Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Nucl Cardiol ; 30(1): 343-353, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35819715

RESUMEN

AIMS: This prospective, single-center study sought to assess to what extent there is interference between the hybrid technique of single-photon emission tomography-computed tomography with technetium99m-hexamethylpropyleneamine oxime-labeled leukocytes (99mTc-HMPAO-SPECT/CT) and antimicrobial therapy in patients with infective endocarditis (IE). METHODS AND RESULTS: During the years 2015-2019, we enrolled 205 consecutive adults with suspected IE, all underwent 99mTc-HMPAO-SPECT/CT. The study population was divided into those who had received antimicrobial therapy up to 30 days prior to 99mTc-HMPAO-SPECT/CT (group 1, n = 96) and those who had not (group 2, n = 109). Patients were prospectively observed for 12 ± 10 months. Group 1 presented higher positive predictive values (91.89% vs. 60.00%, = 0.001), and decreased negative predictive values (77.97% vs. 90.54%, P = 0.04). Patients treated with antimicrobial therapy displayed false-negative 99mTc-HMPAO-SPECT/CT results more often [odds ratio (OR), 4.63; 95% confidence interval (CI), 1.41-15.23, P = .01], particularly when intravenous (OR 5.37; 95% CI 1.73-16.62, P = .004), definite (OR 9.43; 95% CI 2.65-33.51, P = .001), and combination antibiotic regimens (OR 8.1; 95% CI 2.57-25.64, P = .001) had been administered. CONCLUSION: Prior antibiotic therapy affects 99mTc-HMPAO-SPECT/CT diagnostic properties. Patients treated with antimicrobial therapy display false-negative 99mTc-HMPAO-SPECT/CT results more often, especially if intravenous, definite, or combination regimens are administered.


Asunto(s)
Antiinfecciosos , Endocarditis Bacteriana , Endocarditis , Adulto , Humanos , Exametazima de Tecnecio Tc 99m , Estudios Prospectivos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Leucocitos
2.
Europace ; 25(3): 1100-1109, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36660771

RESUMEN

AIMS: To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems. METHODS AND RESULTS: Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B. CONCLUSION: The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/métodos , Resultado del Tratamiento , Estudios Retrospectivos
3.
Echocardiography ; 40(10): 1068-1078, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37632153

RESUMEN

BACKGROUND: His bundle pacing (HBP) has proved to be a valuable alternative enabling the physiological activation of cardiac contraction in cardiac resynchronization therapy (CRT). At present, however, little is known about the optimal method of programming of the His bundle-paced CRT systems in terms of achieving the best cardiac output. AIM: The aim of this study was to evaluate the impact of cardiac resynchronization therapy with conduction system pacing (CRT+CSP) on echo-based hemodynamic parameters in the early post-operative measurements. METHODS: The study enrollment criteria included: permanent atrial fibrillation, heart failure and bundle branch block. All patients underwent implantation of CRT + HBP. During the post-operative phase, we aimed to optimize HOT-CRT settings in order to achieve the greatest cardiac output assessed by complex echocardiographic measurements. RESULTS: The study included 21 patients, mean age 71.2 (6.3) years, predominantly men (71.4%) with non-ischemic cardiomyopathy 62%. All patients had heart failure with NYHA functional class III and IV (81%). Mean left ventricular ejection fraction was 27.5 (9.7%). The mean duration of the QRS complex was 148.8 ms. The effects of resynchronization pacing: HBP alone, HBP with left ventricular pacing, HBP with biventricular pacing (BiV) and BiV without HBP ​​were analyzed consecutively. HBP combined with left ventricular pacing demonstrated the best hemodynamic response. CONCLUSION: His bundle pacing coupled with LV pacing proved to be the most advantageous pacing program setting with regard to cardiac output. Moreover, it performed better than biventricular pacing and significantly better than RV pacing.

4.
J Electrocardiol ; 72: 1-5, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35219111

RESUMEN

Algorithms designed to reduce the right ventricular (RV) pacing burden are widely available in modern dual-chamber implantable pacing devices. These algorithms allow the atrioventricular delay for sensed ventricular events to be longer than for ventricular paced events. However, since these features are unique to pacemaker manufacturers, they often produce unfamiliar electrocardiographic (ECG) appearances that suggest pacemaker dysfunction. We describe a Vp suppression algorithm used in Biotronik dual-chamber pacemakers and implantable cardioverter-defibrillator devices.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Algoritmos , Estimulación Cardíaca Artificial , Electrocardiografía , Ventrículos Cardíacos , Humanos
5.
Pacing Clin Electrophysiol ; 44(1): 148-150, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33165971

RESUMEN

The electrocardiogram (ECG) interpretation in patients with implantable cardioverter defibrillator (ICD) is often a puzzling problem. The difficulty of the device function evaluation further increases in the presence of unfamiliar timing cycles and additional functions. We present an interesting ECG with a special function of a Biotronik ICD devices called the thoracic impedance monitoring, and demonstrate its behavior in a patient with atrial fibrillation, pacing beats, ventricular ectopic beats, and couple of ventricular beats. This report shows unexceptional occurrence of tricky ECG finding in patient with Biotronik ICDs.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Impedancia Eléctrica , Electrocardiografía Ambulatoria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevención Primaria
6.
Pacing Clin Electrophysiol ; 42(7): 998-1005, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31045256

RESUMEN

OBJECTIVE: To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) with mechanical systems of pacing leads older than 20 years (group A) versus younger leads (group B). METHODS: We performed TLE of 591 pacing leads in 377 patients. Fifty (8.5%) leads in 43 (11.4%) patients were implanted for equal to or more than 20 years. The mean dwell time of all extracted leads was 8.9 years (range, 0.1-36.0). Infection related to cardiovascular implantable electronic device was an indication for TLE in 18.3% of patients. RESULTS: Complete lead removal and complete procedural success rates were similar between both groups (94.7% in group A vs 97.1% in group B, P = 0.445, and 90.7% in group A vs 95.8% in group B, P = 0.329, respectively). Incomplete lead removal in group A was observed only in leads older than 20 years. Removal of leads in group A was associated with significantly longer fluoroscopy time compared with group B (4.6 vs 1.9 minutes, P < 0.001). We did not find a significant difference in major and minor complication rates between groups (2.3% in group A vs 0.9% in group B and 2.3% in group A vs 2.2% in group B, P = 0.687, respectively). There were no deaths associated with the TLE procedure within 30 days after the procedure in either group. CONCLUSION: This study shows that TLE of leads older than 20 years conducted at an experienced center seems to be comparably safe and effective as extraction of younger leads but requires longer fluoroscopy time.


Asunto(s)
Remoción de Dispositivos/métodos , Electrodos Implantados , Marcapaso Artificial , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Falla de Equipo , Fluoroscopía , Humanos , Persona de Mediana Edad , Seguridad del Paciente , Infecciones Relacionadas con Prótesis/etiología , Estudios Retrospectivos , Factores de Tiempo
7.
Pacing Clin Electrophysiol ; 42(3): 374-380, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30659629

RESUMEN

AIMS: A novel therapy offering cardiac resynchronization therapy (CRT) with an additional lead placed in His bundle has been reported in a few case reports and case series as improving the hemodynamical and clinical condition of patients with permanent atrial fibrillation (AF) in whom other therapeutic methods have not been successful. METHODS: Fourteen consecutive patients with permanent AF, heart failure (HF), bundle branch block (BBB) with QRS complex width >130 ms, and impaired left ventricular ejection fraction (LVEF) underwent implantation of implantable cardioverter defibrillator (ICD)/CRT systems with His bundle pacing (HBP). During the follow-up, we assessed the efficacy of ICD/CRT systems with HBP in HF treatment. RESULTS: The study cohort consisted of 14 patients with the mean age of 67.35 ± 10 years. The mean duration of QRS was 159.2 ± 28.6 ms, mean LVEF was 24.36 ± 10.7%, and mean follow-up duration was 14.4 months. One patient died due to HF aggravation during the follow-up. In the remaining 13 patients, the mean LVEF significantly improved from 24% to 38%, P = 0.0015. The left ventricular end-diastolic dimension decreased from 72 mm to 59 mm, P < 0.001; left ventricular end-systolic dimension decreased from 59 mm to 47 mm, P = 0.0026. The mean QRS duration shortened from 159 ms to 128 ms, P = 0.016. The mean percentage of HBP reached 97%. As a result, 92.3% of patients demonstrated significant improvement in the New York Heart Association functional class, P < 0.001. CONCLUSION: The use of atrial channel for HBP, choice of optimal ICD/CRT pacing configuration, and optimization of pharmacological therapy resulted in a substantial narrowing of QRS width and clinical improvement in left ventricular mechanical function during the follow-up.


Asunto(s)
Fibrilación Atrial/terapia , Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca/métodos , Anciano , Fibrilación Atrial/fisiopatología , Bloqueo de Rama/fisiopatología , Femenino , Humanos , Masculino
8.
Ann Noninvasive Electrocardiol ; 24(2): e12545, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-29693306

RESUMEN

The electrocardiogram (ECG) interpretation in patients with implantable cardioverter defibrillator (ICD) is often a puzzling problem. The difficulty of the device function evaluation further increases in the presence of unfamiliar timing cycles and additional functions. Authors present a special function of a Biotronik ICD devices called the thoracic impedance monitoring, and demonstrate its behavior in a patient with sinus rhythm, ventricular ectopic beats, and ventricular tachycardia episode. This report shows unexceptional occurrence of tricky ECG finding in patient with Biotronik ICD.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Electrocardiografía , Seguridad de Equipos , Taquicardia Ventricular/diagnóstico por imagen , Desfibriladores Implantables , Electrocardiografía Ambulatoria/métodos , Diseño de Equipo , Humanos , Masculino , Persona de Mediana Edad , Medición de Riesgo
9.
Ann Noninvasive Electrocardiol ; 24(4): e12648, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30896054

RESUMEN

The electrocardiogram (ECG) interpretation in patients with implantable pacemaker is often a perplexing problem. The difficulty in the device evaluation increases in the presence of novel timing cycles and additional functions. Authors describe a special function frequently encountered in Medtronic dual-chamber pacemakers and implantable cardioverter-defibrillator devices called managed ventricular pacing (MVP) and demonstrate its performance in the patient with undersensing episodes in ventricular channel. Intermittent ventricular undersensing in the device with MVP feature turned on caused repetitive mode switches between AAI and DDD mode. This report shows unexceptional occurrence of tricky ECG findings in patient with Medtronic dual-chamber device.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Marcapaso Artificial , Anciano , Femenino , Humanos
10.
Pol Merkur Lekarski ; 47(278): 65-66, 2019 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-31473754

RESUMEN

A CASE REPORT: A 65-year-old male patient underwent left-sided placement of implantable cardioverter-defibrillator. At three years after implantation he emerged complaining on left upper limb and left-sided neck edema. Left brachicephalic vein thrombosis due to device leads was recognized. The attending cardiologist referred the patient to university radiology department for venous angioplasty but the patient was admitted to cardiology department. Coronary angiography was performed due to suspicion of ischemic heart disease. However, it showed the presence of foreign body in cardiovascular system - completely intravascular round-tipped guide wire used in Seldinger technique for insertion of the endocardial lead abandoned in left subclavian vein and reaching to superior vena cava. Patient was transferred to third-degree reference lead extraction center. The procedure was performed under general anesthesia in hybrid operating room. Via femoral vein access we introduced Needle's Eye Snare and grasped the guide wire. Then, using polytetrafluoroethylene sheath the tissue adhesions were dissected and the complete guide wire was retrieved.


Asunto(s)
Desfibriladores Implantables , Migración de Cuerpo Extraño , Síndrome de la Vena Cava Superior , Anciano , Desfibriladores Implantables/efectos adversos , Humanos , Masculino , Síndrome de la Vena Cava Superior/etiología , Vena Cava Superior
11.
Pacing Clin Electrophysiol ; 41(9): 1217-1223, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30055057

RESUMEN

INTRODUCTION: We evaluated the influences of selected factors on electrical lead failure (ELF) occurrence in patients referred for transvenous lead extraction (TLE) procedures. METHODS AND RESULTS: The study cohort consisted of 432 patients referred for TLE procedures due to various indications (42 - lead-dependent infective endocarditis, 47 - pocket infection, 343 - noninfectious indications) with a total of 804 endocardial leads. In the analyzed group, there were 192 patients with ELF, denoted as group ELF(+) (200 malfunctioning endocardial leads). The percentage of women was higher in the ELF(+) group than in the ELF(-) group (42.7% vs 30.0%; P  =  0.006). The ELF(+) patients had more endocardial leads implanted via subclavian vein puncture (80.0% vs 72.4%; P  =  0.032), had more indwelling leads in the cardiovascular system (1.94 vs 1.8; P  =  0.03), were older (68.9 vs 66.0 years old; P  =  0.028), and had better left ventricular ejection fractions than the ELF(-) patients (48.0% vs 40.7%; P < 0.001). The time interval to ELF occurrence was significantly longer for pacing leads than for cardioverter-defibrillator leads (95.7 vs 65.7 months; P  =  0.016). The most important factor associated with ELF was subclavian vein puncture, increasing the risk of ELF occurrence by 2.5-fold and 2.7-fold in the univariate and multivariate Cox proportional hazards regression models, respectively. The presence of a cardioverter-defibrillator lead increased the risk of ELF by 1.9-fold and 2.7-fold in the univariate and multivariate models, respectively. CONCLUSION: The most significant factors predisposing patients to ELF are the lead implantation approach and the presence of a cardioverter-defibrillator lead.


Asunto(s)
Remoción de Dispositivos , Electrodos Implantados/efectos adversos , Marcapaso Artificial/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Endocarditis/etiología , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/etiología , Sistema de Registros , Factores de Riesgo
12.
Artículo en Inglés | MEDLINE | ID: mdl-28593660

RESUMEN

The electrocardiogram (ECG) interpretation in patients with cardiac resynchronization therapy (CRT) is often a perplexing problem. The difficulty in the device evaluation increases in the presence of unfamiliar timing cycles and a lead dysfunction. Authors describe a special function of a Biotronik CRT devices called the left ventricle T-wave protection (LVTP), and demonstrate its behavior in a patient with left ventricular (LV) lead failure. This report shows that sometimes it might be difficult to understand the loss of resynchronization in 12-lead ECG when LVTP feature is on, and a malfunction of left ventricular lead sensing occurs.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/métodos , Falla de Equipo , Insuficiencia Cardíaca/etiología , Ventrículos Cardíacos/fisiopatología , Marcapaso Artificial , Algoritmos , Diagnóstico Diferencial , Electrocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Persona de Mediana Edad , Resultado del Tratamiento
13.
J Electrocardiol ; 51(3): 405-408, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29525386

RESUMEN

CRT is a therapeutic option for patients with heart failure, sinus rhythm, prolonged QRS complex duration and reduced ejection fraction. We present a case of 71-year-old woman with dilated cardiomyopathy, NYHA functional class III and AF. We implanted CRT combined with direct His-bundle pacing. The indication for such a therapy was a left bundle branch block with a QRS complex of 178ms and a left ventricular EF of 15%, left ventricular end-diastolic diameter (LVEDD) of 75mm. After 8months of follow-up the LVEDD was 60mm with EF 35-40%.


Asunto(s)
Fibrilación Atrial/terapia , Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Cardiomiopatía Dilatada/terapia , Electrocardiografía , Insuficiencia Cardíaca/terapia , Anciano , Fibrilación Atrial/fisiopatología , Bloqueo de Rama/fisiopatología , Cardiomiopatía Dilatada/fisiopatología , Angiografía Coronaria , Ecocardiografía , Femenino , Insuficiencia Cardíaca/fisiopatología , Humanos , Resultado del Tratamiento
14.
J Electrocardiol ; 51(3): 487-489, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29779529

RESUMEN

The electrocardiogram (ECG) interpretation in patients with cardiac resynchronization therapy (CRT) may be challenging. The difficulty increases if not well-known pacemaker algorithm is turned on. We show a T-wave protection algorithm (LVTP) in a patient with CRT. Accelerated sinus rhythm and intermittent oversensing in left ventricular channel resulted in loss of CRT pacing. The restoration of biventricular pacing occurred when atrial rate decreased. We provide detailed descriptions of the electrocardiogram and intracardiac electrogram. LVTP may confuse ECG examination interpretation, especially in patients with accelerated atrial rhythm and oversensing in left ventricular channel.


Asunto(s)
Algoritmos , Bloqueo de Rama/terapia , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Muerte Súbita Cardíaca/prevención & control , Análisis de Falla de Equipo , Insuficiencia Cardíaca/terapia , Anciano , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino
15.
Pol Merkur Lekarski ; 44(259): 23-25, 2018 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-29374419

RESUMEN

A man with non-ischemic cardiomyopathy, EF 22%, permanent AF and ICD was admitted for elective device replacement. The need for the optimization of the ventricular rate and avoidance of right ventricular pacing made it necessary to up-grade the existing pacing system using direct His bundle pacing and dual chamber ICD. This enabled the regularization of ventricular rate, avoiding the RV pacing and optimize the beta-blocker dose. The one month follow-up already showed reduction in left ventricle diameter, improvement in ejection fraction, NYHA class decrease to II. The His bundle pacing enabled the optimal treatment of the patient resulting in excellent clinical improvement.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Fibrilación Atrial/terapia , Cardiomiopatías/complicaciones , Desfibriladores Implantables , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Humanos , Masculino , Resultado del Tratamiento
16.
Artículo en Inglés | MEDLINE | ID: mdl-28044401

RESUMEN

The 24-hr electrocardiogram (ECG) interpretation in patients with double-chamber pacemakers may be challenging. The difficulty increases if not well-known pacemaker algorithm and device malfunction coexist. We show atrial synchronization pace (ASP) in a patient with ventricular lead damage. We provide detailed description of electrocardiogram and intracardiac electrogram. ASP may confuse 24-hr ECG monitoring interpretation, especially in patients with ventricular lead dysfunction.


Asunto(s)
Complejos Atriales Prematuros/diagnóstico , Estimulación Cardíaca Artificial/métodos , Electrocardiografía Ambulatoria/métodos , Marcapaso Artificial , Disfunción Ventricular/diagnóstico , Anciano de 80 o más Años , Complejos Atriales Prematuros/complicaciones , Complejos Atriales Prematuros/fisiopatología , Femenino , Humanos , Disfunción Ventricular/complicaciones , Disfunción Ventricular/fisiopatología
17.
Acta Cardiol ; 72(1): 61-67, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28597736

RESUMEN

Objective The aim of this study was to evaluate the incidence of venous stenosis and occlusion (VSO) in patients referred for transvenous lead extraction (TLE) with regard to the indications for this treatment and to analyse the influence of VSO on efficacy, complications and technical challenges of TLE procedures. Methods The material consists of 133 consecutive TLE procedure records. The contrast venography examination of the ipsilateral access vein was performed prior to the operation. The whole study population was divided into two subgroups, based on the presence (subgroup I) or absence (subgroup II) of VSO. Results Phlebography was performed in 133 patients with age ranging from 25.7 to 86.1 years, 44 female (33.1%). The VSO was confirmed in 48 (36.1%) patients - subgroup I. Most of the patients were referred to TLE due to non-infectious reasons (100 pts-75.2%). The absence of VSO was observed substantially more frequently in patients with diabetes (P = 0.02). Procedural success rate reached 93.3% in subgroup I and 98.8% in subgroup II (P = 0.1). There was no significant difference in the use of advanced tools and alternative access sites. Conclusion The presence of VSO can be expected in one third of patients referred for lead extraction. There is no association between indication for TLE (infected or noninfected lead extraction) and the incidence of VSO. Diabetes proved to have a protective effect on venous patency in the previously mentioned group. VSO does not influence the effectiveness, safety, and the use of additional tools during TLE procedures.


Asunto(s)
Venas Braquiocefálicas , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/métodos , Marcapaso Artificial/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/terapia , Constricción Patológica/diagnóstico , Constricción Patológica/etiología , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flebografía , Factores de Riesgo
18.
Pol Merkur Lekarski ; 42(251): 187-192, 2017 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-28557964

RESUMEN

Venous stenosis and occlusion (VSO) in the presence of endocardial leads constitute one of the complications of permanent cardiac pacing. At present there are no scientific reports on the influence of sex on the incidence of VSO. AIM: The aim of the study was to examine the influence of sex on the incidence of VSO in patients with earlier implanted endocardial leads in a single-center retrospective analysis. MATERIALS AND METHODS: The material consists of 284 records of consecutive patients admitted to hospital to undergo electrotherapy procedures. In all patients a contrast venography for ipsilateral venous confluence was performed before the procedure. Patients were divided into two groups according to sex criterion. Groups were compared concerning following parameters: demographic characteristics, cardiac implantable electronic device (CIED) characteristics, comorbidities, CHA2DS2-VASc score, selected risk factors for VSO. RESULTS: Group I consist of 101 females, whereas group II consist of 183 males. Both groups did not differ significantly for age, number of implanted endocardial leads and lead dwell time. In the cohort males were with significantly greater burden of morbidity, reflected by the mean result of CHA2DS2-VASc (P=0.0098). In males there was significantly more often chronic heart failure (P<0.0001), chronic obstructive pulmonary disease (P=0.0450) and tobacco use (P=0.0159). Males had more ICD implanted than females (P=0.0270). In the examine cohort 88 patients (31%) had VSO. There was no statistically significant difference in terms of presence of VSO between females and males (P=0.4685). The detailed analysis of the patients with VSO divided according to sex revealed higher morbidity in males. CONCLUSIONS: The equality of VSO incidence in groups of males and females along with the predominance of factors protecting against VSO in group of males support the assumption that female gender is a protective factor against the development of VSO, equally as known protective factors in males.


Asunto(s)
Marcapaso Artificial/efectos adversos , Venas , Adulto , Anciano , Anciano de 80 o más Años , Comorbilidad , Constricción Patológica/epidemiología , Constricción Patológica/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polonia/epidemiología , Estudios Retrospectivos , Factores Sexuales , Adulto Joven
19.
Acta Cardiol ; 71(1): 41-5, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26853252

RESUMEN

OBJECTIVE: Dual-chamber (DDD) pacing is the most commonly used mode of heart stimulation. The data on gender-related differences in the long-term follow-up of DDD pacing mode are still limited. We performed a retrospective single-centre study to determine the effect of gender on the implantation indications and the incidence of adverse events resulting in DDD mode loss. METHODS AND RESULTS: A group of 1,049 consecutive patients with DDD pacemaker implanted between 1984 and 2002 were followed up until 2014. The study group consisted of 995 patients who performed at least one follow-up visit. Follow-up period was 124.2 ± 68.3 months, mean age was 63.5 ± 12.4 years, 56% were male. Adverse events were defined as loss of primary DDD stimulation--lead malfunction, progression to permanent AF, and infective complications. Women were older than men (64.7 vs 62.6 years) at the time of implantation and they remained, on average, 1.5 year longer in follow-up compared with men. Female patients had significantly more SSS, history of paroxysmal AF, and a similar percentage of AVB compared with male patients. The incidence of lead malfunction, device-related infections, and progression to permanent AF did not show significant differences. However, in the group without prior paroxysmal AF, women developed permanent AF more frequently. CONCLUSIONS: This patients cohort showed that there is an association between gender and indications to DDD pacing therapy. The rate of adverse events was similar in both genders. Women had a significantly longer duration of follow-up, despite markedly higher age at implantation.


Asunto(s)
Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial , Marcapaso Artificial , Adolescente , Adulto , Distribución por Edad , Anciano , Fibrilación Atrial/epidemiología , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Polonia/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Distribución por Sexo , Factores de Tiempo , Resultado del Tratamiento
20.
Acta Cardiol ; 70(6): 685-92, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26717217

RESUMEN

INTRODUCTION: Transvenous lead extraction (TLE) is a recognized method of treatment in the case of permanent stimulation complication. OBJECTIVES: The objective of this study was to analyse the indications and presentation of the early experience of TLE procedures in a group of patients with old pacing systems. PATIENTS AND METHODS: Patients with a relevant history of stimulation (at least 12 months in case of a pacemaker) qualified for the research. Indications, effectiveness and complications of TLE procedures were analysed. RESULTS: Two hundred patients at the age of 66.4 (19.1-86.2 years) were enrolled and 278 leads with dwell time 76.2 months (2.1-327.4) were removed. The indications for TLE were: lead-dependent infective endocarditis in 13 cases (6.5%), pocket infection in 29 cases (14.5%), lead damage in 120 cases (60.0%), and upgrade of device system in 38 cases (19.0%). Manual traction was used to remove 66 active fixation leads (23.7%). A femoral approach was required to extract 4 leads (1.4%). Two hundred and eight leads (74.8%) were extracted using the mechanical (Cook) system and subclavian approach. Laser technique, and an electrosurgical sheath were not used. Complete procedural success was achieved in 96% of cases and overall clinical success was 98.5%. Complication rate was 5.5% (11 patients): minor and major complication rate was 3.0% (6 patients) and 2.5% (5 cases), respectively. Low body mass index (BMI) was associated with a higher rate of complications. CONCLUSIONS: The dominant indication to TLE procedures was lead dysfunction. Transvenous lead extraction has a high success rate and a low complication rate. Low BMI increased the complication rate.


Asunto(s)
Cateterismo Periférico/métodos , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/métodos , Endocarditis/cirugía , Marcapaso Artificial/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Endocarditis/etiología , Falla de Equipo , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA