1.
J Endovasc Ther ; : 15266028241227392, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38288587

RESUMEN

INTRODUCTION: The aim of this study is to share preliminary experiences and outcomes with a novel custom-made fenestrated TREO® Abdominal Stent-Graft System to treat juxtarenal and pararenal abdominal aortic aneurysms (AAAs). METHODS: Juxtarenal and pararenal AAA patients treated with the custom-made fenestrated TREO® Abdominal Stent-Graft System were included from 4 high-volume European academic medical centers from June 2021 to September 2023. Technical success and 30-day/in-hospital mortality and complications were analyzed. Technical success was defined as successful endovascular implantation of the stent graft with preservation of antegrade flow to the target vessels, and absence of type 1 or 2 endoleak (EL) at the first postoperative computed tomography angiography (CTA). RESULTS: Forty-two consecutive patients were included. The majority of the devices were constructed with 2 (N=4; 9.5%), 3 (N=9; 21.4%), or 4 (N=27; 64%) fenestrations. In 1 case, the device was constructed with a single fenestration (2.4%) and 1 device contained 5 fenestrations (2.4%); 17% had previous AAA repair. Target vessel cannulation with placement of a bridging stent was successful in all but 1 vessel (99, 3%). One aneurysm-related death occurred in the direct postoperative period and 2 limb occlusions necessitated reintervention during admission. In the median follow-up period of 101 (2-620) days, 3 more patients died due to non-aneurysm-related causes. Technical success was achieved in 90% of the cases. Nineteen ELs were seen on the first postoperative CT scan: 1 type 1b EL (N=1; 2%), 15 type 2 ELs (N=15; 36%), and 3 type 3 ELs (N=3%). Eleven patients received more than 1 CT scan during a median follow-up of 361 days (82-620): 3 type 2 ELs resolved and 1 type 3 EL was treated in this period. In the follow-up, 1 patient had a coagulation disorder that caused occlusions of the branches. CONCLUSION: The results of the first experiences using the custom-made fenestrated TREO® Abdominal Stent-Graft System in Europe are promising. There was a low short-term mortality and morbidity rate in these patients of which 17% had previous AAA repair. Mid-term and long-term follow-up data are needed to evaluate endograft durability and performance. CLINICAL IMPACT: This study shows the first experiences and short-term results of a novel low-profile custom-made device: the custom-made fenestrated TREO® Abdominal Stent-Graft System. Showing these results and experiences can help the physicians in clinical decision-making for their patients.

2.
Eur J Vasc Endovasc Surg ; 53(2): 199-205, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28027889

RESUMEN

OBJECTIVES: Reference values of aortic deformation during the cardiac cycle can be valuable for the pre-operative planning of thoracic endovascular aortic repair (TEVAR) and for facilitating computational fluid dynamics. This study aimed to quantify normal aortic extensibility (longitudinal extension) and distensibility (radial expansion), as well as pulsatile strain, in a group of 10 (>60 years) individuals with abdominal or thoracic aortic aneurysms. METHODS: ECG gated CT images of the thoracic aorta were reconstructed into virtual 3D models of aortic geometry. The centre lumen line length of the thoracic aorta and three longitudinal segments, and the aortic diameter and luminal areas of four radial intersections were extracted with a dedicated software script to calculate extensibility, longitudinal strain, distensibility, and circumferential area strain. RESULTS: Mean extensibility and longitudinal strain of the entire thoracic aorta were 3.5 [1.3-6.8] × 10-3 N-1, and 2.7 [1.0-4.5]%, respectively. Extensibility and longitudinal strain were most pronounced in the ascending aorta (20.6 [5.7-36.2] × 10-3 N-1 and 15.9 [6.6-31.9]%) and smallest in the descending aorta (4.4 [1.6-12.3] × 10-3 N-1 and 2.2 [0.7-4.7]%). Mean distensibility and circumferential area strain were most pronounced at the sinotubular junction (1.7 [0.5-2.9] × 10-3 mmHg-1 and 11.3 [3.3-18.5]%, respectively). Distensibility varied between 0.9 [0.3-2.5] × 10-3 mmHg-1 and 1.2 [0.3-3.3] × 10-3 mmHg-1 at the intersections in the aortic arch and descending aorta. CONCLUSIONS: Pulsatile deformations in both longitudinal and circumferential directions are considerable throughout the thoracic aorta. These findings may have implications for pre-operative TEVAR planning and highlight the need for devices that can mimic the significant aortic longitudinal and circumferential strains.


Asunto(s)
Aorta Torácica/fisiopatología , Aneurisma de la Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Torácica/fisiopatología , Modelos Cardiovasculares , Flujo Pulsátil , Anciano , Anciano de 80 o más Años , Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aortografía/métodos , Fenómenos Biomecánicos , Técnicas de Imagen Sincronizada Cardíacas , Angiografía por Tomografía Computarizada , Simulación por Computador , Electrocardiografía , Femenino , Humanos , Masculino , Tomografía Computarizada Multidetector , Flujo Sanguíneo Regional , Estudios Retrospectivos , Estrés Mecánico
3.
Eur J Vasc Endovasc Surg ; 50(3): 331-40, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26036808

RESUMEN

OBJECTIVES/BACKGROUND: To examine the additional diagnostic value of magnetic resonance imaging (MRI) after administration of a weak albumin binding contrast agent in post-endovascular aneurysm repair (EVAR) patients with aneurysm growth with no or uncertain endoleak after computed tomography angiography (CTA). METHODS: This was a prospective diagnostic cross sectional study carried out between April 2011 and August 2013. MRI was performed in all patients with aneurysm growth≥5 mm after EVAR implantation and no or uncertain endoleak on CTA, or the inability, on CTA, to identify the source of a visible endoleak. All MRI scans were performed on a 1.5 T clinical MRI scanner after administration of a weak albumin binding contrast agent. The presence of endoleaks was assessed by visually comparing pre- and post-contrast T1-weighted images with fat suppression. Post-contrast images were acquired 5 and 15 minutes after contrast administration. RESULTS: Twenty-nine patients (26 men; 90%) with a median age of 74 years (interquartile range [IQR] 67-76) were included. The median interval between EVAR and MRI was 39 months (IQR 20-50). The median increase in maximum aneurysm diameter during total follow up after EVAR was 11 mm (IQR 6-17). At CTA, 16 patients (55%) had no detectable endoleak, five patients (17%) had suspected but uncertain endoleak, and eight patients had a definite endoleak (28%). On the post-contrast MRI images, endoleak was observed in 24 patients (83%). In all patients with uncertain endoleak on CTA, endoleak was detected with MRI. For type II endoleaks, feeding vessels were detected in 22/23 patients (96%) and these were all, except one, lumbar arteries. CONCLUSION: In patients with enlarging aneurysms of unknown origin after EVAR, MRI with a weak albumin binding contrast agent has additional value for both the detection and determination of the origin of the endoleak.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Medios de Contraste , Endofuga/diagnóstico , Procedimientos Endovasculares/efectos adversos , Angiografía por Resonancia Magnética , Meglumina/análogos & derivados , Compuestos Organometálicos , Albúmina Sérica/metabolismo , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico , Aortografía/métodos , Medios de Contraste/metabolismo , Estudios Transversales , Endofuga/sangre , Endofuga/etiología , Endofuga/terapia , Femenino , Humanos , Masculino , Meglumina/metabolismo , Compuestos Organometálicos/metabolismo , Valor Predictivo de las Pruebas , Estudios Prospectivos , Unión Proteica , Albúmina Sérica Humana , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
4.
Eur J Vasc Endovasc Surg ; 49(1): 19-27, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25453236

RESUMEN

OBJECTIVE: To determine if mid-term outcome following endovascular aneurysm repair (EVAR) with the Endurant Stent Graft (Medtronic, Santa Rosa, CA, USA) is influenced by severe proximal neck angulation. METHODS: A retrospective case-control study was performed using data from a prospective multicenter database. All measurements were obtained using dedicated reconstruction software and center-lumen line reconstruction. Patients with neck length >15 mm, infrarenal angle ß > 75°, and/or suprarenal angle α > 60°, or neck length >10 mm with ß > 60°, and/or α > 45° were compared with a matched control group. Primary endpoint was primary clinical success. Secondary endpoints were freedom from rupture, type 1A endoleak, stent fractures, freedom from neck-related reinterventions, and aneurysm-related adverse events. Morphological neck variation over time was also assessed. RESULTS: Forty-five patients were included in the study group and were compared with a matched control group with 65 patients. Median follow-up time was 49.5 months (range 30.5-58.4). The 4-year primary clinical success estimates were 83% and 80% for the angulated and nonangulated groups (p = .42). Proximal neck angulation did not affect primary clinical success in a multivariate model (hazard ratio 1.56, 95% confidence interval 0.55-4.41).Groups did not differ significantly in regard to freedom from rupture (p =.79), freedom from type 1A endoleak (p = .79), freedom from neck-related adverse events (p = .68), and neck-related reinterventions (p = .68). Neck angle reduction was more pronounced in patients with severe proximal neck angulation (mean deltaα -15.6°, mean deltaß -30.6°) than in the control group (mean deltaα -0.39°, mean deltaß -5.9°) (p < .001). CONCLUSION: Mid-term outcomes following EVAR with the Endurant Stent Graft were not influenced by severe proximal neck angulation in our population. Despite the conformability of the device, moderate aortic neck remodeling was identified in the group of patients with angulated neck anatomy on the first computed tomography scan after implantation with no important further remodeling afterwards. No device integrity failures were encountered.


Asunto(s)
Aorta Abdominal/patología , Aneurisma de la Aorta Abdominal/patología , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Rotura de la Aorta/epidemiología , Aortografía , Prótesis Vascular , Estudios de Casos y Controles , Endofuga/epidemiología , Procedimientos Endovasculares/estadística & datos numéricos , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Stents , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
5.
Eur J Vasc Endovasc Surg ; 48(1): 53-9, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24581938

RESUMEN

OBJECTIVE: Direct additional therapy is advised for type-Ia endoleaks detected on completion angiography after endovascular aneurysm repair (EVAR). Additional intraoperative endovascular procedures are, however, often challenging or not possible, and direct open conversion is unattractive. The results of a selective, conservative strategy for patients with primary type-Ia endoleak has been analysed. METHODS: This was a retrospective, single-centre study (UMC, Utrecht, NL). From 2004 to 2008, all patients with a primary type-Ia endoleak and suitable anatomy for EVAR, stentgraft oversizing ≥15%, and optimal deployment were included. Complications during follow-up were studied and all sequential CTA scans were reviewed. These were compared with the remaining patients, treated during the same period. RESULTS: Fifteen patients were included (14 male, median age 77, range 67-85) with a median aneurysm diameter of 60 mm (48-80), an aneurysm neck diameter of 26 mm (21-32), a neck length of 29 mm (11-39), and infrarenal angulation of 49° (31-90). One patient suffered rupture 2 days after EVAR - leading to the only AAA-related death. Eight of the 15 type-Ia endoleaks disappeared spontaneously on the first postoperative CTA, obtained within 1 week of EVAR. On the second postoperative CTA, obtained a median of 5 months (1-12) after EVAR, all remaining endoleaks had sealed. One recurrence occurred at 4.85 years. During a median follow-up of 3.3 years, there were five secondary interventions. Compared with controls, there were more secondary (or recurrent) type-1a endoleaks (13% vs. 4%), endograft migrations (13% vs. 3%), sac growths (33% vs. 16%), and secondary interventions (33% vs. 23%). None of these differences however, were statistically significant. CONCLUSIONS: All but one of the primary type-Ia endoleaks sealed spontaneously. Until sealing, the risk of rupture persisted, but subsequently only one recurrence of type-Ia endoleak was seen. In selected patients, a conservative approach for primary type-Ia endoleaks may be justified.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Endofuga/diagnóstico , Endofuga/diagnóstico por imagen , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Masculino , Tomografía Computarizada Multidetector , Países Bajos , Diseño de Prótesis , Recurrencia , Remisión Espontánea , Retratamiento , Estudios Retrospectivos , Stents , Factores de Tiempo
6.
Eur J Vasc Endovasc Surg ; 45(4): 340-50, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23403221

RESUMEN

OBJECTIVES: The purpose of this systematic review was to examine whether magnetic resonance imaging (MRI) or computed tomography angiography (CTA) is more sensitive for the detection of endoleaks in patients with abdominal aortic aneurysm (AAA) after EVAR. DESIGN: Systematic review. MATERIALS AND METHODS: A systematic electronic search was performed. Articles were included when post-EVAR patients were evaluated by both MRI as index test and CTA as comparison. Methodological quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool. Primary outcome was the proportion of patients in whom MRI detected additional endoleaks, which were not seen with CTA. RESULTS: Eleven articles were included. The overall methodological quality of the articles was good. In total, 369 patients with 562 MRI and 562 CTA examinations were included. A total of 146 endoleaks were detected by CTA; MRI detected all but two of these endoleaks. With MRI 132 additional endoleaks were found. CONCLUSIONS: MRI is more sensitive compared to CTA for the detection of post-EVAR endoleaks, especially for the detection of type II endoleaks. MRI should be considered in patients with continued AAA growth and negative or uncertain findings at CTA.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/diagnóstico , Procedimientos Endovasculares/efectos adversos , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/patología , Humanos , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Resultado del Tratamiento
7.
J Clin Med ; 12(13)2023 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-37445507

RESUMEN

The aorta is in constant motion due to the combination of cyclic loading and unloading with its mechanical coupling to the contractile left ventricle (LV) myocardium. This aortic root motion has been proposed as a marker for aortic disease progression. Aortic root motion extraction techniques have been mostly based on 2D image analysis and have thus lacked a rigorous description of the different components of aortic root motion (e.g., axial versus in-plane). In this study, we utilized a novel technique termed vascular deformation mapping (VDM(D)) to extract 3D aortic root motion from dynamic computed tomography angiography images. Aortic root displacement (axial and in-plane), area ratio and distensibility, axial tilt, aortic rotation, and LV/Ao angles were extracted and compared for four different subject groups: non-aneurysmal, TAA, Marfan, and repair. The repair group showed smaller aortic root displacement, aortic rotation, and distensibility than the other groups. The repair group was also the only group that showed a larger relative in-plane displacement than relative axial displacement. The Marfan group showed the largest heterogeneity in aortic root displacement, distensibility, and age. The non-aneurysmal group showed a negative correlation between age and distensibility, consistent with previous studies. Our results revealed a strong positive correlation between LV/Ao angle and relative axial displacement and a strong negative correlation between LV/Ao angle and relative in-plane displacement. VDM(D)-derived 3D aortic root motion can be used in future studies to define improved boundary conditions for aortic wall stress analysis.

8.
Eur J Vasc Endovasc Surg ; 42(4): 489-97, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21741278

RESUMEN

OBJECTIVES: The Endurant Stent Graft System (Medtronic Vascular, Santa Rosa, CA) is specifically designed to treat patients with abdominal aortic aneurysm, including those with difficult anatomies. This is the 1-year report of a prospective, non-randomised, open-label trial at 10 European centres. METHODS: Between November 2007 and August 2008, 80 patients were enrolled for elective endovascular aneurysm repair (EVAR) with the Endurant; 71 with moderate (≤ 60°) and nine with high (60-75°) infrarenal aortic neck angulation. Safety and stent-graft performance were assessed throughout a 1-year follow-up period. RESULTS: The device was successfully delivered and deployed in all cases. All-cause mortality was 5% (4/80), with one possibly device-related death. Serious adverse events were comparable between the high and moderate angulation groups. There were no device migrations, stent fractures, aortic ruptures or conversions to open repair. Maximal aneurysm diameter decreased >5 mm in 42.7% of cases. A total of 28 endoleaks were observed (26 type II, two undetermined). Three secondary endovascular procedures were performed for outflow vessel stenosis, graft limb occlusion and iliac extension, resulting in a secondary patency rate of 100%. No re-interventions were required in the high angulation group. CONCLUSIONS: The Endurant Stent Graft was successfully delivered and deployed in all cases and performed safely and effectively in all patients, including those with unfavourable proximal neck anatomy.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Stents , Anciano , Anciano de 80 o más Años , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Reoperación , Stents/efectos adversos
9.
Eur J Vasc Endovasc Surg ; 41(2): 193-200, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21145268

RESUMEN

OBJECTIVE: Angulation of the proximal aneurysm neck has been associated with adverse outcome after EVAR. We aim to investigate the influence of angulation on early results when using the Endurant Stentgraft System. METHODS: A retrospective analysis of a prospective multicentre database identified 45 elective patients treated with the Endurant stentgraft with severe angulation of the proximal neck, which were compared to a control group without significant angulation. Endpoints were early technical and clinical success, deployment accuracy and differences in operative details. RESULTS: Mean age was 74 with 86.4% males. Mean infrarenal angle (ß) was 80.8° ± 16 and mean suprarenal angle (α) was 51.4° ± 21. Patients in the angulated group had larger aneurysms (mean 309 cc vs. 187 cc), shorter necks (mean 27 mm ± 14 vs. 32.6 mm ± 13) and 74% (vs. 56%) were ASA III/IV. Technical success was 100%, with one patient requiring an unplanned proximal extension. No differences were found regarding early type-I endoleaks (0% vs. 0%), major postoperative complications (6.7% vs. 6.2%; p = 0.77) or early survival (97.8% vs. 96.9%, p = 0.79). Distance from lowest renal artery to prosthesis was 2.4 mm ± 2.7 vs. 2.3 mm ± 4.8, p = 0.9. Operative details were equivalent for both groups. CONCLUSIONS: Treatment with the Endurant stentgraft is technically feasible and safe, with satisfactory results in angulated and non-angulated anatomies alike. No sealing length was lost in extremely angulated cases, confirming the device's high conformability. Mid- and long-term data are awaited to verify durability, but early results are promising and challenge current opinion concerning neck angulation.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Distribución de Chi-Cuadrado , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Países Bajos , Selección de Paciente , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
10.
Eur Spine J ; 20(9): 1474-9, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21340711

RESUMEN

Diffuse idiopathic skeletal hyperostosis (DISH) is a systemic condition leading to ossification of spinal ligaments and has been shown to behave similarly to ankylosing spondylitis (AS) often leading to unstable hyperextension fractures. Currently, no quantitative data are available on the spatial relationship between the bridging anterolateral ossification mass (ALOM) and the vertebral body/intervertebral disc to explain the propensity in DISH to fracture through the vertebral body instead of through the intervertebral disc as more often seen in AS. Furthermore, no reasonable explanation is available for the typical flowing wax morphology observed in DISH. In the current study, a quantitative analysis of computed tomography (CT) data from human cadaveric specimens with DISH was performed to better understand the newly formed osseous structures and fracture biomechanics. Additionally, the results were verified using computed tomography angiography data from ten patients with DISH and ten controls. Transverse CT images were analyzed to obtain ALOM area and centroid angle relative to the anteroposterior axis; intervertebral disc and adjacent cranial and caudal levels. The ALOM area at the mid-vertebral body level averaged 57.9 ± 50.0 mm(2); at the mid-intervertebral disc space level it averaged 246.4 ± 95.9 mm(2). The mean ALOM area at the adjacent level caudal to the mid-vertebral body level was 169.6 ± 81.3 mm(2); at the adjacent cranial level, it was 161.7 ± 78.2 mm(2). The main finding was the significant difference between mean ALOM area at the mid-vertebral body level and other three levels (p < 0.0001). The subsequent verification study showed the presence of vertebral segmental arteries at the mid-vertebral body level in nearly all images irrespective of the presence of DISH. A larger area of ALOM seemed associated with increased counter-clockwise rotation (away from the aorta) of the centroid relative to the anteroposterior axis. The results from the present study suggest a predisposition for fractures through the vertebral body and a role for the arterial system in the inhibition of soft tissue ossification.


Asunto(s)
Hiperostosis Esquelética Difusa Idiopática/diagnóstico por imagen , Vértebras Torácicas/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Radiografía , Espondilitis Anquilosante/diagnóstico por imagen
12.
Eur J Vasc Endovasc Surg ; 40(3): 326-31, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20561803

RESUMEN

PURPOSE: The proximal abdominal aortic aneurysm (AAA) neck expands significantly during the cardiac cycle, both before and after endovascular aneurysm repair (EVAR). Clinical consequences of this pulsatility were anticipated but have never been reported. This study investigated whether there is a relation between stent graft migration and preoperatively measured pulsatility of the proximal aneurysm neck. METHODS: EVAR patients with a preoperative dynamic computed tomography angiography (CTA), an immediate postoperative, and a CTA at 3 years after EVAR were included. The preoperative dynamic CTAs consisted of eight images per heartbeat. Aortic diameter and area changes per heartbeat were measured at two levels: (A) 3 cm above and (B) 1 cm below the most distal renal artery. Postoperatively, the distance between the most distal renal artery and the most proximal stent graft ring was measured. Two patient groups were distinguished according to whether migration during follow-up occurred (group 1) or had not occurred (group 2). The aneurysm neck dynamics of the two groups were compared by using the t-test for unpaired data and multivariable logistic regression analyses were performed. Mean values are presented with the standard deviation. RESULTS: Included were 26 patients (19 Talent, 6 Excluder and 1 Lifepath). Stent graft migration of > or =5 mm occurred in 11 patients (group 1). The pulsatility of the AAA neck in these patients was compared with the pulsatility in 15 patients with no graft migration (group 2). There were no significant differences in aortic neck characteristics (angulation, length and diameter) or degree of stent graft oversizing between the two groups. At level A in group 1 versus group 2, the diameter increase during the cardiac cycle was 2.0 +/- 0.3 versus 1.7 +/- 0.3 mm and the aortic area increase was 49 +/- 15 versus 33 +/- 12 mm(2). At level B in group 1 versus group 2, the diameter increase per heartbeat was 1.8 +/- 0.3 versus 1.6 +/- 0.4 mm, and the area increase was 37 +/- 10 versus 25 +/- 15 mm(2). The heartbeat-dependent diameter and area changes at both levels were significantly higher in group 1 compared with group 2. Multivariate regression analysis showed suprarenal aortic pulsatility was a significant predictor for stent graft migration after 3 years. CONCLUSION: The preoperative heartbeat-dependent aneurysm neck distension is significantly associated with stent graft migration after 3 years. The aortic pulsatility in patients with stent graft migration is significantly higher than the pulsatility in patients without stent graft migration.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Migración de Cuerpo Extraño/etiología , Flujo Pulsátil , Stents , Anciano , Anciano de 80 o más Años , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Bases de Datos como Asunto , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
13.
Eur J Vasc Endovasc Surg ; 39(2): 193-9, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19879781

RESUMEN

OBJECTIVE: Dynamic imaging provides insight into aortic shape changes throughout the cardiac cycle. These changes may be important for proximal aortic stent graft fixation, sealing and durability. The objective of this study is to analyse the influence of different types of stent grafts on dynamic changes of the aneurysm neck. METHODS: Pre- and postoperative electrocardiography (ECG)-gated computed tomographic angiography (CTA) scans were obtained in 30 abdominal aortic aneurysm (AAA) patients, 10 each from three different types of stent grafts (10 Talent, Endurant, and Excluder). Each dynamic CTA dataset consisted of eight reconstructed images over the cardiac cycle. Aortic area and radius changes during the cardiac cycle were determined at two levels: (A) 3 cm above and (B) 1 cm below the lowermost renal artery. Radius changes were measured over 360 axes, and plotted in a polar plot. An ellipse was fitted over the plots to determine radius changes over the major and minor axis for assessment of the asymmetric aspect and most prominent direction of distension. RESULTS: Baseline characteristics did not differ significantly between the three groups. Preoperatively, the aortic area increased significantly (p < 0.001) over the cardiac cycle in all patients at both levels: (A) mean increase 8.3 +/- 4.1% (2.0-17.3%); (B) mean increase 5.9 +/- 4.2% (1.9-12.4%). The postoperative aortic area increase over the cardiac cycle did not differ significantly from preoperative increases: (A) mean increase 9.9 +/- 2.2% (4.4-20.0%); (B) mean increase 7.7 +/- 2.4% (3.8-12.4%). The difference between radius change over the major and minor axis was significant both pre- and postoperatively for all three stent grafts, indicating asymmetric distension. Suprarenal, the distension showed a tendency to right-anterior and infrarenal to left-anterior. The distension and direction of the aortic expansion was preserved after stent grafting. There were no differences between the three types of stent grafts regarding their impact on the aortic distension or direction of this distension. CONCLUSION: The aorta expands significantly and asymmetrically throughout the cardiac cycle. After implantation of abdominal aortic stent grafts, the aortic distension and direction of distension remain equally preserved in all three groups. The three stent graft types studied seem to be able to adapt to the asymmetric dynamic aortic shape changes.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular , Stents , Tomografía Computarizada Espiral/métodos , Anciano , Anciano de 80 o más Años , Algoritmos , Aneurisma de la Aorta Abdominal/patología , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flujo Pulsátil , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Resultado del Tratamiento
14.
Eur J Vasc Endovasc Surg ; 38(5): 586-96, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19648032

RESUMEN

OBJECTIVE: An overview of the knowledge of thoracic (TAA), and abdominal aortic aneurysm (AAA) dynamics, before and after endovascular repair, is given. METHODS: Medline, EMBASE and the Cochrane database were searched for relevant articles. After inclusion and exclusion, 25 relevant articles reporting on aneurysm dynamics remained, allowing for comparison. Results provided in the included studies were assumed (statistically) significant if they were larger than the repeatability of the used method. RESULTS: The sample size of dynamic studies is limited and translational studies are missing. Magnetic resonance angiography (MRA) and computed tomographic angiography (CTA) were shown to have lower inter-observer variabilities than ultrasonography (US). The distension of several relevant stent-graft-landing zones during the cardiac cycle in both the abdominal and thoracic aorta are significant (mean diameter change of the AAA neck in the included studies ranged from 0.9 mm to 2.4 mm; mean area change of the thoracic aorta ranged from 4.8% to 12.7% at various levels). This distension remained preserved after stent-graft placement. Preoperatively, the renal arteries displace per heartbeat. Significant movement of the aorta in the anteroposterior (AP) and lateral direction, during the cardiac cycle, was observed. CONCLUSION: The aorta exhibits a wide variety of morphologic changes throughout the cardiac cycle. CTA and MRA are reliable modalities to investigate aortic shape changes during the cardiac cycle. Significant changes per heartbeat are reported in the AAA neck and thoracic aorta. The renal artery displaces per heartbeat. The clinical relevance of dynamic imaging has not been proven yet, but dynamic changes of the aorta have to be taken into account in stent-graft selection and future stent-graft design.


Asunto(s)
Aorta Abdominal/cirugía , Aorta Torácica/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular , Hemodinámica , Aorta Abdominal/patología , Aorta Abdominal/fisiopatología , Aorta Torácica/patología , Aorta Torácica/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma de la Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Torácica/diagnóstico , Aneurisma de la Aorta Torácica/fisiopatología , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Humanos , Angiografía por Resonancia Magnética , Valor Predictivo de las Pruebas , Diseño de Prótesis , Stents , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía Intervencional
15.
Eur J Vasc Endovasc Surg ; 37(2): 168-74, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19046649

RESUMEN

OBJECTIVE: Knowledge of aortic shape changes throughout the cardiac cycle can offer improved understanding of vascular pathophysiology and may have crucial impact on stentgraft design and EVAR durability. To understand underlying mechanisms of dynamic changes in aortic aneurysm (neck) morphology, the undiseased aorta has to be studied first. Objective is to visualize and characterize dynamic aortic shape changes in young healthy volunteers. MATERIALS AND METHODS: Fifteen healthy volunteers (7 male, median age 24 year, range 18-28) were scanned using ECG-gated balanced gradient-echo MRI, with 16 reconstructed cardiac phases. Transverse scans were made perpendicular to the aorta: (A) above the aortic bifurcation, (B) infrarenal, (C) juxtarenal, (D) suprarenal and (E) above the celiac trunk. After aortic lumen segmentation, radial changes during the cardiac cycle were measured, from the center of mass, over 360 degrees, and plotted. An ellipse was fitted over the distention plots, yielding the direction (AP:0 degrees, Right: -90 degrees, Left: 90 degrees ) and magnitude of radius change over the major and minor axis. RESULTS: Asymmetric distention was observed, with a variable rate per patient and level. Radius changes decreased from the proximal to distal aorta. Radius changes over the major axis ranged from 14% to 41%. At level A mean change in radius over the minor versus major axis was 1.4+/-0.2mm (17%) versus 1.6+/-0.2mm (20%), respectively. At B 1.7+/-0.4mm (22%) versus 2.0+/-0.4mm (25%), at C 1.7+/-0.4mm (22%) versus 2.2+/-0.4mm (27%) at D 2.0+/-0.4mm (25%) versus 2.4+/-0.5mm (30%) and at E 2.2+/-0.3mm (27%) versus 2.6+/-0.3mm (32%). Mean orientation of the major axis was (A) 0.8+/-23.3 degrees , (B) 1.8+/-31.3 degrees , (C) 14.0+/-15.5 degrees , (D) -28.8+/-48.0 degrees and (E) 18.4+/-22.2 degrees. CONCLUSIONS: Aortic pulsatile distention in young healthy volunteers is asymmetric, with up to 41% radius change in the descending aorta. This study offers a frame of reference for dynamic imaging studies in patients with aortic pathology and provides a valuable non-invasive tool for future research into aortic distention, development and localization of vascular pathology.


Asunto(s)
Aorta/anatomía & histología , Aorta/fisiología , Electrocardiografía , Imagen por Resonancia Magnética , Flujo Pulsátil , Adolescente , Adulto , Adaptabilidad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Valores de Referencia , Factores de Tiempo , Adulto Joven
16.
Eur J Vasc Endovasc Surg ; 38(1): 42-53, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19428273

RESUMEN

OBJECTIVE: Sizing of aortic endografts is an essential step in successful endovascular treatment of aortic pathology, although consensus regarding the optimal sizing strategy is lacking. Some proximal oversizing is necessary to obtain a seal between the stent graft and the aortic wall and to prevent the graft from migrating, but excessive oversizing might influence the results negatively. In this systematic review, we investigated the current literature to obtain an overview of the risks and benefits of oversizing and to determine the optimal degree of oversizing of stent grafts used for endovascular abdominal aortic aneurysm repair. METHODS: PUBMED, EMBASE and Cochrane Library databases were searched for articles related to the impact of proximal endograft oversizing on complications after endovascular aneurysm repair. After in- and exclusion, 23 relevant articles reporting on 8415 patients remained for analysis and critical appraisal. RESULTS: Most studies that investigated neck dilatation are flawed by poor methodology. No clear relationship between proximal oversizing and neck dilatation relative to the first post-operative scan was found. None of the studies described a positive relationship between the degree of oversizing and the incidence of endoleaks. On the contrary, oversizing up to 25% seems to decrease the risk of proximal endoleaks. There are conflicting data regarding the risk of graft migration when oversizing by more than 30%. CONCLUSIONS: Based on the best available evidence, the current standard of 10-20% oversizing regime appears to be relatively safe and preferable. Oversizing >30% might negatively impact the outcome after EVAR. Studies of higher quality are needed to further assess the relationship between proximal oversizing and the incidence of complications, particularly regarding the impact on aneurysm neck dilatation.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Medición de Riesgo/métodos , Stents/normas , Migración de Cuerpo Extraño/epidemiología , Humanos , Diseño de Prótesis , Falla de Prótesis , Factores de Riesgo
17.
J Cardiovasc Surg (Torino) ; 50(2): 153-8, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19329911

RESUMEN

The evolution of stent-grafts and endovascular delivery systems has substantially improved the application rate for and patient outcomes with endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA), but further development is needed in order to reduce the continuing incidence of complications and secondary re-interventions. Severe angulations at the proximal aneurysm neck and tortuous, calcified, and small iliac arteries are still recognized as important risk factors for successful EVAR of AAA and hence as criteria for exclusion of many potential patients. The Endurant stent-graft is part of a next-generation system that was designed with the clear intention of expanding the applicability of EVAR for AAA while also continuing to improve treatment outcomes and reduce complications. Innovative features of the system design include anchoring pins for ensuring proximal fixation, wire-formed M-shape body stents for improved flexibility and conformability, and a low-profile delivery system with hydrophilic coating that improves trackability and pushability to facilitate the vascular access even in small challenging arteries. Initial clinical experience with the Endurant stent-graft system, including preliminary results from the first-in-human European trial of the device, has demonstrated that the device can be delivered and deployed safely, even in highly angulated anatomies. Technical success was achieved in 90.3% of the patients in the trial. No device-related serious adverse events were seen during the first follow-up period, and no device-related deaths were reported. This new stent-graft will potentially enlarge the patient population suitable for EVAR of AAA.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Stents , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Ensayos Clínicos como Asunto , Femenino , Humanos , Masculino , Estudios Multicéntricos como Asunto , Diseño de Prótesis , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
18.
Sci Rep ; 9(1): 8108, 2019 05 30.
Artículo en Inglés | MEDLINE | ID: mdl-31147576

RESUMEN

The extracranial carotid artery aneurysm (ECAA) is a rare pathology for which clinical treatment guidelines are lacking. In general, symptoms or growth of the aneurysm sac are thought to indicate intervention. ECAAs may present in a large variety of shapes and sizes, and conventional diameter measurements fail to indicate geometrical differences. Therefore, we propose a protocol to measure ECAA size by 3D volumetric assessment. The volumes of 40 ECAAs in computed tomography angiography (CTA) images were measured through manual segmentation, by two independent operators. Volumes of the entire internal carotid artery (ICA) and the ECAA were measured separately. Excellent inter- and intraoperator reliability was found for both ICA and ECAA volumes, with all intraclass correlation coefficients above 0.94. Bland-Altman analysis revealed normal differences for both inter- and intraoperator agreement. For all volumes, similarity of the segmentations was excellent. Outliers were explained by presence of intraluminal ECAA thrombus, which hampered identification of the aneurysm outer wall. These results implicate robustness of our protocol, which is designed as a step-up towards (semi)automatic volumetric measurements to monitor patients with ECAA. Future (semi)automatic volumetric assessments are recommended and such techniques can be developed and validated using the proposed protocol and manual reference segmentations.


Asunto(s)
Arterias Carótidas/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Arterias Carótidas/patología , Enfermedades de las Arterias Carótidas/diagnóstico , Enfermedades de las Arterias Carótidas/patología , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/patología , Angiografía por Tomografía Computarizada/métodos , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico , Aneurisma Intracraneal/patología , Masculino , Persona de Mediana Edad
19.
Am J Clin Nutr ; 110(4): 883-890, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31387121

RESUMEN

BACKGROUND: Vitamin K occurs in the diet as phylloquinone and menaquinones. Observational studies have shown that both phylloquinone and menaquinone intake might reduce cardiovascular disease (CVD) risk. However, the effect of vitamin K on vascular calcification is unknown. OBJECTIVES: The aim of this study was to assess if menaquinone supplementation, compared to placebo, decreases vascular calcification in people with type 2 diabetes and known CVD. METHODS: In this double-blind, randomized, placebo-controlled trial, we randomly assigned men and women with type 2 diabetes and CVD to 360 µg/d menaquinone-7 (MK-7) or placebo for 6 mo. Femoral arterial calcification at baseline and 6 mo was measured with 18sodium fluoride positron emission tomography (18F-NaF PET) scans as target-to-background ratios (TBRs), a promising technique to detect active calcification. Calcification mass on conventional computed tomography (CT) scan was measured as secondary outcome. Dephosphorylated-uncarboxylated matrix Gla protein (dp-ucMGP) concentrations were measured to assess compliance. Linear regression analyses were performed with either TBR or CT calcification at follow-up as the dependent variable, and treatment and baseline TBR or CT calcification as independent variables. RESULTS: We randomly assigned 35 patients to the MK-7 group (33 completed follow-up) and 33 to the placebo group (27 completed follow-up). After the 6-mo intervention, TBR tended to increase in the MK-7 group compared with placebo (0.25; 95% CI: -0.02, 0.51; P = 0.06), although this was not significant. Log-transformed CT calcification mass did not increase in the intervention group compared with placebo (0.50; 95% CI: -0.23, 1.36; P = 0.18). MK-7 supplementation significantly reduced dp-ucMGP compared with placebo (-205.6 pmol/L; 95% CI: -255.8, -155.3 pmol/L). No adverse events were reported. CONCLUSION: MK-7 supplementation tended to increase active calcification measured with 18F-NaF PET activity compared with placebo, but no effect was found on conventional CT. Additional research investigating the interpretation of 18F-NaF PET activity is necessary. This trial was registered at clinicaltrials.gov as NCT02839044.


Asunto(s)
Diabetes Mellitus Tipo 2/complicaciones , Calcificación Vascular/prevención & control , Vitamina K 2/análogos & derivados , Anciano , Suplementos Dietéticos , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Calcificación Vascular/complicaciones , Vitamina K 2/administración & dosificación , Vitamina K 2/farmacología
20.
Eur J Vasc Endovasc Surg ; 36(3): 339-45, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18602847

RESUMEN

BACKGROUND: This study aimed to review the literature regarding fracture of arterial stents, especially its relation to location of placement, clinical relevance, and type of stents. MATERIAL AND METHODS: We searched published articles in PubMed up to February 2008 by using the terms: stent fracture or stent breakage. RESULTS: Thirty-one articles met our inclusion and exclusion criteria. Most of the studies reported fractures in stents placed in the superficial femoral artery or popliteal arteries. The cumulative incidence of stent fractures ranged from 2% to 65%, i.e. 0.6 to 60 per 1000 person-months. Stent fractures occur more frequently in the superficial femoral artery and are common when multiple stents are deployed and overlap. Stent fractures are associated with a higher risk of in-stent restenosis and re-occlusion. CONCLUSION: The incidence of stent fracture, its location of placement, and type of stent used were diverse across studies. Stent fracture may cause clinical deterioration especially in the femoropopliteal segment, and it should be detected before clinical manifestation appears. Further studies with larger study population involving new type of stents for a longer follow up period are warranted.


Asunto(s)
Arteriopatías Oclusivas/etiología , Arteria Femoral , Falla de Prótesis , Stents/efectos adversos , Stents/estadística & datos numéricos , Humanos , Incidencia , Recurrencia