Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Biomed Res Int ; 2022: 2185111, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35757469

RESUMEN

This study is aimed at evaluating the profile of inflammatory markers and components of redox regulation in untrained women after 10 weeks of resistance training using equalized protocols but different muscle action duration (MAD). Twenty-two women underwent progressive resistance training exercising the knee extensor muscles for 10 weeks-3x/week, with 3-5 sets of 6 repetitions at 50% of the 1 repetition maximum strength test (1RM), with a rest of 180 s between the series, following the training protocol (i) 5 s of concentric muscle action for 1 s of eccentric muscle action (5C-1E) and (ii) 1 s of concentric muscle action for 5 s of eccentric muscle action (1C-5E). Quadriceps muscle hypertrophy maximum strength (1RM) and redox regulation/muscle damage/inflammatory markers (CAT, SOD, TBARS, FRAP, CH, LDH, CXCL8, and CCL2) were evaluated. Plasma markers were evaluated before and 30 minutes after the first and last training sessions. A similar gain in hypertrophy and maximum strength was observed in both groups. However, in the 5C-1E, a significant major effect was observed for SOD (F 1.19 = 10.480, p = 0.004) and a significant major time effect, with a reduction in the last training session, was observed for CXCL8 (F 1.37 = 27.440, p < 0.001). In conclusion, similar protocols of resistance training, with different MAD, produced similar inflammatory and adaptive responses to strength training. As the training load is progressive, the maintenance of this inflammatory and redox regulation profile suggests an adaptive response to the proposed strength training.


Asunto(s)
Entrenamiento de Fuerza , Adaptación Fisiológica , Femenino , Humanos , Hipertrofia , Fuerza Muscular/fisiología , Músculo Esquelético/fisiología , Músculo Cuádriceps/fisiología , Entrenamiento de Fuerza/métodos , Superóxido Dismutasa
2.
J Hum Kinet ; 73: 33-44, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32774535

RESUMEN

This study compared the electromyographic response, the blood lactate concentration (BLC), and the maximum number of repetitions (MNR) between protocols of different concentric/eccentric duration taken to muscle failure. This comparison may help to understand how different concentric/eccentric duration may influence performance and the central and metabolic responses in trained men. Seventeen strength-trained men performed two protocols in a counterbalanced design. Three sets of the Smith bench press exercise were performed to failure at 60% of the one-repetition maximum (1RM) using each protocol (4-s concentric/2-s eccentric [4 s: 2 s]; and 2-s concentric/4-s eccentric [2 s: 4 s]). The normalized root mean square (EMGRMS) and the mean frequency (EMGMF) of the electromyographic signals for the pectoralis major and the triceps brachii were compared in the first, middle, and last repetitions. The BLC was assessed at rest, during and after the test sessions. To compare the EMG and BLC, a 3-way ANOVA with repeated measures with a post hoc Tukey's test was used. To compare the MNR performed across the sets, an ANOVA-type rank test with the Dunn's post hoc test was used. The ANOVA indicated a greater EMGRMS for Protocol 4 s: 2 s in the pectoralis major and a lower EMGMF for Protocol 4 s: 2 s in the triceps brachii at the middle and last repetitions. Both protocols increased the EMGRMS and decreased the EMGMF across repetitions. Despite the results show different levels of activation and neuromuscular fatigue between protocols, the BLC and the MNR were similar.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA