Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Mikrochim Acta ; 191(7): 407, 2024 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-38898338

RESUMEN

A smartphone-based electrochemical aptasensing platform was developed for the point-of-care testing (POCT) of carcinoembryonic antigen (CEA) based on the ferrocene (Fc) and PdPt@PCN-224 dual-signal labeled strategy. The prepared PdPt@PCN-224 nanocomposite showed a strong catalytic property for the reduction of H2O2. Phosphate group-labeled aptamer could capture PdPt@PCN-224 by Zr-O-P bonds to form PdPt@PCN-224-P-Apt. Therefore, a dual signal labeled probe was formed by the hybridization between Fc-DNA and PdPt@PCN-224-P-Apt. The presence of CEA forced PdPt@PCN-224-P-Apt to leave the electrode surface due to the specific affinity, leading to the decrease of the reduction current of H2O2. At the same time, the Fc-DNA strand changed to hairpin structure, which made Fc closer to the electrode and resulted in the increase of the oxidation current of Fc. Thus, CEA can be accurately determined through both signals: the decrease of H2O2 reduction current and the increase of Fc oxidation current, which could avoid the false positive signal. Under the optimal conditions, the prepared aptasensor exhibited a wide linear range from 1 pg·mL-1 to 100 ng·mL-1 and low detection limits of 0.98 pg·mL-1 and 0.27 pg·mL-1 with Fc and PdPt@PCN-224 as signal labels, respectively. The aptasensor developed in this study has successfully demonstrated its capability to detect CEA in real human serum samples. These findings suggest that the proposed sensing platform will hold great potential for clinical tumor diagnosis and monitoring.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Antígeno Carcinoembrionario , Técnicas Electroquímicas , Compuestos Ferrosos , Peróxido de Hidrógeno , Límite de Detección , Paladio , Pruebas en el Punto de Atención , Teléfono Inteligente , Antígeno Carcinoembrionario/sangre , Antígeno Carcinoembrionario/análisis , Aptámeros de Nucleótidos/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Humanos , Técnicas Biosensibles/métodos , Peróxido de Hidrógeno/química , Paladio/química , Compuestos Ferrosos/química , Metalocenos/química , Platino (Metal)/química
2.
Analyst ; 148(17): 4037-4043, 2023 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-37522239

RESUMEN

As a prognostic biomarker for breast cancer, human epidermal growth factor receptor 2 (HER-2) is of crucial diagnostic value. Here, a label-free electrochemical aptasensor was established for the ultrasensitive detection of HER-2 using a modified electrode of Bi-Sb alloy materials (Bi-Sb AMs). The performance of the aptasensor was enhanced greatly due to the introduction of Bi-Sb alloy materials (Bi-Sb AMs) with high conductivity. Furthermore, by integrating the aptasensor with the Sensit Smart U-disk electrochemical analyzer, the point-of-care testing (POCT) for HER-2 was realized. Under the optimal experimental parameters, the POCT analyzer showed a wide linear response from 0.01 pg mL-1 to 100 ng mL-1, with a low detection limit (LOD) of 5.96 fg mL-1 for the detection of HER-2. The presented POCT analyzer exhibited good specificity, stability, and reproducibility. Benefiting from the simple operation and rapid testing, the developed analyzer will have potential application in the prognostic diagnosis and treatment of breast cancer.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Humanos , Técnicas Electroquímicas , Aleaciones , Reproducibilidad de los Resultados , Límite de Detección , Oro
3.
Lab Chip ; 24(2): 367-374, 2024 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-38126214

RESUMEN

Carcinoembryonic antigen (CEA) is a biomarker of high expression in cancer cells. Highly sensitive and selective detection of CEA holds significant clinical value in the diagnosis, monitoring and efficacy evaluation of malignant tumors. In this work, a smartphone-based electrochemical point-of-care testing (POCT) platform for the detection of CEA was developed based on a Zr6MOF signal amplification strategy. Ferrocene labeled DNA strands (Fc-DNA) were immobilized on Zr6MOFs to form a Fc-DNA/Zr6MOF signal probe. Double-stranded DNA (dsDNA) formed by complementary DNA (cDNA) and CEA aptamer was assembled on a screen-printed electrode via an Au-S bond. When CEA was added, the aptamer specifically bound with CEA, resulting in the exposure of cDNA. Then, Fc-DNA/Zr6MOF signal probes were introduced on the electrode surface through hybridization between Fc-DNA and cDNA. The detection of CEA was realized by measuring the electrochemical response of Fc. The POCT device was made by connecting a modified electrode with a smartphone through a Sensit Smart USB flash disk. Due to the signal amplification of Zr6MOFs, this POCT platform exhibited high sensitivity, wide linear range, and low detection limit for CEA detection. The developed POCT platform has been used for the detection of CEA in actual human serum samples with satisfactory results.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Humanos , Antígeno Carcinoembrionario , ADN Complementario , Teléfono Inteligente , ADN/química , Aptámeros de Nucleótidos/química , Técnicas Electroquímicas , Límite de Detección , Oro/química
4.
Yao Xue Xue Bao ; 38(4): 279-82, 2003 Apr.
Artículo en Zh | MEDLINE | ID: mdl-12889128

RESUMEN

AIM: To develop a sensitive and specific HPLC method for determination of trigonelline in rabbit plasma, and study the pharmacokinetics in rabbit. METHODS: After ig of fenugreek extract and i.v. of trigonelline in rabbit, the biological samples could be well purified after precipitation of protein with methanol and acetonitrile. Asahipak NH2P-50 column was used, the mobile phase consisted of acetonitrile-water (90:10) at a flow-rate of 1.2 mL.min-1, and detection wavelength was set at UV 265 nm. The column temperature is 30 degrees C. RESULTS: The calibration curve was linear in the range from 0.98 mg.L-1 to 31.28 mg.L-1, with r = 0.9986, the detection limit of this method was 50 micrograms.L-1. The concentration-time curves of trigonelline in rabbits after ig and i.v. administration were shown to fit one-compartment and two-compartment open model, respectively. The main parameters after ig of fenugreek extract were as follow: T1/2(Ka) was 0.9 h, T1/2(Ke) was 2.2 h, V was 0.64 L.kg-1, AUC was 1.93 mg.min.L-1. The main parameters after i.v. of trigonelline were as follows: T1/2 alpha was 10.8 min, T1/2 beta was 44.0 min, K21 was 0.044 min-1, K10 was 0.026 min-1, K12 was 0.017 min-1, AUC was 931.0 mg.min.L-1. CONCLUSION: Trigonelline showed a middle rate of absorption and fast rate of elimination in rabbit. Meanwhile, the method is simple, accurate, with a good reproducibility, and it provide a basic method for the investigation of trigonelline and fenugreek pharmacokinetics.


Asunto(s)
Alcaloides/farmacocinética , Medicamentos Herbarios Chinos/farmacocinética , Trigonella/química , Alcaloides/sangre , Alcaloides/aislamiento & purificación , Animales , Antineoplásicos Fitogénicos/sangre , Antineoplásicos Fitogénicos/aislamiento & purificación , Antineoplásicos Fitogénicos/farmacocinética , Área Bajo la Curva , Cromatografía Líquida de Alta Presión/métodos , Medicamentos Herbarios Chinos/aislamiento & purificación , Femenino , Masculino , Plantas Medicinales/química , Conejos , Semillas/química
5.
Zhongguo Zhong Yao Za Zhi ; 27(3): 194-6, 2002 Mar.
Artículo en Zh | MEDLINE | ID: mdl-12774399

RESUMEN

OBJECTIVE: A HPLC method is established to determine the content of trigonelline in Trigonella foenum-graecum. METHOD: The medicinal material was extracted by petholeum ether-ethanol. Asahipak NH2P-50 column was used, mobilephase consisted of acetonitrile-water(75:25) and detection wavelength was set at UV 265 nm. RESULT: The standard curve was linear in the range of 3.68-73.60 micrograms.mL-1 with the correlation coefficient of 0.9999. The average recovery rate and RSD were 97.4% and 1.83% (n = 6) respectively. CONCLUSION: It provides scientific indexes for quality control of T. foenum-graecum.


Asunto(s)
Alcaloides/análisis , Plantas Medicinales/química , Trigonella/química , Cromatografía Líquida de Alta Presión , Control de Calidad , Semillas/química
6.
Biol Pharm Bull ; 26(9): 1289-94, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12951473

RESUMEN

A reliable enzyme immunoassay (EIA) method was developed for quantitative determination of aconitine with high sensitivity and specificity. The bovine serum albumin (BSA)- and beta-galactosidase (beta-Gal) conjugates as immunogens and enzyme-labeled antigens were prepared by coupling of their proteins with succinic acid (short chain length; n=2, where n represents the number of methylene units) and hexadecanedioic acid (long chain length; n=14) hemiesters of benzoylaconine through the respective N-hydroxysuccinimide esters as intermediates. Two types of the BSA-conjugates with short and long chains were repeatedly injected into rabbits to obtain anti-aconitine antisera (As1 and As2, respectively). All combinations of beta-Gal-labeled antigens LAg1 (n=2) and LAg2 (n=14) with antisera As1 (n=2) and As2 (n=14) showed high sensitivity to aconitine in a range of 0.1-1.0 ng. Although the combination of LAg2 (n=14) with antiserum As1 (n=2) showed high specificity to aconitine, the combination of LAg2 (n=14) and As2 (n=14) was highly specific to both aconitine and mesaconitine. When aconitine was intravenously administered to rats, the aconitine concentration in their plasma remarkably decreased within the first 60 min, and then gradually declined, suggesting a two-compartment pharmacokinetic model in (V(c) 0.41+/-0.09 l/kg, V(dss) 1.7+/-0.4 l/kg, CL(tot) 10+/-2 ml/min x kg, AUC(0-4800) 2055+/-294.3 ng x min/ml). Following oral administration of aconitine to rats at two doses of 0.1 and 1.0 mg/kg b.w., the maximum plasma concentrations (C(max)) were 0.73+/-0.08 and 3.3+/-0.6 ng/ml at times of 45+/-9 and 150+/-52 min, respectively, and the AUC(0-1440) values were 130+/-4 and 1600+/-270 ng x min/ml. The bioavailability (F) of aconitine was determined to be 0.013, where only 1.3% of the aconitine administered orally was absorbed into the body fluid.


Asunto(s)
Aconitina/análisis , Aconitina/sangre , Adyuvantes Inmunológicos/análisis , Adyuvantes Inmunológicos/sangre , Aconitina/farmacocinética , Adyuvantes Inmunológicos/farmacocinética , Administración Oral , Animales , Femenino , Haptenos/química , Técnicas para Inmunoenzimas , Indicadores y Reactivos , Inyecciones Intravenosas , Conejos , Ratas , Albúmina Sérica Bovina/química , Espectrofotometría Infrarroja , Espectrofotometría Ultravioleta , beta-Galactosidasa/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA