1.
Catheter Cardiovasc Interv ; 99(4): 1197-1205, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34837467

RESUMEN

OBJECTIVES: To study the safety and feasibility of a restrictive temporary-RV-pacemaker use and to evaluate the need for temporary pacemaker insertion for failed left ventricular (LV) pacing ability (no ventricular capture) or occurrence of high-degree AV-blocks mandating continuous pacing. BACKGROUND: Ventricular pacing remains an essential part of contemporary transcatheter aortic valve implantation (TAVI). A temporary-right-ventricle (RV)-pacemaker lead is the standard approach for transient pacing during TAVI but requires central venous access. METHODS: An observational registry including 672 patients who underwent TAVI between June 2018 and December 2020. Patients received pacing on the wire when necessary, unless there was a high-anticipated risk for conduction disturbances post-TAVI, based on the baseline-ECG. The follow-up period was 30 days. RESULTS: A temporary-RV-pacemaker lead (RVP-cohort) was inserted in 45 patients, pacing on the wire (LVP-cohort) in 488 patients, and no pacing (NoP-cohort) in 139 patients. A bailout temporary pacemaker was implanted in 14 patients (10.1%) in the NoP-cohort and in 24 patients (4.9%) in the LVP-cohort. One patient in the LVP-cohort needed an RV-pacemaker for incomplete ventricular capture. Procedure time was significantly longer in the RVP-cohort (68 min [IQR 52-88.] vs. 55 min [IQR 44-72] in NoP-cohort and 55 min [IQR 43-71] in the LVP-cohort [p < 0.005]). Procedural high-degree AV-block occurred most often in the RVP-cohort (45% vs. 14% in the LVP and 16% in the NoP-cohort [p ≤ 0.001]). Need for new PPI occurred in 47% in the RVP-cohort, versus 20% in the NoP-cohort and 11% in the LVP-cohort (p ≤ 0.001). CONCLUSION: A restricted RV-pacemaker strategy is safe and shortens procedure time. The majority of TAVI-procedures do not require a temporary-RV-pacemaker.


Asunto(s)
Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 98(5): E737-E745, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33533544

RESUMEN

BACKGROUND: The MANTA vascular closure device (VCD) is dedicated to large bore access closure and associated with favorable results in selected study populations. Anatomical predictors for access site complications are lacking. AIM: To evaluate MANTA in a real-world population and identify predictors for vascular complications. METHODS: All patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) between January 2016 and May 2020 with MANTA closure were included. Baseline characteristics were collected, pre-procedural computed tomography and post-deployment femoral angiograms were analyzed for anatomical differences. The primary endpoint was a composite of access site related major and minor vascular complications at 30 days follow-up according to the VARC-2 definitions. Secondary endpoints included bleeding, time to hemostasis, procedural length and incomplete arteriotomy closure or arterial occlusion by angiography. A Cox proportional hazards model was used to compare all-cause mortality for patients with and without an access site complication. RESULTS: The 512 patients underwent TAVR with MANTA access closure. Median age was 80 (IQR 75-85), 53% was male, median BMI was 26.4 kg/m2 (IQR 23.4-29.7). Access site related major- or minor vascular complication occurred in 20 (4%) and 23 (4%) of patients respectively. Median time to hemostasis was 42 s (IQR 28-98). Post deployment angiogram showed an occlusion in 24 patients (5%), incomplete closure in 60 patients (12%) or both in three patients (1%). Of these 87 patients, 36 (41%) had a vascular complication. Femoral artery diameter (OR 0.70 [0.53-0.93]), low- (OR 3.47 [1.21-10.00]) and high (OR 2.43 [1.16-5.10]) arteriotomies were independent predictors for vascular complications. CONCLUSION: In this contemporary TAVR population, access-site related complications occurred in 8% of patients and were mainly due to percutaneous closure device failure. Small artery diameter and off-target punctures were independent predictors.


Asunto(s)
Estenosis de la Válvula Aórtica , Cateterismo Periférico , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Periférico/efectos adversos , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Técnicas Hemostáticas/efectos adversos , Humanos , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 98(4): 671-677, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33022098

RESUMEN

OBJECTIVES: To validate novel dedicated 3D-QCA based on the software to calculate post PCI vessel-FFR (vFFR) in a consecutive series of patients, to assess the diagnostic accuracy, and to assess inter-observer variability. BACKGROUND: Low post percutaneous coronary intervention (PCI) fractional flow reserve (FFR) predicts future adverse cardiac events. However, FFR assessment requires the insertion of a pressure wire in combination with the use of a hyperemic agent. METHODS: FAST POST study is an observational, retrospective, single-center cohort study. One hundred patients presenting with stable angina or non ST-elevation myocardial infarction, who underwent post PCI FFR assessment using a dedicated microcatheter were included. Two orthogonal angiographic projections were acquired to create a 3D reconstruction of the coronary artery using the CAAS workstation 8.0. vFFR was subsequently calculated using the aortic root pressure. RESULTS: Mean age was 65±12 years and 70% were male. Mean microcatheter based FFR and vFFR were 0.91±0.07 and 0.91±0.06, respectively. A good linear correlation was found between FFR and vFFR (r = 0.88; p <.001). vFFR had a higher accuracy in the identification of patients with FFR values <0.90, AUC 0.98 (95% CI: 0.96-1.00) as compared with 3D-QCA AUC 0.62 (95% CI: 0.94-0.74). Assessment of vFFR had a low inter-observer variability (r = 0.95; p <.001). CONCLUSION: 3D-QCA derived post PCI vFFR correlates well with invasively measured microcatheter based FFR and has a high diagnostic accuracy to detect FFR <0.90 with low inter-observer variability.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Anciano , Estudios de Cohortes , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Programas Informáticos , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 97(6): 1270-1278, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33347739

RESUMEN

OBJECTIVES: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. BACKGROUND: The MANTA is a novel plug-based device for large bore arteriotomy closure. METHODS: We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. RESULTS: Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 ± 6.6 years with a median STS-score of 2.7 [IQR 2.0-4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20-120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. CONCLUSION: In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions.


Asunto(s)
Aneurisma de la Aorta Abdominal , Estenosis de la Válvula Aórtica , Implantación de Prótesis Vascular , Cateterismo Periférico , Procedimientos Endovasculares , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Periférico/efectos adversos , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Hemorragia/etiología , Técnicas Hemostáticas/efectos adversos , Humanos , Sistema de Registros , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 96(3): E204-E212, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31789481

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the very long-term clinical outcome after radioactive stent (RS) implantation and intracoronary ß radiation brachytherapy (IRBT). BACKGROUND: Radioactive stents (RS) and intracoronary ß radiation brachytherapy (IRBT) were introduced to prevent restenosis after percutaneous coronary intervention (PCI). Both techniques were associated with a higher incidence of major adverse cardiac events (MACE) in the short and intermediate-term follow up as compared to conventional PCI. METHODS: One hundred and thirty-three patients received radioactive stents (32 P) and 301 patients were treated with IRBT adjunctive to PCI. These groups were propensity matched to respectively 266 and 602 control patients who were treated with routine PCI during the same inclusion period. Endpoints were all-cause mortality and MACE, defined as all-cause death, any myocardial infarction or any revascularization. RESULTS: Median follow-up duration was 17 years. All-cause mortality rates were similar in all groups. Adjusted hazard ratios for MACE and mortality in the RS cohort were 1.55 (95% CI 1.20-2.00) and 0.92 (95% CI 0.63-1.34), respectively. Adjusted hazard ratios for MACE and all-cause mortality in the IRBT cohort were 1.41 (95% CI 1.18-1.67) and 0.95 (95% CI 0.74-1.21), respectively. The difference in MACE rates was predominantly driven by coronary revascularizations in both groups, with a higher MI rate in the IRBT group as well. CONCLUSIONS: Coronary radiation therapy was associated with early increased MACE rates, but the difference in MACE rates decreased beyond 2 years, resulting in a comparable long-term clinical outcome. Importantly, no excess in mortality was observed.


Asunto(s)
Braquiterapia , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/prevención & control , Intervención Coronaria Percutánea/instrumentación , Stents , Anciano , Braquiterapia/efectos adversos , Braquiterapia/mortalidad , Estudios de Casos y Controles , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/mortalidad , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Países Bajos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 95(2): 226-231, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31033171

RESUMEN

OBJECTIVES: To assess the performance of the commercially available Magmaris sirolimus-eluting bioresorbable scaffold (BRS) with invasive imaging at different time points. BACKGROUND: Coronary BRS with a magnesium backbone have been recently studied as an alternative to polymeric scaffolds, providing enhanced vessel support and a faster resorption rate. We aimed to assess the performance of the commercially available Magmaris sirolimus-eluting BRS at different time points. METHODS: A prospective, single-center, nonrandomized study was performed at the Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands. Six patients with stable de novo coronary artery lesions underwent single-vessel revascularization with the Magmaris sirolimus-eluting BRS. Invasive follow-up including intravascular imaging using optical coherence tomography (OCT) was performed at different time points. RESULTS: At a median of 8 months (range 4-12 months) target lesion failure occurred in one patient. Angiography revealed a late lumen loss of 0.59 ± 0.39 mm, a percentage diameter stenosis of 39.65 ± 15.81%, and a binary restenosis rate of 33.3%. OCT showed a significant reduction in both minimal lumen area (MLA) and scaffold area at the site of the MLA by 43.44 ± 28.62 and 38.20 ± 25.74%, respectively. A fast and heterogeneous scaffold degradation process was found with a significant reduction of patent struts at 4-5 months. CONCLUSIONS: Our findings show that the latest iteration of magnesium BRS suffers from premature dismantling, resulting in a higher than expected decrease in MLA.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Magnesio/química , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Tomografía de Coherencia Óptica , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Diseño de Prótesis , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 95(6): 1085-1091, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-31301161

RESUMEN

OBJECTIVE AND BACKGROUND: The study aim is to provide long-term clinical outcome after percutaneous coronary intervention (PCI) for unprotected left main coronary arteries (ULMCA) stenosis with the first-generation (1st -gen) drug-eluting stents (DES) in comparison to 2nd -gen DES, since this is largely unknown. METHODS: Between May 2002, and December 2014, a consecutive series of 656 all-comer patients underwent a PCI for ULMCA stenosis at the Erasmus Medical Center. A total of 235 patients were treated with 1st -gen DES, while a total of 421 patients were treated with 2nd -gen DES. RESULTS: Overall, the population consisted of 73% males and 58% presented with an acute coronary syndrome. Median follow-up time was 1,361 days (range from 0 to 5,031). At 5 years, the cumulative incidence of major adverse clinical events (the primary composite endpoint of all-cause death, any myocardial infarction or target lesion revascularization; MACE) did not differ between 1st - and 2nd -gen DES (36.8 vs. 38.6%, respectively, Log Rank p = .79, adjusted hazard ratio [HR] = 1.28 [95% confidence interval (CI) 0.94-1.74]). No difference was found in the individual endpoints of all-cause mortality (29.5 vs. 29% respectively, p = .88, adjusted HR = 1.19 [95% CI, 0.84-1.68]), target vessel myocardial infarction (5.0 vs. 8.4%, p = 0.17, adjusted HR = 1.75 [95% CI, 0.78-3.96]) and target lesion revascularization (8.1 vs. 9.8%, p = .94, adjusted HR = 1.16 [95% CI, 0.59-2.29]) between the 1st - and 2nd -gen DES cohorts, respectively. CONCLUSIONS: In this large cohort of consecutive patients treated for ULMCA stenosis, no significant differences were found in the safety and efficacy of 1st versus 2nd -gen DES at 5 years follow-up.


Asunto(s)
Síndrome Coronario Agudo/terapia , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
8.
Age Ageing ; 49(3): 389-394, 2020 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-32091096

RESUMEN

BACKGROUND: delirium is an event leading to negative health outcomes and increased mortality in patients. The aim of this study is to investigate the incidence, determinants and consequences of post-operative delirium (POD) in older patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: The TAVI Care and Cure program is a prospective, observational registry in patients referred for TAVI at Erasmus University Medical Centre. The presence of delirium was evaluated by daily clinical assessment by a geriatrician pre- and up to 3 days post-TAVI. Mortality data were obtained from the Dutch Civil Registry. RESULTS: A total of 543 patients underwent TAVI between January 2014 and December 2017. Overall, the incidence of POD was 14% (75/543 patients) but declined from 18% in 2014 to 7% in 2017 (P = 0.009). Patients who developed POD were older (81.9 ± 5.8 versus 78.6 ± 8.3 years, P < 0.001), had higher prevalence of renal dysfunction and prior stroke (54% versus 40%, P = 0.02; 31% versus 18%, P = 0.01) and were more often frail (32% versus 25%, P = 0.02). From a procedural perspective, general anesthesia (odds ratios (OR), 2.31; 95% CI, 1.40-3.83; P = 0.001), non-transfemoral access (OR, 2.37; 95% CI, 1.20-4.70; P = 0.01) and longer procedural time (OR, 1.01; 95% CI, 1.01-1.02; P < 0.001) were significantly associated with POD. One-year survival rate was 68% among patients who had suffered a POD and was 85% in patients without a POD (hazard ratio's 1.8 (95% CI 1.01-3.10), P = 0.045). CONCLUSION: POD frequently occurs after TAVI and is associated with increased mortality. It might be speculated that patient selection and the minimalistic approach of TAVI may reduce the frequency of delirium.


Asunto(s)
Estenosis de la Válvula Aórtica , Delirio , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Delirio/diagnóstico , Delirio/epidemiología , Humanos , Incidencia , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
9.
Age Ageing ; 49(6): 989-994, 2020 10 23.
Artículo en Inglés | MEDLINE | ID: mdl-32421189

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) brings symptom relief and improvement in health-related quality of life (HRQoL) in the majority of patients treated for symptomatic, severe aortic stenosis. However, there is a substantial group of patients that do not benefit from TAVI. The aim of this study is to investigate the impact of frailty on HRQoL 1 year after TAVI. METHODS: The TAVI Care & Cure Program is an ongoing, prospective, observational study including patients referred for TAVI to our institution. A comprehensive geriatric assessment was performed to evaluate existence of frailty using the Erasmus Frailty Score (EFS). HRQoL was assessed using the EQ-5D-5 L at baseline and 1 year after TAVI. RESULTS: 239 patients underwent TAVI and completed HRQoL assessment 1 year after TAVI. Seventy (29.3%) patients were classified as frail (EFS ≥ 3). In non-frail patients, the EQ-5D-5 L index did not change (0.71(± 0.22) to 0.68(± 0.33) points, P = 0.22); in frail patients, the EQ-5D-5 L index decreased from 0.55(±0.26) to 0.44 points (±0.33) (P = 0.022). Frailty was an independent predictor of deteriorated HRQoL 1 year after TAVI (OR 2.24, 95% CI 1.07-4.70, P = 0.003). In frail patients, the absence of peripheral artery disease (OR 0.17, 95% 0.05-0.50, P = 0.001) and renal dysfunction (OR 0.13, 95% CI 0.04-0.41, P = <0.001) at baseline was associated with improved HRQoL 1 year after TAVI. CONCLUSION: Frailty is associated with deterioration of HRQoL 1 year after TAVI. Notably, HRQoL did improve in frail patients with no peripheral arterial disease or renal impairment at baseline.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Anciano Frágil , Fragilidad/diagnóstico , Humanos , Estudios Prospectivos , Calidad de Vida , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
Am Heart J ; 213: 66-72, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31128504

RESUMEN

BACKGROUND: Post percutaneous coronary intervention (PCI) fractional flow reserve (FFR) is a significant predictor of major adverse cardiac events (MACE). The rationale for low post procedural FFR values often remains elusive based on angiographic findings alone, warranting further assessment using an FFR pullback or additional intravascular imaging. It is currently unknown if additional interventions intended to improve the PCI, decrease MACE rates. STUDY DESIGN: The FFR REACT trial is a prospective, single-center randomized controlled trial in which 290 patients with a post PCI FFR <0.90 will be randomized (1:1) to either standard of care (no additional intervention) or intravascular ultrasound (IVUS)-directed optimization of the FFR (treatment arm). Eligible patients are those treated with angiographically successful PCI for (un)stable angina or non-ST elevation myocardial infarction (MI). Assuming 45% of patients will have a post PCI FFR <0.90, approximately 640 patients undergoing PCI will need to be enrolled. Patients with a post PCI FFR ≥ 0.90 will be enrolled in a prospective registry. The primary end point is defined as a composite of cardiac death, target vessel MI and clinically driven target vessel revascularisation (target vessel failure) at 1 year. Secondary end points will consist of individual components of the primary end point, procedural success, stent thrombosis and correlations on clinical outcome, changes in post PCI Pd/Pa and FFR and IVUS derived dimensions. All patients will be followed for 3 years. CONCLUSION: The FFR-REACT trial is designed to explore the potential benefit of HD-IVUS-guided PCI optimization in patients with a post PCI FFR <0.90 (Dutch trial register: NTR6711).


Asunto(s)
Angina Estable/terapia , Endosonografía/métodos , Reserva del Flujo Fraccional Miocárdico , Infarto del Miocardio sin Elevación del ST/terapia , Intervención Coronaria Percutánea/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Angina Estable/fisiopatología , Humanos , Revascularización Miocárdica , Infarto del Miocardio sin Elevación del ST/fisiopatología , Estudios Prospectivos , Nivel de Atención
11.
Catheter Cardiovasc Interv ; 94(6): 795-805, 2019 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-30901147

RESUMEN

OBJECTIVES: To explore the prevalence of smoking, and its association with clinical and mortality outcome among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Less data exist regarding the effect of baseline smoking status on clinical and mortality outcome among patients undergoing TAVR. METHODS: Consecutive patients who underwent TAVR at two high volume Dutch centers were included. Smoking status was prospectively questioned by a structured interview at admission. Primary endpoint was 1-year all-cause mortality after TAVR. RESULTS: A total of 913 consecutive patients (80.1 ± 7.6 years; logistic EuroSCORE: 16.5 ± 9.9%) who underwent TAVR for severe aortic valve stenosis were included. There were 47% (n = 432) males, and 57% (n = 522) never-smokers, and 35% (n = 317) prior-smokers, and 8% (n = 74) current-smokers. Smokers (i.e., prior-smokers or current-smokers) were younger compared to never-smokers (78.9 ± 7.9 and 76.4 ± 8.0 vs. 81.3 ± 7.1, P < 0.000, respectively). Median follow-up time was 365 (interquartile range [IQR]: 280-365) days. Overall, prior-smoking was not associated with all-cause mortality at 1-year following TAVR (hazard ratio [HR] 0.83, 95% confidence interval [CI] 0.55-1.23). After stratification according to sex, male prior-smokers showed better 1-year survival after TAVR than male never-smokers (12% vs. 20%; P = 0.018, respectively, HR 0.52, 95% CI 0.29-0.89), while this reversed effect was not observed among female prior-smokers versus female never-smokers after TAVR (HR 1.70, 95% CI 0.95-3.05). CONCLUSIONS: Overall, baseline prior-smokers had similar 1-year mortality outcome after TAVR compared with baseline never-smokers. However, there was a reversed association between baseline prior-smoking status and 1-year mortality after TAVR among males, which could partially be explained due to the favorable baseline characteristics.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Fumar Cigarrillos/efectos adversos , Ex-Fumadores , No Fumadores , Fumadores , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Fumar Cigarrillos/mortalidad , Femenino , Humanos , Masculino , Países Bajos , Prevalencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 91(4): 790-797, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28895285

RESUMEN

OBJECTIVES: To evaluate the value of left vertebral artery filter protection in addition to the current filter-based embolic protection technology to achieve complete cerebral protection during TAVR. BACKGROUND: The occurrence of cerebrovascular events after transcatheter aortic valve replacement (TAVR) has fueled concern for its potential application in younger patients with longer life expectancy. Transcatheter cerebral embolic protection (TCEP) devices may limit periprocedural cerebrovascular events by preventing macro and micro-embolization to the brain. Conventional filter-based TCEP devices cover three extracranial contributories to the brain, yet leave the left vertebral artery unprotected. METHODS: Patients underwent TAVR with complete TCEP. A dual-filter system was deployed in the brachiocephalic trunk and left common carotid artery with an additional single filter in the left vertebral artery. After TAVR all filters were retrieved and sent for histopathological evaluation by an experienced pathologist. RESULTS: Eleven patients received a dual-filter system and nine of them received an additional left vertebral filter. In the remaining two patients, the left vertebral filter could not be deployed. No periprocedural strokes occurred. We found debris in all filters, consisting of thrombus, tissue derived debris, and foreign body material. The left vertebral filter contained debris in an equal amount of patients as the Sentinel filters. The size of the captured particles was similar between all filters. CONCLUSIONS: The left vertebral artery is an important entry route for embolic material to the brain during TAVR. Selective filter protection of the left vertebral artery revealed embolic debris in all patients. The clinical value of complete filter-based TCEP during TAVR warrants further research.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Tronco Braquiocefálico , Arteria Carótida Común , Dispositivos de Protección Embólica , Prótesis Valvulares Cardíacas , Embolia Intracraneal/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Arteria Vertebral , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Tronco Braquiocefálico/diagnóstico por imagen , Tronco Braquiocefálico/patología , Arteria Carótida Común/diagnóstico por imagen , Arteria Carótida Común/patología , Angiografía por Tomografía Computarizada , Femenino , Humanos , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/etiología , Embolia Intracraneal/patología , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores Protectores , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Arteria Vertebral/diagnóstico por imagen , Arteria Vertebral/patología
13.
Europace ; 20(12): 1981-1988, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29688322

RESUMEN

Aims: To correlate dynamics in electrical conduction after transcatheter aortic valve implantation (TAVI) with need for permanent pacemaker implantation (PPM) and assess implications for early discharge. Methods and results: Daily electrocardiograms after TAVI were analysed for rhythm and conduction times and were correlated with PPM. Transcatheter aortic valve implantation was performed in 291 consecutive patients with three contemporary transcatheter heart valve designs: Medtronic CoreValve (n = 111), Edwards Sapien XT (n = 29) and Sapien 3 (n = 72), and Boston Lotus (n = 79). We considered two cohorts: (A) Patients with normal baseline conduction; and (B) patients with pre-existent conduction disturbances. Based on QRS dynamics, three patterns were discerned: stable normal QRS duration, transient QRS prolongation, and persistent QRS prolongation. In Cohort B, QRS dynamics did not correlate with PPM. In contrast, in Cohort A, QRS dynamics and PPM appeared highly correlated. Neither patients with stable normal QRS duration (0/47), nor patients with transient QRS prolongation required PPM (0/26). All PPMs occurred in patients with persistent QRS prolongation until discharge (27/85). Persistent QRS prolongation was typically seen with Lotus and CoreValve, whereas stable normal QRS duration was typically seen with Sapien XT and Sapien 3. Conclusion: Three distinct patterns of QRS dynamics can be discerned after TAVI and their predictive probabilities for PPM strongly relate to the baseline conduction status. Patients with normal conduction at baseline and stable QRS duration after TAVI are potentially eligible for early discharge.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Tiempo de Internación , Marcapaso Artificial , Alta del Paciente , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Bases de Datos Factuales , Electrocardiografía , Femenino , Prótesis Valvulares Cardíacas , Hemodinámica , Humanos , Masculino , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 90(1): 58-69, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27896897

RESUMEN

BACKGROUND: Limited data are currently available on the performance of everolimus eluting bioresorbable vascular scaffold (BVS) for treatment of complex coronary lesions representative of daily practice. METHODS: This is a prospective, mono-center, single-arm study, reporting data after BVS implantation in patients presenting with stable, unstable angina, or non-ST segment elevation myocardial infarction caused by de novo stenotic lesions in native coronary arteries. No restrictions were applied to lesion complexity. Procedural results and 12-month clinical outcomes were reported. RESULTS: A total of 180 patients have been evaluated in the present study, with 249 treated coronary lesions. Device Success per lesion was 99.2%. A total of 119 calcified lesions were treated. Comparable results were observed among severe, moderate and noncalcified lesions in term of %diameter stenosis (%DS) (20.3 ± 10.5%, 17.8 ± 7.7%, 16.8 ± 8.6%; P = 0.112) and acute gain (1.36 ± 0.41 mm, 1.48 ± 0.44 mm, 1.56 ± 0.54 mm; P = 0.109). In bifurcations (54 lesions), side-branch ballooning after main vessel treatment was often performed (33.3%) with low rate of side-branch impairment (9.3%). A total of 29 cases with coronary total occlusions were treated. After BVS implantation %DS was not different from other lesion types (17.2 ± 9.4%, vs. 17.7 ± 8.6%; P = 0.780). At one year, all-cause mortality was reported in three cases. The rate of target lesion revascularization and target vessel revascularization was 3.3%. The rate of definite scaffold thrombosis was 2.6%. CONCLUSIONS: The implantation of the everolimus eluting bioresorbable vascular scaffold in an expanded range of coronary lesion types and clinical presentations was observed to be feasible with promising angiographic results and mid-term clinical outcomes. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Implantes Absorbibles , Angina Estable/terapia , Angina Inestable/terapia , Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Estenosis Coronaria/terapia , Everolimus/administración & dosificación , Infarto del Miocardio sin Elevación del ST/terapia , Calcificación Vascular/terapia , Anciano , Angina Estable/diagnóstico por imagen , Angina Estable/mortalidad , Angina Inestable/diagnóstico por imagen , Angina Inestable/mortalidad , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Fármacos Cardiovasculares/efectos adversos , Toma de Decisiones Clínicas , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Everolimus/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Infarto del Miocardio sin Elevación del ST/mortalidad , Selección de Paciente , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/mortalidad
15.
Europace ; 18(suppl 4): iv44-iv52, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28011830

RESUMEN

AIMS: Left bundle branch block (LBBB) is induced in approximately one-third of all transcatheter aortic valve implantation (TAVI) procedures. We investigated electrophysiological remodelling in patients with TAVI-induced LBBB. METHODS AND RESULTS: This retrospective study comprises 107 patients with initially narrow QRS complex of whom 40 did not and 67 did develop persistent LBBB after TAVI. 12-lead electrocardiograms (ECGs) taken before TAVI, within 24 hours ('acute'), and 1-12 months after TAVI ('chronic') were used to reconstruct vectorcardiograms. From these vectorcardiograms, QRS and T-wave area were calculated as comprehensive indices of depolarization and repolarization abnormalities, respectively. TAVI-induced LBBB resulted in significant acute depolarization and repolarization changes while further repolarization changes were observed with longer lasting LBBB. The amount of long-term repolarization changes (remodelling) was highly variable between patients. The change in T-wave area between acute and chronic LBBB ranged from +57% to - 77%. After dividing the LBBB cohort into tertiles based on the change in T-wave area, only baseline QRS area was larger in the tertile with no significant change in T-wave area. During longer lasting LBBB, the spatial vector gradient (SVG) changed orientation towards the direction of the QRS-vector, indicating that later-activated regions developed shorter action potential duration. CONCLUSION: This study in patients with TAVI-induced LBBB shows that repolarization changes develop within months after onset of LBBB, and that these changes are highly variable between individual patients.


Asunto(s)
Potenciales de Acción , Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/fisiopatología , Enfermedad Iatrogénica , Modelos Cardiovasculares , Modelación Específica para el Paciente , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Países Bajos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Vectorcardiografía
16.
J Heart Valve Dis ; 25(3): 289-295, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27989038

RESUMEN

BACKGROUND: The echocardiographic grading of paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) severity is challenging. The study aim was to assess the value of quantitative Doppler echocardiography to monitor PVL severity. METHODS: A total of 100 subjects was enrolled in the study, including 65 consecutive patients who had undergone TAVI with a CoreValve prosthesis and without valvular aortic regurgitation, and 35 normal controls. The PVL volume was calculated using the quantitative Doppler method as the difference of left and right ventricular stroke volume (SV). PVL severity was assessed both visually and quantitatively as the circumferential extent on a short-axis view (SAX). RESULTS: The inter-observer variabilities for SVs in TAVI patients were disappointing: 14 ± 11% for the left ventricular SV and 18 ± 14% for right ventricular SV. The correlation (r2) between the averaged regurgitant PVL volume and circumferential SAX extent of PVL was 0.02 (p = NS). The relationship between PVL volumes and categories, defined quantitatively by the circumferential SAX extent of PVL and qualitatively by visual assessment of severity of PVL were poor. The results improved when only patients with optimal quality images were included but were still statistically non-significant. CONCLUSIONS: The relationship between calculated PVL volume in TAVI patients and other estimates of PVL severity was poor, most likely due to intrinsic errors made in the quantitative Doppler method. Therefore, one should be prudent to include the quantitative Doppler method in TAVI patients in clinical trials and clinical decision-making, in particular in patients with reduced image quality.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Ecocardiografía Doppler , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Adulto , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estudios de Casos y Controles , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reproducibilidad de los Resultados , Factores de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Función Ventricular Izquierda , Función Ventricular Derecha
17.
Cardiovasc Ultrasound ; 14(1): 37, 2016 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-27600600

RESUMEN

To make assessment of paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) more uniform the second Valve Academic Research Consortium (VARC) recently updated the echocardiographic criteria for mild, moderate and severe PVL. In the VARC recommendation the assessment of the circumferential extent of PVL in the short-axis view is considered critical. In this paper we will discuss our observational data on the limitations and difficulties of this particular view, that may potentially result in overestimation or underestimation of PVL severity.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Humanos , Diseño de Prótesis , Falla de Prótesis , Factores de Riesgo
18.
Catheter Cardiovasc Interv ; 86(5): 875-85, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26032764

RESUMEN

OBJECTIVES: We sought to evaluate the impact of mixed aortic stenosis (MAS) on postprocedural aortic regurgitation (PPAR) and clinical outcomes after transcatheter aortic valve implantation (TAVI). BACKGROUND: The impact of MAS of TAVI outcomes is unknown. METHODS AND RESULTS: Data from a multicenter registry were retrospectively analysed. Outcomes were compared between patients with pure aortic stenosis (PAS; associated AR<1+/3+) and MAS (associated AR≥1+/3+). Study objectives were PPAR incidence and short- and long-term mortality. Overall, 1,062 patients were included: 419 (39.4%) with MAS and 643 (60.5%) with PAS. At 30 days, there were no differences in mortality, however, a higher incidence of major bleeding (22.7% vs. 16.8%; P=0.016), PPAR≥1+/3+ (42.6% vs. 26.5%; P<0.001) and lower device success (89.3% vs. 93.3%; P=0.019) was observed in patients with MAS. Of note, MAS was an independent predictor of PPAR≥1+/3+ at multivariable analysis (OR: 2.882; CI: 1.851-4.488; P<0.001). At 2 years of follow-up, no survival differences were present between MAS and PAS groups. Similarly, following stratification for PPAR≥1+/3+, MAS had no protective effect on survival as compared with PAS. CONCLUSIONS: MAS was associated with lower device success and higher PPAR incidence. However, despite these findings, it had no influence on long-term postoperative outcomes.


Asunto(s)
Insuficiencia de la Válvula Aórtica/terapia , Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Distribución de Chi-Cuadrado , Europa (Continente) , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Oportunidad Relativa , Modelos de Riesgos Proporcionales , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía
19.
Catheter Cardiovasc Interv ; 85(5): E144-52, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25504891

RESUMEN

OBJECTIVES: The aim of the study was to investigate trends over time in the occurrence of left bundle branch block (LBBB) and permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) with the Medtronic CoreValve System (MCS) and Edwards SAPIEN Valve (ESV). BACKGROUND: TAVI-induced conduction abnormalities (TAVI-CAs) such as LBBB and the need for PPI are frequent postoperative complication. New techniques, procedural refinements, and increased awareness are focused on the reduction of these abnormalities. METHODS: Electrocardiograms of 549 patients without preprocedural LBBB and/or pacemaker were assessed to determine the frequency and nature of TAVI-CAs. To study the effect of experience, patients were subdivided per center into tertiles based on the number of procedures. Univariate and multivariate logistic regression was used to study predictors of TAVI-induced LBBB (TAVI-LBBB) and PPI. RESULTS: TAVI-LBBB occurred in 185 patients (33.7%) and significantly decreased over time, from 42.6% to 27.3% (P=0.006). This effect was only significant after implantation of the MCS (59.6% vs. 46.5% vs. 31.1%, P=0.001, ESV: 22.6% vs. 13.1% vs. 24.8%, P=0.11). Between tertiles there was no difference in the frequency of PPI after TAVI (n=73, 13.1% vs. 14.8% vs. 12%, P=0.74). Multivariate analysis revealed that, independent from valve type, depth of implantation was the only significant predictor of TAVI-LBBB (OR [95% C.I.]: 1.16 [1.10-1.24], P<0.001). In case of PPI pre-existing RBBB (OR [95% C.I.]: 7.22 [3.28-15.88], P<0.001) was the only significant predictor. CONCLUSIONS: Over time the frequency of LBBB after TAVI decreased significantly, especially in patients undergoing TAVI with the MCS. Experience and the subsequent reduction in depth of implantation seem responsible for this reduction. Contrary to TAVI-LBBB, the incidence of PPI remained unchanged over time and was not affected by experience. Although experience has led to a decrease in new CAs after TAVI, elucidation of pathophysiologic mechanisms underlying these CAs and subsequent changes in patient stratification, valve design and the procedure are needed to further reduce this complication.


Asunto(s)
Bloqueo de Rama/epidemiología , Marcapaso Artificial , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Electrocardiografía , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Incidencia , Masculino , Países Bajos/epidemiología , Quebec/epidemiología , Estudios Retrospectivos
20.
Cardiovasc Ultrasound ; 13: 29, 2015 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-26113031

RESUMEN

BACKGROUND: Symptoms in the elderly patients with severe aortic stenosis (AS) and co-morbidities seem to lack in specificity. Therefore, objective parameters for increased left ventricular(LV) filling pressures are needed. The aim of this study was to investigate the correlation between the septal, lateral and average E/e' ratio and the value of the N-terminal pro-hormone of brain natriuretic peptide (NT-proBNP). METHODS: Two-hundred-fifty consecutive symptomatic patients (mean age 80 ± 8 years, 52% men) with severe AS underwent transthoracic echocardiography and NT-proBNP measurement. RESULTS: In the overall population the septal E/e' (r = 0,459, r(2) = 0,21, P <0,0001), lateral E/e' (r = 0,322, r(2) = 0,10, P <0,0001), and the average E/e' (r = 0,432, r(2) = 0,18, P <0,0001) were all significantly correlated to NT-proBNP. After the exclusion of patients with confounders (more than mild aortic or mitral regurgitation, severe renal dysfunction, obesity or severe COPD) the septal E/e' (r = 0,584, r(2) = 0,34, P <0,0001), lateral E/e' (r = 0,377, r(2) = 0,14, P <0,0001), and the average E/e' (r = 0,487, r(2) = 0,24, P <0,0001) were all significantly better correlated to NT-proBNP. In obese patients no significant correlations were seen. Previous bypass surgery did not alter the correlations. CONCLUSIONS: In elderly patients with severe symptomatic AS there is a significant correlation between the E/e' ratio and NT-proBNP, in particular after exclusion of confounders. The correlation was best for the septal E/e' ratio and was preserved in patients with a history of bypass surgery.


Asunto(s)
Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Volumen Sistólico , Disfunción Ventricular Izquierda/sangre , Disfunción Ventricular Izquierda/diagnóstico por imagen , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Biomarcadores/sangre , Ecocardiografía/métodos , Femenino , Evaluación Geriátrica/métodos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto , Disfunción Ventricular Izquierda/etiología