beta/metabolismo , Factores de Tiempo
2.
FASEB J ; 38(4): e23481, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38334430

RESUMEN

Organoids are in vitro 3D models that are generated using stem cells to study organ development and regeneration. Despite the extensive research on lung organoids, there is limited information on pig lung cell generation or development. Here, we identified five epithelial cell types along with their characteristic markers using scRNA-seq. Additionally, we found that NKX2.1 and FOXA2 acted as the crucial core transcription factors in porcine lung development. The presence of SOX9/SOX2 double-positive cells was identified as a key marker for lung progenitor cells. The Monocle algorithm was used to create a pseudo-temporal differentiation trajectory of epithelial cells, leading to the identification of signaling pathways related to porcine lung development. Moreover, we established the differentiation method from porcine pluripotent stem cells (pPSCs) to SOX17+ FOXA2+ definitive endoderm (DE) and NKX2.1+ FOXA2+ CDX2- anterior foregut endoderm (AFE). The AFE is further differentiated into lung organoids while closely monitoring the differentiation process. We showed that NKX2.1 overexpression facilitated the induction of lung organoids and supported subsequent lung differentiation and maturation. This model offers valuable insights into studying the interaction patterns between cells and the signaling pathways during the development of the porcine lung.


Asunto(s)
Células Madre Pluripotentes , Animales , Porcinos , Pulmón/metabolismo , Organoides/metabolismo , Diferenciación Celular , Células Epiteliales/metabolismo
3.
FASEB J ; 38(10): e23668, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38742811

RESUMEN

Podocyte injury plays a critical role in the progression of diabetic kidney disease (DKD), but the underlying cellular and molecular mechanisms remain poorly understanding. MicroRNAs (miRNAs) can disrupt gene expression by inducing translation inhibition and mRNA degradation, and recent evidence has shown that miRNAs may play a key role in many kidney diseases. In this study, we identified miR-4645-3p by global transcriptome expression profiling as one of the major downregulated miRNAs in high glucose-cultured podocytes. Moreover, whether DKD patients or STZ-induced diabetic mice, expression of miR-4645-3p was also significantly decreased in kidney. In the podocytes cultured by normal glucose, inhibition of miR-4645-3p expression promoted mitochondrial damage and podocyte apoptosis. In the podocytes cultured by high glucose (30 mM glucose), overexpression of miR-4645-3p significantly attenuated mitochondrial dysfunction and podocyte apoptosis induced by high glucose. Furthermore, we found that miR-4645-3p exerted protective roles by targeting Cdk5 inhibition. In vitro, miR-4645-3p obviously antagonized podocyte injury by inhibiting overexpression of Cdk5. In vivo of diabetic mice, podocyte injury, proteinuria, and impaired renal function were all effectively ameliorated by treatment with exogenous miR-4645-3p. Collectively, these findings demonstrate that miR-4645-3p can attenuate podocyte injury and mitochondrial dysfunction in DKD by targeting Cdk5. Sustaining the expression of miR-4645-3p in podocytes may be a novel strategy to treat DKD.


Asunto(s)
Quinasa 5 Dependiente de la Ciclina , Diabetes Mellitus Experimental , Nefropatías Diabéticas , MicroARNs , Mitocondrias , Podocitos , Animales , Humanos , Masculino , Ratones , Apoptosis , Quinasa 5 Dependiente de la Ciclina/metabolismo , Quinasa 5 Dependiente de la Ciclina/genética , Diabetes Mellitus Experimental/metabolismo , Nefropatías Diabéticas/metabolismo , Nefropatías Diabéticas/patología , Nefropatías Diabéticas/genética , Glucosa , Ratones Endogámicos C57BL , MicroARNs/genética , MicroARNs/metabolismo , Mitocondrias/metabolismo , Podocitos/metabolismo , Podocitos/patología
4.
J Am Chem Soc ; 146(11): 7594-7604, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38462726

RESUMEN

The preservation of chirality during a transformation process, known as the "chiral memory" effect, has garnered significant attention across multiple research disciplines. Here, we first report the retention of the original chiral structure during dynamic covalent chemistry (DCC)-induced structural transformation from porous organic cages into covalent organic frameworks (COFs). A total of six two-dimensional chiral COFs constructed by entirely achiral building blocks were obtained through the DCC-induced substitution of chiral linkers in a homochiral cage (CC3-R or -S) using achiral amine monomers. Homochirality of these COFs resulted from the construction of 3-fold-symmetric benzene-1,3,5-methanimine cores with a propeller-like configuration of one single-handedness throughout the cage-to-COF transformation. The obtained chiral COFs can be further utilized as fluorescence sensors or chiral stationary phases for gas chromatography with high enantioselectivity. The present study thus highlighted the great potential to expand the scope of functional chiral materials via DCC-induced crystal-to-crystal transformation with the chiral memory effect.

5.
J Sep Sci ; 47(13): e2400073, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38965996

RESUMEN

Chirality is a fundamental property of nature. Separation and analysis of racemates are of great importance in the fields of medicine and the production of chiral biopharmaceutical intermediates. Chiral chromatography has the characteristics of a wide separation range, fast separation speed, and high efficiency. The development and preparation of novel chiral stationary phases with good chiral recognition and separation capacity is the core and key of chiral chromatographic separation and analysis. In this work, the representative research progress of novel chiral porous crystal materials including chiral covalent organic frameworks, chiral porous organic cages, chiral metal-organic frameworks, and chiral metal-organic cages used as chiral stationary phases of capillary gas chromatography and high-performance liquid chromatography over the last 4 years is reviewed in detail. The chiral recognition and separation properties of the representative studies in this review are also introduced and discussed.

6.
Mikrochim Acta ; 191(5): 281, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38649632

RESUMEN

Two chiral covalent organic frameworks (CCOFs) core-shell microspheres based on achiral organic precursors by chiral-induced synthesis strategy for HPLC enantioseparation are reported for the first time. Using n-hexane/isopropanol as mobile phase, various kinds of racemates were selected as analytes and separated on the CCOF-TpPa-1@SiO2 and CCOF-TpBD@SiO2-packed columns with a low column backpressure (3 ~ 9 bar). The fabricated two CCOFs@SiO2 chiral columns exhibited good separation performance towards various racemates with high column efficiency (e.g., 19,500 plates m-1 for (4-fluorophenyl)ethanol and 18,900 plates m-1 for 1-(4-chlorophenyl)ethanol) and good reproducibility. Some effects have been investigated such as the analyte mass and column temperature on the HPLC enantioseparation. Moreover, the chiral separation results of the CCOF-TpPa-1@SiO2 chiral column and the commercialized Chiralpak AD-H column show a good complementarity. This study demonstrates that the usage of chiral-induced synthesis strategy for preparing CCOFs core-shell microspheres as a novel stationary phase has a good application potential in HPLC.

7.
Mikrochim Acta ; 191(8): 445, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38958767

RESUMEN

A novel CCOF core-shell composite material (S)-DTP-COF@SiO2 was prepared via asymmetric catalytic and in situ growth strategy. The prepared (S)-DTP-COF@SiO2 was utilized as separation medium for HPLC enantioseparation using normal-phase and reversed-phase chromatographic modes, which displays excellent chiral separation performance for alcohols, esters, ketones, and epoxides, etc. Compared with chiral commercial chromatographic columns (Chiralpak AD-H and Chiralcel OD-H columns) and some previously reported chiral CCOF@SiO2 (CC-MP CCTF@SiO2 and MDI-ß-CD-modified COF@SiO2)-packed columns, there are 4, 3, 13, and 15 tested racemic compounds that could not be resolved on the Chiralpak AD-H column, Chiralcel OD-H column, CC-MP CCTF@SiO2 column, and MDI-ß-CD-modified COF@SiO2 column, respectively, which indicates that the resolution effect of (S)-DTP-COF@SiO2-packed column can be complementary to the other ones. The effects of the analyte mass, column temperature, and mobile phase composition on the enantiomeric separation were investigated. The chiral column exhibits good reproducibility after multiple consecutive injections. The RSDs (n = 5) of the peak area and retention time were less than 1.5% for repetitive separation of 2-methoxy-2-phenylethanol and 1-phenyl-1-pentanol. The chiral core-shell composite (S)-DTP-COF@SiO2 exhibited good enantiomeric separation performance, which not only demonstrates its potential as a novel CSP material in HPLC but also expands the range of applications for chiral COFs.

8.
J Am Chem Soc ; 145(34): 18956-18967, 2023 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-37596711

RESUMEN

The separation of enantiomers using high-performance chromatography technologies represents great importance and interest. In this aspect, ß-cyclodextrin (ß-CD) and its derivatives have been extensively studied as chiral stationary phases (CSPs). Nevertheless, ß-CD that was immobilized on a traditional matrix often exhibited low stabilities and limited operating ranges. Recently, covalent organic frameworks (COFs) with highly ordered nanopores are emerging as promising CSPs for enantioseparations, but their practical applications are still hampered by the difficulty of monomer and COF synthesis. Herein, two ß-CD-driven COFs are synthesized via a fast and facile plasma-induced polymerization combined postsynthesis modification strategy. The precisely defined COF channels enhanced the accessibility of the accommodated ß-CD to the analytes and acted as robust protective barriers to safeguard the ß-CD from harsh environments. Therefore, the ß-CD-modified COFs can be potentially general CSPs for extensive enantioseparation in both gas chromatography and high-performance liquid chromatography, and a wide range of racemates were separated. Compared to the commonly employed commercial chiral columns, these COF-based columns exhibited comparable resolution capability and superior application versatility. This work integrates the advantages and overcomes the defects of COFs and ß-CD, thus advancing COFs as platforms for chiral selector modification and giving great promise for practical chromatographic enantioseparation.

9.
Anal Chem ; 95(35): 13289-13296, 2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37615071

RESUMEN

Metallacycles are a novel class of supramolecular materials with circular structures, internal cavities, and abundant host-guest chemical properties that have exhibited good application prospects in many fields. However, to the best of our knowledge, no research on the use of metallacycles as stationary phases for gas chromatographic (GC) separations has been published yet. In this work, we report for the first time the use of a homochiral metallacycle, [ZnCl2L]2, as a stationary phase for GC separations. [ZnCl2L]2 was synthesized by reaction of (S)-(1-isonicotinoylpyrrolidin-2-yl)methyl-isonicotinate (L) with ZnCl2 via coordination-driven self-assembly. The [ZnCl2L]2-coated column displayed an excellent separation performance not only of organic isomers but also of racemic compounds. Sixteen racemates (including alcohols, esters, amino acid derivatives, ethers, organic acids, and epoxides) and 21 isomeric compounds (including positional, structural, and cis/trans-isomers) were well separated on the [ZnCl2L]2-coated column. Impressively, some racemates were resolved with high resolution values (Rs), including 1,2-butanediol diacetate (Rs = 25.86), ethyl 3-hydroxybutyrate (Rs = 20.97), 1,3-butanediol diacetate (Rs = 18.09), and threonine derivative (Rs = 18.61). Compared with the commercial ß-DEX 120 column for separation of the tested racemates, the [ZnCl2L]2-coated column exhibited good enantioseparation complementarity, enabling separation of some racemates that could not be separated, or were not well resolved, by the ß-DEX 120 column. In addition, many organic mixtures, such as n-alkanes, alkylbenzenes, n-alcohols, and a Grob test mixture, were also well separated on the [ZnCl2L]2-coated column. The column also has good reproducibility and thermal stability on separation. This work not only reveals the great potential of metallacycles for GC separations but also opens up a new application of metallacycles in separation science.

10.
J Sep Sci ; 46(18): e2300376, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37525411

RESUMEN

A chiral pillar[3]trianglimine (C60 H72 N6 O6 ) with a deep cavity has been developed as a chiral selector and bonded to thiolated silica by thiol-ene click reaction to fabricate a novel chiral stationary phase for enantioseparation in high-performance liquid chromatography. The enantioseparation performance of the fabricated chiral stationary phase has been evaluated by separating various racemic compounds, including alcohols, esters, amines, ketones, amino acids, and epoxides, in both normal-phase and reversed-phase elution modes. In total, 14 and 17 racemates have been effectively separated in these two separation modes, respectively. In comparison with two widely used chiral columns (Chiralcel OD-H and Chiralpak AD-H), our novel chiral stationary phase offered good chiral separation complementarity, separating some of the tested racemates that could not be separated or were only partially separated on these two commercial columns. The influences of analyte mass, mobile phase composition, and column temperature on chiral separation have been investigated. Good repeatability, stability, and column-to-column reproducibility of the chiral stationary phase for enantioseparation have been observed. After the fabricated column had been eluted up to 400 times, the relative standard deviations (n = 5) of resolution (Rs) and retention time of the separated analytes were < 0.39% and < 0.20%, respectively. The relative standard deviations (n = 3) of Rs and retention time for column-to-column reproducibility were < 4.6% and < 5.2%, respectively. This study demonstrated that the new chiral stationary phase has great prospects for chiral separation in high-performance liquid chromatography.

11.
Mikrochim Acta ; 190(6): 238, 2023 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-37222823

RESUMEN

The manufacturing of chiral covalent triazine framework core-shell microspheres CC-MP CCTF@SiO2 composite is reported as stationary phase for HPLC enantioseparation. The CC-MP CCTF@SiO2 core-shell microspheres were prepared by immobilizing chiral COF CC-MP CCTF constructed using cyanuric chloride and (S)-2-methylpiperazine on the surface of activated SiO2 through an in-situ growth approach. Various racemates as analytes were separated on the CC-MP CCTF@SiO2-packed column. The experimental results indicate that 19 pairs of enantiomers were well separated on the CC-MP CCTF@SiO2-packed column, including alcohols, phenols, amines, ketones, and organic acids. Among them, there are 17 pairs of enantiomers that can achieve baseline separation with good peak shapes. Their resolution values on this chiral column are between 0.4 and 5.61. The influences of analyte mass, column temperature, and composition of the mobile phase on the resolution of enantiomers were studied. In addition, the chiral resolution ability of CC-MP CCTF@SiO2-packed column was compared with the commercial chiral chromatographic columns (Chiralpak AD-H and Chiralcel OD-H columns) and some CCOF@SiO2 chiral columns (ß-CD-COF@SiO2, CTpBD@SiO2, and MDI-ß-CD-modified COF@SiO2). The CC-MP CCTF@SiO2-packed column exhibited some unique advantages and can complement these chiral columns in chiral separations. The research results show that the CC-MP CCTF@SiO2 chiral column offered high column efficiency (e.g., 17680 plates m-1 for ethyl mandelate), low column backpressure (5-9 bar), high enantioselectivity, and excellent chiral resolution ability for HPLC enantioseparation with good stability and reproducibility. The relative standard deviations (RSD) (n = 5) of the retention time, and peak areas by repeated separation of ethyl mandelate are 0.23% and 0.67%, respectively. It demonstrates that the CC-MP CCTF@SiO2 core-shell microsphere composite has great potential in enantiomeric separation by HPLC.

12.
Molecules ; 28(2)2023 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-36677719

RESUMEN

The chiral covalent-organic framework (CCOF) is a new kind of chiral porous material, which has been broadly applied in many fields owing to its high porosity, regular pores, and structural adjustability. However, conventional CCOF particles have the characteristics of irregular morphology and inhomogeneous particle size distribution, which lead to difficulties in fabricating chromatographic columns and high column backpressure when the pure CCOFs particles are directly used as the HPLC stationary phases. Herein, we used an in situ growth strategy to prepare core-shell composite by immobilizing MDI-ß-CD-modified COF on the surface of SiO2-NH2. The synthesized MDI-ß-CD-modified COF@SiO2 was utilized as a novel chiral stationary phase (CSP) to explore its enantiomeric-separation performance in HPLC. The separation of racemates and positional isomers on MDI-ß-CD-modified COF@SiO2-packed column (column A) utilizing n-hexane/isopropanol as the mobile phase was investigated. The results demonstrated that column A displayed remarkable separation ability for racemic compounds and positional isomers with good reproducibility and stability. By comparing the MDI-ß-CD-modified COF@SiO2-packed column (column A) with commercial Chiralpak AD-H column and the previously reported ß-CD-COF@SiO2-packed column (column B), the chiral recognition ability of column A can be complementary to that of Chiralpak AD-H column and column B. The relative standard deviations (RSDs) of the retention time and peak area for the separation of 1,2-bis(4-fluorophenyl)-2-hydroxyethanone were 0.28% and 0.79%, respectively. Hence, the synthesis of CCOFs@SiO2 core-shell composites as the CSPs for chromatographic separation has significant research potential and application prospects.

13.
Molecules ; 28(7)2023 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-37049997

RESUMEN

Porous organic cages (POCs) are a new subclass of porous materials, which are constructed from discrete cage molecules with permanent cavities via weak intermolecular forces. In this study, a novel chiral stationary phase (CSP) has been prepared by chemically binding a [4 + 6]-type chiral POC (C120H96N12O4) with thiol-functionalized silica gel using a thiol-ene click reaction and applied to HPLC separations. The column packed with this CSP presented good separation capability for chiral compounds and positional isomers. Thirteen racemates have been enantioseparated on this column, including alcohols, diols, ketones, amines, epoxides, and organic acids. Upon comparison with a previously reported chiral POC NC1-R-based column, commercial Chiralpak AD-H, and Chiralcel OD-H columns, this column is complementary to these three columns in terms of its enantiomeric separation; and can also separate some racemic compounds that cannot be separated by the three columns. In addition, eight positional isomers (iodoaniline, bromoaniline, chloroaniline, dibromobenzene, dichlorobenzene, toluidine, nitrobromobenzene, and nitroaniline) have also been separated. The influences of the injection weight and column temperature on separation have been explored. After the column has undergone multiple injections, the relative standard deviations (RSDs) for the retention time and selectivity were below 1.0 and 1.5%, respectively, indicating the good reproducibility and stability of the column for separation. This work demonstrates that POCs are promising materials for HPLC separation.

14.
J Am Chem Soc ; 144(2): 891-900, 2022 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-34989226

RESUMEN

High-performance liquid chromatography (HPLC) and gas chromatography (GC) over chiral stationary phases (CSPs) represent the most popular and highly applicable technology in the field of chiral separation, but there are currently no CSPs that can be used for both liquid and gas chromatography simultaneously. We demonstrate here that two olefin-linked covalent organic frameworks (COFs) featuring chiral crown ether groups can be general CSPs for extensive separation not only in GC but also in normal-phase and reversed-phase HPLC. Both COFs have the same 2D layered porous structure but channels of different sizes and display high stability under different chemical environments including water, organic solvents, acids, and bases. Chiral crown ethers are periodically aligned within the COF channels, allowing for enantioselective recognition of guest molecules through intermolecular interactions. The COF-packed HPLC and GC columns show excellent complementarity and each affords high resolution, selectivity, and durability for the separation of a wide range of racemic compounds, including amino acids, esters, lactones, amides, alcohols, aldehydes, ketones, and drugs. The resolution performances are comparable to and the versatility is superior to those of the most widely used commercial chiral columns, showing promises for practical applications. This work thus advances COFs with high stability as potential universal CSPs for chromatography that are otherwise hard or impossible to produce.

15.
Anal Chem ; 94(12): 4961-4969, 2022 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-35306818

RESUMEN

Porous organic cages (POCs) are an emerging class of porous materials that have aroused considerable research interest because of their unique characteristics, including good solubility and a well-defined intrinsic cavity. However, there have so far been no reports of chiral POCs as chiral stationary phases (CSPs) for enantioseparation by high-performance liquid chromatography (HPLC). Herein, we report the first immobilization of a chiral POC, NC1-R, on thiol-functionalized silica using a mild thiol-ene click reaction to prepare novel CSPs for HPLC. Two CSPs (CSP-1 and CSP-2) with different spacers have been prepared. CSP-1, with a cationic imidazolium spacer, exhibited excellent enantioselectivity for the resolution of various racemates. Twenty-three and 12 racemic compounds or chiral drugs were well enantioseparated on the CSP-1-packed column under normal-phase and reversed-phase conditions, respectively, including alcohols, diols, esters, ethers, ketones, epoxides, organic acids, and amines. In contrast, chiral resolution using CSP-2 (without a cationic imidazolium spacer)-packed column B was inferior to that of column A, demonstrating the important role of the cationic imidazolium spacer for chiral separation. The chiral separation capability of column A was also compared with that of two most popular commercial chiral columns, Chiralpak AD-H and Chiralcel OD-H, which exhibits good chiral recognition complementarity with the two commercial chiral columns. In addition, five positional isomers dinitrobenzene, nitroaniline, chloroaniline, bromoaniline, and iodoaniline were also well separated on column A. The effects of temperature, mobile phase composition, and injected analyte mass for separation on column A were investigated. Column A also showed good stability and reproducibility after repeated injections. This work demonstrates that chiral POCs are promising chiral materials for HPLC enantioseparation.


Asunto(s)
Química Clic , Compuestos de Sulfhidrilo , Aminas , Cationes , Cromatografía Líquida de Alta Presión/métodos , Porosidad , Reproducibilidad de los Resultados , Estereoisomerismo , Compuestos de Sulfhidrilo/química
16.
Plant Biotechnol J ; 20(2): 335-349, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34582620

RESUMEN

Necrotrophic fungus Rhizoctonia solani Kühn (R. solani) causes serious diseases in many crops worldwide, including rice and maize sheath blight (ShB). Crop resistance to the fungus is a quantitative trait and resistance mechanism remains largely unknown, severely hindering the progress on developing resistant varieties. In this study, we found that resistant variety YSBR1 has apparently stronger ability to suppress the expansion of R. solani than susceptible Lemont in both field and growth chamber conditions. Comparison of transcriptomic profiles shows that the photosynthetic system including chlorophyll biosynthesis is highly suppressed by R. solani in Lemont but weakly in YSBR1. YSBR1 shows higher chlorophyll content than that of Lemont, and inducing chlorophyll degradation by dark treatment significantly reduces its resistance. Furthermore, three rice mutants and one maize mutant that carry impaired chlorophyll biosynthesis all display enhanced susceptibility to R. solani. Overexpression of OsNYC3, a chlorophyll degradation gene apparently induced expression by R. solani infection, significantly enhanced ShB susceptibility in a high-yield ShB-susceptible variety '9522'. However, silencing its transcription apparently improves ShB resistance without compromising agronomic traits or yield in field tests. Interestingly, altering chlorophyll content does not affect rice resistance to blight and blast diseases, caused by biotrophic and hemi-biotrophic pathogens, respectively. Our study reveals that chlorophyll plays an important role in ShB resistance and suppressing chlorophyll degradation induced by R. solani infection apparently improves rice ShB resistance. This discovery provides a novel target for developing resistant crop to necrotrophic fungus R. solani.


Asunto(s)
Oryza , Clorofila , Oryza/genética , Oryza/microbiología , Enfermedades de las Plantas/genética , Enfermedades de las Plantas/microbiología , Rhizoctonia
17.
Chirality ; 34(3): 462-472, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35060196

RESUMEN

Chiral covalent organic framework materials have many excellent properties, which have received much attention in the field of separation. Synthesized the covalent organic framework COF-TpBD (NH2 )2 modified, respectively, by L-valine trifluoroacetyl derivative, L-hydroxyproline, and (1S)-(+)-10-camphorsulfonyl chloride, three capillary columns of chiral covalent organic framework materials were obtained for gas chromatography. Those columns are able to separate some chiral compounds, positional isomers, n-alkanes, n-alcohols, aromatic hydrocarbon mixture, and Grob's reagents. They are complementary to other chiral capillary columns and are possible for potential applications.


Asunto(s)
Estructuras Metalorgánicas , Alcoholes , Cromatografía de Gases/métodos , Isomerismo , Estructuras Metalorgánicas/química , Estereoisomerismo
18.
J Sep Sci ; 45(1): 51-77, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34729907

RESUMEN

Separations and analyses of chiral compounds are important in many fields, including pharmaceutical production, preparation of chemical intermediates, and biochemistry. High-performance liquid chromatography using a chiral stationary phase is regarded as one of the most valuable methods for enantiomeric separation and analysis because it is highly efficient, is broadly applicable, and has powerful separation capability. The focus for development of this method is the identification of novel chiral stationary phases with superior recognition performance and good stability. The present article reviews recent progress in the development of new chiral stationary phases for high-performance liquid chromatography between January 2018 and June 2021. These newly reported chiral stationary phases are divided into three categories: small organic molecule-based (cyclodextrin and its derivatives, macrocyclic antibiotics, cinchona alkaloids, and other low molecular weight chiral molecules), macromolecule-based (cellulose and amylose derivatives, chitin and chitosan derivatives, and synthetic helical polymers) and chiral porous material-based (chiral metal-organic frameworks, chiral covalent organic frameworks, and chiral inorganic mesoporous silicas). Each type of chiral stationary phase is discussed in detail.

19.
J Sep Sci ; 45(18): 3510-3519, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35880615

RESUMEN

Chiral metal-organic frameworks have shown great potential in enantioselective separation and asymmetric catalysis due to their diverse and adjustable structures with abundant chiral recognition sites. Herein, a new chiral post-synthetic modification was used for preparing an achiral@chiral metal-organic frameworks core-shell composite [Cu3 (Btc)2 ]@[Cu2 ((+)-Cam)2 Dabco] by a superficial chiral etching method. The [Cu3 (Btc)2 ]@[Cu2 ((+)-Cam)2 Dabco] composite was utilized as a novel chiral stationary phase for HPLC enantioseparation. Various racemates were separated on the [Cu3 (Btc)2 ]@[Cu2 ((+)-Cam)2 Dabco]-packed column (column A). It exhibited good chiral resolving ability toward many different kinds of racemates, especially chiral drugs. Among them, the highest resolution value for 1,2-diphenyl-1,2-ethanediol reaches 2.70. The relative standard deviations of retention time and peak area for repeated separation of 1,2-diphenyl-1,2-ethanol were 0.45% and 0.81%, respectively. Compared with the resolution ability of [Cu2 ((+)-Cam)2 Dabco]-packed column (column B), column A shows higher column efficiency and better separation performance than those of column B. The results indicated that the [Cu3 (Btc)2 ]@[Cu2 ((+)-Cam)2 Dabco] as a stationary phase can greatly improve the column efficiency and chiral resolution ability of chiral metal-organic frameworks, which demonstrated that the superficial chiral etching as an economic and efficient strategy opens up a new way for the application of metal-organic frameworks.


Asunto(s)
Estructuras Metalorgánicas , Compuestos de Bifenilo , Cromatografía Líquida de Alta Presión/métodos , Etanol , Glicol de Etileno , Estructuras Metalorgánicas/química , Estereoisomerismo
20.
Mikrochim Acta ; 189(9): 360, 2022 08 30.
Artículo en Inglés | MEDLINE | ID: mdl-36042107

RESUMEN

A spherical chiral porous organic polymer (POPs) COP-1 is synthesized by the Friedel-Crafts alkylation reaction of Boc-3-(4-biphenyl)-L-alanine (BBLA) and 4,4'-bis(chloromethyl)-1,1'-biphenyl (BCMBP), which was used as a novel chiral stationary phase (CSPs) for mixed-mode high-performance liquid chromatography (HPLC) enantioseparation. The racemic compounds were resolved in normal-phase liquid chromatography (NPLC) using n-hexane/isopropanol as mobile phase and reversed-phase liquid chromatography (RPLC) using methanol/water as mobile phase. The COP-1-packed column exhibited excellent separation performance toward various racemic compounds including alcohols, amines, ketones, esters, epoxy compounds, organic acids, and amino acids in NPLC and RPLC modes. The effects of analyte mass and column temperature on the separation efficiency of racemic compounds were investigated. In addition, the chiral resolution ability of the COP-1-packed column not only can be complementary in RPLC/NPLC modes but also exhibit a good chiral recognition complementarity with Chiralpak AD-H column and chiral porous organic cage (POC) NC1-R column. The relative standard deviations (RSD) (n = 5) of the retention time, resolution value, and peak area by repeated separation of 1-(4-chiorophenyl)ethanol are all below 3.0%. The COP-1 column shows high column efficiency (e.g., 17,320 plates m-1 for 1-(4-chlorophenyl)ethanol on COP-1 column in NPLC), high enantioselectivity, and good reproducibility toward various racemates. This work demonstrates that chiral POPs microspheres are promising chiral materials for HPLC enantioseparation.


Asunto(s)
Aminas , Polímeros , Cromatografía Líquida de Alta Presión/métodos , Etanol , Porosidad , Reproducibilidad de los Resultados , Estereoisomerismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA