Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.155
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(6): 443-454, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-37738114

RESUMEN

BACKGROUND AND AIMS: Low birth weight is a common pregnancy complication, which has been associated with higher risk of cardiometabolic disease in later life. Prior Mendelian randomization (MR) studies exploring this question do not distinguish the mechanistic contributions of variants that directly influence birth weight through the foetal genome (direct foetal effects), vs. variants influencing birth weight indirectly by causing an adverse intrauterine environment (indirect maternal effects). In this study, MR was used to assess whether birth weight, independent of intrauterine influences, is associated with cardiovascular disease risk and measures of adverse cardiac structure and function. METHODS: Uncorrelated (r2 < .001), genome-wide significant (P < 5 × 10-8) single nucleotide polymorphisms were extracted from genome-wide association studies summary statistics for birth weight overall, and after isolating direct foetal effects only. Inverse-variance weighted MR was utilized for analyses on outcomes of atrial fibrillation, coronary artery disease, heart failure, ischaemic stroke, and 16 measures of cardiac structure and function. Multiple comparisons were accounted for by Benjamini-Hochberg correction. RESULTS: Lower genetically-predicted birth weight, isolating direct foetal effects only, was associated with an increased risk of coronary artery disease (odds ratio 1.21, 95% confidence interval 1.06-1.37; P = .031), smaller chamber volumes, and lower stroke volume, but higher contractility. CONCLUSIONS: The results of this study support a causal role of low birth weight in cardiovascular disease, even after accounting for the influence of the intrauterine environment. This suggests that individuals with a low birth weight may benefit from early targeted cardiovascular disease prevention strategies, independent of whether this was linked to an adverse intrauterine environment during gestation.


Asunto(s)
Isquemia Encefálica , Enfermedad de la Arteria Coronaria , Accidente Cerebrovascular , Embarazo , Femenino , Humanos , Peso al Nacer/genética , Estudio de Asociación del Genoma Completo , Isquemia Encefálica/genética , Análisis de la Aleatorización Mendeliana , Polimorfismo de Nucleótido Simple/genética
2.
Magn Reson Med ; 92(2): 741-750, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38523462

RESUMEN

PURPOSE: To develop an open-source prototype of myocardial T1 mapping (Open-MOLLI) to improve accessibility to cardiac T1 mapping and evaluate its repeatability. With Open-MOLLI, we aim to enable faster implementation and testing of sequence modifications and to facilitate inter-scanner and cross-vendor reproducibility studies. METHODS: Open-MOLLI is an inversion-recovery sequence using a balanced SSFP (bSSFP) readout, with inversion and triggering schemes based on the 5(3)3 MOLLI sequence, developed in Pulseq. Open-MOLLI and MOLLI sequences were acquired in the ISMRM/NIST phantom and 21 healthy volunteers. In 18 of those subjects, Open-MOLLI and MOLLI were repeated in the same session (test-retest). RESULTS: Phantom T1 values were comparable between methods, specifically for the vial with reference T1 value most similar to healthy myocardium T1 (T1vial3 = 1027 ms): T1MOLLI = 1011 ± 24 ms versus T1Open-MOLLI = 1009 ± 20 ms. In vivo T1 estimates were similar between Open-MOLLI and MOLLI (T1MOLLI = 1004 ± 33 ms vs. T1Open-MOLLI = 998 ± 52 ms), with a mean difference of -17 ms (p = 0.20), despite noisier Open-MOLLI weighted images and maps. Repeatability measures were slightly higher for Open-MOLLI (RCMOLLI = 3.0% vs. RCOpen-MOLLI = 4.4%). CONCLUSION: The open-source sequence Open-MOLLI can be used for T1 mapping in vivo with similar mean T1 values to the MOLLI method. Open-MOLLI increases the accessibility to cardiac T1 mapping, providing also a base sequence to which further improvements can easily be added and tested.


Asunto(s)
Fantasmas de Imagen , Humanos , Reproducibilidad de los Resultados , Adulto , Masculino , Femenino , Algoritmos , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Adulto Joven , Miocardio
3.
Magn Reson Med ; 91(5): 1936-1950, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38174593

RESUMEN

PURPOSE: Widely used conventional 2D T2 * approaches that are based on breath-held, electrocardiogram (ECG)-gated, multi-gradient-echo sequences are prone to motion artifacts in the presence of incomplete breath holding or arrhythmias, which is common in cardiac patients. To address these limitations, a 3D, non-ECG-gated, free-breathing T2 * technique that enables rapid whole-heart coverage was developed and validated. METHODS: A continuous random Gaussian 3D k-space sampling was implemented using a low-rank tensor framework for motion-resolved 3D T2 * imaging. This approach was tested in healthy human volunteers and in swine before and after intravenous administration of ferumoxytol. RESULTS: Spatial-resolution matched T2 * images were acquired with 2-3-fold reduction in scan time using the proposed T2 * mapping approach relative to conventional T2 * mapping. Compared with the conventional approach, T2 * images acquired with the proposed method demonstrated reduced off-resonance and flow artifacts, leading to higher image quality and lower coefficient of variation in T2 *-weighted images of the myocardium of swine and humans. Mean myocardial T2 * values determined using the proposed and conventional approaches were highly correlated and showed minimal bias. CONCLUSION: The proposed non-ECG-gated, free-breathing, 3D T2 * imaging approach can be performed within 5 min or less. It can overcome critical image artifacts from undesirable cardiac and respiratory motion and bulk off-resonance shifts at the heart-lung interface. The proposed approach is expected to facilitate faster and improved cardiac T2 * mapping in those with limited breath-holding capacity or arrhythmias.


Asunto(s)
Corazón , Miocardio , Humanos , Animales , Porcinos , Corazón/diagnóstico por imagen , Respiración , Contencion de la Respiración , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Magnética , Imagenología Tridimensional/métodos
4.
Magn Reson Med ; 91(1): 266-279, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37799087

RESUMEN

PURPOSE: Interactive cardiac MRI is used for fast scan planning and MR-guided interventions. However, the requirement for real-time acquisition and near-real-time visualization constrains the achievable spatio-temporal resolution. This study aims to improve interactive imaging resolution through optimization of undersampled spiral sampling and leveraging of deep learning for low-latency reconstruction (deep artifact suppression). METHODS: A variable density spiral trajectory was parametrized and optimized via HyperBand to provide the best candidate trajectory for rapid deep artifact suppression. Training data consisted of 692 breath-held CINEs. The developed interactive sequence was tested in simulations and prospectively in 13 subjects (10 for image evaluation, 2 during catheterization, 1 during exercise). In the prospective study, the optimized framework-HyperSLICE- was compared with conventional Cartesian real-time and breath-hold CINE imaging in terms quantitative and qualitative image metrics. Statistical differences were tested using Friedman chi-squared tests with post hoc Nemenyi test (p < 0.05). RESULTS: In simulations the normalized RMS error, peak SNR, structural similarity, and Laplacian energy were all statistically significantly higher using optimized spiral compared to radial and uniform spiral sampling, particularly after scan plan changes (structural similarity: 0.71 vs. 0.45 and 0.43). Prospectively, HyperSLICE enabled a higher spatial and temporal resolution than conventional Cartesian real-time imaging. The pipeline was demonstrated in patients during catheter pull back, showing sufficiently fast reconstruction for interactive imaging. CONCLUSION: HyperSLICE enables high spatial and temporal resolution interactive imaging. Optimizing the spiral sampling enabled better overall image quality and superior handling of image transitions compared with radial and uniform spiral trajectories.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Cinemagnética , Humanos , Imagen por Resonancia Cinemagnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Estudios Prospectivos , Imagen por Resonancia Magnética , Contencion de la Respiración
5.
Magn Reson Med ; 2024 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-39323040

RESUMEN

PURPOSE: To develop a method for quantifying the fatty acid composition (FAC) of human epicardial adipose tissue (EAT) using accelerated MRI and identify its potential for detecting proinflammatory biomarkers in patients with ST-segment elevation myocardial infarction (STEMI). METHODS: A multi-echo radial gradient-echo sequence was developed for accelerated imaging during a breath hold using a locally low-rank denoising technique to reconstruct undersampled images. FAC mapping was achieved by fitting the multi-echo images to a multi-resonance complex signal model based on triglyceride characterization. Validation of the method was assessed using a phantom comprised of multiple oils. In vivo imaging was performed in STEMI patients (n = 21; 14 males/seven females). FAC was quantified in EAT, subcutaneous AT, and abdominal visceral AT. RESULTS: Phantom validation demonstrated strong correlations (r > 0.97) and statistical significance (p < 0.0001) between measured and reference proton density fat fraction and FAC values. In vivo imaging of STEMI patients revealed a distinct EAT FAC profile compared to subcutaneous AT and abdominal visceral AT. EAT FAC parameters had significant correlations with left ventricular (LV) end-diastolic volume index (p < 0.05), LV end-systolic volume index (p < 0.05), and LV mass index (p < 0.05). CONCLUSIONS: Accelerated MRI enabled accurate quantification of human EAT FAC. The relationships between the EAT FAC profile and LV structure and function in STEMI patients suggest the potential of EAT FAC MRI as a biomarker for adipose tissue quality and inflammatory status in cardiovascular disease.

