1.
Z Med Phys ; 32(1): 39-51, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33640219

RESUMEN

In December 2016 the clinical operation has started at the particle therapy centre MedAustron, Wiener Neustadt, Austria. Different commercial immobilisation devices are used for head patients. These immobilisation devices are a combination of table tops (Qfix BoS™ Headframe, Elekta HeadStep™), pillows (BoS™ Standard pillow, Moldcare®, HeadStep™ pillow) and thermoplastic masks (Klarity Green™, Qfix Fibreplast™, HeadStep™ iCAST double). For each patient image-guided radiotherapy (IGRT) is performed by acquiring orthogonal X-ray imaging and 2D3D registration and the application of the resulting 6-degree of freedom (DOF) position correction on the robotic couch. The inter- and intrafraction displacement of 101 adult head patients and 27 paediatric sedated head patients were evaluated and compared among each other regarding reproducibility during the entire treatment and stability during each fraction. For the comparison, statistical methods (Shapiro-Wilk test, Mann-Whitney U-test) were applied on the position corrections as well as on the position verifications. The actual planning target volume margins of 3mm (adults) and 2mm (children) were evaluated by applying the van Herk formula on the intrafraction displacement results and performing treatment plan robustness simulations of twelve different translational offset scenarios including a HU uncertainty of 3.5%. Statistically significant differences between the immobilisation devices were found, but they turned out to be clinically irrelevant. The margin calculation for adult head patients resulted in 0.8mm (lateral), 1.2mm (cranio-caudal) and 0.6mm (anterior-posterior), and for paediatric head patients under anaesthesia in 0.8mm (lateral), 0.5mm (cranio-caudal) and 0.9mm (anterior-posterior). Based on these values, robustness evaluations of selected adult head patients and sedated children showed the validity of the currently used PTV margins.


Asunto(s)
Inmovilización , Radioterapia Guiada por Imagen , Niño , Humanos , Inmovilización/métodos , Máscaras , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Reproducibilidad de los Resultados
2.
Z Med Phys ; 28(3): 196-210, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29107440

RESUMEN

The ratio of patients who need a treatment adaptation due to anatomical variations at least once during the treatment course is significantly higher in light ion beam therapy (LIBT) than in photon therapy. The ballistic behaviour of ion beams makes them more sensitive to changes. Hence, the delivery of LIBT has always been supported by state of art image guidance. On the contrary CBCT technology was adapted for LIBT quite late. Adaptive concepts are being implemented more frequently in photon therapy and also efficient workflows are needed for LIBT. The MedAustron Ion Beam Therapy Centre was designed to allow the clinical implementation of adaptive image-guided concepts. The aim of this paper is to describe the current status and the potential future use of the technology installed at MedAustron. Specifically addressed is the beam delivery system, the patient alignment system, the treatment planning system as well as the Record & Verify system. Finally, an outlook is given on how high quality X-ray imaging, MR image guidance, fast and automated treatment planning as well as in vivo range verification methods could be integrated.


Asunto(s)
Neoplasias/radioterapia , Radioterapia/instrumentación , Radioterapia/métodos , Instituciones Oncológicas/organización & administración , Instituciones Oncológicas/normas , Instituciones Oncológicas/tendencias , Humanos , Neoplasias/diagnóstico por imagen , Radioterapia/normas , Radioterapia/tendencias , Planificación de la Radioterapia Asistida por Computador/tendencias
3.
Med Phys ; 44(1): 132-142, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28102960

RESUMEN

PURPOSE: Couch-mounted cone-beam computed tomography (CBCT) imaging devices with independently rotatable x-ray source and flat-panel detector arms for acquisitions of arbitrary regions of interest (ROI) have recently been introduced in image-guided radiotherapy (IGRT). This work analyzes mechanical limitations and gravity-induced effects influencing the geometric accuracy of images acquired with arbitrary angular constellations of source and detector in nonisocentric trajectories, which is considered essential for IGRT. In order to compensate for geometric inaccuracies of this modality, a 9-degrees-of-freedom (9-DOF) flexmap correction approach is presented, focusing especially on the separability of the flexmap parameters of the independently movable components of the device. METHODS: The 9-DOF comprise a 3D translation of the x-ray source focal spot, a 3D translation of the flat-panel's active area center and three Euler-rotations of the detector's row and column vectors. The flexmap parameters are expressed with respect to the angular position of each of the devices arms. Estimation of the parameters is performed, using a CT-based structure set of a table-mounted, cylindrical ball-bearing phantom. Digitally reconstructed radiograph (DRR) patches are derived from the structure set followed by local 2D in-plane registration and subsequent 3D transform estimation by nonlinear regression with outlier detection. RESULTS: Flexmap parameter evaluations for the factory-calibrated system in clockwise and counter-clockwise rotation direction have shown only minor differences for the overall set of flexmap parameters. High short-term reproducibility of the flexmap parameters has been confirmed by experiments over 10 acquisitions for both directions, resulting in standard deviation values of ≤0.183 mm for translational components and ≤0.0219 deg for rotational components, respectively. A comparison of isocentric and nonisocentric flexmap evaluations showed that the mean differences of the parameter curves reside within their standard deviations, confirming the ability of the proposed calibration method to handle both types of trajectories equally well. Reconstructions of 0.1 mm and 0.25 mm steel wires showed similar results for the isocentric and nonisocentric cases. The full-width at half maximum (FWHM) measure indicates an average improvement of the calibrated reconstruction of 85% over the uncalibrated reconstruction. The contrast of the point spread function (PSF) improved by 310% on average over all experiments. Moreover, a reduced amount of artifacts visible in nonisocentric reconstructions of a head phantom and a line-pair phantom has been achieved by separate application of the 9-DOF flexmap on the geometry described by the independently moving source arm and detector arm. CONCLUSIONS: Using a 9-DOF flexmap approach for correcting the geometry of projections acquired with a device capable of independent movements of the source and panel arms has been shown to be essential for IGRT use cases such as CBCT reconstruction and 2D/3D registration tasks. The proposed pipeline is able to create flexmap curves which are easy to interpret, useful for mechanical description of the device and repetitive quality assurance as well as system-level preventive maintenance. Application of the flexmap has shown improvements of image quality for planar imaging and volumetric imaging which is crucial for patient alignment accuracy.


Asunto(s)
Tomografía Computarizada de Haz Cónico/instrumentación , Movimiento (Física) , Procesamiento de Imagen Asistido por Computador , Reproducibilidad de los Resultados