Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
BMC Cardiovasc Disord ; 21(1): 214, 2021 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-33906609

RESUMEN

BACKGROUND: To clarify the appropriate initial dosage of heparin during radiofrequency catheter ablation (RFCA) in patients with atrial fibrillation (AF) receiving uninterrupted nonvitamin K antagonist oral anticoagulant (NOAC) treatment. METHODS: A total of 187 consecutive AF patients who underwent their first RFCA in our center were included. In the warfarin group (WG), an initial heparin dose of 100 U/kg was administered (control group: n = 38). The patients who were on NOACs were randomly divided into 3 NOAC groups (NG: n = 149), NG110, NG120, and NG130, and were administered initial heparin doses of 110 U/kg, 120 U/kg, and 130 U/kg, respectively. During RFCA, the activated clotting time (ACT) was measured every 15 min, and the target ACT was maintained at 250-350 s by intermittent heparin infusion. The baseline ACT and ACTs at each 15-min interval, the average percentage of measurements at the target ACT, and the incidence of periprocedural bleeding and thromboembolic complications were recorded and analyzed. RESULTS: There was no significant difference in sex, age, weight, or baseline ACT among the four groups. The 15 min-ACT, 30 min-ACT, and 45 min-ACT were significantly longer in the WG than in NG110 and NG120. However, no significant difference in 60 min-ACT or 75 min-ACT was detected. The average percentages of measurements at the target ACT in NG120 (82.2 ± 23.6%) and NG130 (84.8 ± 23.7%) were remarkably higher than those in the WG (63.4 ± 36.2%, p = 0.007, 0.003, respectively). These differences were independent of the type of NOAC. The proportion of ACTs in 300-350 s in NG130 was higher than in WG (32.4 ± 31.8 vs. 34.7 ± 30.6, p = 0.735). Severe periprocedural thromboembolic and bleeding complications were not observed. CONCLUSIONS: For patients with AF receiving uninterrupted NOAC treatment who underwent RFCA, an initial heparin dosage of 120 U/kg or 130 U/kg can provide an adequate intraprocedural anticoagulant effect, and 130 U/kg allowed ACT to reach the target earlier. TRIAL REGISTRATION: Registration number: ChiCTR1800016491, First Registration Date: 04/06/2018 (Chinese Clinical Trial Registry http://www.chictr.org.cn/index.aspx ).


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/cirugía , Ablación por Catéter , Dabigatrán/administración & dosificación , Heparina/administración & dosificación , Rivaroxabán/administración & dosificación , Accidente Cerebrovascular/prevención & control , Tromboembolia/prevención & control , Warfarina/administración & dosificación , Administración Oral , Anciano , Anticoagulantes/efectos adversos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Ablación por Catéter/efectos adversos , China , Dabigatrán/efectos adversos , Método Doble Ciego , Esquema de Medicación , Monitoreo de Drogas , Femenino , Heparina/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Hemorragia Posoperatoria/inducido químicamente , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Rivaroxabán/efectos adversos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Tromboembolia/diagnóstico , Tromboembolia/etiología , Factores de Tiempo , Resultado del Tratamiento , Warfarina/efectos adversos , Tiempo de Coagulación de la Sangre Total
2.
Pacing Clin Electrophysiol ; 44(7): 1193-1199, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34080696

RESUMEN

OBJECTIVE: To investigate the efficacy and safety of His-bundle pacing (HBP) compared with the traditional biventricular pacing (BVP) on patients with brady-arrhythmias, who suffer from permanent atrial fibrillation (AF) and heart failure with reduced ejection fraction (HFrEF). METHODS: All patients with brady-arrhythmias, permanent AF and HFrEF were continuously enrolled from January 2017 to July 2019 and followed up for at least 12 months. The differences in QRS duration (QRSd), New York Heart Association (NYHA) classification, left ventricular ejection fraction (LVEF), tricuspid regurgitation grade, mitral regurgitation grade, left ventricular end-diastolic diameter (LVEDD), and left atrial size were compared. RESULTS: A total of 52 patients were enrolled: 37 patients were with HBP and 15 patients with BVP. There was no electrode dislodged, perforation, infection or thrombosis during the follow-up of 18.12 ± 4.45 months. The success rate for HBP implantation was 88.10%. The capture threshold of his-bundle and the threshold of the left ventricular lead remained stable during follow-up. LVEF increased to higher than 50% in 11 patients with HBP (29.73%). The NYHA classification (both p < .001), LVEF (both p < .001) and LVEDD improved significantly during the follow-up in both groups. NYHA (p = .030), LVEF (p = .013), and LVEDD (p = .003) improved in patients with HBP compared with BVP. CONCLUSION: HBP was safe and more effective in improving the cardiac function and remodeling in patients with brady-arrhythmias, permanent AF and HFrEF compared with BVP.


Asunto(s)
Fibrilación Atrial/complicaciones , Bradicardia/etiología , Bradicardia/terapia , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/complicaciones , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/fisiopatología , Fascículo Atrioventricular/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Femenino , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Resultado del Tratamiento
3.
Zhonghua Xin Xue Guan Bing Za Zhi ; 41(5): 387-9, 2013 May.
Artículo en Zh | MEDLINE | ID: mdl-24021120

RESUMEN

OBJECTIVE: The outcome of atrial fibrillation patients with genetic mutations post ablation was not well evaluated. METHODS AND RESULTS: Three atrial fibrillation patients with evidence of mutations in KCNA5 and NPPA post successful circumferential pulmonary vein ablation were included. Mutation in KCNA5 was found in one male patient with paroxysmal atrial fibrillation. He was free of atrial fibrillation post ablation after 46 months follow-up. Mutations in NPPA were found in two male patients with persistent atrial fibrillation and they were free from atrial fibrillation after 64 months and 38 months follow-up post circumferential pulmonary vein ablation, roof line and mitral isthmus line ablation. CONCLUSION: Satisfactory long term results are observed in atrial fibrillation patients with KCNA5 and NPPA mutations post circumferential pulmonary vein ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Factor Natriurético Atrial/genética , Ablación por Catéter , Canal de Potasio Kv1.5/genética , Anciano , Fibrilación Atrial/genética , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Mutación , Resultado del Tratamiento
4.
Front Cardiovasc Med ; 10: 1105342, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37273877

RESUMEN

Background: The relationship between cumulative non-high-density lipoprotein cholesterol (non-HDL-C) burden and atherosclerotic cardiovascular disease (ASCVD) remains unclear. Objective: To prospectively examine the association between cumulative non-HDL-C burden and ASCVD risk in the Kailuan cohort of China. Methods: A total of 49,679 subjects who were free of ASCVD participated in three consecutive examinations in 2006, 2008 and 2010 were enrolled. Duration and concentration of cumulative exposure to non-HDL-C (cumNon-HDL-C) were respectively used to estimate the extent of cumulative non-HDL-C burden. The participants were divided into four groups according to durations of cumNon-HDL-C (0, 2, 4 and 6 years) and five groups according to the quintiles of cumNon-HDL-C concentration (<10.93, 10.93-12.68, 12.69-14.32, 14.33-16.72 and ≥16.73 mmol/L). Cox regression models were used to analyze the influence of cumulative non-HDL-C burden on ASCVD risk. Results: We identified 1,134 incident ASCVD cases during a mean of 4.89 years of follow-up. Multivariable adjusted analysis revealed that compared with no exposure, cumNon-HDL-C duration 2, 4 and 6 years increased ASCVD risk by 26% (HR: 1.26, 95% CI: 1.07-1.47), 56% (HR: 1.56, 95% CI: 1.31-1.86) and 91% (HR: 1.91, 95% CI: 1.59-2.31) respectively; The hazard ratios (HRs) for the fourth and fifth versus lowest quintile of cumNon-HDL-C concentration were 1.25 and 1.72 for ASCVD. Each standard deviation increment in cumNon-HDL-C concentration was associated with a 10% increased risk of ASCVD. Conclusion: Long-term and higher cumNon-HDL-C were all significantly associated with an increased risk of ASCVD independent of single non-HDL-C level.

5.
Cardiol Res Pract ; 2022: 3002391, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35784946

RESUMEN

The optimal catheter ablation (CA) strategy for patients with persistent atrial fibrillation (PeAF) and heart failure (HF) remains uncertain. Between 2016 and 2020, 118 consecutive patients with PeAF and HF who underwent the CA procedure in two centers were retrospectively evaluated and divided into the pulmonary vein isolation (PVI)-only and PVI + additional ablation groups. Transthoracic echocardiography (TTE) was performed at baseline, one month, and 12 months after the CA procedure. The HF symptoms and left ventricular ejection fraction (LVEF) improvements were analyzed. Fifty-six patients underwent PVI only, and 62 patients received PVI with additional ablation. Compared with the baseline, a significant improvement in the LVEF and left atrial diameter postablation was observed in all patients. No significant HF improvement was detected in the PVI + additional ablation group than in the PVI-only group (74.2% vs. 71.4%, P = 0.736), but the procedure and ablation time were significantly longer (137.4 ± 7.5 vs. 123.1 ± 11.5 min, P = 0.001). There was no significant difference in the change in TTE parameters and the number of rehospitalizations. For patients with PeAF and HF, CA appears to improve left ventricular function. Additional ablation does not improve outcomes and has a significantly longer procedure time. Trial registration number is as follows: ChiCTR2100053745 (Chinese Clinical Trial Registry; https://www.chictr.org.cn/index.aspx).

6.
Int J Cardiol ; 335: 47-51, 2021 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-33845081

RESUMEN

INTRODUCTION: The efficacy and safety of his-purkinje system pacing (HPSP) upgrades in patients with pacing-induced cardiomyopathy (PICM) and atrial fibrillation (AF) are still unknown. METHODS AND RESULTS: Patients with PICM were continuously enrolled from January 2018 to March 2020. All patients were further divided into AF subgroup and sinus rhythm subgroup. Clinical data including echocardiographic examination parameters, electrocardiogram (ECG) measurements, and New York Heart Association (NYHA) classification, were assessed before and after the procedure. The HPSP upgrades, including his bundle pacing (HBP) and left bundle branch pacing (LBBP) were completed in 34 of 36 (94%) patients, Complications including electrode dislodged, perforation, infection or thrombosis were not observed in the perioperative period. During a mean of 11.52 ± 5.40 months of follow-up. The left ventricular ejection fraction (LVEF) increased significantly (33.76 ± 7.54 vs 40.41 ± 9.06, P < 0.001), and the QRS duration decreased (184.22 ± 23.76 ms vs 120.52 ± 16.67 ms, P < 0.001) after the upgrades. LVEDD reversed from 59.29 ± 7.74 mm to 53.91 ± 5.92 mm (P < 0.001), and the NYHA functional class also improved to 2.00 ± 0.76 from 2.55 ± 0.91 at the first follow-up (P < 0.001). The left atrium (LA) size also slightly decreased compared to the initial state (47.44 ± 7.14 mm VS 45.56 ± 7.78, P = 0.010). BNP significantly decreased from a median value of 458.06(256.35-755.10) to 172.31(92.69-552.14) (P = 0.004). The threshold did not increase significantly (1.18 ± 0.76 mv@0.4 ms vs 1.26 ± 0.91mv @ 0.4 ms, P = 0.581). These improvements in patients with AF were similar with those in patients without AF (P > 0.05). CONCLUSIONS: HPSP upgrades improved the heart performance and reversed the left ventricular remodeling in patients suffering from PICM with or without AF, and it should be a promising choice in these patients.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Humanos , Volumen Sistólico , Función Ventricular Izquierda
7.
Int J Bioprint ; 5(2): 168, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-32782982

RESUMEN

Additive manufacturing has been used in complex spinal surgical planning since the 1990s and is now increasingly utilized to produce surgical guides, templates, and more recently customized implants. Surgeons report beneficial impacts using additively manufactured biomodels as pre-operative planning aids as it generally provides a better representation of the patient's anatomy than on-screen viewing of computed tomography (CT) or magnetic resonance imaging (MRI). Furthermore, it has proven to be very beneficial in surgical training and in explaining complex deformity and surgical plans to patients/parents. This paper reviews the historical perspective, current use, and future directions in using additive manufacturing in complex spinal surgery cases. This review reflects the authors' opinion of where the field is moving in light of the current literature. Despite the reported benefits of additive manufacturing for surgical planning in recent years, it remains a high niche market. This review raises the question as to why the use of this technology has not progressed more rapidly despite the reported advantages - decreased operating time, decreased radiation exposure to patients intraoperatively, improved overall surgical outcomes, pre-operative implant selection, as well as being an excellent communication aid for all medical and surgical team members. Increasingly, the greatest benefits of additive manufacturing technology in spinal surgery are custom-designed drill guides, templates for pedicle screw placement, and customized patient-specific implants. In view of these applications, additive manufacturing technology could potentially revolutionize health care in the near future.

8.
Int J Bioprint ; 5(2): 232, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-32954041

RESUMEN

[This retracts the article on p. 168 in vol. 5, PMID: 32782982.].

9.
Life Sci ; 219: 74-81, 2019 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-30611784

RESUMEN

AIMS: Progressive cardiac conduction disease (PCCD) is a rare heart disease that usually shows familial inheritance. Potential genetic risk factors for PCCD have been mostly limited to genes that encode ion channels, cardiac transcription factors, T-box transcription factors, gap junction proteins, energy metabolism regulators and structural proteins. MAIN METHODS: Subjects in the present study came from a family who exhibited the autosomal dominant inheritance of PCCD. The primary proband had syncope and an electrocardiogram typical for PCCD, which started in the left bundle branch block, and passed to the atrioventricular block. The patient received a permanent pacemaker in 2013. Pathogenic mutations in the proband's family were identified using whole-exome sequencing and Sanger sequencing. KEY FINDINGS: The results for the family members were verified using Sanger sequencing, while the results for healthy unrelated individuals were verified using SNaPShot. All patients in the family shared two adjacent missense mutations in the preprodynorphin (PDYN) gene (c.581A > T, c.580G > C; p.D194L). SIGNIFICANCE: The PDYN double mutation c.581A > T and c.580G > C (p.D194L) may be linked to the onset of familial PCCD. The effects of these mutations on electrophysiology require further investigation.


Asunto(s)
Trastorno del Sistema de Conducción Cardíaco/genética , Dinorfinas/genética , Exoma/genética , Mutación Missense/genética , Precursores de Proteínas/genética , Adulto , Trastorno del Sistema de Conducción Cardíaco/fisiopatología , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Linaje , Reacción en Cadena de la Polimerasa , Análisis de Secuencia de ADN
10.
Chin Med J (Engl) ; 132(3): 285-293, 2019 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-30681494

RESUMEN

BACKGROUND: Pulmonary vein (PV) occlusion generally depends on repetitive contrast agent injection when cryoballoon ablation for atrial fibrillation (AF). The present study was to compare the effect of cryoballoon ablation for AF guided by transesophageal echocardiography (TEE) vs. contrast agent injection. METHODS: Eighty patients with paroxysmal AF (PAF) were enrolled in the study. About 40 patients underwent cryoballoon ablation without TEE (non-TEE group) and the other 40 underwent cryoballoon ablation with TEE for PV occlusion (TEE group). In the TEE group during the procedure, PVs were displayed in 3-dimensional images to guide the balloon to achieve PV occlusion. The patients were followed up at regularly scheduled visits every 2 months. RESULTS: No differences were identified between the groups in regard to the procedure time and cryoablation time for each PV. The fluoroscopy time (6.7 ±â€Š4.2 min vs. 17.9 ±â€Š5.9 min, P < 0.05) and the amount of contrast agent (3.0 ±â€Š5.1 mL vs.18.1 ±â€Š3.4 mL, P < 0.05) in the TEE group were both less than the non-TEE group. At a mean of 13.0 ±â€Š3.3 mon follow-up, success rates were similar between the TEE group and non-TEE group (77.5% vs. 80.0%, P = 0.88). CONCLUSIONS: Cryoballoon ablation with TEE for occlusion of the PV is both safe and effective. Less fluoroscopy time and a lower contrast agent load can be achieved with the help of TEE for PV occlusion during procedure.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Criocirugía/métodos , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Anciano , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Resultado del Tratamiento
11.
Nat Genet ; 43(4): 345-9, 2011 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-21378986

RESUMEN

Coronary artery disease (CAD) causes more than 700,000 deaths each year in China. Previous genome-wide association studies (GWAS) in populations of European ancestry identified several genetic loci for CAD, but no such study has yet been reported in the Chinese population. Here we report a three-stage GWAS in the Chinese Han population. We identified a new association between rs6903956 in a putative gene denoted as C6orf105 on chromosome 6p24.1 and CAD (P = 5.00 × 10⁻³, stage 2 validation; P = 3.00 × 10⁻³, P = 1.19 × 10⁻8 and P = 4.00 × 10⁻³ in three independent stage 3 replication populations; P = 4.87 × 10⁻¹², odds ratio = 1.51 in the combined population). The minor risk allele A of rs6903956 is associated with decreased C6orf105 mRNA expression. We report the first GWAS for CAD in the Chinese Han population and identify a SNP, rs6903956, in C6orf105 associated with susceptibility to CAD in this population.


Asunto(s)
Pueblo Asiatico/genética , Enfermedad de la Arteria Coronaria/genética , Alelos , Estudios de Casos y Controles , China , Cromosomas Humanos Par 6/genética , Femenino , Predisposición Genética a la Enfermedad , Estudio de Asociación del Genoma Completo , Humanos , Desequilibrio de Ligamiento , Masculino , Polimorfismo de Nucleótido Simple , ARN Mensajero/genética , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA