1.
Knee Surg Sports Traumatol Arthrosc ; 22(2): 448-55, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23370985

RESUMEN

PURPOSE: Operative treatment for middle-third clavicle fractures has been increasing as recent data has demonstrated growing patient dissatisfaction and functional deficits after non-operative management. A controlled biomechanical comparison of the characteristics of locked intramedullary (IM) fixation versus superior pre-contoured plating for fracture repair and hardware removal is warranted. Therefore, the purpose of the present study was to investigate potential differences between these devices in a biomechanical model. METHODS: Thirty fourth-generation composite clavicles were randomized to one of five groups with 6 specimens each and tested in a random order. The groups tested were intact, repair with plate, repair with IM device, plate removal, and IM device removal. The lateral end of the clavicles was loaded to failure at a rate of 60 mm/min in a cantilever bending setup. Failure mechanism, energy (J), and torque (Nm) at the site of failure were recorded. RESULTS: Failure torque of the intact clavicle (mean ± standard deviation) was 36.5 ± 7.3 Nm. Failure torques of the IM repair (21.5 ± 9.0 Nm) and plate repair (18.2 ± 1.6 Nm) were not significantly different (n.s.) but were significantly less than the intact group (P < 0.05). Failure torque following IM device removal (30.2 ± 6.5 Nm) was significantly greater than plate removal (12.9 ± 2.0 Nm) (P < 0.05). No significant differences were observed between the intact and IM device removal groups (n.s.). CONCLUSION: The results of the current study demonstrate that IM and plate devices provide similar repair strength for middle-third clavicle fractures. However, testing of the hardware removal groups found the IM device removal group to be significantly stronger than the plate removal group.


Asunto(s)
Placas Óseas , Tornillos Óseos , Clavícula/lesiones , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Fijadores Internos , Fenómenos Biomecánicos , Clavícula/cirugía , Remoción de Dispositivos , Fijación Interna de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Humanos , Torque
2.
Am J Sports Med ; 41(2): 416-22, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23263298

RESUMEN

BACKGROUND: Optimization of anterior cruciate ligament (ACL) fixation is desired to improve graft healing. New soft tissue cortical suspension devices for femoral tunnel fixation should be biomechanically evaluated. HYPOTHESIS: All femoral fixation devices would prevent a clinically significant amount of displacement and support loads significantly larger than in situ forces experienced by the ACL during early rehabilitation. STUDY DESIGN: Controlled laboratory study. METHODS: Four cortical soft tissue ACL graft suspension devices were tested under cyclic and pull-to-failure loading conditions in both an isolated device-only setup and as a complete bone-device-tendon construct in porcine femurs using a tensile testing machine. RESULTS: There were significant differences in the ultimate failure loads among the devices. The highest ultimate failure loads when tested as a construct were observed for the XO Button (1748 N), followed by the Endobutton CL (1456 N), ToggleLoc with ZipLoop (1334 N), and TightRope RT (859 N). Cyclic displacement after 1000 cycles during isolated device testing was less than 1 mm for all devices. Cyclic displacements after 1000 cycles in the porcine construct were 1.88 mm, 2.74 mm, 3.34 mm, and 1.82 mm for the Endobutton, TightRope, ToggleLoc, and XO Button, respectively; all were significantly different from each other except when the Endobutton was compared with the XO Button. The ToggleLoc exceeded the 3.0-mm displacement threshold defined as a clinical failure. The most displacement occurred during the first cycle, especially for the adjustable-length loop devices. Stiffness reapproximated the native ACL stiffness for all constructs. CONCLUSION: The Endobutton, TightRope, and XO Button have the necessary biomechanical properties with regard to ultimate failure strength, displacement, and stiffness for initial fixation of soft tissue grafts in the femoral tunnel for ACL reconstruction. The ToggleLoc had sufficient ultimate failure strength but crossed our 3.0-mm clinical failure threshold for cyclic displacement. Although this study was not designed to compare fixed and adjustable-length loop devices, it was noted that both fixed-loop devices allowed less cyclic displacement and initial displacement. CLINICAL RELEVANCE: Adjustable-length loop devices may need to be retensioned after cycling the knee and fixing the tibial side to account for the increased initial displacement seen with these devices.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/instrumentación , Ligamento Cruzado Anterior/cirugía , Fémur/cirugía , Fijadores Internos , Articulación de la Rodilla/cirugía , Animales , Ligamento Cruzado Anterior/fisiopatología , Fenómenos Biomecánicos , Modelos Animales de Enfermedad , Articulación de la Rodilla/fisiopatología , Porcinos