Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Aging (Albany NY) ; 14(22): 9103-9127, 2022 11 18.
Artículo en Inglés | MEDLINE | ID: mdl-36403263

RESUMEN

Traditional Chinese medicine (TCM) is a promising and effective treatment for cancer with minimal side effects through a multi-active ingredient multitarget network. Radix Bupleuri and Rhizoma Cyperi are listed as herbs dispersing stagnated liver Qi in China. They have been used clinically to treat liver diseases for many years and recent pharmacological studies have shown that they inhibit the proliferation of hepatocellular carcinoma (HCC). However, the pharmacological mechanisms, potential targets, and clinical value of the Radix Bupleuri-Rhizoma Cyperi herb pair (CXP) for suppressing HCC growth have not been fully elucidated. We identified 44 CXP targets involved in the treatment of HCC using the GEO dataset and HERB database. An analysis of the Traditional Chinese Medicine System Pharmacology Database (TCMSP) showed that CXP exerts synergistic effects through 4 active ingredients, including quercetin, stigmasterol, isorhamnetin, and kaempferol. GO and KEGG analyses revealed that CXP mainly regulates HCC progression through metabolic pathways, the p53 signaling pathway, and the cell cycle. Additionally, we applied The Cancer Genome Atlas (TCGA)-liver hepatocellular carcinoma (LIHC) database to perform the expression patterns, clinical features, and prognosis of 6 genes (CCNB1, CDK1, CDK4, MYC, CDKN2A, and CHEK1) in cell cycle pathways to reveal that CXP suppresses HCC clinical therapeutic value. Moreover, based on molecular docking, we further verified that CXP exerts its anti-HCC activity through the interaction of multiple active components with cell cycle-related genes. We systematically revealed the potential pharmacological mechanisms and targets of CXP in HCC using multilevel data integration and molecular docking strategies.


Asunto(s)
Carcinoma Hepatocelular , Medicamentos Herbarios Chinos , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/tratamiento farmacológico , Carcinoma Hepatocelular/genética , Simulación del Acoplamiento Molecular , Medicamentos Herbarios Chinos/farmacología , Medicamentos Herbarios Chinos/uso terapéutico , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/genética , Medicina Tradicional China
2.
J Mass Spectrom Adv Clin Lab ; 23: 50-57, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35036987

RESUMEN

INTRODUCTION: Differential mobility separation (DMS) is an analytical technique used for rapid separation of ions and isomers based on gas phase mobility prior to entering a mass spectrometer for analysis. The entire DMS process is accomplished in fewer than 20 ms and can be used as a rapid alternative to chromatographic separation. OBJECTIVE: The primary objective was to evaluate the utility of DMS-tandem mass spectrometry (DMS-MS/MS) as a replacement for immunoassay-based clinical toxicology testing. METHODS: A sensitive DMS-MS/MS method was developed and validated for simultaneous identification of 33 drugs and metabolites in human urine samples. After DMS optimization, the method was validated and used to screen 56 clinical urine samples. These results were compared to results obtained by immunoassay. RESULTS: The DMS-MS/MS method achieved limits of detection ranging from 5 to 100 ng/mL. Moreover, the total analysis time was 2 min per sample. For the method performance evaluation, DMS-MS/MS results were compared with previously obtained urine toxicology immunoassay results. DMS-MS/MS showed higher sensitivity and identified 20% more drugs in urine, which were confirmed by LC-MS/MS. CONCLUSION: The DMS-MS/MS as applied in our lab demonstrated the capability for rapid drug screening and provided better analytical performance than immunoassay.

3.
J Mass Spectrom Adv Clin Lab ; 19: 34-45, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34820664

RESUMEN

BACKGROUND: Nitric oxide (NO) plays an important role in endothelial homeostasis. Asymmetric dimethyl arginine (ADMA), L-N monomethyl arginine (L-NMMA) and symmetric dimethyl arginine (SDMA), which are derivatives of methylarginine, directly or indirectly reduce NO production. Therefore, these metabolites are an important risk factor for various diseases, including cardiovascular diseases. Numerous methods have been developed for the measurement of methylarginine derivatives, but various difficulties have been encountered. This study aimed to develop a reliable, fast and cost-effective method for the analysis and measurement of methylarginine derivatives (ADMA, SDMA, L-NMMA) and related metabolites (arginine, citrulline, homoarginine, ornithine), and to validate this method according to Clinical and Laboratory Standards Institute (CLSI) protocols. METHODS: For the analysis of ADMA, SDMA, L-NMMA, arginine, homoarginine, citrulline, ornithine, 200 Âµl of serum were precipitated with methanol, and subsequently derivatized with a butanol solution containing 5% acetyl chloride. Butyl derivatives were separated using a C18 reverse phase column with a 5 min run time. Detection of analytes was achieved by utilising the specific fragmentation patterns identified through tandem mass spectrometry. RESULTS: The method was linear for ADMA, SDMA, L-NMMA, ornithine, arginine, homoarginine and citrulline in the ranges of 0.023-6.0, 0.021-5.5, 0.019-5.0, 0.015-250, 0.015-250, 0.019-5 and 0.015-250 µM, respectively. The inter-assay CV% values for all analytes was less than 9.8%. CONCLUSIONS: Data obtained from method validation studies shows that the developed method is highly sensitive, precise and accurate. Short analysis time, cost-effectiveness, and multiplexed analysis of these metabolites, with the same pretreatment steps, are the main advantages of the method.

4.
J Mass Spectrom Adv Clin Lab ; 21: 19-26, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34820673

RESUMEN

INTRODUCTION: Diagnosis of pheochromocytoma and paraganglioma (PPGL) is aided by the measurement of metanephrine (MN) and normetanephrine (NMN). Research suggests that 3-methoxytyramine (3MT), a dopamine (DA) metabolite, may serve as a biomarker of metastasis in patients with paraganglioma. Considering the very low endogenous plasma 3MT concentrations (<0.1 nM), highly sensitive and specific methods for 3MT are needed. METHODS: We developed a simple method for measurement of 3MT. Sample preparation was performed using solid phase micro-extraction with the eluates injected directly onto the LC-MS/MS. Data acquisition was performed in multiple reaction monitoring mode with an instrumental analysis time of 3 min per sample. We evaluated the method's performance and analyzed samples from healthy individuals and pathological specimens. RESULTS: The limit of quantitation and upper limit of linearity were 0.03 nM and 20 nM, respectively. The intra-/inter-day imprecision for pooled plasma samples at concentrations of 0.04 nM, 0.2 nM, and 2 nM was 10.7%/18.3%, 4.5%/8.9%, and 3.1%/0.9%, respectively. Among samples with MN, NMN, or both MN and NMN above the reference intervals (RIs), 0%, 16% and 46%, respectively, showed 3MT greater than the proposed upper RI value of 0.1 nM; 12% of samples with DA above the RI had 3MT above 0.1 nM. CONCLUSIONS: The developed method allowed accurate quantitation of 3MT in patient samples and would provide valuable information to clinicians diagnosing or monitoring patients with PPGL. High 3MT concentrations in patient samples with MN and NMN within the respective RIs may alert clinicians of the possibility of a DA-producing tumor.

5.
Clin Mass Spectrom ; 18: 48-53, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34820525

RESUMEN

BACKGROUND: In tandem mass spectrometry, analyte detection is based on collision-induced fragmentation, which is modulated by the collision energy (CE) setting. Variation in CE leads to differential ion yield, and optimization is usually performed empirically as "tuning" during method development. Our aim was to build a method to objectify the impact of collision energy settings on ion yield for individual compounds. METHODS: Collision energy (CE)-breakdown curves were generated based on acquisition files in which a large number of quasi-identical mass transitions were recorded simultaneously, with variation of CE over a defined range within a single injection. Ion yield (normalized to an internal standard recorded with a locked collision energy) was plotted as a curve versus CE settings. Piperacillin and testosterone were studied as exemplary analytes in matrix-free and serum matrix-based liquid chromatography tandem mass spectrometry (LC-MS/MS) measurements. More detailed testosterone CE-breakdown curves were investigated with regard to sample preparation techniques and the isotope labeling pattern of corresponding internal standards. RESULTS: CE-breakdown curves were found characteristically for the piperacillin quantifier transition with respect to CE-related maximum ion yield, as well as curve width and shape. A diverging curve profile was observed for the piperacillin qualifier transition. For testosterone analyses, no impact from different sample preparation techniques or the isotope labeling patterns on the selected CE was shown. CONCLUSION: CE-breakdown curves are a convenient and valuable tool to verify LC-MS/MS methods regarding consistent fragmentation characteristics between sample sources or native analytes and isotope-labeled counterparts.

6.
Clin Mass Spectrom ; 11: 37-41, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34841071

RESUMEN

Phosphatidylethanol (PEth) is a recently introduced biomarker with high specificity, high sensitivity, and response correlating with alcohol consumption. It has the potential to be a valuable biomarker in population studies on the health effects of alcohol, however its stability in long-term stored blood is not known. We used LC-MS/MS to assess the stability of PEth-16:0/18:1 in blood samples (packed erythrocytes) that were stored between 1 and 19 years at -80 °C in a biobank from a large population survey. The participants answered a life-style questionnaire that included questions on alcohol consumption. For analysis, we selected blood samples from seven homogenous ethanol consumption cohorts collected at intervals from 1997 to 2015. Despite the narrow stated alcohol consumption range, 10-15 g/day, there were large differences in PEth values between individuals in the cohorts, from below the limit of detection of 0.005 µmol/L to 1.40 µmol/L. The median was 0.08 µmol/L. Neither generalized linear modeling, nor principal component analysis revealed a statistically significant association between time of storage and PEth levels. The PEth results indicate that the participants had, on average, under-reported their alcohol consumption several-fold. The findings suggest that PEth in blood has a sufficient long-term stability for use as an alcohol biomarker in prospective case-control studies. Analysis of blood stored in biobanks could significantly improve the validity of assessments exploring the health effects of alcohol.

7.
Clin Mass Spectrom ; 12: 1-6, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34841073

RESUMEN

Tyrosinemia type 1 is an autosomal recessive aminoacidopathy caused by fumarylacetoacetate hydrolase (FAH) deficiency. Consequently, tyrosine and its metabolites accumulate, resulting in liver and kidney toxicity. Symptoms of the disease usually manifest after three weeks of life and include vomiting, failure to thrive, hepatomegaly, jaundice, bleeding diathesis, rickets and renal tubular dysfunction. Untreated, the disease eventually progresses to liver or kidney failure and generally results in a fatal outcome. Expedient diagnosis is critical because an early start of treatment can increase the likelihood of a positive outcome. Here, we report on a male newborn with a family history positive for tyrosinemia type 1 who was subjected to a metabolic work-up immediately after birth. Amino acids were quantified by tandem mass spectrometry coupled with ultra performance liquid chromatography. Urinary organic acids were analyzed on capillary gas chromatography coupled with mass spectrometry. DNA analysis of the FAH gene was performed by Sanger sequencing. On the first day of life, the patient's plasma amino acids showed an increased tyrosine concentration, while urine organic acids detected succinylacetone, a tyrosine metabolite specific for tyrosinemia type 1. The patient's DNA analysis revealed homozygosity of the c.554-1G > T mutation in the FAH gene, which was consistent with the diagnosis. Nitisinone treatment, combined with a dietary restriction of tyrosine and phenylalanine, was introduced immediately. Regular visits and measurement of amino acid concentrations, which enables therapy adjustment and treatment efficiency monitoring in patients with tyrosinemia type 1, has continued over the past 4+ years, and is expected to continue.

8.
Clin Mass Spectrom ; 13: 27-35, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34841083

RESUMEN

BACKGROUND: Highly accurate and sensitive method to measure testosterone in hypogonadal male, female and children is vital for proper diagnosis of hormone-related conditions and their treatment. OBJECTIVE: To develop an accurate and robust total testosterone ESI-LC-MS/MS quantification method with a simple sample preparation workflow and sufficient sensitivity for serum or plasma samples of all gender and age groups, via ketone functional group derivatization (using Amplifex™ Keto Reagent). METHOD: A simple sample preparation method to accommodate both low and high numbers of samples was developed using simultaneous protein precipitation and derivatization with Amplifex™ Keto reagent, followed by centrifugation and direct injection of supernatant into an LC-MS/MS system (SCIEX Topaz™ IVD LC-MS/MS, in which MS is equivalent to a SCIEX 4500MD Mass Spectrometer). Total testosterone in human serum or plasma samples was quantified using an external calibration curve generated by calibrators spanning a broad concentration range of ∼1-2000 ng/dL (10-20,000 pg/mL), traceable to NIST 971 SRM. 13C3-enriched testosterone was used as an internal standard to correct for both analyte loss during sample preparation and matrix effect during analysis (Supplementary Information: SI Fig. 4C). Two methods, one using a 96-well filter plate and another using Eppendorf tubes, were developed. Both methods were certified by the Centers for Disease Control (CDC) hormone standardization (HoSt) program for total serum testosterone. The feasibility of implementing the method for plasma and serum samples was tested via a small-scale method comparison study between matched pediatric serum and plasma samples derived from the same donor. In addition, plasma samples originating from the same donor collected in two different anticoagulant tube types (Li-heparin and K2EDTA) were compared. RESULTS: Using in-house formulated NIST 971-traceable calibrators, the method was linear (r2 > 0.999) between 1 and 2000 ng/dL (10 and 20,000 pg/mL) with a limit of detection of approximately 1 ng/dL (10 pg/mL). The testosterone concentration bias against 40 reference samples from the HoSt certification program was absolute <3% with an average %CV of ∼3-4%. More than 78% of samples passed the CDC bias criterion of ±6.4%. Comparison between pediatric matched serum and plasma samples resulted in high correlation (r2 = 0.997) and bias of <5%. The calculated % difference between matched adult serum and plasma samples was ∼1%. CONCLUSIONS: Feasibility for an accurate and streamlined method suitable for measuring total testosterone in all human samples was demonstrated with a choice of sample preparation workflow to suit low or high number of samples. The method can potentially be used for plasma matrix from different blood collection tubes (Li-Heparin and K2EDTA).

9.
J Pharm Biomed Anal ; 88: 180-90, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24055854

RESUMEN

Uridine 5'-diphosphate-glucuronosyltransferase (UGT)1A1 is a major phase II metabolism enzyme responsible for glucuronidation of drugs and endogenous compounds. The purpose of this study was to determine the expression level of UGT1A1 in human liver microsomes and human cell lines by using an isotope label-free LC-MS/MS method. A Waters Ultra performance liquid chromatography (UPLC) system coupled with an API 5500Qtrap mass spectrometer was used for the analysis. Two signature peptides (Pep-1, and Pep-2) were employed to quantify UGT1A1 by multiple reaction monitoring (MRM) approach. Standard addition method was used to validate the assay to account for the matrix effect. 17ß-Estradiol was used as the marker substrate to determine UGT1A1 activities. The validated method has a linear range of 200-0.0195nM for both signature peptides. The precision, accuracy, and matrix effect were in acceptable ranges. UGT1A1 expression levels were then determined using 8 individual human liver microsomes, a pooled human liver microsomes, three UGT1A1 genotyped human liver microsomes, and four cell lines (Caco-2, MCF-7, Hela, and HepG2). The correlations study showed that the UGT1A1 protein levels were strongly correlated with its glucuronidation activities in human liver microsomes (R(2)=0.85) and in microsomes prepared from cell lines (R(2)=0.95). Isotope-labeled peptides were not necessary for LC-MS/MS quantitation of proteins. The isotope label-free absolute quantification method used here had good accuracy, sensitivity, linear range, and reproducibility, and were used successfully for the accurate determination of UGT1A1 from tissues and cell lines.


Asunto(s)
Colorantes Fluorescentes/análisis , Glucuronidasa/química , Glucuronosiltransferasa/análisis , Animales , Células CACO-2 , Cromatografía Líquida de Alta Presión , Estradiol/química , Femenino , Genotipo , Células HeLa , Células Hep G2 , Humanos , Células MCF-7 , Masculino , Microsomas Hepáticos/efectos de los fármacos , Péptidos/química , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem , Distribución Tisular , Tripsina/química
10.
J Pharm Biomed Anal ; 88: 162-9, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24055700

RESUMEN

2-Phosphonomethyl pentanedioic acid (2-PMPA) is a potent and selective inhibitor of glutamate carboxypeptidase-II, an enzyme which catabolizes the abundant neuropeptide N-acetyl-aspartyl-glutamate (NAAG) to N-acetylaspartate (NAA) and glutamate. 2-PMPA demonstrates robust efficacy in numerous animal models of neurological disease, however its pharmacokinetics has not yet been fully described. 2-PMPA is a highly polar compound with multiple negative charges causing significant challenges for analysis in biological matrices. Here we report a derivatization method for the acidic groups that involved protein precipitation with acetonitrile followed by reaction with N-tert-butyldimethysilyl-N-methyltrifluoroacetamide (MTBSTFA). The silylated analyte with transitions (683→551.4) and the internal standard (669→537.2) were monitored by tandem mass spectrometry with electrospray positive ionization mode. The method was subsequently used to evaluate 2-PMPA pharmacokinetics in rats. Intraperitoneal administration of 100mg/kg 2-PMPA resulted in maximum concentration in plasma of 275µg/mL at 0.25h. The half-life, area under the curve, apparent clearance, and volume of distribution were 0.64h, 210µg×h/mL, 7.93mL/min/kg, and 0.44L/kg, respectively. The tissue/plasma ratios in brain, sciatic nerve and dorsal root ganglion were 0.018, 0.120 and 0.142, respectively. In summary, a sensitive analytical method for 2-PMPA is reported that can be employed for similarly charged molecules.


Asunto(s)
Inhibidores Enzimáticos/farmacocinética , Glutamato Carboxipeptidasa II/antagonistas & inhibidores , Compuestos Organofosforados/farmacocinética , Plasma/efectos de los fármacos , Animales , Área Bajo la Curva , Encéfalo/efectos de los fármacos , Calibración , Técnicas de Química Analítica , Química Farmacéutica , Cromatografía Liquida , Inhibidores Enzimáticos/sangre , Ganglios Espinales/efectos de los fármacos , Infusiones Parenterales , Masculino , Compuestos Organofosforados/sangre , Ratas , Ratas Wistar , Nervio Ciático/efectos de los fármacos , Espectrometría de Masas en Tándem , Distribución Tisular
11.
Clin Chim Acta ; 429: 30-3, 2014 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-24269713

RESUMEN

Methylmalonic aciduria (MMA) is one of the most frequent organic acidurias, a class of diseases caused by enzymatic defects mainly involved in the catabolism of branched-chain amino acids. Recently, mild MMA and C4-dicarboxylyl-carnitine (C4DC-C) accumulation have been reported in patients carrying mutation in genes encoding the α-subunit (SUCLG1) and the ß-subunit (SUCLA2) of the ADP-forming succinyl-CoA synthetase (SCS). We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify in dried blood spot the two isobaric compounds of C4DC-C, succinyl-carnitine and methylmalonyl-carnitine, to allow the differential diagnosis between classical MMA and SCS-related defects. This method, with an easy liquid-phase extraction and derivatization procedure, has been validated to demonstrate the specificity, linearity, recovery, lowest limit of quantification (LLOQ), accuracy and precision for quantitative determination of blood succinyl-carnitine and methylmalonyl-carnitine. The assay was linear over a concentration range of 0.025-10 µmol/L and achieved the LLOQ of 0.025 µmol/L for both metabolites. The average slope, intercept, and coefficient of linear regression (r(2)) were respectively: 0.3389 (95% confidence interval 0.2888-0.3889), 0.0113 (95% confidence interval -0.0157 to 0.0384), 0.9995 (95% confidence interval 0.9990-1.0000) for succinyl-carnitine and 0.5699 (95% confidence interval 0.5263-0.6134), 0.0319 (95% confidence interval -0.0038 to 0.0677), 0.9997 (95% confidence interval 0.9995-1.0000) for methylmalonyl-carnitine. Within-day and between-day coefficients of variation (CV) were 1.94% and 3.19% for succinyl-carnitine and 3.21%, and 2.56 for methylmalonyl-carnitine. This method is accurate and provides a new tool to differentiate patients with classical methylmalonic acidemia from those with SCS-related defects.


Asunto(s)
Carnitina/análogos & derivados , Carnitina/sangre , Pruebas con Sangre Seca/métodos , Adolescente , Niño , Preescolar , Cromatografía Liquida , Femenino , Humanos , Lactante , Recién Nacido , Límite de Detección , Modelos Lineales , Masculino , Espectrometría de Masas en Tándem
12.
J Pharm Biomed Anal ; 85: 245-52, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23973631

RESUMEN

The purpose of this study is to develop an UPLC-MS/MS method to quantify 3-hydroxyflavone (3-HF) and its metabolite, 3-hydroxyflavone-glucuronide (3-HFG) from biological samples. A Waters BEH C8 column was used with acetonitrile/0.1% formic acid in water as mobile phases. The mass analysis was performed in an API 5500 Qtrap mass spectrometer via multiple reaction monitoring (MRM) with positive scan mood. The one-step protein precipitation by acetonitrile was used to extract the analytes from blood. The results showed that the linear response range was 0.61-2500.00 nM for 3-HF and 0.31-2500.00 nM for 3-HFG. The intra-day variance is less than 16.5% and accuracy is in 77.7-90.6% for 3-HF and variance less than 15.9%, accuracy in 85.1-114.7% for 3-HFG. The inter-day variance is less than 20.2%, accuracy is in 110.6-114.2% for 3-HF and variance less than 15.6%, accuracy in 83.0-89.4% for 3-HFG. The analysis was done within 4.0 min. Only 10 µl of blood is needed due to the high sensitivity of this method. The validated method was successfully used to pharmacokinetic study in A/J mouse, transport study in the Caco-2 cell culture model, and glucuronidation study using mice liver and intestine microsomes. The applications revealed that this method can be used for 3-HF and 3-HFG analysis in blood as well as in bioequivalent buffers such HBSS and KPI.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Flavonoides/sangre , Glucurónidos/sangre , Espectrometría de Masas en Tándem/métodos , Absorción , Animales , Tampones (Química) , Células CACO-2 , Flavonoides/farmacocinética , Humanos , Masculino , Ratones
13.
Artículo en Inglés | MEDLINE | ID: mdl-24121745

RESUMEN

Glycine is an important amino acid neurotransmitter in the central nervous system (CNS) and a useful biomarker to indicate biological activity of drugs such as glycine reuptake inhibitors (GRI) in the brain. Here, we report how a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the fast and reliable analysis of glycine in brain microdialysates and cerebrospinal fluid (CSF) samples has been established. Additionally, we compare this method with the conventional approach of high performance liquid chromatography (HPLC) coupled to fluorescence detection (FD). The present LC-MS/MS method did not require any derivatisation step. Fifteen microliters of sample were injected for analysis. Glycine was detected by a triple quadrupole mass spectrometer in the positive electrospray ionisation (ESI) mode. The total running time was 5min. The limit of quantitation (LOQ) was determined as 100nM, while linearity was given in the range from 100nM to 100µM. In order to demonstrate the feasibility of the LC-MS/MS method, we measured glycine levels in striatal in vivo microdialysates and CSF of rats after administration of the commercially available glycine transporter 1 (GlyT1) inhibitor LY 2365109 (10mg/kg, p.o.). LY 2365109 produced 2-fold and 3-fold elevated glycine concentrations from 1.52µM to 3.6µM in striatal microdialysates and from 10.38µM to 36µM in CSF, respectively. In conclusion, we established a fast and reliable LC-MS/MS method, which can be used for the quantification of glycine in brain microdialysis and CSF samples in biomarker studies.


Asunto(s)
Química Encefálica , Cromatografía Liquida/métodos , Glicina/líquido cefalorraquídeo , Microdiálisis/métodos , Espectrometría de Masas en Tándem/métodos , Animales , Biomarcadores/líquido cefalorraquídeo , Masculino , Ratas , Ratas Wistar , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Clin Chim Acta ; 425: 3-8, 2013 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-23827692

RESUMEN

BACKGROUND: A rapid liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the quantification of reactive oxygen species (ROS) derived free oxysterols and cholesterol in human plasma and atherosclerotic plaque. METHOD: In vitro autoxidation of cholesterol during sample pretreatment was avoided by applying only one protein precipitation and re-concentration step using 80 µl plasma. For preparation of 10mg atherosclerotic plaques an additional liquid-liquid extraction was included. Free 7-keto-, 7-α/ß-hydroxy-, 5,6-α-epoxy-, 5,6-ß-epoxycholesterol, cholestane-3ß,5α,6ß-triol and cholesterol were separated within 7 min on a monolithic column. An API 4000 tandem mass spectrometer was applied in positive ionization mode using atmospheric pressure chemical ionization. RESULTS: The detection limit was 0.1 ng/ml and the linearity ranged from 0.5 to 0.75 to 2000 ng/ml for the oxysterols and from 50 to 1000 µg/ml for cholesterol. Recovery was between 80.9 and 107.9%. Between-run imprecision ranged from 7.9 to 11.7%. Analysis of plasma samples from additional 50 middle-aged volunteers revealed a large inter-individual variability (e.g. 7-ketocholesterol 2.63-30.47 ng/ml). Oxysterol concentrations normalized to cholesterol were about 43 times higher in carotid plaque compared to plasma (n=5). CONCLUSION: This rapid LC-MS/MS method enables reliable quantification focused on especially ROS-derived oxysterols in human plasma and atherosclerotic plaque samples under high-throughput conditions.


Asunto(s)
Arterias Carótidas/química , Colesterol/análogos & derivados , Hidroxicolesteroles/sangre , Cetocolesteroles/sangre , Placa Aterosclerótica/química , Especies Reactivas de Oxígeno/sangre , Calibración , Colesterol/sangre , Colesterol/aislamiento & purificación , Cromatografía Líquida de Alta Presión , Cromatografía Liquida , Femenino , Humanos , Hidroxicolesteroles/aislamiento & purificación , Isomerismo , Cetocolesteroles/aislamiento & purificación , Límite de Detección , Extracción Líquido-Líquido , Masculino , Espectrometría de Masas , Persona de Mediana Edad , Reproducibilidad de los Resultados , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA