Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Cardiovasc Revasc Med ; 22: 22-28, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32591310

RESUMEN

BACKGROUND: Transcatheter mitral valve repair (TMVR) utilization has increased significantly in the United States over the last years. Yet, a risk-prediction tool for adverse events has not been developed. We aimed to generate a machine-learning-based algorithm to predict in-hospital mortality after TMVR. METHODS: Patients who underwent TMVR from 2012 through 2015 were identified using the National Inpatient Sample database. The study population was randomly divided into a training set (n = 636) and a testing set (n = 213). Prediction models for in-hospital mortality were obtained using five supervised machine-learning classifiers. RESULTS: A total of 849 TMVRs were analyzed in our study. The overall in-hospital mortality was 3.1%. A naïve Bayes (NB) model had the best discrimination for fifteen variables, with an area under the receiver-operating curve (AUC) of 0.83 (95% CI, 0.80-0.87), compared to 0.77 for logistic regression (95% CI, 0.58-0.95), 0.73 for an artificial neural network (95% CI, 0.55-0.91), and 0.67 for both a random forest and a support-vector machine (95% CI, 0.47-0.87). History of coronary artery disease, of chronic kidney disease, and smoking were the three most significant predictors of in-hospital mortality. CONCLUSIONS: We developed a robust machine-learning-derived model to predict in-hospital mortality in patients undergoing TMVR. This model is promising for decision-making and deserves further clinical validation.


Asunto(s)
Insuficiencia de la Válvula Mitral , Válvula Mitral , Teorema de Bayes , Mortalidad Hospitalaria , Humanos , Aprendizaje Automático , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estados Unidos/epidemiología
2.
Front Pharmacol ; 10: 1550, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-32038238

RESUMEN

Despite some previous examples of successful application to the field of pharmacogenomics, the utility of machine learning (ML) techniques for warfarin dose predictions in Caribbean Hispanic patients has yet to be fully evaluated. This study compares seven ML methods to predict warfarin dosing in Caribbean Hispanics. This is a secondary analysis of genetic and non-genetic clinical data from 190 cardiovascular Hispanic patients. Seven ML algorithms were applied to the data. Data was divided into 80 and 20% to be used as training and test sets. ML algorithms were trained with the training set to obtain the models. Model performance was determined by computing the corresponding mean absolute error (MAE) and % patients whose predicted optimal dose were within ±20% of the actual stabilization dose, and then compared between groups of patients with "normal" (i.e., > 21 but <49 mg/week), low (i.e., ≤21 mg/week, "sensitive"), and high (i.e., ≥49 mg/week, "resistant") dose requirements. Random forest regression (RFR) significantly outperform all other methods, with a MAE of 4.73 mg/week and 80.56% of cases within ±20% of the actual stabilization dose. Among those with "normal" dose requirements, RFR performance is also better than the rest of models (MAE = 2.91 mg/week). In the "sensitive" group, support vector regression (SVR) shows superiority over the others with lower MAE of 4.79 mg/week. Finally, multivariate adaptive splines (MARS) shows the best performance in the resistant group (MAE = 7.22 mg/week) and 66.7% of predictions within ±20%. Models generated by using RFR, MARS, and SVR algorithms showed significantly better predictions of weekly warfarin dosing in the studied cohorts than other algorithms. Better performance of the ML models for patients with "normal," "sensitive," and "resistant" to warfarin were obtained when compared to other populations and previous statistical models.

3.
JACC Cardiovasc Interv ; 12(14): 1328-1338, 2019 07 22.
Artículo en Inglés | MEDLINE | ID: mdl-31320027

RESUMEN

OBJECTIVES: This study sought to develop and compare an array of machine learning methods to predict in-hospital mortality after transcatheter aortic valve replacement (TAVR) in the United States. BACKGROUND: Existing risk prediction tools for in-hospital complications in patients undergoing TAVR have been designed using statistical modeling approaches and have certain limitations. METHODS: Patient data were obtained from the National Inpatient Sample database from 2012 to 2015. The data were randomly divided into a development cohort (n = 7,615) and a validation cohort (n = 3,268). Logistic regression, artificial neural network, naive Bayes, and random forest machine learning algorithms were applied to obtain in-hospital mortality prediction models. RESULTS: A total of 10,883 TAVRs were analyzed in our study. The overall in-hospital mortality was 3.6%. Overall, prediction models' performance measured by area under the curve were good (>0.80). The best model was obtained by logistic regression (area under the curve: 0.92; 95% confidence interval: 0.89 to 0.95). Most obtained models plateaued after introducing 10 variables. Acute kidney injury was the main predictor of in-hospital mortality ranked with the highest mean importance in all the models. The National Inpatient Sample TAVR score showed the best discrimination among available TAVR prediction scores. CONCLUSIONS: Machine learning methods can generate robust models to predict in-hospital mortality for TAVR. The National Inpatient Sample TAVR score should be considered for prognosis and shared decision making in TAVR patients.


Asunto(s)
Técnicas de Apoyo para la Decisión , Mortalidad Hospitalaria , Aprendizaje Automático , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano , Anciano de 80 o más Años , Toma de Decisiones Clínicas , Bases de Datos Factuales , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA