Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Arthroplasty ; 37(4): 802-808.e5, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34952165

RESUMEN

BACKGROUND: Total knee arthroplasty (TKA) provides successful results in most patients. Periprosthetic joint infection (PJI) accounts for up to 25% of failed TKAs needing revision. In clinical practice, consensus in diagnostic strategy for excluding or diagnosing PJI is still lacking. In this systematic review and meta-analysis, we aim to provide a simplified data-driven diagnostic strategy for aseptic knee and hip revision surgeons to rule out PJI in the outpatient clinic phase. METHODS: A literature search in EMBASE, MEDLINE, PubMed, and Cochrane was conducted. Studies involving the diagnosis of PJI in patients with failed TKAs and total hip arthroplasties needing revision were identified. Only studies using the Musculoskeletal Infection Society criteria were included. Quality was assessed using MINORS criteria. Meta-analysis was performed for each diagnostic test identified in the included studies. Pooled estimates of diagnostic accuracy measures were calculated using a bivariate model and plotted in summary receiver-operator characteristic curves. Positive and negative predictive values were calculated in a hypothetical sample of patients with a given disease prevalence. RESULTS: Twenty-four studies met the inclusion criteria, describing a total of 2974 patients. Quality scores ranged from 13 to 19. Meta-analysis could be performed on 7 unique diagnostic tests. Highest pooled sensitivity and specificity were demonstrated for α-defensin with values of 86% and 96.6%, respectively. α-defensin and white blood cell count in synovial fluid demonstrate highest negative predictive value values. CONCLUSIONS: We recommend, in a clinical setting with low-intermediate prevalence of PJI, performing arthrocentesis and joint fluid analysis using α-defensin and/or white blood cell count before revision TKA and revision total hip arthroplasty surgery to rule out PJI.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Infecciones Relacionadas con Prótesis , alfa-Defensinas , Artritis Infecciosa/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Biomarcadores , Humanos , Infecciones Relacionadas con Prótesis/cirugía , Sensibilidad y Especificidad , Líquido Sinovial/química , alfa-Defensinas/análisis
2.
Arch Orthop Trauma Surg ; 142(6): 1253-1264, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34101017

RESUMEN

INTRODUCTION: Dislocation remains a major complication in total hip arthroplasty (THA), in which femoral component orientation is considered a key parameter. New imaging modalities and definitions on femoral component orientation have been introduced, describing orientation in different planes. This study aims to systematically review the relevance of the different orientation parameters on implant stability. METHODS: A systematic review was performed according to the PRISMA guidelines to identify articles in the PubMed and EMBASE databases that study the relation between any femoral component orientation parameters and implant stability in primary THA. RESULTS: After screening for inclusion and exclusion criteria and quality assessment, nine articles were included. Definitions to describe the femoral component orientation and methodologies to assess its relevance for implant stability differed greatly, with lack of consensus. Seven retrospective case-control studies reported on the relevance of the transversal plane orientation: Low femoral- or low combined femoral and acetabular anteversion was statistical significantly related with more posterior dislocations, and high femoral- or combined femoral and acetabular anteversion with anterior dislocations in two studies. There were insufficient data on sagittal and coronal component orientation in relation to implant stability. CONCLUSION: Because of incomparable definitions, limited quality and heterogeneity in methodology of the included studies, there is only weak evidence that the degree of transverse component version is related with implant stability in primary THA. Recommendations about the optimal orientation of the femoral component in all three anatomical planes cannot be provided. Future studies should uniformly define the three-dimensional orientation of the femoral component and systematically describe implant stability.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Luxaciones Articulares , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/efectos adversos , Humanos , Luxaciones Articulares/cirugía , Estudios Retrospectivos
3.
Clin Orthop Relat Res ; 479(3): 561-571, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33009235

RESUMEN

BACKGROUND: Sagittal pelvic dynamics mainly consist of the pelvis rotating anteriorly or posteriorly while the hips flexes, and this affects the femoroacetabular or THA configuration. Thus far, it is unknown how the acetabular cup of the THA in the individual patient reorients with changing sagittal pelvic dynamics. QUESTIONS/PURPOSES: The aim of this study was to validate a method that establishes the three-dimensional (3-D) acetabular cup orientation with changing sagittal pelvic dynamics and describe these changes during functional pelvic dynamics. METHODS: A novel trigonometric mathematical model, which was incorporated into an easy-to-use tool, was tested. The model connected sagittal tilt, transverse version, and coronal inclination of the acetabular cup during sagittal pelvic tilt. Furthermore, the effect of sagittal pelvic tilt on the 3-D reorientation of acetabular cups was simulated for cups with different initial positions. Twelve pelvic CT images of patients who underwent THA were taken and rotated around the hip axis to different degrees of anterior and posterior sagittal pelvic tilt (± 30°) to simulate functional pelvic tilt in various body positions. For each simulated pelvic tilt, the transverse version and coronal inclination of the cup were manually measured and compared with those measured in a mathematical model in which the 3-D cup positions were calculated. Next, this model was applied to different acetabular cup positions to simulate the effect of sagittal pelvic dynamics on the 3-D orientation of the acetabular cup in the coronal and transverse plane. After pelvic tilt was applied, the intraclass correlation coefficients of 108 measured and calculated coronal and transverse cup orientation angles were 0.963 and 0.990, respectively, validating the clinical use of the mathematical model. RESULTS: The changes in 3-D acetabular cup orientation by functional pelvic tilt differed substantially between cups with different initial positions; the change in transverse version was much more pronounced in cups with low coronal inclination (from 50° to -29°) during functional pelvic tilt than in cups with a normal coronal inclination (from 39° to -11°) or high coronal inclination (from 31° to 2°). However, changes in coronal inclination were more pronounced in acetabular cups with high transverse version. CONCLUSION: Using a simple algorithm to determine the dynamic 3-D reorientation of the acetabular cup during functional sagittal pelvic tilt, we demonstrated that the 3-D effect of functional pelvic tilt is specific to the initial acetabular cup orientation and thus per THA patient. CLINICAL RELEVANCE: Future studies concerning THA (in)stability should not only include the initial acetabular cup orientation, but also they need to incorporate the effect of sagittal pelvic dynamics on the individual 3-D acetabular cup orientation. Clinicians can also use the developed tool, www.3d-hip.com, to calculate the acetabular cup's orientation in other instances, such as for patients with spinopelvic imbalance.


Asunto(s)
Acetábulo/fisiopatología , Modelos Teóricos , Modelación Específica para el Paciente , Pelvis/fisiopatología , Acetábulo/cirugía , Anciano , Algoritmos , Artroplastia de Reemplazo de Cadera , Femenino , Humanos , Imagenología Tridimensional , Masculino , Orientación Espacial , Pelvis/cirugía , Postura , Tomografía Computarizada por Rayos X
4.
J Arthroplasty ; 36(5): 1700-1706, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33516632

RESUMEN

BACKGROUND: Addition of vitamin E to polyethylene is theorized to reduce the potential for oxidative wear in acetabular components. This paper presents a multicenter prospective cohort study that reports on outcomes from use of a Vitamin E-infused highly cross-linked polyethylene acetabular cup. METHODS: Patients were recruited across nine medical institutions. Clinical outcome measures recorded were the Harris Hip Score, visual analogue score for pain and satisfaction. Evidence of implant loosening or osteolysis was collected radiologically. Cup survival and reasons for revision in relevant cases were also recorded. Data collection was undertaken preoperatively, at 6-12 weeks, 6 months, 1 year, 2 years, and 5 years. A total of 675 patients were recruited, with 450 cases available at final review. Data regarding cup survival was available to 8 years and 9 months postoperatively. RESULTS: Improvements in both the Harris Hip Score and visual analogue score for pain and satisfaction were recorded at all time points, with these being maintained through the length of follow-up. In total, 89% of cups were implanted within the Lewinnek safe zone. A lucent line was identified in one case, with no evidence of acetabular osteolysis observed throughout the follow-up period. Cup survival was 98.9% at 8 years and 9 months. No revisions for aseptic loosening were observed. CONCLUSIONS: The use of a vitamin E-infused polyethylene acetabular cup demonstrates reassuring patient-reported outcomes, radiological measures, and cup survival at medium to long-term follow-up.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Seguimiento , Prótesis de Cadera/efectos adversos , Humanos , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Supervivencia , Vitamina E
5.
J Arthroplasty ; 36(6): 2184-2188.e1, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33516634

RESUMEN

BACKGROUND: Anterior and posterior pelvic tilt appears to play a role in total hip arthroplasty (THA) stability. When changing from the standing to the sitting position, the pelvis typically rotates posteriorly while the hips flex and this affects the femoro-acetabular positions. This case-control study compares changes in 3-D acetabular cup orientation during functional pelvic tilt between posterior THA dislocations vs stable THAs. METHODS: Standing and sitting 3-D cup orientation was compared between fifteen posterior dislocations vs 233 prospectively followed stable THAs. 3-D cup orientation was calculated using previously validated trigonometric algorithms on biplanar radiographs. Those algorithms combine the angles in the three anatomical planes (coronal inclination, transverse version, and sagittal ante-inclination) in the standing position with the change in sagittal pelvic tilt from standing to sitting to calculate the 3-D orientation in the sitting position. RESULTS: The standing cup orientation of the dislocated THAs was only characterized by a lower coronal inclination (P = .039). Compared with the controls, from standing to sitting, they showed less posterior pelvic tilt (P < .001). This led to a significant lower coronal inclination (P < .001) and sagittal ante-inclination (P < .001) in the sitting position but similar transverse version (P = .366). CONCLUSIONS: Comparing posterior THA dislocations to stable THAs, there is a lower increase of all three orientation angles from standing to sitting. This leads to a decreased sitting coronal inclination and sagittal ante-inclination which may lead to an increased risk of impingement ensued by THA instability. By contrast, the transverse version was not significantly different in both positions. This confirms the importance of biplanar data on functional cup orientation. LEVEL OF EVIDENCE: Diagnostic, Level III.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Luxaciones Articulares , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Casos y Controles , Humanos , Postura
6.
Br J Sports Med ; 54(9): 538-545, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31227493

RESUMEN

OBJECTIVES: To examine whether physical therapy (PT) is cost-effective compared with arthroscopic partial meniscectomy (APM) in patients with a non-obstructive meniscal tear, we performed a full trial-based economic evaluation from a societal perspective. In a secondary analysis-this paper-we examined whether PT is non-inferior to APM. METHODS: We recruited patients aged 45-70 years with a non-obstructive meniscal tear in nine Dutch hospitals. Resource use was measured using web-based questionnaires. Measures of effectiveness included knee function using the International Knee Documentation Committee (IKDC) and quality-adjusted life-years (QALYs). Follow-up was 24 months. Uncertainty was assessed using bootstrapping techniques. The non-inferiority margins for societal costs, the IKDC and QALYs, were €670, 8 points and 0.057 points, respectively. RESULTS: We randomly assigned 321 patients to PT (n=162) or APM (n=159). PT was associated with significantly lower costs after 24 months compared with APM (-€1803; 95% CI -€3008 to -€838). The probability of PT being cost-effective compared with APM was 1.00 at a willingness to pay of €0/unit of effect for the IKDC (knee function) and QALYs (quality of life) and decreased with increasing values of willingness to pay. The probability that PT is non-inferior to APM was 0.97 for all non-inferiority margins for the IKDC and 0.89 for QALYs. CONCLUSIONS: The probability of PT being cost-effective compared with APM was relatively high at reasonable values of willingness to pay for the IKDC and QALYs. Also, PT had a relatively high probability of being non-inferior to APM for both outcomes. This warrants further deimplementation of APM in patients with non-obstructive meniscal tears. TRIAL REGISTRATION NUMBERS: NCT01850719 and NTR3908.


Asunto(s)
Artroscopía/economía , Meniscectomía/economía , Modalidades de Fisioterapia/economía , Lesiones de Menisco Tibial/terapia , Adulto , Anciano , Análisis Costo-Beneficio , Estudios de Equivalencia como Asunto , Femenino , Estudios de Seguimiento , Costos de la Atención en Salud , Humanos , Masculino , Persona de Mediana Edad , Lesiones de Menisco Tibial/cirugía
7.
Acta Orthop ; 91(3): 254-259, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32098534

RESUMEN

Background and purpose - The long-term survival of arthroplasty components may be limited by polyethylene wear-related problems such as periprosthetic osteolysis and aseptic loosening. Highly cross-linked polyethylene (HXLPE) blended with vitamin E was introduced to improve oxidative stability and to avoid long-term embrittlement. This study clinically compares the tribological behavior and clinical outcome of vitamin E blended HXLPE with ultra-high molecular weight polyethylene (UHMWPE) in an isoelastic monoblock cup for uncemented total hip arthroplasty.Patients and methods - In this randomized controlled trial (RCT), 199 patients were included: 102 patients received the vitamin E blended HXLPE cup, 97 patients the UHMWPE cup. Clinical and radiographic parameters were obtained preoperatively, directly postoperative and at 3, 12, and 24 months. Wear rates were compared using the mean linear femoral head penetration (FHP) rate.Results - 188 patients (94%) completed the 2-year follow-up. Mean patient satisfaction was higher in the vitamin E blended HXLPE group (8.9 [1]) than in in the control group (8.5 [2], p = 0.03). The Harris Hip Score (HHS) was higher in the vitamin E blended HXLPE group (95 [8]) than in the control group (92 [11], p = 0.3). The FHP rate was lower in the vitamin E blended HXLPE group: 0.046 mm/year compared with 0.056 mm/year in the control group (p = 0.05). No adverse reactions associated with the clinical application of vitamin E blended HXLPE were observed during follow-up, with an excellent 2-year survival to revision rate of 98% for both cups.Interpretation - This study shows the superior performance of the HXLPE blended with vitamin E acetabular cup with lower linear femoral head penetration rates and better clinical results compared with the UHMWPE acetabular cup after 2 years.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Polietileno/uso terapéutico , Polietilenos/uso terapéutico , Vitamina E/uso terapéutico , Acetábulo/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Femenino , Prótesis de Cadera/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Método Simple Ciego , Adulto Joven
8.
JAMA ; 320(13): 1328-1337, 2018 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-30285177

RESUMEN

Importance: Despite recent studies suggesting arthroscopic partial meniscectomy (APM) is not more effective than physical therapy (PT), the procedure is still frequently performed in patients with meniscal tears. Objective: To assess whether PT is noninferior to APM for improving patient-reported knee function in patients with meniscal tears. Design, Setting, and Participants: Noninferiority, multicenter, randomized clinical trial conducted in 9 hospitals in the Netherlands. Participants were aged 45 to 70 years with nonobstructive meniscal tears (ie, no locking of the knee joint). Patients with knee instability, severe osteoarthritis, and body mass index greater than 35 were excluded. Recruitment took place between July 17, 2013, and November 4, 2015. Participants were followed up for 24 months (final participant follow-up, October 11, 2017). Interventions: Three hundred twenty-one participants were randomly assigned to APM (n = 159) or a predefined PT protocol (n = 162). The PT protocol consisted of 16 sessions of exercise therapy over 8 weeks focused on coordination and closed kinetic chain strength exercises. Main Outcomes and Measures: The primary outcome was change in patient-reported knee function on the International Knee Documentation Committee Subjective Knee Form (range, 0 to 100; from worse to best) from baseline over a 24-month follow-up period. The noninferiority margin was defined as a difference between treatment groups of 8 points and was assessed with a 1-sided α of .025. The primary analysis followed the intention-to-treat principle. Results: Among 321 patients who were randomized (mean [SD] age, 58 [6.6] years; 161 women [50%]), 289 (90%) completed the trial (161 women and 158 men). In the PT group, 47 participants (29%) had APM during the 24-month follow-up period, and 8 participants randomized to APM (5%) did not have APM. Over a 24-month follow-up period, knee function improved in the APM group by 26.2 points (from 44.8 to 71.5) and in the PT group by 20.4 points (from 46.5 to 67.7). The overall between-group difference was 3.6 points (97.5% CI, -∞ to 6.5; P value for noninferiority = .001). Adverse events occurred in 18 participants in the APM group and 12 in the PT group. Repeat surgery (3 in the APM group and 1 in the PT group) and additional outpatient visits for knee pain (6 in the APM group and 2 in the PT group) were the most frequent adverse events. Conclusions and Relevance: Among patients with nonobstructive meniscal tears, PT was noninferior to APM for improving patient-reported knee function over a 24-month follow-up period. Based on these results, PT may be considered an alternative to surgery for patients with nonobstructive meniscal tears. Trial Registration: ClinicalTrials.gov Identifier: NCT01850719.


Asunto(s)
Meniscectomía , Osteoartritis de la Rodilla/complicaciones , Modalidades de Fisioterapia , Lesiones de Menisco Tibial/rehabilitación , Lesiones de Menisco Tibial/cirugía , Anciano , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/fisiología , Masculino , Meniscectomía/efectos adversos , Meniscectomía/métodos , Persona de Mediana Edad , Osteoartritis de la Rodilla/clasificación , Osteoartritis de la Rodilla/diagnóstico por imagen , Recuperación de la Función , Reoperación/estadística & datos numéricos , Índice de Severidad de la Enfermedad , Lesiones de Menisco Tibial/complicaciones
11.
Arthroscopy ; 32(9): 1855-1865.e4, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27474105

RESUMEN

PURPOSE: To conduct a meta-analysis of randomized controlled trials comparing the outcome of arthroscopic partial meniscectomy (APM) with conservative treatment in adults with nonobstructive meniscal tears and to recommend a treatment of choice. METHODS: We systematically searched the databases of MEDLINE, Excerpta Medica Database, Cochrane, the National Health Service Centre for Reviews and Dissemination, and Physiotherapy Evidence Database from inception to May 2, 2016. Two authors independently searched the literature and selected eligible studies. The meta-analyses used a random-effects model. The primary outcome was physical function, measured by knee-specific patient-reported outcomes. Secondary outcomes included knee pain, activity level, the progression of osteoarthritis, adverse events, general health, and quality of life. RESULTS: We included 6 randomized controlled trials, with a total of 773 patients, of whom 378 were randomized to APM and 395 were randomized to the control treatment. After pooling the data of 5 studies, we found small significant differences in favor of the APM group for physical function at 2 to 3 months (mean difference [MD] = 3.31; 95% confidence interval [CI] = 0.69-5.93; P = .01; I(2) = 0% [Lysholm knee score]), and at 6 months (MD = 3.56; 95% CI = 0.24-6.88; P = .04; I(2) = 0% (Knee injury and Osteoarthritis Outcome Score [KOOS] and Western Ontario and McMaster Universities Osteoarthritis Index); standardized MD = 0.17; 95% CI = 0.01-0.32; P = .03; I(2) = 0% [Lysholm knee score, KOOS, and Western Ontario and McMaster Universities Osteoarthritis Index]). We also found small significant differences for pain at 6 months (MD = 3.56; 95% CI = 0.18-6.95; P = .04; I(2) = 0% [KOOS] and MD = 0.56; 95% CI = 0.28-0.83; P ≤ .0001; I(2) = 0% [visual analog scale and numeric rating scale]). We found no significant differences after 12 and 24 months. CONCLUSIONS: We found small, although statistically significant, favorable results of APM up to 6 months for physical function and pain. However, we found no differences at longer follow-up. LEVEL OF EVIDENCE: Level I, systematic review and meta-analysis of Level I studies.


Asunto(s)
Tratamiento Conservador , Traumatismos de la Rodilla/cirugía , Meniscos Tibiales/cirugía , Osteoartritis de la Rodilla/epidemiología , Lesiones de Menisco Tibial/cirugía , Progresión de la Enfermedad , Humanos , Dimensión del Dolor , Calidad de Vida , Ensayos Clínicos Controlados Aleatorios como Asunto
12.
Foot Ankle Surg ; 22(2): 73-7, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27301724

RESUMEN

INTRODUCTION: The objective of the present study was to review the current data on the long-term outcomes of posterior malleolar fractures, with special emphasis on the role of the type of treatment, surgical approach, and reduction and internal fixation. METHODS: The search was limited to skeletally mature patients. Major databases were searched from 1978 to 2014 to identify studies relating to functional outcome, subjective outcome, and radiographic evaluation at least 2 years after either surgical or conservative treatment of posterior malleolar fractures. RESULTS: Of 68 initially relevant studies, 19 met our inclusion criteria. A total of 886 fractures were identified in 885 patients. The mean sample size-weighted follow-up period was 3.7 years. Comparable results are achieved when comparing open reduction and internal fixation to conservative treatment for posterior malleolar fractures. DISCUSSION: Current consensus suggests posterior malleolar fragments comprising of >25% of the distal tibial plafond as seen on a true lateral radiograph and fragments with more than 2mm dislocation require open reduction and internal fixation of the fragment. The current consensus on treatment of posterior malleolar fractures is neither supported nor disapproved by the available evidence.


Asunto(s)
Fracturas de Tobillo/cirugía , Fijación Interna de Fracturas , Fracturas de Tobillo/diagnóstico , Fracturas de Tobillo/epidemiología , Humanos , Resultado del Tratamiento
13.
J Arthroplasty ; 30(4): 615-21, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25496930

RESUMEN

Little is known about the clinical application of highly cross-linked polyethylene (HXLPE) blended with vitamin E. This study evaluates an uncemented iso-elastic monoblock cup with vitamin E blended HXLPE. 112 patients were followed up for 2years. 95.5% completed the follow-up. The mean VAS score for patient satisfaction was 8.8 and the mean Harris Hip Score was 94.2. In 7 cases initial gaps behind the cup were observed, which disappeared completely during follow-up in 6 cases. The mean femoral head penetration rate was 0.055mm/year. No adverse reactions or abnormal mechanical behavior was observed with the short term use of vitamin E blended HXLPE. This study shows the promising performance of this cup and confirms the potential of vitamin E blended HXLPE.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Polietileno/química , Vitamina E/química , Adulto , Anciano , Anciano de 80 o más Años , Cementos para Huesos , Elasticidad , Femenino , Cabeza Femoral/cirugía , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Estudios Prospectivos , Diseño de Prótesis
14.
BMC Musculoskelet Disord ; 15: 57, 2014 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-24568365

RESUMEN

BACKGROUND: Polyetheretherketone (PEEK) cages have been widely used in the treatment of lumbar degenerative disc disorders, and show good clinical results. Still, complications such as subsidence and migration of the cage are frequently seen. A lack of osteointegration and fibrous tissues surrounding PEEK cages are held responsible. Ceramic implants made of silicon nitride show better biocompatible and osteoconductive qualities, and therefore are expected to lower complication rates and allow for better fusion.Purpose of this study is to show that fusion with the silicon nitride cage produces non-inferior results in outcome of the Roland Morris Disability Questionnaire at all follow-up time points as compared to the same procedure with PEEK cages. METHODS/DESIGN: This study is designed as a double blind multi-center randomized controlled trial with repeated measures analysis. 100 patients (18-75 years) presenting with symptomatic lumbar degenerative disorders unresponsive to at least 6 months of conservative treatment are included. Patients will be randomly assigned to a PEEK cage or a silicon nitride cage, and will undergo a transforaminal lumbar interbody fusion with pedicle screw fixation. Primary outcome measure is the functional improvement measured by the Roland Morris Disability Questionnaire. Secondary outcome parameters are the VAS leg, VAS back, SF-36, Likert scale, neurological outcome and radiographic assessment of fusion. After 1 year the fusion rate will be measured by radiograms and CT. Follow-up will be continued for 2 years. Patients and clinical observers who will perform the follow-up visits will be blinded for type of cage used during follow-up. Analyses of radiograms and CT will be performed independently by two experienced radiologists. DISCUSSION: In this study a PEEK cage will be compared with a silicon nitride cage in the treatment of symptomatic degenerative lumbar disc disorders. To our knowledge, this is the first randomized controlled trial in which the silicon nitride cage is compared with the PEEK cage in patients with symptomatic degenerative lumbar disc disorders. TRIAL REGISTRATION: NCT01557829.


Asunto(s)
Materiales Biocompatibles , Fijadores Internos , Degeneración del Disco Intervertebral/cirugía , Cetonas , Dolor de la Región Lumbar/cirugía , Vértebras Lumbares/cirugía , Polietilenglicoles , Compuestos de Silicona , Fusión Vertebral/instrumentación , Adolescente , Adulto , Anciano , Benzofenonas , Protocolos Clínicos , Método Doble Ciego , Estudios de Seguimiento , Humanos , Degeneración del Disco Intervertebral/complicaciones , Degeneración del Disco Intervertebral/diagnóstico por imagen , Dolor de la Región Lumbar/etiología , Ensayo de Materiales , Persona de Mediana Edad , Selección de Paciente , Polímeros , Complicaciones Posoperatorias/etiología , Radiografía , Índice de Severidad de la Enfermedad , Encuestas y Cuestionarios , Adulto Joven
15.
J Arthroplasty ; 29(2): 405-9, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23768917

RESUMEN

The Morscher monoblock cup is designed for optimal osteointegration and holds the potential for excellent long-term survival. The Metasul-on-Metasul bearing was introduced to eliminate wear-induced periprosthetic osteolysis. This study reviews 137 Morscher cups with a 28-mm Metasul-on-Metasul bearing used in primary THA at 5.1years (3.2-6.6) after implantation. One hundred thirty-seven cups were implanted in 119 patients. Three patients (2.2%) had died of unrelated causes, and 10 patients (8.0%) were lost to follow-up. The mean Harris Hip score was 89.8 and the mean WOMAC sum score was 18.5. No cases of acetabular osteolysis were found. The 5-year cup survival rate was 98.5%. The Morscher cup with a 28-mm Metasul-on-Metasul bearing used in uncemented THA showed no acetabular osteolysis and promising survivorship at intermediate-term follow-up.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera , Articulación de la Cadera , Prótesis de Cadera , Artropatías/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Oseointegración , Osteólisis/etiología , Osteólisis/prevención & control , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos
16.
Clin Orthop Relat Res ; 471(11): 3572-80, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23913339

RESUMEN

BACKGROUND: Monoblock acetabular components used in uncemented total hip arthroplasty (THA) have certain mechanical characteristics that potentially reduce acetabular osteolysis and polyethylene wear. However, the degree to which they achieve this goal is not well documented. QUESTIONS/PURPOSES: The purpose of this study was to use a systematic review of controlled trials to test the hypothesis that monoblock cups have superior (1) polyethylene wear rate; (2) frequency of cup migration; (3) frequency of acetabular osteolysis; and (4) frequency of aseptic loosening compared with modular components used in uncemented THA. METHODS: A systematic search was conducted in the Medline, Embase, and Cochrane electronic databases to assemble all controlled trials comparing monoblock with modular uncemented acetabular components in primary THA. Included studies were considered "best evidence" if the quality score was either ≥ 50% on the Cochrane Back Review Group checklist or ≥ 75% the Newcastle-Ottawa quality assessment scale. A total of seven publications met our inclusion criteria. RESULTS: Best evidence analysis showed no difference in polyethylene wear rate, the frequency of cup migration, and aseptic loosening between monoblock and modular acetabular components. No convincing evidence was found for the claim that lower frequencies of acetabular osteolysis are observed with the use of monoblock cups compared with modular uncemented cups. CONCLUSIONS: The purported benefits of monoblock cups were not substantiated by this systematic review of controlled studies in that polyethylene wear rates and frequencies of cup failure and acetabular osteolysis were similar to those observed with modular implants. Other factors should therefore drive implant selection in cementless THA.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/instrumentación , Migración de Cuerpo Extraño/prevención & control , Articulación de la Cadera/cirugía , Prótesis de Cadera , Osteólisis/prevención & control , Falla de Prótesis , Acetábulo/fisiopatología , Artroplastia de Reemplazo de Cadera/efectos adversos , Benchmarking , Medicina Basada en la Evidencia , Migración de Cuerpo Extraño/etiología , Articulación de la Cadera/fisiopatología , Humanos , Osteólisis/etiología , Polietileno , Diseño de Prótesis , Estrés Mecánico , Factores de Tiempo , Resultado del Tratamiento
17.
Hip Int ; 33(6): 1079-1085, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36571206

RESUMEN

INTRODUCTION: To date the aetiology of femoroacetabular impingement (FAI) is still not completely understood. There are mechanical theories that suggest symptomatic FAI is linked to sagittal pelvic morphology and spinopelvic-femoral dynamics. The aim of this study is to evaluate the relation of sagittal pelvic morphology and orientation to radiographic signs of FAI. Additionally, we test whether the relation between FAI and spinopelvic parameters differs in osteoarthritic hips. METHODS: From a prospective, observational cohort study, 1002 patients between 45 and 65 years old with a first episode of knee or hip pain were followed for 8 years. All patients who had lateral lumbar radiographs and clinical and radiographic follow-up of the hips were included in the present study. Range of internal rotation of the hip as well as radiographic signs of FAI (alpha and Wiberg angle) and presence of hip osteoarthritis (Kellgren and Lawrence) were systematically measured at baseline. Pelvic incidence (PI), pelvic tilt (PT), sacral slope (SS)) were measured at 8-year follow-up. Associations between PI, PT, SS and FAI parameters were tested using generalised estimating equations. RESULTS: 421 subjects, 842 hips, were included. No significant relations between PI, PT or SS and alpha or Wiberg angle were found. Comparison of hips with and without radiological sign(s) of FAI showed no differences in PI, PT or SS. There was no relation between range of internal rotation of the hip and spinopelvic parameters. CONCLUSION: Sagittal pelvic morphology and orientation are not related to the presence of radiological signs of FAI in this study population.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Pinzamiento Femoroacetabular , Humanos , Persona de Mediana Edad , Anciano , Pinzamiento Femoroacetabular/cirugía , Estudios Prospectivos , Artroplastia de Reemplazo de Cadera/efectos adversos , Cadera , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía
18.
Clin Anat ; 25(6): 737-45, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22109571

RESUMEN

This anatomical and biomechanical study focuses on the specific influence of the long head of biceps brachii muscle in controlling axial humeral rotation. The tendon of the long head of the biceps brachii (biceps tendon) is shown to either facilitate or restrict axial humeral rotation. Its effect on axial humeral rotation is strongly related to firstly the amount of biceps tendon load, secondly glenohumeral scapular plane elevation, and thirdly the rotatory position of the humerus. At 0° glenohumeral elevation, biceps tendon load caused an increase of internal humeral rotation, from 0° at 2.25 N biceps tendon load to 23° at 82.25 N. Under 45° glenohumeral elevation, biceps tendon load can restrict and facilitate as well internal and external axial humeral rotation, increasing the rotatory range of motion. Above 45° glenohumeral elevation biceps tendon load restricts internal and external axial humeral rotation, increasing actively joint stability by increasing torsional rigidity. These findings on the function of the biceps tendon could have consequences for the clinical interpretation. In the elevated arm position, extreme rotation loads the long head of the biceps tendon and may turn out to biceps or bicepslabrum complex injuries.


Asunto(s)
Húmero/fisiología , Músculo Esquelético/fisiología , Tendones/fisiología , Anciano , Anciano de 80 o más Años , Humanos , Rotación , Soporte de Peso
19.
Sci Rep ; 12(1): 3499, 2022 03 03.
Artículo en Inglés | MEDLINE | ID: mdl-35241700

RESUMEN

Femoral component orientation plays a key role in implant stability and therefore the success rate of total hip arthroplasty. To date, this topic has been studied using various definitions and a variety of imaging modalities and protocols. The aim of this study is a proof of concept that a new algorithm can be used to describe the femoral component's 3D orientation on the three orthogonal anatomical planes and relative to its mechanical axis using input from two orthogonal planes. CT scans of 18 patients with a total of 22 hip arthroplasties were collected. From these, orthogonal coronal and sagittal projections of the complete femur were acquired in the scanning position (MIPs) and relative to the femoral mechanical axis (corrected MIPs). On these images, the orientation of the neck of the femoral component in space and relative to the femoral axis, respectively, was measured by coronal inclination (CIF), sagittal inclination (SIF) and transverse version (TVF). With the algorithm, TVF was also calculated based on CIF and SIF. Differences between measured and calculated TVF and intra- and inter-observer reliability were evaluated using intra-class correlation coefficients (ICC). The error of non-orthogonal imaging (85° angle between the sagittal and coronal reconstructions) was tested on a third series of MIPs. The ICC between the calculated TVF and manually measured TVF, in space and relative to the femoral axis, was 0.98 for both with median absolute differences of 1.3 and 1.5°. For non-orthogonal images this was 0.70 with a median absolute difference of 5°. ICCs for intra-observer and inter-observer reliability for the calculated TVF values were 0.98 and 0.88, respectively. With this algorithm the transverse orientation of the neck of the femoral component can be assessed in space and relative to the mechanical femoral axis by combining its sagittal and coronal orientation. As long as the imaging visualizes two orthogonal planes, the orientation of an implant can be assessed in 3-D, regardless of the imaging modality.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Algoritmos , Artroplastia de Reemplazo de Cadera/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos
20.
BMC Med ; 9: 8, 2011 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-21261971

RESUMEN

BACKGROUND: Shoulder pain is a common musculoskeletal problem that is often chronic or recurrent. Myofascial trigger points (MTrPs) cause shoulder pain and are prevalent in patients with shoulder pain. However, few studies have focused on MTrP therapy. The aim of this study was to assess the effectiveness of multimodal treatment of MTrPs in patients with chronic shoulder pain. METHODS: A single-assessor, blinded, randomized, controlled trial was conducted. The intervention group received comprehensive treatment once weekly consisting of manual compression of the MTrPs, manual stretching of the muscles and intermittent cold application with stretching. Patients were instructed to perform muscle-stretching and relaxation exercises at home and received ergonomic recommendations and advice to assume and maintain good posture. The control group remained on the waiting list for 3 months. The Disabilities of Arm, Shoulder and Hand (DASH) questionnaire score (primary outcome), Visual Analogue Scale for Pain (VAS-P), Global Perceived Effect (GPE) scale and the number of muscles with MTrPs were assessed at 6 and 12 weeks in the intervention group and compared with those of a control group. RESULTS: Compared with the control group, the intervention group showed significant improvement (P < 0.05) on the DASH after 12 weeks (mean difference, 7.7; 95% confidence interval (95% CI), 1.2 to 14.2), on the VAS-P1 for current pain (mean difference, 13.8; 95% CI, 2.6 to 25.0), on the VAS-P2 for pain in the past 7 days (mean difference, 10.2; 95% CI, 0.7 to 19.7) and VAS-P3 most severe pain in the past 7 days (mean difference, 13.8; 95% CI, 0.8 to 28.4). After 12 weeks, 55% of the patients in the intervention group reported improvement (from slightly improved to completely recovered) versus 14% in the control group. The mean number of muscles with active MTrPs decreased in the intervention group compared with the control group (mean difference, 2.7; 95% CI, 1.2 to 4.2). CONCLUSIONS: The results of this study show that 12-week comprehensive treatment of MTrPs in shoulder muscles reduces the number of muscles with active MTrPs and is effective in reducing symptoms and improving shoulder function in patients with chronic shoulder pain. TRIAL REGISTRATION NUMBER: ISRCTN: ISRCTN75722066.


Asunto(s)
Síndromes del Dolor Miofascial/complicaciones , Síndromes del Dolor Miofascial/terapia , Dolor de Hombro/complicaciones , Dolor de Hombro/terapia , Enfermedad Crónica , Humanos , Ejercicios de Estiramiento Muscular , Músculo Esquelético/patología , Participación del Paciente , Encuestas y Cuestionarios , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA