Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 227
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 59(3): 1045-1055, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37259904

RESUMEN

BACKGROUND: Lenticulostriate artery (LSA) obstruction is a potential cause of subcortical infarcts. However, MRI LSA evaluation at 3T is challenging. PURPOSE: To investigate middle cerebral artery (MCA) plaque characteristics and LSA morphology associated with subcortical infarctions in LSA territories using 7-T vessel wall MRI (VW-MRI) and time-of-flight MR angiography (TOF-MRA). STUDY TYPE: Prospective. POPULATION: Sixty patients with 80 MCA atherosclerotic plaques (37 culprit and 43 non-culprit). FIELD STRENGTH/SEQUENCE: 7-T with 3D TOF-MRA and T1-weighted 3D sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE) sequences. ASSESSMENT: Plaque distribution (superior, inferior, ventral, or dorsal walls), LSA origin involvement, LSA morphology (numbers of stems, branches, and length), and plaque characteristics (normalized wall index, maximal wall thickness, plaque length, remodeling index, intraplaque hemorrhage, and plaque surface morphology (regular or irregular)) were assessed. STATISTICAL TESTS: Least absolute shrinkage and selection operator regression, generalized estimating equations regression, receiver operating characteristic curve, independent t-test, Mann-Whitney U test, Chi-square test, Fisher's exact test, and intra-class coefficient. A P value <0.05 was considered statistically significant. RESULTS: Plaque irregular surface, superior wall plaque, longer plaque length, LSA origin involvement, fewer LSA stems, and shorter total and average lengths of LSAs were significantly associated with culprit plaques. Multivariable logistic analysis confirmed that LSA origin involvement (OR, 28.51; 95% CI, 6.34-181.02) and plaque irregular surface (OR, 8.32; 95% CI, 1.41-64.73) were independent predictors in differentiating culprit from non-culprit plaques. A combination of LSA origin involvement and plaque irregular surface (area under curve = 0.92; [95% CI, 0.86-0.98]) showed good performance in identifying culprit plaques, with sensitivity and specificity of 86.5% and 86.0%, respectively. DATA CONCLUSION: 7-T VW-MRI and TOF-MRA can demonstrate plaque involvement with LSA origins. MCA plaque characteristics derived from 7-T VW-MRI showed good diagnostic accuracy in determining the occurrence of subcortical infarctions. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 3.


Asunto(s)
Arteria Cerebral Media , Placa Aterosclerótica , Humanos , Estudios Prospectivos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Infarto Cerebral , Angiografía por Resonancia Magnética
2.
Eur Radiol ; 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39030372

RESUMEN

OBJECTIVES: To investigate the efficacy of statins on symptomatic intracranial atherosclerotic plaques using high-resolution 3.0 T MR vessel wall imaging (HR-MRI). METHODS: Patients with symptomatic intracranial atherosclerotic plaques (cerebral ischemic events within the last three months) confirmed by HR-MRI from July 2017 to August 2022 were retrospectively included in this study. The enrolled patients started statin therapy at baseline. All the patients underwent the follow-up HR-MRI examination after statin therapy for at least 3 months. A paired sample t-test and Wilcoxon rank sum test were used to evaluate the changes in plaque characteristics after statin therapy. Multivariate linear regression was further used to investigate the clinical factors associated with statin efficacy. RESULTS: A total of 48 patients (37 males; overall mean age = 60.2 ± 11.7 years) were included in this study. The follow-up time was 7.0 (5.6-12.0) months. In patients treated with statins for > 6 months (n = 31), plaque length, wall thickness, plaque burden, luminal stenosis and plaque enhancement were significantly reduced. Similar results were found in patients with good lipid control (n = 21). Younger age, lower BMI and hypertension were associated with decreased plaque burden. Lower BMI, hypertension and longer duration of statin therapy were associated with decreased plaque enhancement. Younger age and hypertension were associated with decreased luminal stenosis (all p < 0.05). CONCLUSION: HR-MRI can effectively evaluate plaques changes after statin therapy. Statins can reduce plaque burden and stabilize plaques. The effect of statin may have a relationship with age, BMI, hypertension, and duration of statin therapy. CLINICAL RELEVANCE STATEMENT: High-resolution MRI can be applied to evaluate the efficacy of statins on symptomatic intracranial atherosclerotic plaques. Long-term statin use and well-controlled blood lipid levels can help reduce plaque burden and stabilize plaques. KEY POINTS: High-resolution MRI provides great help evaluating the changes of plaque characteristics after statin therapy. Efficacy of statins is associated with duration of use, controlled lipid levels, and clinical factors. High-resolution MRI can serve as an effective method for following-up symptomatic intracranial atherosclerosis.

3.
Eur Radiol ; 34(8): 5204-5214, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38224377

RESUMEN

OBJECTIVES: Wall remodeling and inflammation accompany symptomatic unruptured intracranial aneurysms (UIAs). The volume transfer constant (Ktrans) of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) reflects UIA wall permeability. Aneurysmal wall enhancement (AWE) on vessel wall MRI (VWI) is associated with inflammation. We hypothesized that Ktrans is related to symptomatic UIAs and AWE. METHODS: Consecutive patients with UIAs were prospectively recruited for 3-T DCE-MRI and VWI from January 2018 to March 2023. UIAs were classified as asymptomatic and symptomatic if associated with sentinel headache or oculomotor nerve palsy. Ktrans and AWE were assessed on DCE-MRI and VWI, respectively. AWE was evaluated using the AWE pattern and wall enhancement index (WEI). Spearman's correlation coefficient and univariate and multivariate analyses were used to assess correlations between parameters. RESULTS: We enrolled 82 patients with 100 UIAs (28 symptomatic and 72 asymptomatic). The median Ktrans (2.1 versus 0.4 min-1; p < 0.001) and WEI (1.5 versus 0.4; p < 0.001) were higher for symptomatic aneurysms than for asymptomatic aneurysms. Ktrans (odds ratio [OR]: 1.60, 95% confidence interval [95% CI]: 1.01-2.52; p = 0.04) and WEI (OR: 3.31, 95% CI: 1.05-10.42; p = 0.04) were independent risk factors for symptomatic aneurysms. Ktrans was positively correlated with WEI (Spearman's coefficient of rank correlation (rs) = 0.41, p < 0.001). The combination of Ktrans and WEI achieved an area under the curve of 0.81 for differentiating symptomatic from asymptomatic aneurysms. CONCLUSIONS: Ktrans may be correlated with symptomatic aneurysms and AWE. Ktrans and WEI may provide an additional value than the PHASES score for risk stratification of UIAs. CLINICAL RELEVANCE STATEMENT: The volume transfer constant (Ktrans) from DCE-MRI perfusion is associated with symptomatic aneurysms and provides additional value above the clinical PHASES score for risk stratification of intracranial aneurysms. KEY POINTS: • The volume transfer constant is correlated with intracranial aneurysm symptoms and aneurysmal wall enhancement. • Dynamic contrast-enhanced and vessel wall MRI facilitates understanding of the pathophysiological characteristics of intracranial aneurysm walls. • The volume transfer constant and wall enhancement index perform better than the traditional PHASES score in differentiating symptomatic aneurysms.


Asunto(s)
Medios de Contraste , Aneurisma Intracraneal , Imagen por Resonancia Magnética , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos , Anciano , Permeabilidad , Adulto
4.
Eur Radiol ; 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38856782

RESUMEN

OBJECTIVES: Aneurysm wall enhancement (AWE) on high-resolution contrast-enhanced vessel wall MRI (VWMRI) is an emerging biomarker for intracranial aneurysms (IAs) stability. Quantification methods of AWE in the literature, however, are variable. We aimed to determine the optimal post-contrast timing to quantify AWE in both saccular and fusiform IAs. MATERIALS AND METHODS: Consecutive patients with unruptured IAs were prospectively recruited. VWMRI was acquired on 1 pre-contrast and 4 consecutive post-contrast phases (each phase was 9 min). Signal intensity values of cerebrospinal fluid (CSF) and aneurysm wall on pre- and 4 post-contrast phases were measured to determine the aneurysm wall enhancement index (WEI). AWE was also qualitatively analyzed on post-contrast images using previous grading criteria. The dynamic changes of AWE grade and WEI were analyzed for both saccular and fusiform IAs. RESULTS: Thirty-four patients with 42 IAs (27 saccular IAs and 15 fusiform IAs) were included. The changes in AWE grade occurred in 8 (30%) saccular IAs and 6 (40%) in fusiform IAs during the 4 post-contrast phases. The WEI of fusiform IAs decreased 22.0% over time after contrast enhancement (p = 0.009), while the WEI of saccular IAs kept constant during the 4 post-contrast phases (p > 0.05). CONCLUSIONS: When performing quantitative analysis of AWE, acquiring post-contrast VWMRI immediately after contrast injection achieves the strongest AWE for fusiform IAs. While the AWE degree is stable for 36 min after contrast injection for saccular IAs. CLINICAL RELEVANCE STATEMENT: The standardization of imaging protocols and analysis methods for AWE will be helpful for imaging surveillance and further treatment decisions of patients with unruptured IAs. KEY POINTS: Imaging protocols and measurements of intracranial aneurysm wall enhancement are reported heterogeneously. Aneurysm wall enhancement for fusiform intracranial aneurysms (IAs) is strongest immediately post-contrast, and stable for 36 min for saccular IAs. Future multi-center studies should investigate aneurysm wall enhancement as an emerging marker of aneurysm growth and rupture.

5.
Eur Radiol ; 34(7): 4610-4618, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38108888

RESUMEN

OBJECTIVES: In patients with an unruptured intracranial aneurysm, gadolinium enhancement of the aneurysm wall is associated with growth and rupture. However, most previous studies did not have a longitudinal design and did not adjust for aneurysm size, which is the main predictor of aneurysm instability and the most important determinant of wall enhancement. We investigated whether aneurysm wall enhancement predicts aneurysm growth and rupture during follow-up and whether the predictive value was independent of aneurysm size. MATERIALS AND METHODS: In this multicentre longitudinal cohort study, individual patient data were obtained from twelve international cohorts. Inclusion criteria were as follows: 18 years or older with ≥ 1 untreated unruptured intracranial aneurysm < 15 mm; gadolinium-enhanced aneurysm wall imaging and MRA at baseline; and MRA or rupture during follow-up. Patients were included between November 2012 and November 2019. We calculated crude hazard ratios with 95%CI of aneurysm wall enhancement for growth (≥ 1 mm increase) or rupture and adjusted for aneurysm size. RESULTS: In 455 patients (mean age (SD), 60 (13) years; 323 (71%) women) with 559 aneurysms, growth or rupture occurred in 13/194 (6.7%) aneurysms with wall enhancement and in 9/365 (2.5%) aneurysms without enhancement (crude hazard ratio 3.1 [95%CI: 1.3-7.4], adjusted hazard ratio 1.4 [95%CI: 0.5-3.7]) with a median follow-up duration of 1.2 years. CONCLUSIONS: Gadolinium enhancement of the aneurysm wall predicts aneurysm growth or rupture during short-term follow-up, but not independent of aneurysm size. CLINICAL RELEVANCE STATEMENT: Gadolinium-enhanced aneurysm wall imaging is not recommended for short-term prediction of growth and rupture, since it appears to have no additional value to conventional predictors. KEY POINTS: • Although aneurysm wall enhancement is associated with aneurysm instability in cross-sectional studies, it remains unknown whether it predicts risk of aneurysm growth or rupture in longitudinal studies. • Gadolinium enhancement of the aneurysm wall predicts aneurysm growth or rupture during short-term follow-up, but not when adjusting for aneurysm size. • While gadolinium-enhanced aneurysm wall imaging is not recommended for short-term prediction of growth and rupture, it may hold potential for aneurysms smaller than 7 mm.


Asunto(s)
Aneurisma Roto , Medios de Contraste , Gadolinio , Aneurisma Intracraneal , Angiografía por Resonancia Magnética , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Femenino , Masculino , Estudios Longitudinales , Aneurisma Roto/diagnóstico por imagen , Persona de Mediana Edad , Angiografía por Resonancia Magnética/métodos , Anciano , Estudios de Cohortes
6.
J Biomech Eng ; : 1-26, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39225677

RESUMEN

Background Ascending thoracic aortic aneurysms (aTAA) can lead to life-threatening dissection and rupture. Recent studies highlighted aTAA mechanical properties as relevant factors associated with progression. The aim of this study was to quantify in vivo aortic wall stretch in healthy participants and aTAA patients using displacement encoding with stimulated echoes (DENSE) MRI. Moreover, aTAA wall stretch between surgical and non-surgical patients were investigated. Finally, DENSE measurements were compared to reference-standard mechanical testing on aTAA specimens from surgical repairs. Methods In total, 18 subjects were recruited, six healthy participants and 12 aTAA patients, for this prospective study. ECG-gated DENSE imaging was performed to measure systole-diastole wall stretch, as well as the ratio of aTAA stretch to unaffected descending thoracic aorta stretch. Free-breathing and breath-held DENSE protocols were used. Uniaxial tensile testing-measured indices were correlated to DENSE measurements in five specimens. Results In vivo aortic wall stretch was significantly lower in aTAA compared to healthy subjects (P=.0004). There was no correlation between stretch and maximum aTAA diameter. The ratio of aTAA to unaffected thoracic aorta wall stretch was significantly lower in surgical candidates compared to non-surgical candidates (P=.0442). Finally, in vivo aTAA wall stretch correlated to wall failure stress and peak modulus of the intima (P=.017 and P=.034, respectively), while the stretch ratio correlated to whole-wall thickness failure stretch and stress (P=.013 and P=.040, respectively). Conclusion Aortic DENSE has the potential to assess differences in aTAA mechanical properties and progressions.

7.
Small ; 19(15): e2207135, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36610055

RESUMEN

Electrocatalytic hydrogen evolution is an important approach to produce clean energy, and many electrocatalysts (e.g., platinum) are developed for hydrogen production. However, the electrocatalytic efficiency of commonly used metal catalysts needs to be improved to compensate their high cost. Herein, the electrocatalytic efficiency of platinum nanoparticles (PtNPs) in hydrogen evolution is largely improved via simple surface adsorption of sub-monolayer p-aminothiophenol (PATP) molecules. The overpotential goes down to 86.1 mV, which is 50.2 mV lower than that on naked PtNPs. This catalytic activity is even better than that of 20 wt.% Pt/C, despite the much smaller active surface area of PATP-adsorbed PtNPs than Pt/C. It is theoretically and experimentally confirmed that the improved electrocatalytic activity in hydrogen evolution can be attributed to the change in electronic structure of PtNPs induced by surface adsorption of PATP molecules. More importantly, this strategy can also be used to improve the electrocatalytic activity of palladium, gold, and silver nanoparticles. Therefore, this work provides a simple, convenient, and versatile method for improving the electrocatalytic activity of metal nanocatalysts. This surface adsorption strategy may also be used for improving the efficiency of many other nanocatalysts in many reactions.

8.
J Magn Reson Imaging ; 58(4): 1258-1267, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36747321

RESUMEN

BACKGROUND: Abdominal aortic aneurysms (AAAs) may rupture before reaching maximum diameter (Dmax ) thresholds for repair. Aortic wall microvasculature has been associated with elastin content and rupture sites in specimens, but its relation to progression is unknown. PURPOSE: To investigate whether dynamic contrast-enhanced (DCE) MRI of AAA is associated with Dmax or growth. STUDY TYPE: Prospective. POPULATION: A total of 27 male patients with infrarenal AAA (mean age ± standard deviation = 75 ± 5 years) under surveillance with DCE MRI and 2 years of prior follow-up intervals with computed tomography (CT) or MRI. FIELD STRENGTH/SEQUENCE: A 3-T, dynamic three-dimensional (3D) fast gradient-echo stack-of-stars volumetric interpolated breath-hold examination (Star-VIBE). ASSESSMENT: Wall voxels were manually segmented in two consecutive slices at the level of Dmax . We measured slope to 1-minute and area under the curve (AUC) to 1 minute and 4 minutes of the signal intensity change postcontrast relative to that precontrast arrival, and, Ktrans , a measure of microvascular permeability, using the Patlak model. These were averaged over all wall voxels for association to Dmax and growth rate, and, over left/right and anterior/posterior quadrants for testing circumferential homogeneity. Dmax was measured orthogonal to the aortic centerline and growth rate was calculated by linear fit of Dmax measurements. STATISTICAL TESTS: Pearson correlation and linear mixed effects models. A P value <0.05 was considered statistically significant. RESULTS: In 44 DCE MRIs, mean Dmax was 45 ± 7 mm and growth rate in 1.5 ± 0.4 years of prior follow-up was 1.7 ± 1.2 mm per year. DCE measurements correlated with each other (Pearson r = 0.39-0.99) and significantly differed between anterior/posterior versus left/right quadrants. DCE measurements were not significantly associated with Dmax (P = 0.084, 0.289, 0.054 and 0.255 for slope, AUC at 1 minute and 4 minutes, and Ktrans , respectively). Slope and 4 minutes AUC significantly associated with growth rate after controlling for Dmax . CONCLUSION: Contrast uptake may be increased in lateral aspects of the AAA. Contrast enhancement 1-minute slope and 4-minutes AUC may be associated with a period of recent AAA growth that is independent of Dmax . EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Aneurisma de la Aorta Abdominal , Humanos , Masculino , Estudios Prospectivos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/complicaciones , Aorta , Progresión de la Enfermedad , Imagen por Resonancia Magnética/métodos
9.
J Magn Reson Imaging ; 2023 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-38156373

RESUMEN

BACKGROUND: The clinical value of myocardial torsion quantification in prognostic assessment and risk stratification of various cardiovascular diseases is gradually being recognized. However, normal values of left and right ventricular (LV and RV) torsion and torsion rates (TRs) have not been fully determined, and their correlation with age and gender has not been well studied. PURPOSE: To establish normal ranges of biventricular torsion, peak systolic and diastolic TRs using magnetic resonance feature tracking (MR-FT) technique based on a large sample of healthy adults, and further investigate their relationship with age and gender. STUDY TYPE: Retrospective. POPULATION: 566 Healthy adults (312 males, aged 43 ± 10 years; 254 females, aged 43 ± 11 years). FIELD STRENGTH/SEQUENCE: 1.5T/gradient echo. ASSESSMENT: Biventricular torsion, peak systolic, and diastolic TRs. STATISTICAL TESTS: Shapiro-Wilk test, Student's t-test, Mann-Whitney-U test, linear regression, intraclass correlation coefficient, Bland-Altman analysis. Differences were regarded as statistically significant at P < 0.05. RESULTS: Women demonstrated greater magnitudes of left ventricle (LV) torsion (1.23 ± 0.44 vs. 1.00 ± 0.42°/cm), peak systolic TR (9.69 ± 3.70 vs. 8.27 ± 3.73°/cm*sec), peak diastolic TR (-7.78 ± 2.82 vs. -6.06 ± 2.44°/cm*sec), and RV torsion (2.20 ± 1.23 vs. 1.65 ± 1.11°/cm*sec), peak systolic TR (16.07 ± 8.18 vs. 12.62 ± 7.08°/cm*sec), peak diastolic TR (-15.39 ± 6.53 vs. -11.70 ± 6.03°/cm*sec). For both genders, the magnitudes of LV and RV torsion, peak systolic, and diastolic TRs increased linearly with age. All the measurements of biventricular torsion, peak systolic and diastolic TRs achieved good to excellent intraobserver and interobserver reproducibility, with all intraclass correlation coefficients >0.70. DATA CONCLUSION: The present study systematically provided age- and sex-stratified reference values for LV and RV torsion and TRs using MR-FT technique. Women and aging are associated with greater magnitudes of biventricular torsion, peak systolic, and diastolic TRs. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

10.
Eur Radiol ; 33(10): 6970-6980, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37081300

RESUMEN

OBJECTIVES: Intracranial and extracranial plaque features on high-resolution vessel wall imaging (HR-VWI) are associated with large-artery atherosclerosis (LAA) stroke recurrence. However, most studies have focused on a single vascular bed, and the prognostic value of combined intracranial and extracranial plaque features has yet to be studied. This study aimed to investigate the roles of plaque features, plaque number, and co-existing atherosclerosis in predicting stroke recurrence, utilizing combined head-and-neck HR-VWI. METHODS: From September 2016 to March 2020, participants with acute LAA ischemic strokes were prospectively enrolled and underwent combined head-and-neck HR-VWI. The participants were followed for stroke recurrence for at least 12 months or until a subsequent event occurred. The imaging features at baseline, including conventional and histogram plaque features, plaque number, and co-existing atherosclerosis, were evaluated. Univariable Cox regression analysis and the least absolute shrinkage and selection operator (lasso) method were used for variable screening. Multivariable Cox regression analyses were used to determine the independent risk factors of stroke recurrence. RESULTS: A total of 97 participants (59 ± 12 years, 63 men) were followed for a median of 30.9 months, and 21 participants experienced recurrent strokes. Multivariable Cox analysis identified co-existing intracranial high signal on T1-weighted fat-suppressed images (HST1) and extracranial carotid atherosclerosis (HR, 6.12; 95% CI, 2.52-14.82; p = 0.001) as an independent imaging predictor of stroke recurrence. CONCLUSION: Co-existing intracranial HST1 and extracranial carotid atherosclerosis independently predicted LAA stroke recurrence. Combined head-and-neck HR-VWI is a promising technique for atherosclerosis imaging. CLINICAL RELEVANCE STATEMENT: This prospective study using combined head-and-neck HR-VWI highlighted the necessity of both intracranial culprit plaque evaluation and multi-vascular bed assessment, adding value to the prediction of stroke recurrence. KEY POINTS: • This study highlighted the necessity of both intracranial culprit plaque evaluation and multi-vascular bed assessment, adding value to the prediction of stroke recurrence. • This prospective study using combined head-and-neck HR-VWI found co-existing intracranial HST1 and extracranial carotid atherosclerosis to be independent predictors of stroke recurrence.


Asunto(s)
Aterosclerosis , Enfermedades de las Arterias Carótidas , Arteriosclerosis Intracraneal , Placa Aterosclerótica , Accidente Cerebrovascular , Masculino , Humanos , Estudios Prospectivos , Angiografía por Resonancia Magnética/métodos , Accidente Cerebrovascular/diagnóstico , Enfermedades de las Arterias Carótidas/complicaciones , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Aterosclerosis/complicaciones , Aterosclerosis/diagnóstico por imagen , Arterias , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/diagnóstico por imagen , Arteriosclerosis Intracraneal/complicaciones , Arteriosclerosis Intracraneal/diagnóstico por imagen , Imagen por Resonancia Magnética
11.
Eur Radiol ; 33(5): 3444-3454, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36920519

RESUMEN

OBJECTIVES: To determine if three-dimensional (3D) radiomic features of contrast-enhanced CT (CECT) images improve prediction of rapid abdominal aortic aneurysm (AAA) growth. METHODS: This longitudinal cohort study retrospectively analyzed 195 consecutive patients (mean age, 72.4 years ± 9.1) with a baseline CECT and a subsequent CT or MR at least 6 months later. 3D radiomic features were measured for 3 regions of the AAA, viz. the vessel lumen only; the intraluminal thrombus (ILT) and aortic wall only; and the entire AAA sac (lumen, ILT, and wall). Multiple machine learning (ML) models to predict rapid growth, defined as the upper tercile of observed growth (> 0.25 cm/year), were developed using data from 60% of the patients. Diagnostic accuracy was evaluated using the area under the receiver operating characteristic curve (AUC) in the remaining 40% of patients. RESULTS: The median AAA maximum diameter was 3.9 cm (interquartile range [IQR], 3.3-4.4 cm) at baseline and 4.4 cm (IQR, 3.7-5.4 cm) at the mean follow-up time of 3.2 ± 2.4 years (range, 0.5-9 years). A logistic regression model using 7 radiomic features of the ILT and wall had the highest AUC (0.83; 95% confidence interval [CI], 0.73-0.88) in the development cohort. In the independent test cohort, this model had a statistically significantly higher AUC than a model including maximum diameter, AAA volume, and relevant clinical factors (AUC = 0.78, 95% CI, 0.67-0.87 vs AUC = 0.69, 95% CI, 0.57-0.79; p = 0.04). CONCLUSION: A radiomics-based method focused on the ILT and wall improved prediction of rapid AAA growth from CECT imaging. KEY POINTS: • Radiomic analysis of 195 abdominal CECT revealed that an ML-based model that included textural features of intraluminal thrombus (if present) and aortic wall improved prediction of rapid AAA progression compared to maximum diameter. • Predictive accuracy was higher when radiomic features were obtained from the thrombus and wall as opposed to the entire AAA sac (including lumen), or the lumen alone. • Logistic regression of selected radiomic features yielded similar accuracy to predict rapid AAA progression as random forests or support vector machines.


Asunto(s)
Aneurisma de la Aorta Abdominal , Trombosis , Humanos , Anciano , Estudios Retrospectivos , Estudios Longitudinales , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal , Tomografía Computarizada por Rayos X
12.
Neurosurg Rev ; 46(1): 123, 2023 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-37195327

RESUMEN

Interleukin-1 (IL-1) could induce inflammation of the aneurysm wall, which might be related to intracranial aneurysm rupture. The aim of this study was to investigate whether IL-1 could serve as a biomarker to predict the risk of rebleeding after admission. Data between January 2018 and September 2020 were collected from patients with ruptured intracranial aneurysms (RIAs) and were retrospectively reviewed. The serum IL-1ß and IL-1ra levels were detected using a panel, and IL-1 ratio was calculated as the log10 (IL-1ra/IL-1ß). The predictive accuracy of IL-1 compared with previous clinical morphology (CM) model and other risk factors were evaluated by the c-statistic. Five hundred thirty-eight patients were finally included in the study, with 86 rebleeding RIAs. The multivariate Cox analysis confirmed aspect ratio (AR) > 1.6 (hazard ratio (HR), 4.89 [95%CI, 2.76-8.64], P < 0.001), size ratio (SR) > 3.0 (HR, 2.40 [95%CI, 1.34-4.29], P = 0.003), higher serum IL-1ß (HR, 1.88 [95%CI, 1.27-2.78], P = 0.002), and lower serum IL-1ra (HR, 0.67 [95%CI, 0.56-0.79], P < 0.001) as the independent risk factors for rebleeding after admission. According to the c-statistics, the IL-1 ratio had the highest predictive accuracy (0.82), followed by IL-1ra and IL-1ß (0.80), AR > 1.6 (0.79), IL-1ra (0.78), IL-1ß (0.74), and SR > 3.0 (0.56), respectively. Subgroup analysis based on AR and SR presented similar results. The model combining IL-1 ratio and CM model showed higher predictive accuracy for the rebleeding after admission (c-statistic, 0.90). Serum IL-1, especially IL-1 ratio, could serve as a biomarker to predict the risk of rebleeding after admission.


Asunto(s)
Aneurisma Roto , Interleucina-1 , Aneurisma Intracraneal , Humanos , Aneurisma Roto/cirugía , Biomarcadores , Proteína Antagonista del Receptor de Interleucina 1 , Aneurisma Intracraneal/complicaciones , Aneurisma Intracraneal/cirugía , Estudios Retrospectivos , Interleucina-1/sangre , Interleucina-1/química
13.
Exp Eye Res ; 218: 108938, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35120872

RESUMEN

PURPOSE: To investigate the effect of Aspirin Triggered-Resolvin D1 (AT-RvD1) as an anti-pyroptosis and anti-inflammatory agent on lipopolysaccharide (LPS) induced acute keratitis in Wistar rats. METHODS: Acute keratitis in rats were induced by LPS stromal injection. Inflammatory reaction was measured by clinical score and histological observations. The non-canonical pyroptosis, the role of AT-RvD1 and Docosahexaenoic Acid (DHA) on non-canonical pyroptosis, were verified by quantification real-time PCR (qRT-PCR) and Western-blot. Besides, Human corneal epithelial cells (HCECs) primed with LPS, were stimulated with Nigericin, AT-RvD1 and necrosulfonamide (NSA), a Gasdermin-D (GSDMD) inhibitor separately. CCK-8 tests and flow cytometry were conducted to evaluate the cell viability and death ratio. And the marker of non-canonical pyroptosis were verified by Western blot. RESULTS: AT-RvD1 and DHA both alleviated the inflammation of rat cornea through inhibiting the expression of Caspase-11 and p30 which was triggered by LPS. Meanwhile, the activation of Caspase-4 and p30 were also significantly suppressed by AT-RvD1 in vitro, which is consistent with the results in rats. CONCLUSIONS: The non-canonical pyroptosis signaling pathways played an important role in rats with acute keratitis. In addition, AT-RvD1 can exert as an anti-inflammatory activity by inhibiting the non-canonical pyroptosis. Hence, it may be a promising and safe agent in treating acute keratitis.


Asunto(s)
Ácidos Docosahexaenoicos , Queratitis , Animales , Antiinflamatorios , Aspirina/farmacología , Caspasas , Ácidos Docosahexaenoicos/farmacología , Inflamación , Queratitis/tratamiento farmacológico , Lipopolisacáridos/toxicidad , Piroptosis , Ratas , Ratas Wistar
14.
Eur Radiol ; 32(4): 2384-2392, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34643780

RESUMEN

OBJECTIVES: To compare the visibility of intracranial aneurysm wall and thickness quantification between 7 and 3 T vessel wall imaging and evaluate the association between aneurysm size and wall thickness. METHODS: Twenty-nine patients with 29 unruptured intracranial aneurysms were prospectively recruited for 3D T1-weighted vessel wall MRI at both 3 T and 7 T with 0.53 mm (3 T) and 0.4 mm (7 T) isotropic resolution, respectively. Two neuroradiologists independently evaluated wall visibility (0-5 Likert scale), quantified the apparent wall thickness (AWT) using a semi-automated full-width-half-maximum method, calculated wall sharpness, and measured the wall-to-lumen contrast ratio (CRwall/lumen). RESULTS: Twenty-four patients with 24 aneurysms were included in this study. 7 T achieved significantly better aneurysm wall visibility than 3 T (3.6 ± 1.1 vs 2.7 ± 0.8, p = 0.003). AWT measured on 3 T and 7 T had a good correlation (averaged r = 0.63 ± 0.19). However, AWT on 3 T was 15% thicker than that on 7 T (0.52 ± 0.07 mm vs 0.45 ± 0.05 mm, p < 0.001). Wall sharpness on 7 T was 57% higher than that on 3 T (1.95 ± 0.32 mm-1 vs 1.24 ± 0.15 mm-1, p < 0.001). CRwall/lumen on 3 T and 7 T was comparable (p = 0.424). AWT on 7 T was positively correlated with aneurysm size (saccular: r = 0.58, q = 0.046; fusiform: r = 0.67, q = 0.049). CONCLUSIONS: 7 T provides better visualization of intracranial aneurysm wall with higher sharpness than 3 T. 3 T overestimates the wall thickness relative to 7 T. Aneurysm wall thickness is positively correlated with aneurysm size. 7 T MRI is a promising tool to evaluate aneurysm wall in vivo. KEY POINTS: • 7 T provides better visualization of intracranial aneurysm wall with higher sharpness than 3 T. • 3 T overestimates the wall thickness comparing with 7 T. • Aneurysm wall thickness is positively correlated with aneurysm size.


Asunto(s)
Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos
15.
J Cardiovasc Magn Reson ; 24(1): 63, 2022 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-36404299

RESUMEN

BACKGROUND: As a noninvasive tool, myocardial deformation imaging may facilitate the early detection of cardiac dysfunction. However, normal reference ranges of myocardial strain and strain rate (SR) based on large-scale East Asian populations are still lacking. This study aimed to provide reference values of left ventricular (LV) and right ventricular (RV) strain and SR based on a large cohort of healthy Chinese adults using cardiovascular magnetic resonance (CMR) feature tracking (FT). METHODS: Five hundred and sixty-six healthy Chinese adults (55.1% men) free of hypertension, diabetes, and obesity were included. On cine CMR, biventricular global radial, circumferential, and longitudinal strain (GRS, GCS, and GLS), and the peak radial, circumferential, and longitudinal systolic, and diastolic SRs (PSSRR, PSSRC, PSSRL, PDSRR, PDSRC, and PDSRL), and regional radial and circumferential strain at the basal, mid-cavity, and apical levels were measured. Associations of global and regional biventricular deformation indices with age and sex were investigated. RESULTS: Women demonstrated greater magnitudes of LV GRS (37.6 ± 6.1% vs. 32.1 ± 5.3%), GCS (- 20.7 ± 1.9% vs. - 18.8 ± 1.9%), GLS (- 17.8 ± 1.8% vs. - 15.6 ± 1.8%), RV GRS (25.1 ± 7.8% vs. 22.1 ± 6.7%), GCS (- 14.4 ± 3.6% vs. - 13.2 ± 3.2%), GLS (- 22.4 ± 5.2% vs. - 20.2 ± 4.6%), and biventricular peak systolic and diastolic SR in all three coordinate directions (all P < 0.05). For the LV, aging was associated with increasing amplitudes of GRS, GCS, and decreasing amplitudes of PDSRR, PDSRC, PDSRL (all P < 0.05). For the RV, aging was associated with an increase in the magnitudes of GRS, GCS, GLS, PSSRR, PSSRC, PSSRL, and a decrease in the magnitude of PDSRR, PDSRC (all P < 0.05). Biventricular radial and circumferential strain measurements at the basal, mid-cavity, and apical levels were all significantly related to age and sex in both sexes (all P < 0.05). CONCLUSIONS: We provide age- and sex-specific normal values of biventricular strain and SR based on a large sample of healthy Chinese adults with a broad age range. These results may be served as a reference standard for cardiac function assessment, especially for the Chinese population.


Asunto(s)
Imagen por Resonancia Cinemagnética , Función Ventricular Izquierda , Humanos , Adulto , Masculino , Femenino , Valores de Referencia , Imagen por Resonancia Cinemagnética/métodos , Valor Predictivo de las Pruebas , Espectroscopía de Resonancia Magnética , China
16.
J Chem Phys ; 157(8): 084307, 2022 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-36050007

RESUMEN

The fine and hyperfine interactions in PbF have been studied using the laser-induced fluorescence (LIF) spectroscopy method. Cold PbF molecular beam was produced by laser-ablating a Pb rod under jet-cooled conditions, followed by the reaction with SF6. The LIF excitation spectrum of the (0, 0) band in the B2Σ+-X2Π1/2 system of the 208PbF, 207PbF, and 206PbF isotopologues has been recorded with rotational, fine structure, and hyperfine-structure resolution. Transitions in the LIF spectrum were assigned and combined with the previous X2Π3/2-X2Π1/2 emission spectrum in the near-infrared region [Ziebarth et al., J. Mol. Spectrosc. 191, 108-116 (1998)] and the X2Π1/2 state pure rotational spectrum of PbF [Mawhorter et al., Phys. Rev. A 84, 022508 (2011)] in a global fit to derive the rotational, spin-orbit, spin-rotation, and hyperfine interaction parameters of the ground (X2Π1/2) and the excited (B2Σ+) electronic states. Molecular constants determined in the present work are compared with previously reported values. Particularly, the significance of the hyperfine parameters, A⊥ and A‖, of 207Pb is discussed.

17.
Ophthalmic Res ; 65(6): 712-721, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35926478

RESUMEN

INTRODUCTION: Crystalline lens is the major dioptric component and varies with refractive status. In this study, we aim to evaluate the changes of dimensions and functions of crystalline lens in high myopia (HM) and its correlated variables using CASIA2 swept-source optical coherence tomography. METHODS: One hundred and thirty eligible eyes of myopic patients from 18 to 40 years old were enrolled and divided into low-to-moderate myopia (LMM) and HM groups according to spherical equivalent (SE). Anterior segment features, including lens thickness (LT), anterior radius of curvature (ARC), posterior radius of curvature (PRC), anterior chamber depth (ACD), and lens tilt were obtained by CASIA2. Lens power was calculated using Bennett's formula. Sixty-seven participants were imaged at the static state and the accommodative state induced by -3 diopter (D) stimulus. RESULTS: Compared to the LMM group, the HM group exhibited a significantly reduction in LT, ARC, and lens tilt (all p < 0.01). Each parameter correlated positively with SE (all p < 0.01). Lens power increased with LT and tilt (r = 0.42, 0.45) but decreased with ARC and axial length (AL) (r = -0.37, -0.62) among highly myopic eyes. Multivariate regression analysis revealed that lower lens power appeared to be independently associated with axial elongation in both groups (LMM: ß = -1.124, p = 0.002; HM: ß = -1.603, p < 0.001, respectively). Decreases in ARC and ACD were accompanied by accommodative response in each group, while PRC reduced during accommodation (p = 0.009) only in HM. CONCLUSIONS: Young adults with HM presented a thinner thickness, smaller tilt, less lens power, and higher accommodative response. Lens shape was closely associated with SE; however, AL was a meaningful indicator of lens power.


Asunto(s)
Cristalino , Tomografía de Coherencia Óptica , Humanos , Adolescente , Adulto Joven , Adulto , Cristalino/diagnóstico por imagen
18.
J Cell Physiol ; 236(7): 4944-4953, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33368268

RESUMEN

Obesity causes many reproductive dysfunctions such as reduced conception, infertility, and early pregnancy loss, and this is largely due to the negative effects of obesity on oocyte and embryo quality. In the present study, we employed single-cell RNA transcriptome sequencing to investigate the potential causes for the maternal obesity effects on mouse embryos. Our results showed that the 4-cell and morula/blastocyst rates were all significantly decreased during embryo development in obese mice. Genome-wide analysis indicated that obesity altered the expression of more than 1100 genes in 2-cell embryos, including the genes which were related to the p53 signaling pathway and apoptosis. Further analysis showed that the expression of 47 genes related to DNA damage was changed, and a positive γH2A signal and the altered expression of Rad51 and Tex15 were observed in the obese embryos. Obesity also affected histone methylation, shown by the decrease of the H3K4-me2 level. Besides this, we observed the occurrence of autophagy and apoptosis in the embryos of obese mice. There were 42 genes that were related to autophagy/apoptosis that showed aberrant expression, and the positive LC3 signal and the decrease of Clec16a, Rraga, and Atg10 level were also observed. In summary, our study suggested that obesity affected early embryonic development by inducing DNA damage, aberrant histone methylation, and autophagy levels in mice.


Asunto(s)
Autofagia/fisiología , Metilación de ADN/genética , Reparación del ADN/genética , Desarrollo Embrionario/fisiología , Obesidad Materna/patología , Animales , Apoptosis/fisiología , Blastocisto/fisiología , Proteínas de Ciclo Celular/biosíntesis , Desarrollo Embrionario/genética , Femenino , Regulación del Desarrollo de la Expresión Génica/genética , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Obesos , Oocitos/citología , Embarazo , Recombinasa Rad51/biosíntesis , Análisis de la Célula Individual , Transcriptoma
19.
Stroke ; 52(1): 356-365, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33302795

RESUMEN

The utility and necessity of pretreatment with intravenous thrombolysis (IVT) before mechanical thrombectomy (MT) remains an issue of strong debate. This study aims to compare the outcomes of bridging thrombolysis (BT, IVT+MT) with direct MT (d-MT) after large vessel ischemic stroke based on the most up-to-date evidence. MEDLINE, EMBASE, Scopus, and the Cochrane Library from January 2017 to June 2020 were searched for studies that directly compared the outcomes of the 2 strategies. Methodological quality was assessed using the Quality in Prognostic Studies tool. Combined estimates of odds ratios (ORs) of BT versus d-MT were derived. Multiple subgroup analyses were performed, especially for IVT-eligible patients. Thirty studies involving 7191 patients in the BT group and 4891 patients in the d-MT group were included. Methodological quality was generally high. Compared with patients in the d-MT group, patients in the BT group showed significantly better functional independence (modified Rankin Scale score 0-2) at 90 days (OR=1.43 [95% CI, 1.28-1.61]), had lower mortality at 90 days (OR=0.67 [95% CI, 0.60-0.75]), and achieved higher successful recanalization (modified Thrombolysis in Cerebral Ischemia score 2b-3) rate (OR=1.23 [95% CI, 1.07-1.42]). No significant difference was detected in the occurrence of symptomatic intracranial hemorrhage between 2 groups (OR=1.01 [95% CI, 0.86-1.19]). Subgroup analysis showed that functional independence frequency remained significantly higher in BT group regardless of IVT eligibility or study design. Compared with d-MT, bridging with IVT led to better clinical outcomes, lower mortality at 90 days, and higher successful recanalization rates, without increasing the risk of near-term hemorrhagic complications. The benefits of BT based on this most recent literature evidence support the current guidelines of using BT.


Asunto(s)
Arteriopatías Oclusivas/terapia , Accidente Cerebrovascular/terapia , Trombectomía/métodos , Terapia Trombolítica/métodos , Terapia Combinada , Humanos , Resultado del Tratamiento
20.
Stroke ; 52(1): 213-222, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33349014

RESUMEN

BACKGROUND AND PURPOSE: Aneurysmal wall enhancement (AWE) on vessel wall magnetic resonance imaging (VW-MRI) has been described as a new imaging biomarker of unstable unruptured intracranial aneurysms (UIAs). Previous studies of symptomatic UIAs are limited due to small sample sizes and lack of AWE quantification. Our study aims to investigate whether qualitative and quantitative assessment of AWE can differentiate symptomatic and asymptomatic UIAs. METHODS: Consecutive patients with UIAs were prospectively recruited for vessel wall magnetic resonance imaging at 3T from October 2014 to October 2019. UIAs were categorized as symptomatic if presenting with sentinel headache or oculomotor nerve palsy directly related to the aneurysm. Evaluation of wall enhancement included enhancement pattern (0=none, 1=focal, and 2=circumferential) and quantitative wall enhancement index (WEI). Univariate and multivariate analyses were used to identify the parameters associated with symptoms. RESULTS: Two hundred sixty-seven patients with 341 UIAs (93 symptomatic and 248 asymptomatic) were included in this study. Symptomatic UIAs more frequently showed circumferential AWE than asymptomatic UIAs (66.7% versus 17.3%, P<0.001), as well as higher WEI (median [interquartile range], 1.3 [1.0-1.9] versus 0.3 [0.1-0.9], P<0.001). In multivariate analysis, both AWE pattern and WEI were independent factors associated with symptoms (odds ratio=2.03 across AWE patterns [95% CI, 1.21-3.39], P=0.01; odds ratio=3.32 for WEI [95% CI, 1.51-7.26], P=0.003). The combination of AWE pattern and WEI had an area under the curve of 0.91 to identify symptomatic UIAs, with a sensitivity of 95.7% and a specificity of 73.4%. CONCLUSIONS: In a large cohort of UIAs with vessel wall magnetic resonance imaging, both AWE pattern and WEI were independently associated with aneurysm-related symptoms. The qualitative and quantitative features of AWE can potentially be used to identify unstable intracranial aneurysms.


Asunto(s)
Vasos Sanguíneos/diagnóstico por imagen , Aneurisma Intracraneal/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Aneurisma Roto/diagnóstico por imagen , Angiografía de Substracción Digital , Área Bajo la Curva , Angiografía Cerebral , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Aneurisma Intracraneal/terapia , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Prospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA