Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 99 Suppl 1: 1482-1489, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35324060

RESUMEN

OBJECTIVES: We aimed to validate a novel staging system for aortic stenosis (AS) in a Chinese patient cohort undergoing transcatheter aortic valve replacement (TAVR), and to compare this classification system to the traditional Society of Thoracic Surgeons (STS) score for TAVR risk stratification. BACKGROUND: A novel staging system for AS based on the extent of cardiac damage upon echocardiography was recently proposed. METHODS: Patients were prospectively enrolled into the Transcatheter Aortic Valve Replacement Single Center Registry in Chinese Population and analyzed retrospectively following additional exclusion criteria. On the basis of echocardiographic findings of cardiac damage, patients were classified into five stages (0-4). RESULTS: A total of 427 patients were included in the current analysis. Forty-eight deaths occurred during a median follow-up of 730 days following TAVR. The staging system showed a statistically significant association between cardiac damage and all-cause mortality; advanced stages were associated with higher mortality. In a multivariate-adjusted Cox proportional hazards regression model, stage and STS scores served as risk factors for 2-year mortality. Each increment in the staging class was associated with an increased risk of mortality (hazard ratio, 1.275; 95% confidence interval [CI], 1.052-1.545). Receiver operating characteristic (ROC) curves were plotted for stage (area under the curve, 0.644; 95% CI, 0.562-0.725) and STS score (0.661; 0.573-0.749), and with no statistically significant differences between ROC curves (p = 0.920). CONCLUSIONS: We validated a novel staging system as a key risk factor for 2-year mortality in a Chinese TAVR patient cohort. Efficacy for risk stratification was comparable to the STS score.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , China , Humanos , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA