Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Phys Med ; 35: 25-30, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28236559

RESUMEN

PURPOSE: External dosimetry audits give confidence in the safe and accurate delivery of radiotherapy. The RTTQA group have performed an on-site audit programme for trial recruiting centres, who have recently implemented static or rotational IMRT, and those with major changes to planning or delivery systems. METHODS: Measurements of reference beam output were performed by the host centre, and by the auditor using independent equipment. Verification of clinical plans was performed using the ArcCheck helical diode array. RESULTS: A total of 54 measurement sessions were performed between May 2014 and June 2016 at 28 UK institutions, reflecting the different combinations of planning and delivery systems used at each institution. Average ratio of measured output between auditor and host was 1.002±0.006. Average point dose agreement for clinical plans was -0.3±1.8%. Average (and 95% lower confidence intervals) of gamma pass rates at 2%/2mm, 3%/2mm and 3%/3mm respectively were: 92% (80%), 96% (90%) and 98% (94%). Moderately significant differences were seen between fixed gantry angle and rotational IMRT, and between combination of planning systems and linac manufacturer, but not between anatomical treatment site or beam energy. CONCLUSION: An external audit programme has been implemented for universal and efficient credentialing of IMRT treatments in clinical trials. Good agreement was found between measured and expected doses, with few outliers, leading to a simple table of optimal and mandatory tolerances for approval of dosimetry audit results. Feedback was given to some centres leading to improved clinical practice.


Asunto(s)
Ensayos Clínicos como Asunto/normas , Garantía de la Calidad de Atención de Salud , Radiometría/normas , Radioterapia de Intensidad Modulada/normas , Habilitación Profesional , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia de Intensidad Modulada/instrumentación , Radioterapia de Intensidad Modulada/métodos , Reino Unido
2.
Radiother Oncol ; 120(1): 114-8, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27046390

RESUMEN

BACKGROUND AND PURPOSE: FAST-Forward is a phase 3 clinical trial testing a 1-week course of whole breast radiotherapy against the UK standard 3-week regimen after primary surgery for early breast cancer. Two acute skin toxicity substudies were undertaken to test the safety of the test schedules with respect to early skin reactions. MATERIAL AND METHODS: Patients were randomly allocated to 40Gy/15 fractions (F)/3-weeks, 27Gy/5F/1-week or 26Gy/5F/1-week. Acute breast skin reactions were graded using RTOG (first substudy) and CTCAE criteria v4.03 (second substudy) weekly during treatment and for 4weeks after treatment ended. Primary endpoint was the proportion of patients within each treatment group with grade ⩾3 toxicity (RTOG and CTCAE, respectively) at any time from the start of radiotherapy to 4weeks after completion. RESULTS: 190 and 162 patients were recruited. In the first substudy, evaluable patients with grade 3 RTOG toxicity were: 40Gy/15F 6/44 (13.6%); 27Gy/5F 5/51 (9.8%); 26Gy/5F 3/52 (5.8%). In the second substudy, evaluable patients with grade 3 CTCAE toxicity were: 40Gy/15F 0/43; 27Gy/5F 1/41 (2.4%); 26Gy/5F 0/53. CONCLUSIONS: Acute breast skin reactions with two 1-week schedules of whole breast radiotherapy under test in FAST-Forward were mild.


Asunto(s)
Neoplasias de la Mama/radioterapia , Mama/efectos de la radiación , Piel/efectos de la radiación , Femenino , Humanos , Traumatismos por Radiación , Radiodermatitis , Dosificación Radioterapéutica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA