Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Biotechnol Bioeng ; 112(1): 220-7, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25088405

RESUMEN

The use of stem cells for the repair of damaged cardiac tissue after a myocardial infarction holds great promise. However, a common finding in experimental studies is the low number of cells delivered at the area at risk. To improve the delivery, we are currently investigating a novel delivery platform in which stem cells are conjugated with targeted microbubbles, creating echogenic complexes dubbed StemBells. These StemBells vibrate in response to incoming ultrasound waves making them susceptible to acoustic radiation force. The acoustic force can then be employed to propel circulating StemBells from the centerline of the vessel to the wall, facilitating localized stem cell delivery. In this study, we investigate the feasibility of manipulating StemBells acoustically in vivo after injection using a chicken embryo model. Bare stem cells or unsaturated stem cells (<5 bubbles/cell) do not respond to ultrasound application (1 MHz, peak negative acoustical pressure P_ = 200 kPa, 10% duty cycle). However, stem cells which are fully saturated with targeted microbubbles (>30 bubbles/cell) can be propelled toward and arrested at the vessel wall. The mean translational velocities measured are 61 and 177 µm/s for P- = 200 and 450 kPa, respectively. This technique therefore offers potential for enhanced and well-controlled stem cell delivery for improved cardiac repair after a myocardial infarction.


Asunto(s)
Trasplante de Células Madre Mesenquimatosas , Microburbujas , Microscopía/métodos , Células Madre/citología , Acústica , Animales , Células Cultivadas , Embrión de Pollo , Pollos , Humanos
2.
Ultraschall Med ; 36(2): 154-61, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24824762

RESUMEN

PURPOSE: Intraplaque neovascularization (IPN) is an increasingly studied marker of the vulnerable atherosclerotic plaque, and contrast-enhanced ultrasound (CEUS) is an in vivo imaging technique for the assessment of IPN. The purpose of this study was to test novel quantification methods for the detection of carotid IPN using CEUS. MATERIALS AND METHODS: 25 patients with established carotid atherosclerosis underwent bilateral carotid CEUS using a Philips iU-22 ultrasound system with an L9 - 3 transducer. Visual scoring of IPN was performed using a 3-point score. Quantification of IPN was performed using novel custom developed software. In short, regions of interest were drawn over the atherosclerotic plaques. After motion compensation, several IPN features were calculated. Statistical analysis was performed using Spearman's rho. Reproducibility of the quantification features was calculated using intra-class correlation coefficients and mean differences between calculations. RESULTS: 45 carotid arteries were available for the quantification of IPN. The quantification of IPN was feasible in all 45 carotid plaques. The IPN area, IPN area ratio and neovessel count had a good correlation with the visual IPN score (respectively ρ = 0.719, ρ = 0.538, ρ = 0.474 all p < 0.01). The intra-observer and inter-observer agreement was good to excellent (p < 0.01). The intra-observer and inter-observer variability was low. CONCLUSION: The quantification of carotid IPN on CEUS is feasible and provides multiple features on carotid IPN. Accurate quantitative assessment of IPN may be important to recognize and to monitor changes during therapy in vulnerable atherosclerotic plaques.


Asunto(s)
Arteria Carótida Interna/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Medios de Contraste , Aumento de la Imagen , Interpretación de Imagen Asistida por Computador , Neovascularización Patológica/diagnóstico por imagen , Programas Informáticos , Anciano , Estudios de Factibilidad , Femenino , Humanos , Ataque Isquémico Transitorio/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Factores de Riesgo , Ultrasonografía
3.
J Acoust Soc Am ; 132(6): EL470-5, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23231210

RESUMEN

An acoustical method was developed to study the resonance of single lipid-coated microbubbles. The response of 127 SonoVue microbubbles to a swept sine excitation between 0.5 and 5.5 MHz with a peak acoustic pressure amplitude of 70 kPa was measured by means of a 25 MHz probing wave. The relative amplitude modulation in the signal scattered in response to the probing wave is approximately equal to the radial strain induced by the swept sine excitation. An average damping coefficient of 0.33 and an average resonance frequency of 2.5 MHz were measured. Microbubbles experienced an average peak radial strain of 20%.


Asunto(s)
Medios de Contraste , Microburbujas , Fosfolípidos , Hexafluoruro de Azufre , Ultrasonido/métodos , Simulación por Computador , Análisis de los Mínimos Cuadrados , Dinámicas no Lineales , Análisis Numérico Asistido por Computador , Tamaño de la Partícula , Presión , Procesamiento de Señales Asistido por Computador , Espectrografía del Sonido , Factores de Tiempo , Transductores de Presión , Ultrasonido/instrumentación , Vibración , Agua
4.
Front Bioeng Biotechnol ; 9: 828577, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35155418

RESUMEN

The role of wall shear stress (WSS) in atherosclerotic plaque development is evident, but the relation between WSS and plaque composition in advanced atherosclerosis, potentially resulting in plaque destabilization, is a topic of discussion. Using our previously developed image registration pipeline, we investigated the relation between two WSS metrics, time-averaged WSS (TAWSS) and the oscillatory shear index (OSI), and the local histologically determined plaque composition in a set of advanced human carotid plaques. Our dataset of 11 carotid endarterectomy samples yielded 87 histological cross-sections, which yielded 511 radial bins for analysis. Both TAWSS and OSI values were subdivided into patient-specific low, mid, and high tertiles. This cross-sectional study shows that necrotic core (NC) size and macrophage area are significantly larger in areas exposed to high TAWSS or low OSI. Local TAWSS and OSI tertile values were generally inversely related, as described in the literature, but other combinations were also found. Investigating the relation between plaque vulnerability features and different combinations of TAWSS and OSI tertile values revealed a significantly larger cap thickness in areas exposed to both low TAWSS and low OSI. In conclusion, our study confirmed previous findings, correlating high TAWSS to larger macrophage areas and necrotic core sizes. In addition, our study demonstrated new relations, correlating low OSI to larger macrophage areas, and a combination of low TAWSS and low OSI to larger cap thickness.

5.
AJNR Am J Neuroradiol ; 42(1): 144-151, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33214179

RESUMEN

BACKGROUND AND PURPOSE: Plaque ulceration is a marker of previous plaque rupture. We studied the association between atherosclerotic plaque composition at baseline and plaque ulceration at baseline and follow-up. MATERIALS AND METHODS: We included symptomatic patients with a carotid stenosis of <70% who underwent MDCTA and MR imaging at baseline (n = 180). MDCTA was repeated at 2 years (n = 73). We assessed the presence of ulceration using MDCTA. Baseline MR imaging was used to assess the vessel wall volume and the presence and volume of plaque components (intraplaque hemorrhage, lipid-rich necrotic core, and calcifications) and the fibrous cap status. Associations at baseline were evaluated with binary logistic regression and reported with an OR and its 95% CI. Simple statistical testing was performed in the follow-up analysis. RESULTS: At baseline, the prevalence of plaque ulceration was 27% (49/180). Increased wall volume (OR = 12.1; 95% CI, 3.5-42.0), higher relative lipid-rich necrotic core (OR = 1.7; 95% CI, 1.3-2.2), higher relative intraplaque hemorrhage volume (OR = 1.7; 95% CI, 1.3-2.2), and a thin-or-ruptured fibrous cap (OR = 3.4; 95% CI, 1.7-6.7) were associated with the presence of ulcerations at baseline. In 8% (6/73) of the patients, a new ulcer developed. Plaques with a new ulceration at follow-up had at baseline a larger wall volume (1.04 cm3 [IQR, 0.97-1.16 cm3] versus 0.86 cm3 [IQR, 0.73-1.00 cm3]; P = .029), a larger relative lipid-rich necrotic core volume (23% [IQR, 13-31%] versus 2% [IQR, 0-14%]; P = .002), and a larger relative intraplaque hemorrhage volume (14% [IQR, 8-24%] versus 0% [IQR, 0-5%]; P < .001). CONCLUSIONS: Large atherosclerotic plaques and plaques with intraplaque hemorrhage and lipid-rich necrotic cores were associated with plaque ulcerations at baseline and follow-up.


Asunto(s)
Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/patología , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/patología , Anciano , Femenino , Humanos , Lípidos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Necrosis/patología , Úlcera/patología
6.
Eur J Vasc Endovasc Surg ; 40(1): 47-53, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20346709

RESUMEN

OBJECTIVE: Local anatomy and the patient's risk profile independently affect the expansion rate of an abdominal aortic aneurysm. We describe a hybrid method that combines finite element modelling and statistical methods to predict patient-specific aneurysm expansion. METHODS: The 3-D geometry of the aneurysm was imaged with computed tomography. We used finite element methods to calculate wall stress and aneurysm expansion. Expansion rate was adjusted by risk factors obtained from a database of 80 patients. Aneurysm diameters predicted with and without the risk profiles were compared with diameters measured with ultrasound for 11 patients. RESULTS: For this specific group of patients, local anatomy contributed 62% and the risk profile 38% to the aneurysmal expansion rate. Predictions with risk profiles resulted in smaller root mean square errors than predictions without risk profiles (2.9 vs. 4.0 mm, p < 0.01). CONCLUSIONS: This hybrid approach predicted aneurysmal expansion for a period of 30 months with high accuracy.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico , Rotura de la Aorta/diagnóstico , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Rotura de la Aorta/diagnóstico por imagen , Aortografía/métodos , Progresión de la Enfermedad , Femenino , Análisis de Elementos Finitos , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares , Valor Predictivo de las Pruebas , Pronóstico , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Estrés Mecánico , Factores de Tiempo , Tomografía Computarizada por Rayos X , Ultrasonografía
7.
IEEE Trans Med Imaging ; 39(5): 1535-1544, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31725370

RESUMEN

We demonstrate three-dimensional intravascular flow imaging compatible with routine clinical image acquisition workflow by means of megahertz (MHz) intravascular Doppler Optical Coherence Tomography (OCT). The OCT system relies on a 1.1 mm diameter motorized imaging catheter and a 1.5 MHz Fourier Domain Mode Locked (FDML) laser. Using a post processing method to compensate the drift of the FDML laser output, we can resolve the Doppler phase shift between two adjoining OCT A-line datasets. By interpretation of the velocity field as measured around the zero phase shift, the flow direction at specific angles can be qualitatively estimated. Imaging experiments were carried out in phantoms, micro channels, and swine coronary artery in vitro at a speed of 600 frames/s. The MHz wavelength sweep rate of the OCT system allows us to directly investigate flow velocity of up to 37.5 cm/s while computationally expensive phase-unwrapping has to be applied to measure such high speed using conventional OCT system. The MHz sweep rate also enables a volumetric Doppler imaging even with a fast pullback at 40 mm/s. We present the first simultaneously recorded 3D morphological images and Doppler flow profiles. Flow pattern estimation and three-dimensional structural reconstruction of entire coronary artery are achieved using a single OCT pullback dataset.


Asunto(s)
Vasos Coronarios , Tomografía de Coherencia Óptica , Animales , Vasos Coronarios/diagnóstico por imagen , Imagenología Tridimensional , Rayos Láser , Fantasmas de Imagen , Porcinos
8.
Phys Med Biol ; 54(6): 1397-418, 2009 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-19218736

RESUMEN

This paper describes a novel method for estimating tissue motion in two-dimensional intravascular ultrasound (IVUS) images of a coronary artery. It is based on the classical Lukas-Kanade (LK) algorithm for optical flow (OF). The OF vector field quantifies the amount of misalignment between two consecutive frames in a sequence of images. From the theoretical standpoint, two fundamental improvements are proposed in this paper. First, using a simplified representation of the vessel wall as a medium with randomly distributed scatterers, it was shown that the OF equation satisfies the integral brightness conservation law. Second, a scale-space embedding for the OF equation was derived under the assumption of spatial consistency in IVUS acquisitions. The spatial coherence is equivalent to a locally affine motion model. The latter effectively captures and appropriately describes a complex deformation pattern of the coronary vessel wall under the varying physiological conditions (i.e. pulsatile blood pressure). The accuracy of OF tracking was estimated on the tissue-mimicking phantoms subjected to the controlled amount of angular deviation. Moreover, the performance of the classical LK and proposed approach was compared using the simulated IVUS images with an atherosclerotic lesion. The experimental results showed robust and reliable performance of up to 5 degrees of rotation, which is within the plausible range of circumferential displacement of the coronary arteries. Subsequently, the algorithm was used to analyze vessel wall motion in 18 IVUS pullbacks from 16 patients. The in vivo experiments revealed that the motion of coronary arteries is primarily determined by the cardiac contraction.


Asunto(s)
Vasos Coronarios/fisiología , Movimiento , Ultrasonografía Intervencional/métodos , Artefactos , Fenómenos Biomecánicos , Vasos Coronarios/fisiopatología , Humanos , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Rotación , Sensibilidad y Especificidad
9.
Ultrasound Obstet Gynecol ; 33(6): 638-44, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19434670

RESUMEN

OBJECTIVES: To obtain Doppler velocity waveforms from the early embryonic chicken heart by means of ultrasound biomicroscopy and to compare these waveforms at different stages of embryonic development. METHODS: We collected cardiac waveforms using high-frequency Doppler ultrasound with a 55-MHz transducer at Hamburger-Hamilton (HH) stages 18, 21 and 23, which are comparable to humans at 5 to 8 weeks of gestation. Waveforms were obtained at the inflow tract, the primitive left ventricle, the primitive right ventricle and at the outflow tract in 10 different embryos per stage. M-mode recordings were collected to study opening and closure of the cushions. By exploring the temporal relationship between the waveforms, using a secondary Doppler device, cardiac cycle events were outlined. RESULTS: Our results demonstrate that stage- and location-dependent intracardiac blood flow velocity waveforms can be obtained in the chicken embryo. The blood flow profiles assessed at the four locations in the embryonic heart demonstrated an increase in peak velocity with advancing developmental stage. In the primitive ventricle the 'passive' (P) filling peak decreased whereas the 'active' (A) filling peak increased, resulting in a decrease in P to A ratio with advancing developmental stage. M-mode recordings demonstrated that the fractional closure time of the atrioventricular cushions increased from 20% at stage HH 18 to 60% at stage HH 23. CONCLUSION: High-frequency ultrasound biomicroscopy can be used to define flow velocity waveforms in the embryonic chicken heart. This may contribute to an understanding of Doppler signals derived from valveless embryonic human hearts at 5 to 8 weeks of gestation, prior to septation.


Asunto(s)
Corazón/fisiología , Animales , Velocidad del Flujo Sanguíneo/fisiología , Embrión de Pollo , Edad Gestacional , Corazón/embriología , Humanos , Flujometría por Láser-Doppler
10.
PLoS One ; 14(6): e0217271, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31170183

RESUMEN

Wall shear stress (WSS), the frictional force exerted on endothelial cells by blood flow, is hypothesised to influence atherosclerotic plaque growth and composition. We developed a methodology for image registration of MR and histology images of advanced human carotid plaques and corresponding WSS data, obtained by MRI and computational fluid dynamics. The image registration method requires four types of input images, in vivo MRI, ex vivo MRI, photographs of transversally sectioned plaque tissue and histology images. These images are transformed to a shared 3D image domain by applying a combination of rigid and non-rigid registration algorithms. Transformation matrices obtained from registration of these images are used to transform subject-specific WSS data to the shared 3D image domain as well. WSS values originating from the 3D WSS map are visualised in 2D on the corresponding lumen locations in the histological sections and divided into eight radial segments. In each radial segment, the correlation between WSS values and plaque composition based on histological parameters can be assessed. The registration method was successfully applied to two carotid endarterectomy specimens. The resulting matched contours from the imaging modalities had Hausdorff distances between 0.57 and 0.70 mm, which is in the order of magnitude of the in vivo MRI resolution. We simulated the effect of a mismatch in the rigid registration of imaging modalities on WSS results by relocating the WSS data with respect to the stack of histology images. A 0.6 mm relocation altered the mean WSS values projected on radial bins on average by 0.59 Pa, compared to the output of original registration. This mismatch of one image slice did not change the correlation between WSS and plaque thickness. In conclusion, we created a method to investigate correlations between WSS and plaque composition.


Asunto(s)
Arterias Carótidas , Enfermedades de las Arterias Carótidas , Endarterectomía , Hemorreología , Angiografía por Resonancia Magnética , Placa Aterosclerótica , Resistencia al Corte , Arterias Carótidas/diagnóstico por imagen , Arterias Carótidas/fisiopatología , Arterias Carótidas/cirugía , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/fisiopatología , Enfermedades de las Arterias Carótidas/cirugía , Femenino , Humanos , Masculino , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/fisiopatología , Placa Aterosclerótica/cirugía
12.
Ultrasound Med Biol ; 34(2): 196-207, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17935871

RESUMEN

Automated segmentation approaches for the left ventricle (LV) in 3-D echocardiography (3DE) often rely on manual initialization. So far, little effort has been put into automating the initialization procedure to get to a fully automatic segmentation approach. We propose a fully automatic method for the detection of the LV long axis (LAX) and the mitral valve plane (MVP) over the full cardiac cycle, for the initialization of segmentation algorithms in 3DE. Our method exploits the cyclic motion of the LV and therefore detects salient structures in a time-continuous way. Probabilities to candidate LV center points are assigned through a Hough transform for circles. The LV LAX is detected by combining dynamic programming detections on these probabilities in 3-D and 2D + time to obtain a time continuous solution. Subsequently, the mitral valve plane is detected in a projection of the data on a plane through the previously detected LAX. The method easily adjusts to different acquisition routines and combines robustness with good accuracy and low computational costs. Automatic detection was evaluated using patient data acquired with the fast rotating ultrasound (FRU) transducer (n=11 patients) and with the Philips Sonos 7500 ultrasound system (Philips Medical Systems, Andover, MA, USA), with the X4 matrix transducer (n=14 patients). For the FRU-transducer data, the LAX was estimated with a distance error of 2.85+/-1.70 mm (mean+/-SD) and an angle of 5.25+/-3.17 degrees; the mitral valve plane was estimated with a distance of -1.54+/-4.31 mm. For the matrix data, these distances were 1.96+/-1.30 mm with an angle error of 5.95+/-2.11 and -1.66+/-5.27 mm for the mitral valve plane. These results confirm that the method is very suitable for automatic detection of the LV LAX and MVP. It provides a basis for further automatic exploration of the LV and could therefore serve as a replacement of manual initialization of 3-D segmentation approaches.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Cardiopatías/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Válvula Mitral/diagnóstico por imagen , Humanos , Variaciones Dependientes del Observador
13.
Neth Heart J ; 16(7-8): 280-3, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18711619

RESUMEN

Shear stress of the blood at the vessel wall plays an important role in many processes in the cardiovascular system primarily focused on the regulation of vessel lumen and wall dimensions. There is ample evidence that atherosclerotic plaques are generated at low shear stress regions in the cardiovascular system, while high shear stress regions are protected. In the course of plaque progression, advanced plaques start to encroach into the lumen, and thereby start to experience high shear stress at the endothelium. Until now the consequences of high shear stress working at the endothelium of an advanced plaque are unknown. As high shear stress influences tissue regression, we hypothesised that high shear stress can destabilise the plaque by cap weakening leading to ulceration. We investigated this hypothesis in a magnetic resonance imaging (MRI) dataset of a 67-year-old woman with a plaque in the carotid artery at baseline and an ulcer at ten-month follow-up. The lumen, plaque components (lipid/necrotic core, intraplaque haemorrhage) and ulcer were reconstructed three dimensionally and the geometry at baseline was used for shear stress calculation using computational fluid dynamics. Correlation of the change in plaque composition with the shear stress at baseline showed that the ulcer was generated exclusively at the high shear stress location. In this serial MRI study we found plaque ulceration at the high shear stress location of a protruding plaque in the carotid artery. Our data suggest that high shear stress influences plaque vulnerability and therefore may become a potential parameter for predicting future events. (Neth Heart J 2008;16:280-3.).

14.
R Soc Open Sci ; 5(3): 171447, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29657758

RESUMEN

Wall shear stress (WSS) is involved in atherosclerotic plaque initiation, yet its role in plaque progression remains unclear. We aimed to study (i) the temporal and spatial changes in WSS over a growing plaque and (ii) the correlation between WSS and plaque composition, using animal-specific data in an atherosclerotic mouse model. Tapered casts were placed around the right common carotid arteries (RCCA) of ApoE-/- mice. At 5, 7 and 9 weeks after cast placement, RCCA geometry was reconstructed using contrast-enhanced micro-CT. Lumen narrowing was observed in all mice, indicating the progression of a lumen intruding plaque. Next, we determined the flow rate in the RCCA of each mouse using Doppler Ultrasound and computed WSS at all time points. Over time, as the plaque developed and further intruded into the lumen, absolute WSS significantly decreased. Finally at week 9, plaque composition was histologically characterized. The proximal part of the plaque was small and eccentric, exposed to relatively lower WSS. Close to the cast a larger and concentric plaque was present, exposed to relatively higher WSS. Lower WSS was significantly correlated to the accumulation of macrophages in the eccentric plaque. When pooling data of all animals, correlation between WSS and plaque composition was weak and no longer statistically significant. In conclusion, our data showed that in our mouse model absolute WSS strikingly decreased during disease progression, which was significantly correlated to plaque area and macrophage content. Besides, our study demonstrates the necessity to analyse individual animals and plaques when studying correlations between WSS and plaque composition.

15.
Phys Med Biol ; 63(7): 075015, 2018 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-29508770

RESUMEN

Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound system, and to achieve a high volume rate (>200 Hz). To address these issues, we have recently developed a prototype miniaturized matrix transducer for pediatric patients with micro-beamforming and a small central transmitter. In this paper we propose two multiline parallel 3D beamforming techniques (µBF25 and µBF169) using the micro-beamformed datasets from 25 and 169 transmit events to achieve volume rates of 300 Hz and 44 Hz, respectively. Both the realizations use angle-weighted combination of the neighboring overlapping sub-volumes to avoid artifacts due to sharp intensity changes introduced by parallel beamforming. In simulation, the image quality in terms of the width of the point spread function (PSF), lateral shift invariance and mean clutter level for volumes produced by µBF25 and µBF169 are similar to the idealized beamforming using a conventional single-line acquisition with a fully-sampled matrix transducer (FS4k, 4225 transmit events). For completeness, we also investigated a 9 transmit-scheme (3 × 3) that allows even higher frame rates but found worse B-mode image quality with our probe. The simulations were experimentally verified by acquiring the µBF datasets from the prototype using a Verasonics V1 research ultrasound system. For both µBF169 and µBF25, the experimental PSFs were similar to the simulated PSFs, but in the experimental PSFs, the clutter level was ~10 dB higher. Results indicate that the proposed multiline 3D beamforming techniques with the prototype matrix transducer are promising candidates for real-time pediatric 3D TEE.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Corazón/diagnóstico por imagen , Fantasmas de Imagen , Ultrasonografía/métodos , Niño , Conjuntos de Datos como Asunto , Humanos , Transductores
16.
Sci Rep ; 8(1): 14014, 2018 09 18.
Artículo en Inglés | MEDLINE | ID: mdl-30228313

RESUMEN

The heart rate lowering drug Ivabradine was shown to improve cardiac outcome in patients with previous heart failure. However, in patients without heart failure, no beneficial effect of Ivabradine was observed. Animal studies suggested a preventive effect of Ivabradine on atherosclerosis which was due to an increase in wall shear stress (WSS), the blood flow-induced frictional force exerted on the endothelium, triggering anti-inflammatory responses. However, data on the effect of Ivabradine on WSS is sparse. We aim to study the effect of Ivabradine on (i) the 3D WSS distribution over a growing plaque and (ii) plaque composition. We induced atherosclerosis in ApoE-/- mice by placing a tapered cast around the right common carotid artery (RCCA). Five weeks after cast placement, Ivabradine was administered via drinking water (15 mg/kg/day) for 2 weeks, after which the RCCA was excised for histology analyses. Before and after Ivabradine treatment, animals were imaged with Doppler Ultrasound to measure blood velocity. Vessel geometry was obtained using contrast-enhanced micro-CT. Time-averaged WSS during systole, diastole and peak WSS was subsequently computed. Ivabradine significantly decreased heart rate (459 ± 28 bpm vs. 567 ± 32 bpm, p < 0.001). Normalized peak flow significantly increased in the Ivabradine group (124.2% ± 40.5% vs. 87.3% ± 25.4%, p < 0.05), reflected by an increased normalized WSS level during systole (110.7% ± 18.4% vs. 75.4% ± 24.6%, p < 0.05). However, plaque size or composition including plaque area, relative necrotic core area and macrophage content were not altered in mice treated with Ivabradine compared to controls. We conclude that increased WSS in response to Ivabradine treatment did not affect plaque progression in a murine model.


Asunto(s)
Aterosclerosis/tratamiento farmacológico , Modelos Animales de Enfermedad , Frecuencia Cardíaca/fisiología , Hemodinámica , Ivabradina/farmacología , Placa Aterosclerótica/prevención & control , Animales , Aterosclerosis/patología , Fármacos Cardiovasculares/farmacología , Frecuencia Cardíaca/efectos de los fármacos , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados para ApoE , Placa Aterosclerótica/patología , Estrés Mecánico
17.
Biomed Opt Express ; 8(2): 943-953, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-28270995

RESUMEN

Lipid deposition can be assessed with combined intravascular photoacoustic/ultrasound (IVPA/US) imaging. To date, the clinical translation of IVPA/US imaging has been stalled by a low imaging speed and catheter complexity. In this paper, we demonstrate imaging of lipid targets in swine coronary arteries in vivo, at a clinically useful frame rate of 20 s-1. We confirmed image contrast for atherosclerotic plaque in human samples ex vivo. The system is on a mobile platform and provides real-time data visualization during acquisition. We achieved an IVPA signal-to-noise ratio of 20 dB. These data show that clinical translation of IVPA is possible in principle.

18.
Phys Med Biol ; 51(22): 5875-87, 2006 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-17068370

RESUMEN

Intracoronary thermography is a technique that measures lumen wall temperatures for vulnerable plaque detection. In this paper the influence of vulnerable plaque composition on lumen wall temperatures was studied numerically. Concerning the vulnerable plaque heat generation, the location of the heat source and its heat production were varied. Concerning the heat transfer, the thermal properties of the lipid core and the location of the vasa vasorum were studied. The heat source location was the main determinant of the lumen wall temperature distribution. The strongest effect was noted when the heat producing macrophages were located in the shoulder region leading to focal spots of higher temperature. The maximal lumen wall temperature was mainly determined by the heat production of the macrophages and the cooling effect of blood. The insulating properties of the lipid core increased lumen wall temperatures when the heat source was located in the cap and the presence of vasa vasorum lowered the temperatures. These results show that the lumen wall temperature distribution is influenced by vulnerable plaque composition and that intracoronary thermography techniques require a high spatial resolution. To be able to couple temperature measurements to plaque vulnerability, intracoronary thermography needs to be combined with an imaging modality.


Asunto(s)
Regulación de la Temperatura Corporal , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Diagnóstico por Computador/métodos , Modelos Cardiovasculares , Termografía/métodos , Animales , Temperatura Corporal , Simulación por Computador , Humanos
19.
Ultrasound Med Biol ; 32(4): 569-77, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16616602

RESUMEN

An experimental lipid encapsulated contrast agent comprised substantially of micrometer to submicrometer diameter bubbles was evaluated for its capacity to produce nonlinear scattering in response to high transmit frequencies. Agent characterization experiments were conducted at transmit frequencies of 20 and 30 MHz with bandwidths of 5, 15 and 25% using a broadband focused PVDF transducer. The presence of subharmonic energy was observed for all bandwidths at a wide range of pressures (0.49 to 5.7 MPa and 0.45 to 4.5 MPa for the 20 and 30 MHz cases, respectively). Distinct ultraharmonics were observed only in the 5% bandwidth cases. Second harmonic energy was also present, but this was at least partly due to nonlinear propagation, as indicated by linear scatterer signals. Evidence of destruction was found only at higher peak negative pressures (e.g., >2 MPa for 30 MHz 5% bandwidth pulse). The results suggest that small lipid bubble formulations may be useful for the purposes of high frequency nonlinear contrast imaging.


Asunto(s)
Medios de Contraste , Microburbujas , Ultrasonografía/métodos , Acústica , Vasos Sanguíneos/diagnóstico por imagen , Humanos , Lípidos , Propiedades de Superficie , Ultrasonografía Intervencional/métodos
20.
Ultrasound Med Biol ; 32(4): 503-12, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16616597

RESUMEN

The Björk-Shiley (BScc) mechanical heart valve has extensively been used in surgery from 1979 to 1986. There is, compared with equivalent valve types, increased occurrence of unexpected mechanical failure of the outlet strut of the valve, with a high incidence of mortality, when it occurs. Many approaches have been attempted to noninvasively determine BScc valve integrity. None of the approaches resulted in adequate assessment, mostly due to a lack of either sensitivity or specificity demonstrated in in vitro and/or in vivo studies. In our study we analyze leg movement of the BScc valves outlet strut during the cardiac cycle with ultrasound. For a broken strut, the movement of both legs will be significantly different, whereas the difference will be negligible for an intact strut. BScc valves were mounted in the mitral position in an in vitro pulse duplicator system. A focused single-element transducer was used to direct ultrasound on a leg of the outlet strut. Correlation-based time delay estimation was used to estimate differences in time of flight of the outlet strut echoes to determine outlet strut leg movement. The movement of an intact valve and a valve with a single-leg fracture with both ends grating against each other (SLF), the most difficult fracture to diagnose, has been studied. The results showed no significant difference in movement between both legs of the outlet strut of the intact BScc valve (amplitude of movement 9.2 microm +/- 0.1 microm). Whereas for the defective valve, the amplitude of movement of the broken leg of the SLF valve was 12 microm +/- 1.6 microm vs. 8.6 microm +/- 0.1 microm for the intact leg. In conclusion, the proposed method has shown to be feasible in vitro and has potentials for in vivo detection of BScc valve outlet strut fracture.


Asunto(s)
Prótesis Valvulares Cardíacas , Válvulas Cardíacas/diagnóstico por imagen , Falla de Prótesis , Ecocardiografía/instrumentación , Ecocardiografía/métodos , Estudios de Factibilidad , Humanos , Modelos Cardiovasculares , Movimiento (Física)
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA