Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Strahlenther Onkol ; 185(1): 27-33, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19224144

RESUMEN

PURPOSE: : To report on the clinical outcome of hypofractionated conformal radiotherapy (HCRT) for medically inoperable stage I non-small cell lung carcinoma (NSCLC) or limited pulmonary metastases or = 4 months were considered suitable for analysis. Local response was evaluated with CT imaging 4 months after the end of HCRT and every 3 months thereafter. Local relapse-free survival (LRFS) and overall survival (OS) were calculated with the Kaplan-Meier method. RESULTS: : Local response to the treatment was complete response, partial response, no change, and progressive disease as seen in 29%, 43%, 14%, and 7% of tumors, respectively. LRFS at 1 year and 3 years was 76% and 63%, respectively. Lung toxicities > or = grade 2 were observed in 4/40 patients, but no grade 4. Pericardial effusion occurred in one patient. In stage I NSCLC patients (n = 15) with a median follow-up of 25 months, the 1-year LRFS and OS rates were 88% and 81%, respectively, and the 3-year rates 72% and 61%, respectively. CONCLUSION: : HCRT is an effective and low-toxic treatment for medically inoperable early-stage lung cancers and pulmonary metastases for all clinicians lacking the aid of a dedicated stereotactic system.


Asunto(s)
Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/secundario , Radioterapia Conformacional/métodos , Anciano , Anciano de 80 o más Años , Fraccionamiento de la Dosis de Radiación , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Radiografía , Dosificación Radioterapéutica , Radioterapia Conformacional/efectos adversos , Resultado del Tratamiento
2.
J Exp Clin Cancer Res ; 27: 14, 2008 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-18593458

RESUMEN

BACKGROUND: In nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes. The activity of each "dose" must be carefully measured and documented prior to administration using an activity calibrator. METHODS: Calibrator response is a function of the measurement geometry and, in particular, it depends on the syringe type and filling volume. To minimize the uncertainty associated with the measured activity of the syringe, it is necessary to calculate a calibration curve depending on filling volume for each syringe type. This curve can be obtained by fitting experimentally determined volume correction factors. RESULTS: A theoretical evaluation of volume correction factors for syringes is reported for three different experimental methods. The aim is to determine the most accurate experimental method among those considered, by examining the expression of uncertainty for the correction factor. This theoretical analysis was then tested experimentally. CONCLUSION: The agreement between the experimental data obtained in the constant activity method and gravimetric method at constant specific activity and the small associated uncertainties show the accuracy of these two procedures; while the volumetric method at constant specific activity could lead to a wrong evaluation of the correction factors.


Asunto(s)
Medicina Nuclear/instrumentación , Radiofármacos/administración & dosificación , Calibración/normas , Modelos Teóricos , Medicina Nuclear/métodos , Medicina Nuclear/normas , Jeringas/normas , Pesos y Medidas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA