Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Pediatr Radiol ; 54(10): 1704-1712, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39060414

RESUMEN

BACKGROUND: Bone age assessment assists physicians in evaluating the growth and development of children. However, deep learning methods for bone age estimation do not currently incorporate differential features obtained through comparisons with other bone atlases. OBJECTIVE: To propose a more accurate method, Delta-Age-Sex-AdaIn (DASA-net), for bone age assessment, this paper combines age and sex distribution through adaptive instance normalization (AdaIN) and style transfer, simulating the process of visually comparing hand images with a standard bone atlas to determine bone age. MATERIALS AND METHODS: The proposed Delta-Age-Sex-AdaIn (DASA-net) consists of four modules: BoneEncoder, Binary code distribution, Delta-Age-Sex-AdaIn, and AgeDecoder. It is compared with state-of-the-art methods on both a public Radiological Society of North America (RSNA) pediatric bone age prediction dataset (14,236 hand radiographs, ranging from 1 to 228 months) and a private bone age prediction dataset from Zigong Fourth People's Hospital (474 hand radiographs, ranging from 12 to 218 months, 268 male). Ablation experiments were designed to demonstrate the necessity of incorporating age distribution and sex distribution. RESULTS: The DASA-net model achieved a lower mean absolute deviation (MAD) of 3.52 months on the RSNA dataset, outperforming other methods such as BoneXpert, Deeplasia, BoNet, and other deep learning based methods. On the private dataset, the DASA-net model obtained a MAD of 3.82 months, which is also superior to other methods. CONCLUSION: The proposed DASA-net model aided the model's learning of the distinctive characteristics of hand bones of various ages and both sexes by integrating age and sex distribution into style transfer.


Asunto(s)
Determinación de la Edad por el Esqueleto , Humanos , Determinación de la Edad por el Esqueleto/métodos , Masculino , Femenino , Niño , Preescolar , Lactante , Adolescente , Aprendizaje Profundo
2.
BMC Musculoskelet Disord ; 23(1): 330, 2022 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-35395846

RESUMEN

BACKGROUND: External fixation, which can preserve the biomechanical microenvironment of fracture healing, plays an important role in managing the high-energy fractures with poor surrounding soft tissues. The purpose of this study was to determine the differences of clinical outcomes, if any, between hexapod external fixator and monolateral external fixator in the definitive treatment of high-energy tibial diaphyseal fractures. METHODS: A total of 53 patients with high-energy tibial diaphyseal fractures and definitively treated by the hexapod external fixator (HEF) or monolateral external fixator (MEF) were retrospectively collected and analyzed, from March 2015 to June 2019. There were 31 patients in the HEF treatment, and the other 22 patients were managed by the MEF. The demographic data, surgical duration, external fixation time, final radiological results, complications, and clinical outcomes were documented and analyzed. Difficulties that occurred during the treatment were classified according to Paley. The clinical outcomes were evaluated by the Association for the Study and Application of the Method of Ilizarov criteria (ASAMI) at the last clinical visit. RESULTS: The mean surgical duration in the HEF group (62.4 ± 8.3 min) was shorter than that in the MEF group (91.4 ± 6.9 min) (P < 0.05). All patients acquired complete bone union finally. Patients in the HEF group (24.2 ± 3.1 weeks) underwent a shorter average external fixation time than that in the MEF group (26.3 ± 3.8 weeks) (P < 0.05). Satisfactory alignment was achieved in all patients without the need for remanipulation. The residual sagittal plane deformities in the HEF group were all less than that in the MEF group (P < 0.05). The complication rate was 35.5% in the HEF group, while 45.5% in the MEF group. There was no statistically significant difference between the two groups in ASAMI scores (P > 0.05). CONCLUSION: There is no statistically significant difference in finally clinical outcomes between hexapod external fixator and monolateral external fixator in the definitive treatment of high-energy tibial diaphyseal fractures. The hexapod external fixation treatment is a superior effective method, including advantages of stable fixation, less surgical duration, postoperatively satisfactory fracture reduction, and fewer complications.


Asunto(s)
Fijadores Externos , Fracturas de la Tibia , Diáfisis/diagnóstico por imagen , Diáfisis/cirugía , Fijación de Fractura/efectos adversos , Fijación de Fractura/métodos , Curación de Fractura , Humanos , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/etiología , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
3.
BMC Musculoskelet Disord ; 23(1): 224, 2022 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-35260138

RESUMEN

BACKGROUD: When the reduction of long bone shaft fracture fragments is performed by a hexapod external fixator, the collision and interference between bony ends often results in an incomplete reduction and a time-consuming procedure. The purpose of this study was to present and determine the clinical effectiveness of staged correction trajectory with hexapod external fixator in the reduction of a long bone shaft fracture. METHODS: A total of 57 patients with tibial shaft fractures treated by hexapod external fixator were retrospectively analyzed from June 2016 to February 2020. Thirty-one cases (Group I) underwent a conventional one-step reduction trajectory from June 2016 to July 2018. Starting in September 2018, the other twenty-six patients (Group II) underwent staged correction trajectory (three key points reduction trajectory of "distraction-derotation-reduction"). The demographic data, residual deformities before and after correction, number of repeated X-rays after the first postoperative X-ray, duration of deformity correction process, and external fixation time were analyzed. Johner-Wruhs criteria were used to evaluate the final clinical outcomes. RESULTS: All the 57 patients achieved satisfactory fracture reduction and bone union. There were no significant differences between the two groups in demographic data, residual deformities before and after correction, external fixation time, and final clinical outcomes (p > 0.05). The average number of repeated X-rays after the first postoperative X-ray and mean duration of deformity correction process in Group II (1.3 times, 2.9 days) were all less than those in Group I (2.3 times, 5.1 days) (p < 0.05). CONCLUSION: Compared with the conventional one-step reduction trajectory, there is no differences in final clinical outcomes, but the staged correction trajectory provides less repeated X-rays and shorter reduction process duration.


Asunto(s)
Fijadores Externos , Fracturas de la Tibia , Diáfisis , Fijación de Fractura/métodos , Humanos , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
4.
BMC Musculoskelet Disord ; 23(1): 155, 2022 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-35172802

RESUMEN

BACKGROUND: The Taylor Spatial Frame (TSF) has been widely used for tibial fracture. However, traditional radiographic measurement method is complicated and the reduction accuracy is affected by various factors. The purpose of this study was to propose a new marker- three dimensional (3D) measurement method and determine the differences of reduction outcomes, if any, between marker-3D measurement method and traditional radiographic measurement in the TSF treatment. METHODS: Forty-one patients with tibial fracture treated by TSF in our institution were retrospectively analyzed from January 2016 to June 2019, including 21 patients in the marker-3D measurement group (experimental group) and 20 patients in the traditional radiographic measurement group (control group). In the experimental group, 3D reconstruction with 6 markers installed on the TSF was performed to determine the electronic prescription. In the control group, the anteroposterior (AP) and lateral radiographs were performed for the traditional parameter measurements. The effectiveness was evaluated by the residual displacement deformity (RDD) and residual angle deformity (RAD) in the coronal and sagittal plane, according to the AP and lateral X-rays after reduction. RESULTS: All patients achieved functional reduction. The residual RDD in AP view was 0.5 (0, 1.72) mm in experimental group and 1.74 (0.43, 3.67) mm in control group. The residual RAD in AP view was 0 (0, 1.25) ° in experimental group and 1.25 (0.62, 1.95) °in control group. As for the lateral view, the RDD was 0 (0, 1.22) mm in experimental group and 2.02 (0, 3.74) mm in control group, the RAD was 0 (0, 0) ° in experimental group and 1.42 (0, 1.93) ° in control group. Significant differences in all above comparisons were observed between the two groups (AP view RDD: P = 0.024, RAD: P = 0.020; Lateral view RDD: P = 0.016, RAD: P = 0.004). CONCLUSIONS: The present study introduced a marker-3D measurement method to complement the current TSF treatment. This method avoids the manual measurement error and improves the accuracy of fracture reduction, providing potential advantages of bone healing and function rehabilitation.


Asunto(s)
Fracturas de la Tibia , Fijadores Externos , Fijación de Fractura , Humanos , Radiografía , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía
5.
BMC Musculoskelet Disord ; 22(1): 803, 2021 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-34537029

RESUMEN

BACKGROUND: The purpose of this study was to determine the differences in clinical outcomes, if any, between intraoperative acute correction and postoperative gradual correction for tibial shaft fractures with multiplanar posttraumatic deformities using the hexapod external fixator. METHODS: We retrospectively analyzed 58 consecutive patients with tibial shaft fractures treated by the hexapod external fixator at our institution from January 2015 to April 2019. Twenty-three patients (Group I) underwent intraoperative acute correction, from January 2015 to October 2016. Starting in November 2016, the other 35 patients (Group II) all underwent postoperative gradual correction. The demographic data, operation duration, original residual deformities before correction, residual deformities after correction, and external fixation time were collected and analyzed. The clinical outcomes were evaluated by the Johner-Wruhs criteria at the last clinical visit. RESULTS: All patients achieved complete bone union with a mean time of 28.7 ± 4.6 weeks (range 21 to 37 weeks) in Group I and 27.9 ± 4.8 weeks (range 19 to 38 weeks) in Group II (P > 0.05). The operation duration in Group I (88.9 ± 7.7 min) was longer than that in Group II (61.9 ± 8.4 min), and there was a statistically significant difference (P < 0.05). There were no statistically significant differences between the two groups in original residual deformities before correction and residual deformities after correction (P > 0.05). The rate of postoperative complication was similar between the two groups. There was no statistical significance in demographic data and clinical outcomes between the two groups (P > 0.05). CONCLUSIONS: There is no difference in clinical outcomes between intraoperative acute correction and postoperative gradual correction for tibial shaft fractures with multiplanar posttraumatic deformities using the hexapod external fixator. Postoperative gradual correction may shorten the duration in the operation room and decrease the potential intraoperative risk.


Asunto(s)
Fijadores Externos , Fracturas de la Tibia , Humanos , Estudios Retrospectivos , Tibia , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
6.
BMC Musculoskelet Disord ; 22(1): 221, 2021 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-33627096

RESUMEN

BACKGROUND: The hexapod external fixator (HEF), such as the Taylor spatial frame (TSF), offering the ability of multidirectional deformities correction without changing the structure, whereas there are so many parameters for surgeons to measure and subjective errors will occur inevitably. The purpose of this study was to evaluate the effectiveness of a new method based on computer-assisted three-dimensional (3D) reconstruction and hexapod external fixator for long bone fracture reduction and deformity correction without calculating the parameters needed by the traditional usage. METHODS: This retrospective study consists of 25 patients with high-energy tibial diaphyseal fractures treated by the HEF at our institution from January 2016 to June 2018, including 22 males and 3 females with a mean age of 42 years (range 14-63 years). Hexapod external fixator treatments were conducted to manage the multiplanar posttraumatic deformities with/without poor soft-tissue that were not suitable for internal fixation. Computer-assisted 3D reconstruction and trajectory planning of the reduction by Mimics were applied to perform virtual fracture reduction and deformity correction. The electronic prescription derived from the length changes of the six struts were calculated by SolidWorks. Fracture reduction was conducted by adjusting the lengths of the six struts according to the electronic prescription. Effectiveness was evaluated by the standard anteroposterior (AP) and lateral X-rays after reduction. RESULTS: All patients acquired excellent functional reduction and achieved bone union in our study. After correction, the mean translation (1.0 ± 1.1 mm) and angulation (0.8 ± 1.2°) on the coronal plane, mean translation (0.8 ± 1.0 mm) and angulation (0.3 ± 0.8°) on the sagittal plane were all less than those (6.1 ± 4.9 mm, 5.2 ± 3.2°, 4.2 ± 3.5 mm, 4.0 ± 2.5°) before correction (P < 0.05). CONCLUSIONS: The computer-assisted three-dimensional reconstruction and hexapod external fixator-based method allows surgeons to conduct long bone fracture reduction and deformity correction without calculating the parameters needed by the traditional usage. This method is suggested to apply in those unusually complex cases with extensive soft tissue damage and where internal fixation is impossible or inadvisable.


Asunto(s)
Fijadores Externos , Fracturas de la Tibia , Adolescente , Adulto , Femenino , Fijación de Fractura , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tibia , Adulto Joven
7.
Int Orthop ; 45(12): 3015-3023, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34164731

RESUMEN

PURPOSE: As the monolateral external fixator is increasingly used in trauma-control and definitive management for high-energy long bone fractures, timing the fixator removal remains a challenge for surgeons. The purpose of this study was to determine the feasibility and effectiveness of the bony callus stiffness indirectly evaluated by the axial load-share ratio in vivo as a guide to removing a monolateral external fixator safely. METHODS: A total of 131 patients with tibial shaft fractures treated by the monolateral external fixator in our institution were collected from January 2013 to July 2019. In group I, the fixators were removed based on the clinical and radiological assessment only by the treating surgeon. As for group II, the axial load-share (LS) ratio test was accomplished by another medical team without the knowledge of the clinical results. The external fixator was removed when the mechanical test outcome (LS ratio < 10%) was consistent with the conclusion drawn from the clinical and radiological assessment (bone union achieved) by the treating surgeon. RESULTS: There was no statistical significance in demographic data between the two groups (P > 0.05). In group I, four patients suffered refracture (the refracture rate was 7.7%) after fixator removal and were successfully treated by an intramedullary nail. In group II, 71 patients underwent fixator removal after the first mechanical test, and another eight patients terminated the external fixation after the second test. None of the 79 patients in group II suffered refracture (the refracture rate was 0%). There was statistical significance in the refracture rate between the two groups (P < 0.05). CONCLUSION: The bony callus stiffness indirectly evaluated by the axial load-share ratio in vivo using the additional circular frame components is an effectively quantitative indicator to complement the clinical assessment of fracture healing in a monolateral external fixation treatment. Removal of the monolateral external fixator is safe when the axial load-share ratio dropped below 10%.


Asunto(s)
Callo Óseo , Fracturas de la Tibia , Callo Óseo/diagnóstico por imagen , Fijadores Externos , Fijación de Fractura/efectos adversos , Curación de Fractura , Humanos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
8.
Heliyon ; 10(6): e27630, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38515694

RESUMEN

Background: Immunogenic cell death (ICD) is related to cancer prognosis, which has a synergic effect in combination with chemotherapy or immunotherapy. Yet, the relationship between ICD and osteosarcoma remained unclear. Materials and methods: Three osteosarcoma datasets including therapeutically applicable research to generate effective treatments (TARGET), GSE126209 and GSE21257 datasets were included. A protein-protein interaction network was constructed based on ICD-related genes. We performed unsupervised consensus clustering to classify molecular subtypes (clusters). Survival analysis, Estimation of stromal and immune cells in malignant tumour tissues using expression data (ESTIMATE), Cell-type identification by estimating relative subsets of RNA transcripts (CIBERSORT), and differential analysis were employed to characterize the molecular differences between different clusters. Univariate Cox regression analysis was conducted to confirm prognostic genes. Quantitative reverse transcription polymerase chain reaction (qRT-PCR) was used to demonstrate the aberrant expression of ICD-correlated signature genes in osteosarcoma. A series of cellular experiments, including cell counting kit-8 (CCK-8), transwell, and flow cytometry, were used to demonstrate the regulatory role of key genes in the ICD model on the malignant phenotype of osteosarcoma. Results: Three clusters (cluster1, 2, 3) were constructed and they showed distinct overall survival and immune infiltration. ICD-related genes were highly expressed in cluster1. Moreover, Cluster1 had the best prognosis, high immune score and high expression of human leukocyte antigen (HLA)-related genes. TLR4, LY96, IFNGR1, CD4, and CASP1 were identified as prognostic genes for establishing an ICD-related risk signature. According to the risk signature, two risk groups (high and low risks) showing differential prognosis and response to immunotherapy. The low risks group had a better prognosis but was not sensitive to immunotherapy. Molecular assays verified that prognostic genes were abnormally under-expressed in osteosarcoma. Cellular assays demonstrated that LY96, the most significantly down-regulated gene in osteosarcoma, inhibited the migration, invasion, and proliferation phenotypes of osteosarcoma cells and prolonged the cell cycle. Analysis of oxidative stress related pathway enrichment in tumor microenvironment was conducted by single-sample gene set enrichment analysis (ssGSEA). Conclusions: This study demonstrated the prognostic significance of ICD-correlated genes in osteosarcoma patients. The five-gene risk signature facilitate prognostic evaluation and prediction of osteosarcoma patients' response to immunotherapy. The risk signature also offered a possibility for the exploit of novel ICD-related treatment.

9.
Materials (Basel) ; 17(9)2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38730927

RESUMEN

A new approach is proposed that identifies three different zones of the Si-rich network structure (the cellular structure) in laser powder bed fused (LPBF) AlSi10Mg alloy, based on the variation in morphology, grain growth transition, and melt pool solidification conditions. The three identified zones are denoted in the present work as the liquid solidification zone (LSZ), the mushy solidification zone (MSZ), and the heat affected zone (HAZ). The LSZ is the result of liquid-solid transformation, showing small planar growth at the boundary and large cellular growth in the center, while the MSZ is related to a semisolid reaction, and the HAZ arises from a short-time aging process. The boundary between the LSZ and MSZ is identified by the change of grain growth direction and the Si-rich network advancing direction. The boundary between MSZ and HAZ is identified by the start of the breakdown of the Si-rich network. In addition, it is found that the fracture is generated in and propagates along the HAZ during tensile tests.

10.
iScience ; 26(4): 106437, 2023 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-37034990

RESUMEN

Aqueous zinc-ion batteries (ZIBs) have received numerous attention because of their inherent safety and low cost. However, ZIBs are highly sensitive to temperature; the realization of full-temperature ZIBs is of great importance. In this study, an agar-based composite hydrogel polymer electrolyte (AG-HGPE) with the blend of agar and polyacrylamide (PAM) was prepared. It has a non-porous homogeneous structure, and shows various merits, e.g., strong liquid absorption rate, good mechanical properties, and large Zn2+ transference number. The corresponding Zn-symmetric cells possess reversible zinc stripping/plating phenomenon up to 500 h at a current density of 1 mA cm-2 and an areal capacity of 1 mAh cm-2. The Zn/AG-HGPE/V2O5 cells exhibit good rate performance and stable cyclic behaviors at -25°C, 25°C and 50°C, as well as excellent adaptability to the changes of ambient temperature. The research paves a new route for developing green energy storage devices running in wide temperature range.

11.
Injury ; 52(11): 3478-3482, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33487408

RESUMEN

BACKGROUND: Postoperative malalignment in fractures treated by monolateral external fixation is not uncommon in clinical practice. Accurate reduction without excessive tissue disruption caused by surgical intervention and sequentially manage the fractures using monolateral external fixation for definitive treatment is still a challenge for surgeons. The purpose of our study was to evaluate the feasibility and effectiveness of the temporary application of the hexapod external fixator (HEF) for the postoperative malalignment correction in tibial diaphyseal fractures treated by monolateral external fixation. METHODS: We carried out a retrospective analysis of 23 trauma patients with tibial diaphyseal fracture treated by the monolateral external fixation at our institution from January 2016 to May 2019. There were 21 males and 2 females with a mean age of 38 years (range 18-60 years). The hexapod external fixator was temporarily applied due to postoperative malalignment within two weeks and who unwilling to undergo a secondary surgical intervention. For patients with postoperative malalignment requiring correction, the HEF components were installed on the original existing half pins of the monolateral external fixator after removing the connecting rod. The standard anteroposterior and lateral X-rays of the injured limb combined with the temporary HEF were conducted to measure the hexapod external fixator parameters. Any residual deformities were corrected by gradual struts adjustment with the aid of computer-based software. When satisfactory alignment was achieved, the HEF was removed, and the monolateral external fixator was sequentially used as the definitive structure. RESULTS: All patients acquired functional reduction, which was evaluated by radiographs. The mean correction time was 4 days (range 2 to 8 days). The mean coronal plane translation (1.3±1.0 mm), coronal plane angulation (0.9±0.7°), sagittal plane translation (1.4±1.1 mm), and sagittal plane angulation (0.7±0.7°) after correction were all less than those (7.0±4.9 mm, 4.7±2.3°, 5.6±3.6 mm, 3.2±2.5°) before correction. CONCLUSIONS: The temporary application of the hexapod external fixator is an alternative and feasible method for the postoperative malalignment correction in tibial diaphyseal fractures treated by monolateral external fixation.


Asunto(s)
Fijadores Externos , Fracturas de la Tibia , Adolescente , Adulto , Diáfisis/diagnóstico por imagen , Diáfisis/cirugía , Femenino , Fijación de Fractura , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Resultado del Tratamiento , Adulto Joven
12.
Polymers (Basel) ; 12(7)2020 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-32679867

RESUMEN

With the raw materials of poly(vinylidene-co-hexafluoropropylene) (P(VDF-HFP)) and polyamide 6 (PA6, nylon 6), a sandwich-structured composite membrane, PA6/P(VDF-HFP)/PA6, is fabricated via sequential layer-by-layer electrospinning. The nylon-based composite exhibits high absorption to organic liquid electrolyte (270 wt%) owing to its high porosity (90.35%), good mechanical property (17.11 MPa), and outstanding shut-down behavior from approximately 145 to 230 °C. Moreover, the dimensional shrink of a wet PA6 porous membrane immersed into liquid electrolyte is cured due to the existence of the P(VDF-HFP) middle layer. After swelling by the LiPF6-based organic liquid electrolyte, the obtained PA6/P(VDF-HFP)/PA6-based gel polymer electrolytes (GPE) shows high ionic conductivity at room temperature (4.2 mS cm-1), a wide electrochemical stable window (4.8 V), and low activation energy for Li+ ion conduction (4.68 kJ mol-1). Benefiting from the precise porosity structure made of the interlaced electrospinning nanofibers and the superior physicochemical properties of the nylon-based composite GPE, the reversible Li+ ion dissolution/deposition behaviors between the GPE and Li anode are successfully realized with the Li/Li symmetrical cells (current density: 1.0 mA cm-2; areal capacity: 1.0 mAh cm-2) proceeding over 400 h at a polarization voltage of no more than 70 mV. Furthermore, the nylon-based composite GPE in assembled Li/LiFePO4 cells displays good electrochemical stability, high discharge capacity, good cycle durability, and high rate capability. This research provides a new strategy to fabricate gel polymer electrolytes via the electrospinning technique for rechargeable lithium batteries with good electrochemical performance, high security, and low cost.

13.
Oncol Lett ; 17(6): 4865-4870, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31186694

RESUMEN

The expression levels of p16 and nm23-H1 genes in soft tissue sarcoma (STS) were evaluated to investigate correlation of the expression levels with the incidence and prognosis of STS. Tumor tissues and para-carcinoma normal tissues were collected from 64 STS patients. The messenger ribonucleic acid (mRNA) expression levels of p16 and nm23-H1 in the tissues were detected via reverse transcription-quantitative polymerase chain reaction (RT-qPCR), and the protein expression levels of p16 and nm23-H1 in tissues were detected using immunohistochemistry. Spearman's correlation analysis was used for the correlation between expression levels of p16 and nm23-H1 in STS tissues and the correlation between p16 and nm23-H1 mRNA and protein expression. Moreover, the correlation of p16 and nm23-H1 expression levels in tumor tissues with pathological parameters and prognosis of STS patients were analyzed combined with clinical data. Results of RT-qPCR showed that mRNA expression levels of p16 and nm23-H1 in tumor tissues of STS patients were significantly lower than those in para-carcinoma normal tissues (P<0.01). Results of immunohistochemistry showed that the positive expression rates of p16 and nm23-H1 in tumor tissues of STS patients (43.75 and 39.06% respectively) were significantly lower than those in para-carcinoma normal tissues (85.93 and 89.06% respectively). The expression of p16 and nm23-H1 mRNA was positively correlated with protein expression levels. There was a positive correlation between the expression levels of p16 and nm23-H1 in tumor tissues of STS patients. The negative expression of p16 in tumor tissues of STS patients correlated with tumor size, tumor metastasis and clinical staging, and the negative expression of nm23-H1 correlated with tumor metastasis and clinical staging. The overall 5-year survival rate of patients was 54.68%, and the prognosis of patients with positive expression levels of p16 and nm23-H1 was better. Univariate survival analyses revealed that p16 and nm23-H1 were influencing factors of the overall survival rate of STS patients. p16 and nm23-H1 expression in STS is low, and their expression levels are closely related to the pathological parameters and prognosis of STS patients, so they can serve as reference indexes for prognosis estimation of STS.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA