Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Más filtros

País de afiliación
Intervalo de año de publicación
1.
Appl Opt ; 62(8): C80-C87, 2023 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-37133062

RESUMEN

Breast cancer (BC) molecular subtypes diagnosis involves improving clinical uptake by Fourier transform infrared (FTIR) spectroscopic imaging, which is a non-destructive and powerful technique, enabling label free extraction of biochemical information towards prognostic stratification and evaluation of cell functionality. However, methods of measurements of samples demand a long time to achieve high quality images, making its clinical use impractical because of the data acquisition speed, poor signal to noise ratio, and deficiency of optimized computational framework procedures. To address those challenges, machine learning (ML) tools can facilitate obtaining an accurate classification of BC subtypes with high actionability and accuracy. Here, we propose a ML-algorithm-based method to distinguish computationally BC cell lines. The method is developed by coupling the K-neighbors classifier (KNN) with neighborhood components analysis (NCA), and hence, the NCA-KNN method enables to identify BC subtypes without increasing model size as well as adding additional computational parameters. By incorporating FTIR imaging data, we show that classification accuracy, specificity, and sensitivity improve, respectively, 97.5%, 96.3%, and 98.2%, even at very low co-added scans and short acquisition times. Moreover, a clear distinctive accuracy (up to 9 %) difference of our proposed method (NCA-KNN) was obtained in comparison with the second best supervised support vector machine model. Our results suggest a key diagnostic NCA-KNN method for BC subtypes classification that may translate to advancement of its consolidation in subtype-associated therapeutics.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Espectroscopía Infrarroja por Transformada de Fourier , Análisis de Fourier , Algoritmos , Aprendizaje Automático , Máquina de Vectores de Soporte
2.
Int J Mol Sci ; 23(24)2022 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-36555260

RESUMEN

The mechanisms of action of photobiomodulation (PBM) in oral mucositis (OM) are not completely elucidated. To enlighten the role of PBM in the evolution of epithelial maturity in OM ulcers, the present study evaluated the effect of PBM with red (λ) wavelength of 660 nanometers (nm) and infrared of 780 nm in radio-induced OM wounds on the tongue of rats, eight and twenty days after irradiation with single dose of 20 Gy. The percentage area corresponding to positive staining for cytokeratin 10 (CK10) and 14 (CK14) proteins was evaluated in the epithelial area of the lesions, using an immunohistochemical technique (IHC), 8 and 20 days after the induction of lesions, and compared with an untreated control group. CK10 was significantly more expressed in the group treated with 660 nm PBM. CK14 did not show quantitative differences between the groups evaluated. However, whereas in the groups treated with PBM, CK14 was already restricted to the basal layer of the epithelium, as expected in healthy epithelia, in control group it was also expressed in upper layers of the epithelium. In this work, PBM was able to improve epithelial maturity of the repaired OM wound, especially in the 660 nm group.


Asunto(s)
Terapia por Luz de Baja Intensidad , Estomatitis , Ratas , Animales , Terapia por Luz de Baja Intensidad/métodos , Estomatitis/patología , Estado de Salud
3.
Analyst ; 145(24): 7907-7915, 2021 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-33016272

RESUMEN

Thyroglobulin is a glycoiodoprotein that is produced by thyroid follicular cells; it is stored in follicles in structures known as colloids. The main function of this protein is to stock the hormones triiodothyronine (T3) and thyroxine (T4) until the body requires them. This study aims to demonstrate that infrared spectral imaging with appropriate multivariate analysis can reveal biochemical changes in this glycoprotein. The results achieved herein point out biochemical differences in the colloid samples obtained from normal and goiter patients including glycosylation and changes in the secondary conformational structure. We have presented the first spectral histopathology-based method to detect biochemical differences in thyroid colloids, such as TG iodination, glycosylation, and changes in the secondary structure in normal and goiter patients. The observed changes in the colloids were mainly due to the alterations in amide I and amide II (secondary conformation of proteins) and there is a correlation with different glycosylation between normal and goiter tissues.


Asunto(s)
Bocio , Tiroglobulina , Bocio/diagnóstico por imagen , Humanos , Espectrofotometría Infrarroja , Tiroxina , Triyodotironina
4.
Clin Oral Investig ; 25(3): 1151-1158, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32607827

RESUMEN

OBJECTIVES: This study aimed to investigate the influence of Nd:YAG laser and aluminum oxide sandblasting on the shear bond strength (SBS) of lingual brackets and to optically analyze the behavior of the enamel morphology. MATERIALS AND METHODS: Thirty-five bovines' incisors teeth were divided into 5 groups (n = 7), according to the surface preconditioning: G1, control group; G2, Nd:YAG laser; G3, laser + aluminum oxide sandblasting (Al2O3); G4, Al2O3; and G5, Al2O3 + laser. All groups had lingual brackets bonded and shear debonded after 72 h. SBS values were analyzed, and the enamel morphology was evaluated by optical coherence tomography (OCT) and scanning electron microscope (SEM), before and after preconditioning surface. The optical attenuation coefficient (α) analysis was obtained from OCT images. Data analysis used the ANOVA test, followed by post hoc Tukey, Kruskal Wallis, and post hoc Dunn tests (significance of 5%). RESULTS: The SBS values presented similarly among groups, but the value of α showed statistical difference (p-value = 0.0124) between G3 and G5 with the others. Optical analyses indicated a melting on the enamel that suffered laser irradiation for G2 and G5 and crystal surface disorganization for G4. Sandblasting partially removes the melting of the laser effect (G3). CONCLUSION: The sandblasting is a dispensable step for bonding lingual brackets, and the melting of the enamel after laser irradiation does not compromise the bracket adhesive resistance. CLINICAL RELEVANCE: The Nd:YAG laser became an interesting tool to prevent caries and decrease prevalence of white spot lesions in orthodontic treatments, without systemic effects in patients with genetic high risks of caries.


Asunto(s)
Recubrimiento Dental Adhesivo , Láseres de Estado Sólido , Soportes Ortodóncicos , Óxido de Aluminio , Animales , Bovinos , Esmalte Dental , Humanos , Resistencia al Corte , Propiedades de Superficie
5.
J Prosthodont ; 28(1): e181-e185, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28257161

RESUMEN

PURPOSE: In clinical prosthetics procedures, including endodontics and post fixation, the presence of a smear layer can reduce the post bond strength. An Er,Cr:YSGG laser, which emits at 2780 nm, can promote a smear-layer-free surface due to the ablation process. Considering these aspects, the purpose of this work was to evaluate the influence of Er,Cr:YSGG laser irradiation using either a radial or an axial fiber tip on the bond strength of three resin cements to the fiber-reinforced composite posts. MATERIALS AND METHODS: Ninety recently extracted single rooted human teeth had their root canal instrumented and were randomly distributed into nine experimental groups, in which three resin cements (total-etching Variolink II, self-etching Panavia F, and self-adhesive RelyX Unicem Aplicap) and three root canal treatments (no treatment, laser irradiation using the radial fiber tip, laser irradiation using the axial fiber tip) were used. Specimens were then sectioned into three sections (cervical, middle, and apical thirds) with two slices on each section. A push-out test was performed on each slice, and the values were recorded as MPa. The push-out data were analyzed by a Ryan-Joiner normality test followed by a two-way ANOVA test and Tukey pairwise comparison. The statistical analysis was performed on each third section separately, with a 5% significance level. RESULTS: Laser irradiation with axial fiber tip significantly increased the post bond strength of RelyX Unicem Aplicap on middle third of specimens (p < 0.001) when compared to other root canal treatments (unlased or irradiated with radial tip). Considering the Panavia resin cement, laser irradiation with either axial or radial tips promoted a significant increase on the post bond strength of middle third when compared to unlased specimens (p < 0.001); however, laser irradiation did not influence the post bond strength of Variolink resin cement. CONCLUSIONS: The use of the Er,Cr:YSGG laser for clinical prosthetics procedures enhances the post bond strength of Panavia and RelyX Unicem Aplicap resin cements, mainly at middle third of roots, and does not interfere with the bond strength of Variolink resin cement. For the RelyX Unicem Aplicap system, the use of axial tip is most advantageous and can be recommended for future clinical application.


Asunto(s)
Recubrimiento Dental Adhesivo/métodos , Láseres de Estado Sólido/uso terapéutico , Cementos de Resina/química , Cementos de Resina/efectos de la radiación , Tratamiento del Conducto Radicular/instrumentación , Tratamiento del Conducto Radicular/métodos , Raíz del Diente/efectos de la radiación , Grabado Dental/métodos , Cavidad Pulpar/efectos de la radiación , Análisis del Estrés Dental , Vidrio , Humanos , Ensayo de Materiales , Técnica de Perno Muñón/instrumentación , Dosis de Radiación , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Auto-Curación de Resinas Dentales , Estrés Mecánico
6.
Lasers Med Sci ; 32(4): 873-880, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28293873

RESUMEN

This study aims to evaluate the association between Nd:YAG laser (with and without a photoabsorber) and two desensitizing dentifrices containing 15% NovaMin or 8% arginine, as potential treatments for dentin hypersensitivity (DH). DH was simulated by EDTA application for 2 min. Specimens were then analyzed with an environmental scanning electron microscope (ESEM) to ensure open dentin tubules (ODT), counted by using ImageJ software. Specimens were randomized into eight groups (n = 10): Laser (L), Laser+Photoabsorber (LP), Arginine (A), Arginine+Laser (AL), Arginine+Laser+Photoabsorber (ALP), NovaMin (N), NovaMin+Laser (NL), and NovaMin+Laser+Photoabsorber (NLP). Laser irradiation was performed with 1 W, 100 mJ, 10 Hz, ≅85 J/cm2; 4 irradiations of 10 s each, with 10 s intervals between them. After treatment, specimens were again analyzed by ESEM and submitted to erosive/abrasive cycling for 5 days. A final ESEM analysis was performed. Data were analyzed with two-way repeated measure ANOVA and Tukey tests (α = 0.05). After treatment, groups N, NL, and NLP presented the lower number of ODT, but they did not different from LP, ALP, and AL. Group A presented the highest number of ODT and it did not differ from group L. Groups L, AL, ALP, and LP presented intermediate results, without differing from each other. After cycling, group A presented the highest number of ODT and did not differ significantly from the other groups, except NLP. None of the associations tested presented better tubule occlusion than NovaMin by itself. Arginine was the only treatment that presented improved tubule occlusion when associated with Nd:YAG laser.


Asunto(s)
Dentífricos/efectos de la radiación , Desensibilizantes Dentinarios/farmacología , Sensibilidad de la Dentina/radioterapia , Láseres de Estado Sólido/uso terapéutico , Dentina/efectos de la radiación , Dentina/ultraestructura , Vidrio , Humanos
7.
Am J Dent ; 28(5): 297-302, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26714348

RESUMEN

PURPOSE: To evaluate the effect of desensitizing dentifrices on dentin erosive wear, using a 5-day erosion-abrasion-remineralization cycling model. The effect of the dentifrices on dentin's tubule occlusion was also investigated. METHODS: 30 samples of root dentin were randomly divided into three groups (n = 10): (1) Colgate Total 12 Clean Mint (control, 1,450 ppm F); (2) Colgate Sensitive Pro-Relief (1,450 ppm F, Pro-Argin); and (3) Sensodyne Repair&Protect (1,450 ppm F, Novamin). Erosion was performed with a cola drink, for 5 minutes, 4x/day. Toothbrushing with the slurry dentifrices (1:2) was performed 2x/day, with electric toothbrushes, using standard pressure for 15 seconds. Surface loss (SL) was determined with optical profilometry at baseline and after the first, third and fifth days of cycling. Before treatment and in the end of the cycling, the amount of opened dentin tubules per area was evaluated in three randomly selected specimens from each group, by environmental scanning electron microscopy. The relative dentin abrasitivity (RDA) of the dentifrices was also measured. Data were statistically analyzed (α = 0.05). RESULTS: All the dentifrices showed a progressive increase in SL over time. However, no significant differences in SL among the dentifrices were observed at any time studied. Sensodyne Repair&Protect significantly reduced the number of opened dentin tubules when compared to the other groups. Colgate Total 12 Clean Mint showed the highest RDA, followed by Sensodyne Repair&Protect and then by Colgate Sensitive Pro-Relief. The desensitizing dentifrices tested produced a similar rate of erosive dentin wear to the conventional dentifrice; however, only Sensodyne Repair&Protect was able to promote tubule occlusion.


Asunto(s)
Dentífricos/farmacología , Desensibilizantes Dentinarios/farmacología , Dentina/efectos de los fármacos , Desgaste de los Dientes/etiología , Arginina/farmacología , Carbonato de Calcio/farmacología , Bebidas Gaseosas/efectos adversos , Dentina/ultraestructura , Combinación de Medicamentos , Fluoruros/farmacología , Vidrio , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Nitratos/farmacología , Fosfatos/farmacología , Distribución Aleatoria , Ácido Silícico/farmacología , Abrasión de los Dientes/etiología , Erosión de los Dientes/etiología , Remineralización Dental , Raíz del Diente/efectos de los fármacos , Raíz del Diente/ultraestructura , Cepillado Dental/instrumentación , Pastas de Dientes/farmacología
8.
Spectrochim Acta A Mol Biomol Spectrosc ; 310: 123941, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38290283

RESUMEN

Fourier-transform infrared spectroscopy (FTIR) is a powerful, non-destructive, highly sensitive and a promising analytical technique to provide spectrochemical signatures of biological samples, where markers like carbohydrates, proteins, and phosphate groups of DNA can be recognized in biological micro-environment. However, method of measurements of large cells need an excessive time to achieve high quality images, making its clinical use difficult due to speed of data-acquisition and lack of optimized computational procedures. To address such challenges, Machine Learning (ML) based technologies can assist to assess an accurate prognostication of breast cancer (BC) subtypes with high performance. Here, we applied FTIR spectroscopy to identify breast cancer subtypes in order to differentiate between luminal (BT474) and non-luminal (SKBR3) molecular subtypes. For this reason, we tested multivariate classification technique to extract feature information employing three-dimension (3D)-discriminant analysis approach based on 3D-principle component analysis-linear discriminant analysis (3D-PCA-LDA) and 3D-principal component analysis-quadratic discriminant analysis (3D-PCA-QDA), showing an improvement in sensitivity (98%), specificity (94%) and accuracy (98%) parameters compared to conventional unfolded methods. Our results evidence that 3D-PCA-LDA and 3D-PCA-QDA are potential tools for discriminant analysis of hyperspectral dataset to obtain superior classification assessment.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Análisis Discriminante , Análisis de Componente Principal , Aprendizaje Automático , Microambiente Tumoral
9.
Comput Methods Programs Biomed ; 247: 108100, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38442622

RESUMEN

BACKGROUND AND OBJECTIVE: The thyroid is a gland responsible for producing important body hormones. Several pathologies can affect this gland, such as thyroiditis, hypothyroidism, and thyroid cancer. The visual histological analysis of thyroid specimens is a valuable process that enables pathologists to detect diseases with high efficiency, providing the patient with a better prognosis. Existing computer vision systems developed to aid in the analysis of histological samples have limitations in distinguishing pathologies with similar characteristics or samples containing multiple diseases. To overcome this challenge, hyperspectral images are being studied to represent biological samples based on their molecular interaction with light. METHODS: In this study, we address the acquisition of infrared absorbance spectra from each voxel of histological specimens. This data is then used for the development of a multiclass fully-connected neural network model that discriminates spectral patterns, enabling the classification of voxels as healthy, cancerous, or goiter. RESULTS: Through experiments using the k-fold cross-validation protocol, we obtained an average accuracy of 93.66 %, a sensitivity of 93.47 %, and a specificity of 96.93 %. Our results demonstrate the feasibility of using infrared hyperspectral imaging to characterize healthy tissue and thyroid pathologies using absorbance measurements. The proposed deep learning model has the potential to improve diagnostic efficiency and enhance patient outcomes.


Asunto(s)
Redes Neurales de la Computación , Neoplasias de la Tiroides , Humanos , Inteligencia Artificial , Diagnóstico por Imagen , Neoplasias de la Tiroides/diagnóstico por imagen
10.
Clin Oral Investig ; 17(1): 87-95, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22402617

RESUMEN

OBJECTIVES: This randomized split-mouth clinical trial was designed to evaluate the efficacy of scaling and root planing associated to the high-intensity diode laser on periodontal therapy by means of clinical parameters and microbial reduction. MATERIALS AND METHODS: A total of 36 chronic periodontitis subjects, of both genders, were selected. One pair of contralateral single-rooted teeth with pocket depth >5 mm was chosen from each subject. All patients received non-surgical periodontal treatment, after which the experimental teeth were designated to either test or control groups. Both teeth received scaling, root planing and coronal polishing (SRP) and teeth assigned to the test group (SRP + DL) were irradiated with the 808 ± 5 nm diode laser, for 20 s, in two isolated appointments, 1 week apart. The laser was used in the continuous mode, with 1.5 W and power density of 1,193.7 W/cm(2). Clinical and microbiological data were collected at baseline, 6 weeks and 6 months after therapy. RESULTS: There was a significant improvement of all the clinical parameters-clinical attachment level (CAL), probing depth (PD), plaque index (PI) and Bleeding on Probing (BOP)-for both groups (P < 0.001), with no statistical difference between them at the 6 weeks and the 6 months examinations. As for microbiological analysis, a significant reduction after 6 weeks (P > 0.05) was observed as far as colony forming units (CFU) is concerned, for both groups. As for black-pigmented bacteria, a significant reduction was observed in both groups after 6 months. However, the difference between test and control groups was not significant. There was no association between group and presence of Porphyromonas gingivalis, Prevotella intermedia and Aggregatibacter actinomycetemcomitans at any time of the study. CONCLUSIONS: After 6 months of evaluation, the high-intensity diode laser has not shown any additional benefits to the conventional periodontal treatment. CLINICAL RELEVANCE: The high intensity diode laser did not provide additional benefits to non-surgical periodontal treatment. More studies are necessary to prove the actual need of this type of laser in the periodontal clinical practice.


Asunto(s)
Periodontitis Crónica/terapia , Raspado Dental/métodos , Terapia por Láser/métodos , Láseres de Semiconductores/uso terapéutico , Aplanamiento de la Raíz/métodos , Adulto , Aggregatibacter actinomycetemcomitans/aislamiento & purificación , Carga Bacteriana/efectos de los fármacos , Carga Bacteriana/efectos de la radiación , Periodontitis Crónica/microbiología , Periodontitis Crónica/radioterapia , Terapia Combinada , Placa Dental/microbiología , Índice de Placa Dental , Profilaxis Dental/métodos , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pérdida de la Inserción Periodontal/radioterapia , Pérdida de la Inserción Periodontal/terapia , Índice Periodontal , Bolsa Periodontal/radioterapia , Bolsa Periodontal/terapia , Porphyromonas gingivalis/aislamiento & purificación , Prevotella intermedia/aislamiento & purificación , Factores de Tiempo , Resultado del Tratamiento
11.
Spectrochim Acta A Mol Biomol Spectrosc ; 290: 122259, 2023 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-36584643

RESUMEN

The development of novel platforms for non-invasive continuous glucose monitoring applied in the screening and monitoring of diabetes is crucial to improve diabetes surveillance systems. Attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy of urine can be an alternative as a sustainable, label-free, fast, non-invasive, and highly sensitive analysis to detect changes in urine promoted by diabetes and insulin treatment. In this study, we used ATR-FTIR to evaluate the urinary components of non-diabetic (ND), diabetic (D), and diabetic insulin-treated (D + I) rats. As expected, insulin treatment was capable to revert changes in glycemia, 24-h urine collection volume, urine creatinine, urea, and glucose excretion promoted by diabetes. Several differences in the urine spectra of ND, D, and D + I were observed, with urea, creatinine, and glucose analytes being related to these changes. Principal components analysis (PCA) scores plots allowed for the discrimination of ND and D + I from D with an accuracy of âˆ¼ 99 %. The PCA loadings associated with PC1 confirmed the importance of urea and glucose vibrational modes for this discrimination. Univariate analysis of second derivative spectra showed a high correlation (r: 0.865, p < 0.0001) between the height of 1074 cm-1 vibrational mode with urinary glucose concentration. In order to estimate the amount of glucose present in the infrared spectra from urine, multivariate curve resolution-alternating least square (MCR-ALS) was applied and a higher predicted concentration of glucose in the urine was observed with a correlation of 78.9 % compared to urinary glucose concentration assessed using enzyme assays. In summary, ATR-FTIR combined with univariate and multivariate chemometric analyses provides an innovative, non-invasive, and sustainable approach to diabetes surveillance.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Insulinas , Ratas , Animales , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Creatinina , Glucemia , Glucosa/análisis , Urea
12.
Lasers Med Sci ; 27(4): 703-11, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21732113

RESUMEN

Little is known about the benefits of low-level laser therapy (LLLT) on improvement of stability of dental implants. The aim of this randomized clinical study was to assess the LLLT effect on implants stability by means of resonance frequency analysis (RFA). Thirty implants were distributed bilaterally in the posterior mandible of eight patients. At the experimental side, the implants were submitted to LLLT (830 nm, 86 mW, 92.1 J/cm(2), 0.25 J, 3 s/point, at 20 points), and on the control side, the irradiation was simulated (placebo). The first irradiation was performed in the immediate postoperative period, and it was repeated every 48 h in the first 14 days. The initial implant stability quotient (ISQ) of the implants was measured by means of RFA. New ISQ measurements were made after 10 days, 3, 6, 9, and 12 weeks. The initial ISQ values ranged from 65-84, with a mean of 76, undergoing a significant drop in stability from the 10th day to the 6th week in the irradiated group, and presenting a gradual increase from the 6th to the 12th week. The highest ISQ values were observed on the 10th day in the irradiated group, and the lowest in the 6th week in both groups. Under the conditions of this study, no evidence was found of any effect of LLLT on the stability of the implants when measured by RFA. Since high primary stability and good bone quality are of major relevancy for a rigid bone-implant interface, additional LLLT may have little impact macroscopically.


Asunto(s)
Implantación Dental Endoósea/métodos , Implantes Dentales , Terapia por Luz de Baja Intensidad/métodos , Mandíbula/cirugía , Adulto , Análisis del Estrés Dental , Retención de Dentadura , Método Doble Ciego , Femenino , Estudios de Seguimiento , Humanos , Análisis de Intención de Tratar , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Oseointegración , Adulto Joven
13.
Polymers (Basel) ; 14(8)2022 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-35458342

RESUMEN

The localized surface plasmon resonance (LSPR) due to light-particle interaction and its dependence on the surrounding medium have been widely manipulated for sensing applications. The sensing efficiency is governed by the refractive index-based sensitivity (ηRIS) and the full width half maximum (FWHM) of the LSPR spectra. Thereby, a sensor with high precision must possess both requisites: an effective ηRIS and a narrow FWHM of plasmon spectrum. Moreover, complex nanostructures are used for molecular sensing applications due to their good ηRIS values but without considering the wide-band nature of the LSPR spectrum, which decreases the detection limit of the plasmonic sensor. In this article, a novel, facile and label-free solution-based LSPR immunosensor was elaborated based upon LSPR features such as extinction spectrum and localized field enhancement. We used a 3D full-wave field analysis to evaluate the optical properties and to optimize the appropriate size of spherical-shaped gold nanoparticles (Au NPs). We found a change in Au NPs' radius from 5 nm to 50 nm, and an increase in spectral resonance peak depicted as a red-shift from 520 nm to 552 nm. Using this fact, important parameters that can be attributed to the LSPR sensor performance, namely the molecular sensitivity, FWHM, ηRIS, and figure of merit (FoM), were evaluated. Moreover, computational simulations were used to assess the optimized size (radius = 30 nm) of Au NPs with high FoM (2.3) and sharp FWHM (44 nm). On the evaluation of the platform as a label-free molecular sensor, Campbell's model was performed, indicating an effective peak shift in the adsorption of the dielectric layer around the Au NP surface. For practical realization, we present an LSPR sensor platform for the identification of dengue NS1 antigens. The results present the system's ability to identify dengue NS1 antigen concentrations with the limit of quantification measured to be 0.07 µg/mL (1.50 nM), evidence that the optimization approach used for the solution-based LSPR sensor provides a new paradigm for engineering immunosensor platforms.

14.
Clin Exp Dent Res ; 8(6): 1655-1663, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36218194

RESUMEN

OBJECTIVES: The primary aim of this ex vivo study was to evaluate thermal damage and cutting efficiency of micro and super pulsed diode lasers. The secondary aim was to suggest a guideline to perform simple surgical excisions adequate for histopathological evaluation. MATERIAL AND METHODS: Ten groups of 10 specimens of pig tongues were excised using a blade (G1), a micro pulsed (G2-G9), and a super pulsed diode (G10) lasers. Different output power, pulse duration, pulse interval, and duty cycle were tested. Quantitative measures of thermal damage and excision times were recorded. Statistical analysis was performed at a significance level of 5%. RESULTS: The control group (G1) presented no thermal damage. Within the laser groups (G2-G10), no statistically significant differences in depth of thermal damage (µm) were noted. G3 showed significantly less area of thermal damage (mm2 ) when compared with G7 and G9 (p < .05). The median excision time of the control group and super pulsed diode laser group were significantly lower (p < .001) than the micro pulsed diode laser groups. CONCLUSIONS: The cutting efficiency of the super pulsed diode laser is comparable to traditional blade, and with appropriate parameters, these lasers can produce predictable surgical outcomes with less collateral damage.


Asunto(s)
Terapia por Láser , Láseres de Semiconductores , Porcinos , Animales , Láseres de Semiconductores/uso terapéutico , Terapia por Láser/efectos adversos , Lengua
15.
Photodiagnosis Photodyn Ther ; 38: 102796, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35263669

RESUMEN

Triple-negative breast cancer (TNBC) overexpresses the Epidermal Growth Factor Receptor (EGFR), a characteristic of different types of tumors, linked to worse disease prognosis and risk of recurrence. Conventional treatments are also aggressive and can be morbid.. Therefore, t improvement and development of new methods are notorious. Photodynamic Therapy (PDT) is an effective method for treating different types of cancer by using light radiation to activate a photosensitizing agent (drug) in molecular oxygen presence, promoting cell death., Improving drug uptake in target cells could contribute to PDT efficiency. Accordingly, we developed a bifunctional nanoprobe (BN), used in PDT as a a treatment method in vivo against breast cancer. The BN uses gold nanoparticles with active targeting through the Epidermal Growth Factor (EGF) protein and Chlorine e6 (Ce6) carriers. We evaluated the therapeutic efficacy of in vivo xenograft in 4 groups: Saline, BN, Ce6+PDT, and BN+PDT. As a result, we observed that the BN+PDT group exhibited an excellent effect with greater selectivity to tumor tissue and tissue damage when compared to the Saline, BN, and Ce6+PDT groups. The results indicate a potential impact on breast cancer treatment in vivo.. In conclusion, our data propose that the BN developed heightened PDT efficacy through cellular DNA repair effects and tumor microenvironment.


Asunto(s)
Clorofilidas , Nanopartículas del Metal , Nanopartículas , Fotoquimioterapia , Porfirinas , Neoplasias de la Mama Triple Negativas , Línea Celular Tumoral , Oro/farmacología , Oro/uso terapéutico , Xenoinjertos , Humanos , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/farmacología , Fármacos Fotosensibilizantes/uso terapéutico , Neoplasias de la Mama Triple Negativas/tratamiento farmacológico , Microambiente Tumoral
16.
Nanomaterials (Basel) ; 12(3)2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-35159853

RESUMEN

There is already a societal awareness of the growing impact of nanoscience and nanotechnology, with nanomaterials (with at least one dimension less than 100 nm) now incorporated in items as diverse as mobile phones, clothes or dentifrices. In the healthcare area, nanoparticles of biocompatible materials have already been used for cancer treatment or bioimaging enhancement. Nanotechnology in dentistry, or nanodentistry, has already found some developments in dental nanomaterials for caries management, restorative dentistry and orthodontic adhesives. In this review, we present state-of-the-art scientific development in nanodentistry with an emphasis on two imaging techniques exploiting nanomaterials: optical coherence tomography (OCT) and photoacoustic imaging (PAI). Examples will be given using OCT with nanomaterials to enhance the acquired imaging, acting as optical clearing agents for OCT. A novel application of gold nanoparticles and nanorods for imaging enhancement of incipient occlusal caries using OCT will be described. Additionally, we will highlight how the OCT technique can be properly managed to provide imaging with spatial resolution down to 10's-100's nm resolution. For PAI, we will describe how new nanoparticles, namely TiN, prepared by femtosecond laser ablation, can be used in nanodentistry and will show photoacoustic microscopy and tomography images for such exogenous agents.

17.
PLoS One ; 16(7): e0254217, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34234361

RESUMEN

OBJECTIVE: This in vitro study characterized and monitored, by Optical Coherence Tomography (OCT) and Fourier Transformed Infrared Spectroscopy (FTIR), the effects of the association of acidulated phosphate fluoride gel (APF-gel) and Nd:YAG (neodymiun:yttrium-aluminum-garnet) laser, as sequencial treatments, in the prevention of incipient enamel caries lesions. METHODS: 120 human enamel samples were randomized into 3 groups (n = 40): APF-gel (1.23% F-, 4 min.); Laser+APF (Nd:YAG laser irradiation-0.6W, 84.9J/cm2, 10Hz, followed by APF-gel); and APF+Laser (APF-gel followed by laser irradiation). The samples were subjected to a 15-day pH-cycling, evaluated by OCT (quantification of optical attenuation coefficient-OAC) and FTIR (analysis of carbonate and phosphate content) before treatments, after treatments, and on the 5th, 10th and 15th days of pH-cycling. The statistical analysis was performed (α = 5%). RESULTS: The Optical Attenuation Coefficient (OAC) assessed by OCT increases with the progression of demineralization, and the Laser+APF presented the highest values of OAC in 10th and 15th days of pH-cycling. Nd:YAG decreased the carbonate content after treatment regardless of the application order of the APF-gel, while APF-gel did not interfere in the composition of enamel. The carbonate content was also changed in the first 5 days of the pH-cycling in all groups. CONCLUSION: Nd:YAG laser irradiation before or after the application of APF-gel did not influence the appearance of incipient caries lesions, showing no synergistic effect. Regardless of the application order of the APF-gel, laser irradiation reduces the carbonate content of the enamel, which also changes during the demineralization process. However, irradiation before the application of APF-gel increased the speed of progression of the lesions, which positively impacts public health as it can prevent caries disease, even in high risk individuals. OCT and FTIR are suitable for assessing this effect.


Asunto(s)
Fluoruro de Fosfato Acidulado/administración & dosificación , Caries Dental/prevención & control , Fluoruros/administración & dosificación , Susceptibilidad a Caries Dentarias/fisiología , Humanos , Láseres de Estado Sólido/uso terapéutico , Microscopía Electrónica de Rastreo/métodos , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Tomografía de Coherencia Óptica/métodos , Desmineralización Dental/prevención & control , Erosión de los Dientes/prevención & control
18.
Braz Dent J ; 32(6): 8-15, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35019022

RESUMEN

The aim of this study was to evaluate surface wear, presence of microcracks and surface irregularities of WaveOne (WO) and WaveOne Gold (WOG) instruments before and after multiple uses. Eight Primary instruments of the WO and WOG systems were evaluated, each one was used to prepare six mesial canals of extracted human mandibular molars. The surface of the instruments was evaluated before use (T0), after instrumentation of three (T1) and six (T2) root canals. Surface wear was analyzed using a three-dimensional optical profiler and the presence of microcracks and surface irregularities were evaluated using a tabletop scanning electron microscopy. The Friedman test was used to assess surface wear and Kruskal-Wallis test to evaluate the presence of microcracks and surface irregularities, with a 5% significance level. There was a significant increase in wear in both groups at T2, compared to T0 (p=0.0003). The surface wear after instrumentation of six canals (T2-T0) was statistically greater in the WOG group, than in the WO group (p=0.02), where the presence of microcracks was significantly greater and increased after multiple uses (p<0.05). The presence of surface irregularities in the cutting blade before and after use was statistically greater in the WOG group than WO group (p<0.05). Wear of the cutting blade, microcracks and surface irregularities were observed on the surface topography of all the instruments after multiple uses. These surface changes may affect the cutting efficiency of WOG files and increase the risk of fracture of WO files.


Asunto(s)
Níquel , Preparación del Conducto Radicular , Instrumentos Dentales , Cavidad Pulpar , Diseño de Equipo , Calor , Humanos , Titanio
19.
J Appl Oral Sci ; 29: e20200736, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33825753

RESUMEN

OBJECTIVE: To evaluate the efficacy of Nd:YAG laser associated with calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion after erosive/abrasive challenges. METHODOLOGY: Dentin specimens were exposed to 17% ethylene diamine tetra-acetic acid (EDTA) solution for 5 min and randomly allocated into five groups: G1, control (no treatment); G2, Nd:YAG laser (1 W, 10 Hz, 100 mJ, 85 J/cm2); G3, Laser + TeethmateTM Desensitizer; G4, Laser + Desensibilize Nano P; and G5, Laser+Nupro®. Specimens underwent a 5-day erosion-abrasion cycling. Hydraulic conductance was measured post-EDTA, post-treatment, and post-cycling. Post-treatment and post-cycling permeability (%Lp) was calculated based on post-EDTA measurements, considered 100%. Open dentin tubules (ODT) were calculated at the abovementioned experimental moments using scanning electron microscopy and ImageJ software (n=10). Data were analyzed using two-way repeated measures ANOVA and Tukey's test (α=0.05). RESULTS: G1 presented the highest %Lp post-treatment of all groups (p<0.05), without significantly differences among them. At post-cycling, %Lp significantly decreased in G1, showed no significant differences from post-treatment in G3 and G4, and increased in G2 and G5, without significant differences from G1 (p>0.05). We found no significant differences in ODT among groups (p>0.05) post-EDTA. At post-treatment, treated groups did not differ from each other, but presented lower ODT than G1 (p<0.001). As for post-cycling, we verified no differences among groups (p>0.05), although ODT was significantly lower for all groups when compared to post-EDTA values (p<0.001). CONCLUSION: All treatments effectively reduced dentin permeability and promoted tubule occlusion after application. COMBINING ND: YAG laser with calcium-phosphate pastes did not improve the laser effect. After erosive-abrasive challenges, treatments presented no differences when compared to the control.


Asunto(s)
Desensibilizantes Dentinarios , Láseres de Estado Sólido , Calcio/farmacología , Dentina , Permeabilidad de la Dentina , Láseres de Estado Sólido/uso terapéutico , Microscopía Electrónica de Rastreo
20.
Lasers Med Sci ; 25(6): 881-9, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19802717

RESUMEN

The objective of this study was to evaluate the influence of various pulse widths with different energy parameters of erbium:yttrium-aluminum-garnet (Er:YAG) laser (2.94 mum) on the morphology and microleakage of cavities restored with composite resin. Identically sized class V cavities were prepared on the buccal surfaces of 54 bovine teeth by high-speed drill (n = 6, control, group 1) and prepared by Er:YAG laser (Fidelis 320A, Fotona, Slovenia) with irradiation parameters of 350 mJ/ 4 Hz or 400 mJ/2 Hz and pulse width: group 2, very short pulse (VSP); group 3, short pulse (SP); group 4, long pulse (LP); group 5, very long pulse (VLP). All cavities were filled with composite resin (Z-250-3 M), stored at 37 degrees C in distilled water, polished after 24 h, and thermally stressed (700 cycles/5-55 degrees C). The teeth were impermeabilized, immersed in 50% silver nitrate solution for 8 h, sectioned longitudinally, and exposed to Photoflood light for 10 min to reveal the stain. The leakage was evaluated under stereomicroscope by three different examiners, in a double-blind fashion, and scored (0-3). The results were analyzed by Kruskal-Wallis test (P > 0.05) and showed that there was no significant differences between the groups tested. Under scanning electron microscopy (SEM) the morphology of the cavities prepared by laser showed irregular enamel margins and dentin internal walls, and a more conservative pattern than that of conventional cavities. The different power settings and pulse widths of Er:YAG laser in cavity preparation had no influence on microleakage of composite resin restorations.


Asunto(s)
Preparación de la Cavidad Dental/métodos , Láseres de Estado Sólido/uso terapéutico , Terapia por Luz de Baja Intensidad/métodos , Animales , Bovinos , Resinas Compuestas , Esmalte Dental/efectos de la radiación , Esmalte Dental/ultraestructura , Filtración Dental/prevención & control , Restauración Dental Permanente/métodos , Dentina/efectos de la radiación , Dentina/ultraestructura , Técnicas In Vitro , Microscopía Electrónica de Rastreo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA