RESUMEN
BACKGROUND: Severe first-degree atrioventricular (AV) block may produce symptoms similar to heart failure due to AV dyssynchrony, a syndrome termed AV dromotropathy. According to guidelines, it should be considered for permanent pacemaker implantation, yet evidence supporting this treatment is scarce. OBJECTIVES: This study aimed to determine the impact of AV-optimized conduction system pacing (CSP) in patients with symptomatic severe first-degree AV block and echocardiographic signs of AV dyssynchrony. METHODS: Patients with symptomatic first-degree AV block (PR > 250 ms), preserved left ventricular ejection fraction, narrow QRS, and AV dyssynchrony were included in the study. In a single-blind cross-over design, patients were randomized to AV sequential CSP or backup VVI pacing with a base rate of 40 bpm. We compared exercise capacity, echocardiographic parameters, and symptom occurrence at the end of 3 months of each period. RESULTS: Fourteen patients completed the study. During the AV-optimized CSP compared to the backup pacing period, patients achieved a higher workload on exercise test (147.2 ± 50.9 vs. 140.7 ± 55.8 W; p = .032), with a trend towards higher peak VO2 (23.3 ± 7.1 vs. 22.8 ± 7.1 mL/min/kg; p = .224), and higher left ventricular stroke volume (LVSV 74.5 ± 13.8 vs. 66.4 ± 12.5 mL; p < .001). Symptomatic improvement was recorded, with fewer patients reporting general tiredness and 71% of patients preferring the AV-optimized CSP (p = .008). CONCLUSIONS: AV-optimized CSP could improve symptoms, exercise capacity and LVSV in patients with severe first-degree AV block.
Asunto(s)
Bloqueo Atrioventricular , Estimulación Cardíaca Artificial , Estudios Cruzados , Tolerancia al Ejercicio , Frecuencia Cardíaca , Función Ventricular Izquierda , Humanos , Masculino , Femenino , Resultado del Tratamiento , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/diagnóstico , Anciano , Método Simple Ciego , Persona de Mediana Edad , Factores de Tiempo , Potenciales de Acción , Recuperación de la Función , Volumen Sistólico , Nodo Atrioventricular/fisiopatología , Índice de Severidad de la EnfermedadRESUMEN
AIMS: Primary prevention patients with ischaemic cardiomyopathy and chronic total occlusion of an infarct-related coronary artery (CTO) are at a particularly high risk of implantable cardioverter-defibrillator (ICD) therapy occurrence. The trial was designed to evaluate the efficacy of preventive CTO-related substrate ablation strategy in ischaemic cardiomyopathy patients undergoing primary prevention ICD implantation. METHODS AND RESULTS: The PREVENTIVE VT study was a prospective, multicentre, randomized trial including ischaemic patients with ejection fraction ≤40%, no documented ventricular arrhythmias (VAs), and evidence of scar related to the coronary CTO. Patients were randomly assigned 1:1 to a preventive substrate ablation before ICD implantation or standard therapy with ICD implantation only. The primary outcome was a composite of appropriate ICD therapy or unplanned hospitalization for VAs. Secondary outcomes included the primary outcome's components, the incidence of appropriate ICD therapies, cardiac hospitalization, electrical storm, and cardiovascular (CV) mortality. Sixty patients were included in the study. During the mean follow-up of 44.7 ± 20.7 months, the primary outcome occurred in 5 (16.7%) patients undergoing preventive substrate ablation and in 13 (43.3%) patients receiving only ICD [hazard ratio (HR): 0.33; 95% confidence interval (CI): 0.12-0.94; P = 0.037]. Patients in the preventive ablation group also had fewer appropriate ICD therapies (P = 0.039) and the electrical storms (Log-rank: P = 0.01). While preventive ablation also reduced cardiac hospitalizations (P = 0.006), it had no significant impact on CV mortality (P = 0.151). CONCLUSION: Preventive ablation of the coronary CTO-related substrate in patients undergoing primary ICD implantation is associated with the reduced risk of appropriate ICD therapy or unplanned hospitalization due to VAs.
Asunto(s)
Ablación por Catéter , Oclusión Coronaria , Desfibriladores Implantables , Isquemia Miocárdica , Prevención Primaria , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Oclusión Coronaria/mortalidad , Oclusión Coronaria/terapia , Oclusión Coronaria/prevención & control , Oclusión Coronaria/complicaciones , Resultado del Tratamiento , Estudios Prospectivos , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/mortalidad , Taquicardia Ventricular/prevención & control , Taquicardia Ventricular/terapia , Taquicardia Ventricular/mortalidad , Cardiomiopatías/mortalidad , Cardiomiopatías/complicaciones , Cardiomiopatías/terapia , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Factores de Riesgo , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Infarto del Miocardio/mortalidad , Infarto del Miocardio/prevención & control , Infarto del Miocardio/complicaciones , Enfermedad Crónica , Factores de TiempoRESUMEN
Background: "Ablate and pace" strategy is a reasonable treatment option in refractory atrial fibrillation (AF) when sinus rhythm (SR) cannot be achieved with catheter ablation or pharmacological therapy. Atrioventricular node ablation (AVNA) combined with conduction system pacing (CSP), with left bundle branch pacing (LBBP) or His bundle pacing (HBP), is gaining recognition since it offers the most physiological activation of the left ventricle. However, the incidence of conversion to SR after AVNA with CSP is not known. The purpose of the investigation was to determine the incidence of spontaneous conversion to SR and its predicting factors in patients undergoing CSP and AVNA. Methods: Consecutive refractory symptomatic AF patients undergoing AVNA with CSP at our institution between June 2018 and December 2022 were retrospectively analyzed. Twelve lead electrocardiogram (ECG) recordings were analyzed at each outpatient follow-up visit. Echocardiographic and clinical parameters were assessed at baseline and six months after the implantation. Results: Sixty-eight patients (male 42.6%, age 71 ± 8 years, left ventricular ejection fraction 40 ± 15%) were included. Thirty-seven patients (54.4%) received HBP and 31 (45.6%) LBBP. During follow-up, spontaneous conversion to SR was registered in 6 patients (8.8%); 3 in the HBP group and 3 in the LBBP group. Baseline characteristics of patients who converted to SR did not differ from non-sinus rhythm (NSR) patients except for left atrial volume index (LAVI), which was significantly smaller in the SR group (45 mL/ m 2 (41-51) vs. 60 mL/ m 2 (52-75); p = 0.002). Multiple regression model confirmed an inverse association between LAVI and conversion to SR even after considering other clinically relevant covariates (odds ratio 1.273, p = 0.028). At follow-up, LAVI did not change in any group (SR: p = 0.345; NSR: p = 0.508). Improvement in New York Heart Association (NYHA) class was comparable in both groups. Conclusions: Spontaneous conversion to SR after AVNA combined with CSP is not uncommon, especially in patients with smaller left atria. Further studies are warranted to clarify which patients should be considered for initial dual-chamber device implantation to provide atrio-ventricular synchrony in case of SR restoration.
RESUMEN
Background: Treatment with a coronary sinus reducer (CSR) is a new therapeutic option for refractory angina patients. Preclinical studies have shown antiarrhythmic properties of coronary sinus narrowing. The possible antiarrhythmic effect of CSR implantation is unknown. This study aimed to determine the possible antiarrhythmic effects of CSR implantation as assessed by high-resolution electrocardiogram (hrECG) parameters. Methods: 24 patients from the Crossroad study randomized to either CSR treatment (n = 12) or a sham procedure (n = 12) had hrECG recorded at baseline and after 6 months. T-peak and T-end interval (TpTe) defined as the time difference between the peak amplitude of the T wave and the global end of the T wave, spatial angle between QRS complex and T axis defined as the angle between the ventricular depolarization and repolarization vectors using maximal (QRSTP) and mean (QRSTM) vector amplitudes and spatial ventricular gradient (SVG) calculated as integral of ECG voltages over the entire QRST complex were analyzed. Additionally, we analyzed parameters of QT and heart rate variability using time and frequency domain. Results: At baseline, all analyzed parameters were comparable between both groups and heart rate remained constant. The intragroup analysis did not show any significant change in TpTe, QRSTP, QRSTM, SVG, QT, and heart rate variability at follow-up. Furthermore, intergroup comparison between CSR implantation and sham procedure also did not show any significant difference in the change of analyzed parameters. Conclusions: Compared to the sham procedure, CSR implantation did not demonstrate a significant impact on the arrhythmogenic substrate assessed with hrECG. Clinical Trial Registration: Unique Identifier: NCT04121845, https://classic.clinicaltrials.gov/ct2/show/NCT04121845.
RESUMEN
BACKGROUND: Left bundle branch area pacing (LBBAP) is an alternative to right ventricular (RV) and biventricular (BiV) pacing in patients scheduled for pace and ablate treatment strategy. However, current delivery sheaths are designed for left-sided implantation, making the right-sided LBBAP lead implantation challenging. CASE PRESENTATION: We report a case of a right-sided LBBAP approach via right subclavian vein in a heart failure patient with a persistent left superior vena cava scheduled for pace and ablate treatment of refractory atrial flutter. To enable adequate lead positioning and support for transseptal screwing, the delivery sheath was manually modified with a 90-degree curve at the right subclavian vein and superior vena cava junction to allow right-sided implantation. The distance between the reshaping point and the presumed septal region was estimated by placing the sheath on the body surface under fluoroscopy. With the reshaping of the delivery sheath, we were able to achieve LBBAP with relatively minimal torque. Radiofrequency ablation of the atrioventricular node was performed the next day and the pacing parameters remained stable in short-term follow-up. CONCLUSION: With the modification of currently available tools, LBBAP can be performed with the right-sided approach.
Asunto(s)
Terapia de Resincronización Cardíaca , Vena Cava Superior Izquierda Persistente , Humanos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/cirugía , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía , Estimulación Cardíaca Artificial , Nodo Atrioventricular/cirugía , Arritmias Cardíacas , Fascículo Atrioventricular/cirugía , Electrocardiografía , Resultado del TratamientoRESUMEN
PURPOSE: The aim of this study was to evaluate the safety and efficacy of zero-fluoroscopy (ZF) catheter ablation (CA) for supraventricular tachycardias (SVT). METHODS: 584 consecutive patients referred to our institution for CA of SVT were analysed. Patients were categorised into two groups; zero-fluoroscopy (ZF) group and conventional fluoroscopy (CF) group. The ZF group was further divided into two subgroups (adults and paediatric). Patient characteristics, procedural information, and follow-up data were compared. RESULTS: The ZF group had a higher proportion of paediatric patients (42.2% vs 0.0%; p < 0.001), resulting in a younger age (30.9 ± 20.3 years vs 52.7 ± 16.5 years; p < 0.001) and lower BMI (22.8 ± 5.7 kg/m2 vs 27.0 ± 5.4 kg/m2; p < 0.001). Procedure time was shorter in the ZF group (94.2 ± 50.4 min vs 104.0 ± 54.0 min; p = 0.002). There were no major complications and the rate of minor complications did not differ between groups (0.0% vs 0.4%; p = 0.304). Acute procedural success as well as the long-term success rate when only the index procedure was considered did not differ between groups (92.5% vs 95.4%; p = 0.155; 87.1% vs 89.2%; p = 0.422). When repeated procedures were included, the long-term success rate was higher in the ZF group (98.3% vs 93.5%; p = 0.004). The difference can be partially explained by the operators' preferences. CONCLUSION: The safety and efficacy of ZF procedures in adult and paediatric populations are comparable to that of CF procedures.
Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Adolescente , Adulto , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Niño , Fluoroscopía , Humanos , Persona de Mediana Edad , Taquicardia Supraventricular/diagnóstico por imagen , Taquicardia Supraventricular/cirugía , Factores de Tiempo , Resultado del Tratamiento , Adulto JovenRESUMEN
BACKGROUND: Conventional fluoroscopy guided catheter ablation (CA) is an established treatment option for ventricular arrhythmias (VAs). However, with the complex nature of most procedures, patients and staff bare an increased radiation exposure. Near-zero or zero-fluoroscopy CA is an alternative method which could substantially reduce or even eliminate the radiation dose. Our aim was to analyse procedural outcomes with fluoroscopy minimising approach for treatment of VAs in patients with structurally normal hearts (SNH) and structural heart disease (SHD). METHODS: Fifty-two (age 53.4 ± 17.8 years, 38 male, 14 female) consecutive patients who underwent CA of VAs in our institution between May 2018 and December 2019 were included. Procedures were performed primarily with the aid of the three-dimensional electro-anatomical mapping system and intra-cardiac echocardiography. Fluoroscopy was considered only in left ventricular (LV) summit mapping for coronary angiography and when epicardial approach was planned. Acute and long-term procedural outcomes were analysed. RESULTS: Sixty CA procedures were performed. Twenty-five patients had SHD-related VAs (Group 1) and 27 patients had SNH (Group 2). While Group 1 had significantly higher total procedural time (256.9 ± 71.7 vs 123.6 ± 42.2 min; p < 0.001) compared to Group 2, overall procedural success rate [77.4% (24/31) vs 89.7% (26/29); p = 0.20)] and recurrence rate after the first procedure [8/25, (32%) vs 8/27, (29.6%); p = 0.85] were similar in both groups. Fluoroscopy was used in 3 procedures in Group 1 where epicardial approach was needed and in 4 procedures in Group 2 where LV summit VAs were ablated. Overall procedure-related major complication rate was 5%. CONCLUSIONS: Fluoroscopy minimising approach for CA of VAs is feasible and safe in patients with SHD and SNH. Fluoroscopy could not be completely abolished in VAs with epicardial and LV summit substrate location.
Asunto(s)
Arritmias Cardíacas/cirugía , Ablación por Catéter , Ecocardiografía , Exposición a la Radiación/prevención & control , Protección Radiológica , Radiografía Intervencional , Ultrasonografía Intervencional , Adulto , Anciano , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Ablación por Catéter/efectos adversos , Ecocardiografía/efectos adversos , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Factores Protectores , Dosis de Radiación , Exposición a la Radiación/efectos adversos , Radiografía Intervencional/efectos adversos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional/efectos adversosRESUMEN
Pediatric patients with complete congenital atrio-ventricular (AV) block are generally exposed to life-long dyssynchronous right ventricular (RV) pacing. His bundle pacing (HBP) is an alternative method of pacing that better restores physiological ventricular activation which could prevent pacing-induced cardiomyopathy. We present a case of a 5-year-old child with complete AV block who underwent successful permanent HBP implantation. Three-dimensional electro-anatomical mapping system was used to facilitate the procedure and reduce the fluoroscopy time. There were no acute procedure-related complications, and electrical parameters were stable at short-term follow-up.
Asunto(s)
Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/métodos , Mapeo Epicárdico , Cardiopatías Congénitas/terapia , Bloqueo Atrioventricular/congénito , Preescolar , Electrocardiografía , Femenino , Fluoroscopía , HumanosRESUMEN
BACKGROUND: Intracardiac echocardiography (ICE) has become an all-round tool for ablation of atrial fibrillation (AF) since it plays an important role in all procedural steps. The key upgrade to the usefulness of ICE is its integration into three-dimensional (3D) electroanatomic mapping (EAM) system (ICE/EAM automatic integration system). The aim of this single-center retrospective study was to evaluate feasibility, safety and acute efficacy of ICE/EAM automatic integration system guided fluoroless ablation of AF. METHODS: The study included patients with symptomatic paroxysmal or persistent AF undergoing first pulmonary vein isolation (PVI) radiofrequency (RF) catheter ablation (RFCA) from September 2017 to August 2020. All procedures were performed without the use of fluoroscopy. A detailed 3D virtual anatomy of the left atrium (LA) and structures relevant to AF ablation was constructed from ultrasound contours obtained with ICE probe inside the LA. Pulmonary veins (PVs) and antral regions were additionally mapped with fast anatomical mapping (FAM). PVI was performed with contact force (CF) sensing catheter. Procedural endpoint was successful PVI. RESULTS: A total of 98 consecutive patients underwent RFCA (34.7% females, median age 64.4 years, 64.3% paroxysmal AF). Acute PVI was achieved in all patients (100%). Forty-three patients (43.9%) underwent additional ablations for concomitant arrhythmias. Adverse events were detected in four patients (4.1%). The median procedure duration was 130 min (IQR 103.8-151.3). If only PVI was done the median procedure duration was 110.5 (IQR 100.0-133.8) CONCLUSIONS: ICE/EAM automatic integration system guided fluoroless ablation of AF is feasible, safe and acutely effective method for treatment of symptomatic AF.
Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Ecocardiografía Tridimensional , Venas Pulmonares/cirugía , Anciano , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Estudios RetrospectivosRESUMEN
BACKGROUND: Right free wall accessory pathways (AP) are difficult to treat with catheter ablation as ablation catheter (AC) instability at the tricuspid annulus often precludes successful procedure. The aim of our study was to test a novel intra-cardiac echocardiography (ICE) guided technique for AC placement. Feasibility and success rates were observed. METHODS: Eight consecutive patients (aged 29 ± 21 years, 4 female) with Wolff-Parkinson-White syndrome and a right free wall AP were included in the study. ICE, three-dimensional (3D) electro-anatomic mapping (EAM) system, and a steerable long sheath were used together with either an irrigated or a non-irrigated tip radio-frequency AC to achieve a "loop" manoeuvre which provided AC tip stability at the ventricular aspect of the tricuspid annulus. X-ray fluoroscopy was not used. RESULTS: Three patients had an anterior and five had a lateral location of the right free wall AP. Procedures were successful in all patients, without recurrences during the mean follow-up of 397 ± 363 days. Average procedural duration was 90 ± 31 min. On average, 6.6 ± 5.7 ablations were needed. Average time to terminate AP conduction after the start of ablation was 4.8 ± 4.2 s. In five patients (62%) AP conduction was successfully terminated with the first ablation. There were no procedural complications. CONCLUSIONS: The novel ICE-guided approach with concomitant use of the steerable sheath and the 3D EAM system for zero-fluoroscopy mapping and ablation of the right free wall APs proved feasible and resulted in excellent acute and long-term outcomes.
Asunto(s)
Fascículo Atrioventricular Accesorio/cirugía , Ablación por Catéter , Ecocardiografía , Ultrasonografía Intervencional , Síndrome de Wolff-Parkinson-White/cirugía , Fascículo Atrioventricular Accesorio/diagnóstico por imagen , Fascículo Atrioventricular Accesorio/fisiopatología , Potenciales de Acción , Adolescente , Adulto , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Niño , Ecocardiografía/efectos adversos , Estudios de Factibilidad , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional/efectos adversos , Síndrome de Wolff-Parkinson-White/diagnóstico por imagen , Síndrome de Wolff-Parkinson-White/fisiopatología , Adulto JovenRESUMEN
INTRODUCTION: While catheter ablation (CA) is an established treatment for symptomatic paroxysmal atrial fibrillation (AF), convergent epicardial and endocardial ablation procedure (CVP) has been primarily used to treat persistent AF. The aim of this single-center, prospective, randomized study was to compare treatment efficacy of CA and CVP in paroxysmal AF patients by monitoring AF, atrial tachycardia (AT), and atrial flutter (AFL) recurrence with Implantable Loop Recorder (ILR). METHODS AND RESULTS: Fifty patients (74% male) with history of paroxysmal AF were randomized between CA and CVP. Outcomes were determined by ILRs; every episode of AF/AT/AFL lasting 6 minutes or more was defined as a recurrence. AF burden (AFB) and required AF reinterventions (cardioversions and repeat ablations) were quantified after a 3-month blanking period. Total procedural (266 ± 44 vs. 242 ± 39 minutes) and ablation duration (52 ± 10 vs. 48 ± 12 minutes) was similar in both groups. Recurrence of AF/AT/AFL was more likely in the CA group compared to the CVP group (OR 3.78 (95% CI (1.17, 12.19), P = 0.048)). During the follow-up period (mean 30.5 ± 6.9 months), higher AF burden and more reinterventions for recurrent AF were recorded in the CA group. There were more periprocedural complications in the CVP group (12.5%) compared to the CA group (0%). CONCLUSION: Treatment of paroxysmal AF with CVP showed less arrhythmia recurrence compared to CA. In addition, patients after CVP had fewer reinterventions and lower AF burden, but more periprocedural complications.
Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/prevención & control , Ablación por Catéter/métodos , Desfibriladores Implantables , Electrocardiografía Ambulatoria/métodos , Anciano , Fibrilación Atrial/fisiopatología , Ablación por Catéter/tendencias , Desfibriladores Implantables/tendencias , Electrocardiografía Ambulatoria/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del TratamientoRESUMEN
BACKGROUND: Cardiac resynchronization therapy (CRT) induces structural and electrical remodeling (ER) in heart failure (HF) patients. Our aim was to assess time course of ER of native conduction and mechanical remodeling after CRT and impact of CRT-induced ER on clinical outcome. METHODS AND RESULTS: We prospectively included 62 patients (aged 66 ± 10 years). Echocardiographic and ECG parameters were measured at baseline and 1, 3, 6, 9, and 12 months after implantation. Biventricular pacing was temporary inhibited during each follow-up to record intrinsic ECG. ER was defined as a decrease in native pre-implantation QRS duration ≥10 ms. During follow-up HF hospitalizations, cardiovascular death and transplantation (combined end point) were recorded. There were significant changes in intrinsic ECG parameters during follow-up; the narrowing of QRS duration was already observed after 1 month (median 185 ms [interquartile range (IQR) 175-194] vs 180 ms [170-194]; P < .001). Left ventricular (LV) volumes decreased only after 3 months of CRT (median end-systolic volume 167 mL [137-206] vs 140 mL [112-196]; P < .001). Only patients with ER (n = 24) exhibited significant mechanical remodeling and showed superior survival free from the combined end point compared with patients without ER (log-rank P = .028). CONCLUSIONS: Electrical remodeling of native conduction precedes detectable left ventricular structural changes after CRT. ER of native conduction is associated with better clinical outcome following CRT.
Asunto(s)
Remodelación Atrial , Terapia de Resincronización Cardíaca/métodos , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Remodelación Ventricular , Anciano , Ecocardiografía , Electrocardiografía/métodos , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca/fisiología , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del TratamientoRESUMEN
BACKGROUND: Cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients. However, determinants of response to CRT remain elusive. The aim of the study was to assess the value of ECG parameters to predict super-response in CRT patients. METHODS: A 12-lead surface ECG was recorded at baseline and immediately after CRT-device implantation. Baseline ECG parameters (QRS duration, bundle branch morphology, axis, PR interval, QTc, intrinsicoid deflection) and post-implant paced QRS duration were analyzed; relative change in QRS duration was calculated. Decrease of left ventricular end-systolic volume ≥30% after 12 months was classified as super-response. RESULTS: In group of 101 patients, 32 (31.7%) were super-responders. There were no significant differences in baseline ECG parameters between super-responders and other patients. Post-implant QRS duration was shorter in super-responders (148 ± 22 ms vs. 162 ± 28 ms; P=0.010). Only in super-responders was significant QRS reduction observed after implantation. Relative QRS shortening was higher in super-responders (12.1% (6.8 to 22.2) vs. 1.7% (-11.9 to 11.8); P=0.005). In a multivariable analysis post-implant QRS duration and relative QRS shortening remained independent predictor of super-response. CONCLUSION: Absolute post-implant QRS duration and relative QRS shortening are the only ECG parameters associated with super-response in CRT. Further prospective studies on larger population are warranted to determine our findings.
Asunto(s)
Terapia de Resincronización Cardíaca , Diagnóstico por Computador/métodos , Electrocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/prevención & control , Evaluación de Resultado en la Atención de Salud/métodos , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del TratamientoRESUMEN
Atrial fibrillation and heart failure with preserved ejection fraction (HFpEF) are frequent concomitant diseases sharing several pathophysiological mechanisms leading to structural remodelling of both atria and ventricles. We present a case of an HFpEF patient with rapid atrial fibrillation who remained symptomatic even after successful cardioversion, initiation of antiarrhythmic therapy, and treatment of comorbidities. Due to asymmetric septal hypertrophy, the stress test was performed to exclude outflow tract obstruction and revealed a low basal heart rate with significant chronotropic insufficiency. In addition to SGLT2 initiation, the beta-blocker dose was reduced, and amiodarone was discontinued. This therapy modification led to a marked improvement in exercise capacity, significant reduction of palpitations, reduction of NT-proBNP, and signs of a decreased left ventricular filling pressure with reverse remodelling of LA. This case shows the importance of both individual tailoring of medical therapy and chronotropic insufficiency in HFpEF patients.
Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Volumen Sistólico , Humanos , Volumen Sistólico/fisiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/terapia , Masculino , Anciano , Comorbilidad , Función Ventricular Izquierda/fisiología , EcocardiografíaRESUMEN
BACKGROUND: The presence of myocardial fibrosis is associated with ventricular tachyarrhythmia (VT) occurrence irrespective of cardiomyopathy etiology. The aim of our study was to evaluate the impact of global and regional viability on VTs in patients undergoing cardiac resynchronization therapy (CRT). METHODS: Fifty-seven patients with advanced heart failure (age 62.3 ± 10.2; 38 men; 24 ischemic etiology) were evaluated using single-photon emission computed tomography myocardial perfusion imaging before CRT defibrillator device implantation. Global myocardial viability was determined by the number of viable segments in a 20-segment model. Regional viability was calculated as the mean tracer activity in the corresponding segments at left ventricular (LV) lead position. LV lead segments were determined at implant venography using 2 projections (left anterior oblique 30 and right anterior oblique 30) of coronary sinus tributaries. Patients were followed 30 (24-34) months for the occurrence of VTs. RESULTS: VTs were registered in 18 patients (31.6%). Patients without VTs had significantly more viable segments (17.6 ± 2.35 vs 14.2 ± 4.0; P = .002) and higher regional myocardial viability at LV lead position (66.1% ± 10.3% vs 54.8% ± 11.4% of tracer activity; P = .001) than those with VTs. In multivariate logistic regression models, the number of viable segments (OR = 0.66; 95% confidence interval (CI) 0.53-0.85; P = .001) and regional viability (OR = 0.90; 95% CI 0.85-0.97; P = .003) were the only independent predictors of VT occurrence. CONCLUSION: Global and regional myocardial viability are independently related to the occurrence of VTs in patients after CRT.
Asunto(s)
Terapia de Resincronización Cardíaca , Imagen de Perfusión Miocárdica/métodos , Taquicardia Ventricular/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Ecocardiografía , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Taquicardia Ventricular/etiologíaRESUMEN
Cardiac involvement in systemic light chain amyloidosis carries poor prognosis. Amyloid deposition in the myocardium can alter regional left ventricular contraction and cause dyssynchrony. Cardiac resynchronization therapy (CRT) is an effective treatment strategy for patients with advanced heart failure and echocardiographic dyssynchrony. We report a clinical and echocardiographic response of a patient with amyloid cardiomyopathy, treated with a combination of chemotherapy and CRT.
Asunto(s)
Amiloidosis/terapia , Terapia de Resincronización Cardíaca/métodos , Cardiomiopatías/terapia , Anciano , Amiloidosis/diagnóstico , Biopsia , Cardiomiopatías/diagnóstico por imagen , Ecocardiografía , Estudios de Seguimiento , Humanos , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas , Masculino , Piel/patologíaRESUMEN
Coronary sinus reducer (CSR) implantation is a new treatment option for patients with refractory angina pectoris. However, there is no evidence from a randomized trial that would show an improvement in exercise capacity after this treatment. The aim of this study was to evaluate the influence of CSR treatment on maximal oxygen consumption and compare it to a sham procedure. Twenty-five patients with refractory angina pectoris (Canadian Cardiovascular Society (CCS) class II-IV) were randomized to a CSR implantation (n = 13) or a sham procedure (n = 12). At baseline and after 6 months of follow-up, the patients underwent symptom-limited cardiopulmonary exercise testing with an adjusted ramp protocol and assessment of angina pectoris using the CCS scale and Seattle angina pectoris questionnaire (SAQ). In the CSR group, maximal oxygen consumption increased from 15.56 ± 4.05 to 18.4 ± 5.2 mL/kg/min (p = 0.03) but did not change in the sham group (p = 0.53); p for intergroup comparison was 0.03. In contrast, there was no difference in the improvement of the CCS class or SAQ domains. To conclude, in patients with refractory angina and optimized medical therapy, CSR implantation may improve oxygen consumption beyond that of optimal medical therapy.
RESUMEN
Background: Aortic regurgitation is a major concern following transcatheter aortic valve implantation (TAVI), as even low-grade regurgitation is associated with increased mortality. This is of particular concern to patients with pre-existing aortic disease who are at increased risk of TAVI valve slippage. Furthermore, conduction system disturbances after TAVI, namely left bundle branch block (LBBB), may have an additional detrimental effect on cardiac function. Case presentation: This report documents a successful treatment strategy in a frail patient with a bicuspid aortic valve and aortic disease after valve-sparing surgical repair in 1998, who subsequently developed aortic stenosis and underwent TAVI with an Evolut R self-expanding aortic valve. The progression of aortic disease, aortic root dilatation, and leaflet degeneration over the following years caused aortic regurgitation of the self-expanding aortic valve, resulting in left ventricular dilatation and heart failure along with LBBB and left ventricular (LV) mechanical dyssynchrony. Diagnostic workup of the patient showed persistence of the aneurysm distal to the graft with a dissection spanning the ascending aorta, arch, and terminating proximal to the aortic isthmus. After consideration by the cardiac team, a balloon-expandable valve was chosen for a valve-in-valve (ViV) procedure to provide sufficient radial force to expand the existing valve and correct the regurgitation. Due to the anatomy, a J-wire and pigtail catheter were successfully used for a safe approach and placement of the valve. Following the procedure, intermittent complete atrioventricular block was observed in addition to the pre-existing left bundle branch block, necessitating resynchronization pacing. Due to anatomical considerations, ease of placement, and the expected good level of resynchronization due to the proximal block, we opted for left bundle branch pacing, which showed improvement in left ventricular dyssynchrony and LV function at follow-up. Conclusion: Valve-in-valve implantation of a balloon-expandable Myval TAVI device to treat aortic regurgitation caused by slippage and right leaflet disfunction of slef valve is feasible in challenging anatomical scenarios. Left bundle branch pacing is a viable alternative to correct mechanical dyssynchrony in complex patients with LBBB and anatomical challenges necessitating resynchronization.