RESUMEN
Nowadays, continuous efforts have been devoted to designing stable and high-efficiency electrochemiluminescence (ECL) emitters as alternatives for tris(2,2'-bipyridine)-ruthenium(II) (Ru(bpy)32+) in medical research. Herein, a novel ECL emitter was obtained by coordinating crystalline covalent triazinyl frameworks (cCTFs) with Ru2+ (termed Ru-cCTFs), which exhibited strong ECL emission by the ligand to metal charge transfer (LMCT) route. After its integration with 4-mercaptopyridine (SH-Py), the resultant SH-Py-Ru-cCTFs achieved 2.3-fold enhancement in the ECL efficiency by employing Ru(bpy)32+ as a standard, which involved a dynamic "intrarticular radical annihilation" ECL pathway. On such foundation, an automated ECL (A-ECL) aptasensor was constructed with an "on-off-on" model and magnetic separation upon linkage of the SH-Py-Ru-cCTFs with streptavidin (SA) magnetic beads (MBs). This automatic assay of miRNA-182 showed a wider linear range from 1.0 to 100.0 fM with a correlation coefficient (R2) of 0.994, a lower limit of detection (LOD) down to 0.28 fM, and faster operation within 41 min. Impressively, this bioassay facilely distinguished the stages of glioma disease from clinical blood samples with high accuracy. Hence, this research sheds light on how to develop advanced ECL luminophores and an automatic method, showing substantial insights into pathogenesis research of gliomas.
Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Glioma , Mediciones Luminiscentes , Humanos , Técnicas Biosensibles/métodos , Aptámeros de Nucleótidos/química , Automatización , Límite de Detección , Compuestos Organometálicos/química , Estructuras Metalorgánicas/químicaRESUMEN
Nowadays, signal enhancement is imperative to increase sensitivity of advanced ECL devices for expediting their promising applications in clinic. In this work, photodynamic-assisted electrochemiluminescence (PDECL) device was constructed for precision diagnosis of Parkinson, where an advanced emitter was prepared by electrostatically linking 2,6-dimethyl-8-(3-carboxyphenyl)4,4'-difluoroboradiazene (BET) with 1-butyl-3-methylimidazole tetrafluoroborate ([BMIm][BF4]). Specifically, protoporphyrin IX (PPIX) can trigger the photodynamic reaction under light irradiation with a wavelength of 450 nm to generate lots of singlet oxygen (1O2), showing a 2.43-fold magnification in the ECL responses. Then, the aptamer (Apt) was assembled on the functional BET-[BMIm] for constructing a "signal off" ECL biosensor. Later on, the PPIX was embedded into the G-quadruplex (G4) of the Apt to magnify the ECL signals for bioanalysis of α-synuclein (α-syn) under light excitation. In the optimized surroundings, the resulting PDECL sensor has a broad linear range of 100.0 aM â¼ 10.0 fM and a low limit of detection (LOD) of 63 aM, coupled by differentiating Parkinson patients from normal individuals according to the receiver operating characteristic (ROC) curve analysis of actual blood samples. Such research holds great promise for synthesis of other advanced luminophores, combined with achieving an early clinical diagnosis.
Asunto(s)
Compuestos de Boro , Técnicas Electroquímicas , Mediciones Luminiscentes , Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/diagnóstico , Enfermedad de Parkinson/sangre , Compuestos de Boro/química , Técnicas Biosensibles/métodos , alfa-Sinucleína/análisis , alfa-Sinucleína/sangre , Protoporfirinas/química , Aptámeros de Nucleótidos/química , Límite de DetecciónRESUMEN
Nowadays, organic emitters suffer from insufficient electrochemiluminescence (ECL) efficiency in aqueous solutions, and their practical applications are severely restricted in the bio-sensing field. In this work, palladium nanospheres-embedded metal-organic frameworks (Pd@MOFs) were exploited to enhance the ECL efficiency of 2,6-dimethyl-8-(3-carboxyphenyl)4,4'-difluoroboradiazene (BET) prepared by a one-pot method in aqueous environment. First, the Pd@MOFs were generated via in situ reduction of Pd nanospheres anchored onto the MOFs, and fabricated by orderly coordination of palladium chloride (PdCl2) with 1,2,4,5-benzenetetramine (BTA) tetrahydrochloride. Then, the influence of protons on the ECL response of BET was studied in detail to obtain stronger ECL emission using potassium persulfate (K2S2O8) as co-reactant in aqueous environment. As a result, a 1.47-fold ECL efficiency enlargement of BET/K2S2O8 was harvested at the Pd@MOFs/GCE, where Ru(bpy)32+ behaved as a standard. Based on the fact that the ECL signals of the BET-covered Pd@MOFs modified glassy carbon electrode (simplified as BET/Pd@MOFs/GCE) can be quenched by Cu2+, the as-built ECL sensor showed a wide linear range (1.0-100.0 pM) and a limit of detection (LOD) as low as 0.12 pM. Hence, such research offers huge potential to promote the development of organic emitters in ECL biosensors and environmental monitoring.
RESUMEN
Accurate intracellular cholesterol traffic plays crucial roles. Niemann Pick type C (NPC) proteins NPC1 and NPC2, are two lysosomal cholesterol transporters that mediate the cholesterol exit from lysosomes. However, other proteins involved in this process remain poorly defined. Here, we find that the previously unannotated protein TMEM241 is required for cholesterol egressing from lysosomes through amphotericin B-based genome-wide CRISPR-Cas9 KO screening. Ablation of TMEM241 caused impaired sorting of NPC2, a protein utilizes the mannose-6-phosphate (M6P) modification for lysosomal targeting, resulting in cholesterol accumulation in the lysosomes. TMEM241 is a member of solute transporters 35 nucleotide sugar transporters family and localizes on the cis-Golgi network. Our data indicate that TMEM241 transports UDP-N-acetylglucosamine (UDP-GlcNAc) into Golgi lumen and UDP-GlcNAc is used for the M6P modification of proteins including NPC2. Furthermore, Tmem241-deficient mice display cholesterol accumulation in pulmonary cells and behave pulmonary injury and hypokinesia. Taken together, we demonstrate that TMEM241 is a Golgi-localized UDP-GlcNAc transporter and loss of TMEM241 causes cholesterol accumulation in lysosomes because of the impaired M6P-dependent lysosomal targeting of NPC2.
Asunto(s)
Colesterol , Proteínas de Transporte Vesicular , Animales , Ratones , Proteínas de Transporte Vesicular/metabolismo , Colesterol/metabolismo , Uridina Difosfato/metabolismo , Lisosomas/metabolismoRESUMEN
Electrochemiluminescence (ECL) has attracted significant interest in the analysis of cancer cells, where the ruthenium(II)-based emitter demonstrates urgency and feasibility to improve the ECL efficiency. In this work, the self-enhanced ECL luminophore was prepared by covalent anchoring of Pd nanoclusters on aminated metal organic frameworks (Pd NCs@MOFs), followed by linkage with bis(2,2'-bipyridine)-5-amino-1,10-phenanthroline ruthenium(II) (RuP). The resultant luminophore showed 214-fold self-magnification in the ECL efficiency over RuP alone, combined by promoting the interfacial photoelectron transfer. The enhanced mechanism through ion annihilation was critically proved by controlled experiments and density functional theory (DFT) calculations. Based on the above, a "signal off" ECL biosensor was built by assembly of tyrosine kinase 7 (PTK-7) aptamer (Apt) on the established sensing platform for analysis of human lung cancer cells (A549). The built sensor showed a lower detection limit of 8 cells mL-1, achieving the single-cell detection. This work reported a self-enhanced strategy for synthesis of advanced ECL emitters, combined by exploring the ECL biosensing devices in the single-cell analysis of cancers.
Asunto(s)
Técnicas Biosensibles , Neoplasias Pulmonares , Nanopartículas del Metal , Estructuras Metalorgánicas , Rutenio , Humanos , Mediciones Luminiscentes , Técnicas Electroquímicas , Límite de DetecciónRESUMEN
Nowadays, electrochemiluminescence (ECL) efficiency of an organic emitter is closely related with its potential applications in food safety and environmental monitoring fields. In this work, 2,4,6-tris(4-carboxyphenyl)-1,3,5-triazine (TATB) was self-assembled to form hydrogen bond organic frameworks (HOFs), which worked as ideal reactors to generate highly active oxygen-containing radicals, followed by linking with isoluminol (ILu) via amide bond (termed ILu-HOFs). After covalent assembly with aminated indium-tin oxide electrode (labeled NH2-ITO), the ECL efficiency of the ILu-HOFs NH2-ITO showed about a 23.4-time increase over that of ILu itself in the presence of H2O2. Meanwhile, the enhanced ECL mechanism was mainly studied by electron paramagnetic resonance, theoretical calculation, and electrochemistry. On the above foundation, an aptamer "sandwich" ECL biosensor was constructed for detecting isocarbophos (ICP) via in situ elimination of H2O2 with catalase-linked palladium nanocubes (CAT-Pd NCs). The as-built sensor showed a broad linear range (1 pM to 100 nM) and a low limit of detection (LOD) down to 0.4 pM, coupled with efficient assays of ICP in lake water and cucumber juice samples. This strategy provides an effective way for the synthesis of advanced ECL emitter, coupled by showing promising applications in environmental and food analysis.
Asunto(s)
Técnicas Biosensibles , Peróxido de Hidrógeno , Enlace de Hidrógeno , Mediciones Luminiscentes , Límite de Detección , Electrodos , Técnicas ElectroquímicasRESUMEN
Nowadays, aggregation quenching of most organic photosensitizers in aqueous media seriously restricts analytical and biomedical applications of photoelectrochemical (PEC) sensors. In this work, an aggregation-enhanced PEC photosensitizer was prepared by electrostatically bonding protoporphyrin IX (PPIX) with an ionic liquid of 1-butyl-3-methylimidazole tetrafluoroborate ([BMIm][BF4]), termed as PPIX-[BMIm] for clarity. The resultant PPIX-[BMIm] showed weak photocurrent in pure dimethyl sulfoxide (DMSO, good solvent), while the PEC signals displayed a 44.1-fold enhancement in a water (poor solvent)/DMSO binary solvent with a water fraction (fw) of 90%. Such PEC-enhanced mechanism was critically studied by electrochemistry and density functional theory (DFT) calculation in some detail. Afterward, a label-free PEC cytosensor was built for ultrasensitive bioassay of acute lymphoblastic leukemia (molt-4) cells by electrodepositing Au nanoparticles (Au NPs) on the PPIX-[BMIm] aggregates and sequential assembly of protein tyrosine kinase (PTK) aptamer DNA (aptDNA). The resultant cytosensor showed a wide linear range (300 to 3 × 105 cells mL-1) with a limit of detection (LOD) as low as 63 cells mL-1. The aggregation-enhanced PEC performance offers a valuable and practical pathway for synthesis of advanced organic photosensitizer to explore its PEC applications in early diagnosis of tumors.
Asunto(s)
Técnicas Biosensibles , Líquidos Iónicos , Nanopartículas del Metal , Técnicas Electroquímicas , Oro , Fármacos Fotosensibilizantes , Protoporfirinas , Electricidad EstáticaRESUMEN
In the area of public safety and crime prevention, some research based on deep learning has achieved success in the detection of prohibited items for x-ray security inspection. However, the number of parameters and computational consumption of most object detection methods based on deep learning are huge, which makes the hardware requirements of these methods extremely high and limits their applications. In this paper, a lightweight prohibited item detection method based on YOLOV4 is proposed for x-ray security inspection. First, the MobilenetV3 is used to replace the backbone network of YOLOV4, and the depthwise separable convolution is used to optimize the neck and head of YOLOV4 to reduce the number of parameters and computational consumption. Second, an adaptive spatial-and-channel attention block is designed to optimize the neck of YOLOV4 in order to improve the feature extraction capability of our method and maintain the detection accuracy. Third, the focal loss is utilized to avoid the class imbalance problem during the training process. Finally, the method is evaluated on our real x-ray pseudocolor image dataset with YOLOV4 and YOLOV4-tiny. For the overall performance, the mean average precision of our method is 4.98% higher than YOLOV4-tiny and 0.07% lower than YOLOV4. The number of parameters and computational consumption of our method are slightly higher than YOLOV4-tiny and much lower than YOLOV4.
Asunto(s)
Rayos XRESUMEN
Nowadays, continuous efforts have been devoted to searching highly efficient electrochemiluminescence (ECL) emitters for applications in clinical diagnosis and food safety. In this work, triazinyl-based hydrogen bond organic frameworks (Tr-HOFs) were synthesized by N···H hydrogen bond self-assembly aggregation, where 6,6'-(1,4-phenylene)bis(1,3,5-triazine-2,4-diamine) (phenyDAT) was prepared via the cyclization reaction and behaved as a novel ligand. Impressively, the resulting Tr-HOFs showed strong ECL responses with highly enhanced ECL efficiency (21.3%) relative to the Ru(bpy)32+ standard, while phenyDAT hardly showed any ECL emission in aqueous phase. The Tr-HOFs innovatively worked as a new ECL luminophore to construct a label-free biosensor for assay of kanamycin (Kana). Specifically, the ECL response greatly weakened upon assembly of captured DNA with ferrocene (cDNA-Fc) onto the Tr-HOFs-modified electrode, while the ECL signals were adversely recovered by releasing linked DNA (L-DNA) from double-stranded DNA (dsDNA, hybridization of aptamer DNA (aptDNA) with L-DNA) due to the specific recognition of Kana with the aptDNA combined by the linkage of L-DNA and cDNA-Fc on the electrode. The as-built sensor showed a broadened linear range (1 nM-10 µM) and a limit of detection (LOD) down to 0.28 nM, which also displayed satisfactory results in the analysis of Kana in the milk and diluted human serum samples. This work offers a novel pathway to design an ECL emitter with organic molecules, holding great promise in biomedical analysis and food detection.
Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Humanos , Enlace de Hidrógeno , Límite de Detección , Mediciones LuminiscentesRESUMEN
In this work, metal-organic frameworks (MOFs) are utilized as effective ECL coreactant accelerator to enhance the ECL responses of N-(aminobutyl)-N-(ethylisoluminol) (ABEI). Zn-based MOFs (MOF-Zn-1) were prepared by chelating Zn ions with melamine and thiophenedicarboxylic acid (TPDA), which observably accelerated the electrocatalytic oxidation of tripropylamine (TPA). Then, ABEI-MOF-Zn-1 as a high-performance ECL emitter was synthesized via an amide reaction between ABEI and mercaptopropionic acid (MPA) modified MOF-Zn-1. Strikingly, the ABEI-MOF-Zn-1 showed the 18-fold increase in the ECL signals relative to pure ABEI by using TPA as a coreactant. Moreover, ferrocene (Fc) as a quencher was first linked with capture DNA (cDNA), and then used to modify the ABEI-MOF-Zn-1, thereby constructing a label-free ECL biosensor. After the linkage between chloramphenicol (CAP) and aptamer DNA (aptDNA), the ECL response was definitely recovered by releasing L-DNA from double-stranded DNA (dsDNA, hybridization of aptDNA and L-DNA). The resultant sensor showed a wide linear range of 1.00 nM-0.10 mM (R2 = 0.99) and a low limit of detection (LOD) down to 0.11 nM for detecting CAP. This work developed a novel pattern to design an efficient ECL enhanced emitter, coupled by expanding its potential applications in clinical diagnosis.
Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Estructuras Metalorgánicas , Cloranfenicol , Técnicas Electroquímicas , Límite de Detección , Mediciones LuminiscentesRESUMEN
Novel and distinct enhancement in electrochemiluminescence (ECL) signals of advanced organic luminophores are of importance for expanding their applications in early diagnosis. This work reported the construction of an ultrasensitive label-free ECL aptasensor for thrombin (TB) detection by grafting zinc proto-porphyrin IX (ZnP) onto an aminated zeolitic imidazole framework-8 (defined as ZnP-NH-ZIF-8 for clarity) as the luminophore. The structure and optical properties of the resulting ZnP-NH-ZIF-8 were carefully characterized. For that, there appeared to be weak ECL radiation for ZnP in dichloromethane (DCM) containing tetra-n-butylammonium perchlorate (TBAP) because of the as-formed singlet-state oxygen via the "reduction-oxidation" route. More notably, the ECL signals display 153-times enhancement for ZnP-NH-ZIF-8, thanks to the excellent catalytic kinetics for the oxygen reduction reaction (ORR). By virtue of the specific interactions of the TB aptamer (TBA) with the TB protein and the highly efficient catalysis of the ZnP-NH-ZIF-8 for ORR, the as-prepared aptasensor showed a wider linear range (0.1 fMâ¼1 pM) and a lower detection limit (ca. 58.6 aM). This work provides some useful guidelines for synthesis of an advanced organic luminophore with largely boosted ECL signals in ultrasensitive analysis and clinical diagnosis.
Asunto(s)
Técnicas Biosensibles/métodos , Imidazoles/química , Luminiscencia , Porfirinas/química , Trombina/análisis , Zeolitas/química , Aptámeros de Nucleótidos/metabolismo , Electroquímica , Trombina/química , Trombina/metabolismoRESUMEN
The robust and strong electrochemiluminescence (ECL) emission of organic emitters in an aqueous solution is crucial for expanding their applications in early diagnosis. Herein, a Zn porphyrin-based metal-organic framework ((Zn)porphMOF) was facilely obtained by chelating Zn(ii)meso-tetra (4-sulfonatophenyl) porphine (Zn-TSPP) with Zn ions, showing substantially enhanced ECL radiation with K2S2O8 as the coreactant via the "reduction-oxidation" route in aqueous media. In contrast with Zn-TSPP, (Zn)porphMOF displayed 22-fold increase in the ECL intensity because of the agglomeration effect. By virtue of the dramatic confinement towards the energy and electron transfer of ascorbic acid (AA) during the ECL process, an ultrasensitive biosensor was developed with a wide linear range (3.77 to 26.4 µM) and ultra-low detection limit of 0.29 µM at 3 times of the signal-to-noise ratio (3S/N). This work offers a feasible avenue to harvest the steady and boosted ECL responses of organic molecules in aqueous media, also greatly expanding the MOF applications in bioanalysis.
RESUMEN
A novel self-assembled glucose biosensor based on graphene oxide (GO) was constructed by using 1-pyrenebutyric acid-N-hydroxysuccinimide ester (PANHS) as linking molecular. The stepwise self-assembly process was performed for PANHS anchoring in N,N-dimethylformamide (DMF) solvent and the further glucose oxidase (GOD) binding in aqueous solution, respectively. The molecular interactions and the morphologic properties were characterized by Fourier transform infrared spectroscopy (FTIR), field emission scanning electronic microscopy (FESEM), and atomic force microscopy (AFM). In addition, the quantitative loadings of anchored PANHS and GOD were well elucidated by surface plasmon resonance (SPR) measurements. The obtained novel glucose sensor exhibited satisfactory analytical performance to glucose: wide linear range (4.0×10(-6) to 4.4×10(-3) M), fast response (10s), high sensitivity (40.5±0.4 mA M(-1) cm(-2)), and low detection limit (2 µM, S/N=3). Furthermore, the biosensor exhibited excellent long-term stability and satisfactory reproducibility.
Asunto(s)
Glucosa Oxidasa/metabolismo , Grafito/química , Óxidos/química , Resonancia por Plasmón de Superficie/métodos , Aspergillus niger/enzimología , Dimetilformamida/química , Electrodos , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/metabolismo , Glucosa/análisis , Glucosa Oxidasa/química , Límite de Detección , Platino (Metal)/química , Pirenos/química , Reproducibilidad de los Resultados , Solventes/química , Succinimidas/química , Resonancia por Plasmón de Superficie/instrumentaciónRESUMEN
ETHNOPHARMACOLOGICAL RELEVANCE: The Mesobuthus martensii scorpions, called as "Quanxie", are known Chinese medicinal material base on the "Combat poison with poison" strategy for more than one thousand years, and still widely used to treat various diseases according to the Pharmacopoeia of the People's Republic of China nowadays. AIM OF STUDY: The study aims to investigate the similarity of scorpion neurotoxins at the protein level between the juvenile and adult Mesobuthus martensii scorpions as Chinese medicine materials. MATERIALS AND METHODS: The second-, third- and fourth-instar, and adult Mesobuthus martensii scorpions were collected for the characterization of neurotoxin expression through multiple strategic proteomics, including undigested scorpion venom, endopeptidase-digested, and undigested scorpion telson extract for the sample analysis. RESULTS: Based on the known 107 scorpion neurotoxins from the genomic and transcriptomic analysis of adult Mesobuthus martensii scorpions, the multiple strategic proteomics first revealed that neurotoxins exhibited more stability in telson extract than secreted venom. In the reported transcripts of scorpion neurotoxins, approximately 53%, 56%, 66% and 78% of neurotoxins were detected through undigested scorpion venom, the endopeptidase Arg-C-, Lys-C-digested telson extract, and undigested telson extract strategies, respectively. Nearly 79% of scorpion neurotoxins detected in third-instar Mesobuthus martensii scorpions represent the largest number of scorpion neurotoxins from proteomic analysis to date. Moreover, a total of 84% of scorpion neurotoxins were successfully identified at the protein level, and similar neurotoxin expression profiles in second-, third- and fourth-instar, and adult Mesobuthus martensii scorpions were first revealed by the multiple strategic proteomics. CONCLUSION: These findings for the first time demonstrate the similar neurotoxin expression profiles between the juvenile and adult Mesobuthus martensii scorpions as Chinese medicinal material, which would serve as a paradigm for further toxin analysis from different venomous animals.
Asunto(s)
Medicina Tradicional China , Neurotoxinas , Proteómica , Venenos de Escorpión , Escorpiones , Animales , Proteómica/métodos , Animales PonzoñososRESUMEN
Nowadays, novel and efficient signal amplification strategy in electrochemiluminescence (ECL) platform is urgently needed to enhance the sensitivity of biosensor. In this work, the dual ECL signal enhancement strategy was constructed by the interactions of Pd nanoparticles attached covalent organic frameworks (Pd NPs@COFs) with tris (bipyridine) ruthenium (RuP) and Exonuclease III (Exo.III) cycle reaction. Within this strategy, the COFs composite was generated from the covalent reaction between 2-nitro-1,4-phenylenediamine (NPD) and trialdehyde phloroglucinol (Tp), and then animated by glutamate (Glu) to attach the Pd NPs. Next, the "signal on" ECL biosensor was constructed by the coordination assembly of thiolation capture DNA (cDNA) onto the Pd NPs@COFs modified electrode. After the aptamer recognition of progesterone (P4) with hairpin DNA 1 (HP1), the Exo. III cycle reaction was initiated with HP2 to generate free DNA, which hybridized with cDNA to form double-stranded DNA (dsDNA). For that, the RuP was embedded into the groove of dsDNA and achieved the ultrasensitive detection of P4 with a lower limit of detection (LOD) down to 0.45 pM, as well as the excellent selectivity and stability. This work expands the COFs-based materials application in ECL signal amplification and valuable DNA cyclic reaction in biochemical testing field.
Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Exodesoxirribonucleasas , Nanopartículas del Metal , Estructuras Metalorgánicas , Paladio , Progesterona , Nanopartículas del Metal/química , Estructuras Metalorgánicas/química , Paladio/química , Progesterona/análisis , Progesterona/química , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Exodesoxirribonucleasas/química , Exodesoxirribonucleasas/metabolismo , Límite de Detección , Mediciones Luminiscentes/métodos , Humanos , ADN/químicaRESUMEN
Thermally stable full-length scorpion toxin peptides and partially degraded peptides with complete disulfide bond pairing are valuable natural peptide resources in traditional Chinese scorpion medicinal material. However, their pharmacological activities are largely unknown. This study discovered BmKcug1a-P1, a novel N-terminal degraded peptide, in this medicinal material. BmKcug1a-P1 inhibited hKv1.2 and hKv1.3 potassium channels with IC50 values of 2.12 ± 0.27 µM and 1.54 ± 0.28 µM, respectively. To investigate the influence of N-terminal amino acid loss on the potassium channel inhibiting activities, three analogs (i.e., full-length BmKcug1a, BmKcug1a-P1-D2 and BmKcug1a-P1-D4) of BmKcug1a-P1 were prepared, and their potassium channel inhibiting activities on hKv1.3 channel were verified by whole-cell patch clamp technique. Interestingly, the potassium channel inhibiting activity of full-length BmKcug1a on the hKv1.3 channel was significantly improved compared to its N-terminal degraded form (BmKcug1a-P1), while the activities of two truncated analogs (i.e., BmKcug1a-P1-D2 and BmKcug1a-P1-D4) were similar to that of BmKcug1a-P1. Extensive alanine-scanning experiments identified the bonding interface (including two key functional residues, Asn30 and Arg34) of BmKcug1a-P1. Structural and functional dissection further elucidated whether N-terminal residues of the peptide are located at the bonding interface is important in determining whether the N-terminus significantly influences the potassium channel inhibiting activity of the peptide. Altogether, this research identified a novel N-terminal degraded active peptide, BmKcug1a-P1, from traditional Chinese scorpion medicinal material and elucidated how the N-terminus of peptides influences their potassium channel inhibiting activity, contributing to the functional identification and molecular truncation optimization of full-length and degraded peptides from traditional Chinese scorpion medicinal material Buthus martensii Karsch.
Asunto(s)
Péptidos , Bloqueadores de los Canales de Potasio , Venenos de Escorpión , Escorpiones , Bloqueadores de los Canales de Potasio/química , Bloqueadores de los Canales de Potasio/farmacología , Escorpiones/química , Venenos de Escorpión/química , Venenos de Escorpión/farmacología , Animales , Péptidos/química , Péptidos/farmacología , Humanos , Canal de Potasio Kv1.3/antagonistas & inhibidores , Canal de Potasio Kv1.3/metabolismo , Canal de Potasio Kv1.3/química , Proteolisis , Canal de Potasio Kv.1.2/metabolismo , Canal de Potasio Kv.1.2/antagonistas & inhibidores , Canal de Potasio Kv.1.2/química , Estabilidad Proteica , Secuencia de Aminoácidos , Técnicas de Placa-Clamp , Células HEK293RESUMEN
Nowadays, synthesis of novel organic photosensitizer is imperative but challenging for photoelectrochemical (PEC) assay in analytical and biomedical fields. In this work, the PEC responses enhanced about 4.3 folds after in situ electrostatic assembly of 1-butyl-3-methylimidazole tetrafluoroborate ([BIm][BF4]) on meso-tetra (4-carboxyphenyl) porphine (TP), which was first covalently linked with NH2 modified indium tin oxide electrode ([BIm]+--TP-NH2-ITO). Moreover, the [BIm]+--TP-NH2-ITO showed a much larger photocurrent in a water/dimethyl sulfoxide (DMSO) binary solvent with a water fraction (fw) of 90%, which displayed 6.7-fold increase over that in pure DMSO, coupled by discussing the PEC enhanced mechanism in detail. Then, the PEC signals were sharply quenched via a competitive reaction between magnetic bead linked dsDNA (i.e., initial hybridization of aptamer DNA with linking DNA) and HCT-116 cells (closely associated with CRC), where the liberated L-DNA stripped the [BIm]+ from [BIm]+--TP-NH2-ITO. The PEC detection strategy exhibited a wider linear range (30 â¼ 3 × 105 cells mL-1) and a lower limit of detection (6 cells mL-1), achieving single-cell bioanalysis even in diluted human serum sample. The in situ assembly strategy offers a valuable biosensing platform to amplify the PEC signals with advanced organic photosensitizer for early diagnosis of tumors.
Asunto(s)
Técnicas Biosensibles , Porfirinas , Humanos , Fármacos Fotosensibilizantes/farmacología , Electricidad Estática , Dimetilsulfóxido , Células HCT116 , ADN , AguaRESUMEN
For personal safety and crime prevention, some research studies based on deep learning have achieved success in the object detection of X-ray security inspection. However, the research on dangerous liquid detection is still scarce, and most research studies are focused on the detection of some prohibited and common items. In this paper, a lightweight dangerous liquid detection method based on the Depthwise Separable convolution for X-ray security inspection is proposed. Firstly, a dataset of seven common dangerous liquids with multiple postures in two detection environments is established. Secondly, we propose a novel detection framework using the dual-energy X-ray data instead of pseudocolor images as the objects to be detected, which improves the detection accuracy and realizes the parallel operation of detection and imaging. Thirdly, in order to ensure the detection accuracy and reduce the computational consumption and the number of parameters, based on the Depthwise Separable convolution and the Squeeze-and-Excitation block, a lightweight object location network and a lightweight dangerous liquid classification network are designed as the backbone networks of our method to achieve the location and classification of the dangerous liquids, respectively. Finally, a semiautomatic labeling method is proposed to improve the efficiency of data labeling. Compared with the existing methods, the experimental results demonstrate that our method has better performance and wider applicability.
Asunto(s)
Proyectos de Investigación , Rayos XRESUMEN
For public security and crime prevention, the detection of prohibited items in X-ray security inspection based on deep learning has attracted widespread attention. However, the pseudocolor image dataset is scarce due to security, which brings an enormous challenge to the detection of prohibited items in X-ray security inspection. In this paper, a data augmentation method for prohibited item X-ray pseudocolor images in X-ray security inspection is proposed. Firstly, we design a framework of our method to achieve the dataset augmentation using the datasets with and without prohibited items. Secondly, in the framework, we design a spatial-and-channel attention block and a new base block to compose our X-ray Wasserstein generative adversarial network model with gradient penalty. The model directly generates high-quality dual-energy X-ray data instead of pseudocolor images. Thirdly, we design a composite strategy to composite the generated and real dual-energy X-ray data with background data into a new X-ray pseudocolor image, which can simulate the real overlapping relationship among items. Finally, two object detection models with and without our data augmentation method are applied to verify the effectiveness of our method. The experimental results demonstrate that our method can achieve the data augmentation for prohibited item X-ray pseudocolor images in X-ray security inspection effectively.
Asunto(s)
Atención , Rayos XRESUMEN
Cytochrome c (cyt c) plays a critical role in mitochondrial respiratory chain, whose absence is detrimental to electron transport and reduce adenosine triphosphate. For ultrasensitive detection of cyt c, sheet-like covalent organic frameworks (COFs) were prepared by orderly accumulation of 1,3,5-benzenetricarboxaldehyde (BTA) and p-phenylenediamine (PDA), and further grafted with N-(4-aminobutyl)-N-ethylisoluminol (ABEI) - an electrochemiluminescence (ECL) emitter. Specifically, the morphology and structure of the COFs-ABEI were mainly characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD) analysis, and X-ray photoelectron spectroscopy (XPS). In parallel, the optical properties of the emitter were certified by UV-vis absorbance spectroscopy, Fourier infrared spectroscopy (FTIR), fluorescence (FL), and ECL measurements, showing 2.25-time enhanced ECL efficiency over pure ABEI, coupled by illustrating the interfacial electron transport mechanism. On the above foundation, a label-free "signal off" ECL biosensor was constructed by virtue of the specific immune recognition between the aptamer of the target cyt c with its capture DNA (cDNA) anchored on the biosensing platform, exhibiting a wider linear range of 1.00 fg mL-1-0.10 ng mL-1 (R2 = 0.998) and a lower limit of detection (LOD) down to 0.73 fg mL-1. This work offers some constructive guidelines for sensitive bioassays of disease-related biomarkers in the clinical field.