6.
Magn Reson Med ; 91(5): 1951-1964, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38181169

RESUMEN

PURPOSE: Simultaneous PET-MRI improves inflammatory cardiac disease diagnosis. However, challenges persist in respiratory motion and mis-registration between free-breathing 3D PET and 2D breath-held MR images. We propose a free-breathing non-rigid motion-compensated 3D T2 -mapping sequence enabling whole-heart myocardial tissue characterization in a hybrid 3T PET-MR system and provides non-rigid respiratory motion fields to correct also simultaneously acquired PET data. METHODS: Free-breathing 3D whole-heart T2 -mapping was implemented on a hybrid 3T PET-MRI system. Three datasets were acquired with different T2 -preparation modules (0, 28, 55 ms) using 3-fold undersampled variable-density Cartesian trajectory. Respiratory motion was estimated via virtual 3D image navigators, enabling multi-contrast non-rigid motion-corrected MR reconstruction. T2 -maps were computed using dictionary-matching. Approach was tested in phantom, 8 healthy subjects, 14 MR only and 2 PET-MR patients with suspected cardiac disease and compared with spin echo reference (phantom) and clinical 2D T2 -mapping (in-vivo). RESULTS: Phantom results show a high correlation (R2 = 0.996) between proposed approach and gold standard 2D T2 mapping. In-vivo 3D T2 -mapping average values in healthy subjects (39.0 ± 1.4 ms) and patients (healthy tissue) (39.1 ± 1.4 ms) agree with conventional 2D T2 -mapping (healthy = 38.6 ± 1.2 ms, patients = 40.3 ± 1.7 ms). Bland-Altman analysis reveals bias of 1.8 ms and 95% limits of agreement (LOA) of -2.4-6 ms for healthy subjects, and bias of 1.3 ms and 95% LOA of -1.9 to 4.6 ms for patients. CONCLUSION: Validated efficient 3D whole-heart T2 -mapping at hybrid 3T PET-MRI provides myocardial inflammation characterization and non-rigid respiratory motion fields for simultaneous PET data correction. Comparable T2 values were achieved with both 3D and 2D methods. Improved image quality was observed in the PET images after MR-based motion correction.


Asunto(s)
Miocarditis , Miocardio , Humanos , Imagen por Resonancia Magnética , Movimiento (Física) , Imagenología Tridimensional/métodos , Tomografía de Emisión de Positrones , Corazón/diagnóstico por imagen , Fantasmas de Imagen
7.
Magn Reson Med ; 92(3): 1104-1114, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38576068

RESUMEN

PURPOSE: To develop and evaluate a deep learning (DL) -based rapid image reconstruction and motion correction technique for high-resolution Cartesian first-pass myocardial perfusion imaging at 3T with whole-heart coverage for both single-slice (SS) and simultaneous multi-slice (SMS) acquisitions. METHODS: 3D physics-driven unrolled network architectures were utilized for the reconstruction of high-resolution Cartesian perfusion imaging. The SS and SMS multiband (MB) = 2 networks were trained from 135 slices from 20 subjects. Structural similarity index (SSIM), peak SNR (PSNR), and normalized RMS error (NRMSE) were assessed, and prospective images were blindly graded by two experienced cardiologists (5, excellent; 1, poor). For respiratory motion correction, a 2D U-Net based motion corrected network was proposed, and the temporal fidelity and second-order derivative were calculated to assess the performance of the motion correction. RESULTS: Excellent performance was demonstrated in the proposed technique with high SSIM and PSNR, and low NRMSE. Image quality scores were (4.3 [4.3, 4.4], 4.5 [4.4, 4.6], 4.3 [4.3, 4.4], and 4.5 [4.3, 4.5]) for SS DL and SS L1-SENSE, MB = 2 DL and MB = 2 SMS-L1-SENSE, respectively, showing no statistically significant difference (p > 0.05 for SS and SMS) between (SMS)-L1-SENSE and the proposed DL technique. The network inference time was around 4 s per dynamic perfusion series with 40 frames while the time of (SMS)-L1-SENSE with GPU acceleration was approximately 30 min. CONCLUSION: The proposed DL-based image reconstruction and motion correction technique enabled rapid and high-quality reconstruction for SS and SMS MB = 2 high-resolution Cartesian first-pass perfusion imaging at 3T.


Asunto(s)
Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador , Movimiento (Física) , Imagen de Perfusión Miocárdica , Humanos , Imagen de Perfusión Miocárdica/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Masculino , Femenino , Corazón/diagnóstico por imagen , Imagenología Tridimensional/métodos , Adulto , Estudios Prospectivos , Relación Señal-Ruido , Artefactos
8.
Magn Reson Med ; 92(4): 1421-1439, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38726884

RESUMEN

PURPOSE: To develop a novel low-rank tensor reconstruction approach leveraging the complete acquired data set to improve precision and repeatability of multiparametric mapping within the cardiovascular MR Multitasking framework. METHODS: A novel approach that alternated between estimation of temporal components and spatial components using the entire data set acquired (i.e., including navigator data and imaging data) was developed to improve reconstruction. The precision and repeatability of the proposed approach were evaluated on numerical simulations, 10 healthy subjects, and 10 cardiomyopathy patients at multiple scan times for 2D myocardial T1/T2 mapping with MR Multitasking and were compared with those of the previous navigator-derived fixed-basis approach. RESULTS: In numerical simulations, the proposed approach outperformed the previous fixed-basis approach with lower T1 and T2 error against the ground truth at all scan times studied and showed better motion fidelity. In human subjects, the proposed approach showed no significantly different sharpness or T1/T2 measurement and significantly improved T1 precision by 20%-25%, T2 precision by 10%-15%, T1 repeatability by about 30%, and T2 repeatability by 25%-35% at 90-s and 50-s scan times The proposed approach at the 50-s scan time also showed comparable results with that of the previous fixed-basis approach at the 90-s scan time. CONCLUSION: The proposed approach improved precision and repeatability for quantitative imaging with MR Multitasking while maintaining comparable motion fidelity, T1/T2 measurement, and septum sharpness and had the potential for further reducing scan time from 90 s to 50 s.


Asunto(s)
Algoritmos , Humanos , Reproducibilidad de los Resultados , Masculino , Femenino , Interpretación de Imagen Asistida por Computador/métodos , Adulto , Aumento de la Imagen/métodos , Persona de Mediana Edad , Sensibilidad y Especificidad , Procesamiento de Imagen Asistido por Computador/métodos , Cardiomiopatías/diagnóstico por imagen , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Corazón/diagnóstico por imagen
9.
Magn Reson Med ; 92(4): 1511-1524, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38872384

RESUMEN

PURPOSE: To develop and validate a highly efficient motion compensated free-breathing isotropic resolution 3D whole-heart joint T1/T2 mapping sequence with anatomical water/fat imaging at 0.55 T. METHODS: The proposed sequence takes advantage of shorter T1 at 0.55 T to acquire three interleaved water/fat volumes with inversion-recovery preparation, no preparation, and T2 preparation, respectively. Image navigators were used to facilitate nonrigid motion-compensated image reconstruction. T1 and T2 maps were jointly calculated by a dictionary matching method. Validations were performed with simulation, phantom, and in vivo experiments on 10 healthy volunteers and 1 patient. The performance of the proposed sequence was compared with conventional 2D mapping sequences including modified Look-Locker inversion recovery and T2-prepared balanced steady-SSFP sequence. RESULTS: The proposed sequence has a good T1 and T2 encoding sensitivity in simulation, and excellent agreement with spin-echo reference T1 and T2 values was observed in a standardized T1/T2 phantom (R2 = 0.99). In vivo experiments provided good-quality co-registered 3D whole-heart T1 and T2 maps with 2-mm isotropic resolution in a short scan time of about 7 min. For healthy volunteers, left-ventricle T1 mean and SD measured by the proposed sequence were both comparable with those of modified Look-Locker inversion recovery (640 ± 35 vs. 630 ± 25 ms [p = 0.44] and 49.9 ± 9.3 vs. 54.4 ± 20.5 ms [p = 0.42]), whereas left-ventricle T2 mean and SD measured by the proposed sequence were both slightly lower than those of T2-prepared balanced SSFP (53.8 ± 5.5 vs. 58.6 ± 3.3 ms [p < 0.01] and 5.2 ± 0.9 vs. 6.1 ± 0.8 ms [p = 0.03]). Myocardial T1 and T2 in the patient measured by the proposed sequence were in good agreement with conventional 2D sequences and late gadolinium enhancement. CONCLUSION: The proposed sequence simultaneously acquires 3D whole-heart T1 and T2 mapping with anatomical water/fat imaging at 0.55 T in a fast and efficient 7-min scan. Further investigation in patients with cardiovascular disease is now warranted.


Asunto(s)
Tejido Adiposo , Imagenología Tridimensional , Fantasmas de Imagen , Humanos , Imagenología Tridimensional/métodos , Masculino , Tejido Adiposo/diagnóstico por imagen , Adulto , Corazón/diagnóstico por imagen , Reproducibilidad de los Resultados , Algoritmos , Femenino , Imagen por Resonancia Magnética/métodos , Respiración , Agua Corporal/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Voluntarios Sanos
10.
Cardiovasc Diabetol ; 23(1): 319, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39198860

RESUMEN

BACKGROUND: Sodium-glucose cotransporter-2 (SGLT2) inhibitors have demonstrated reduction in heart failure outcomes in patients with type 2 diabetes mellitus, although the exact mechanism of benefit remains unclear. Alteration in left atrial (LA) function due to chronic pressure or volume overload is a hallmark of heart failure. OBJECTIVE: To evaluate the effect of the SGLT2 inhibitor empagliflozin on LA volume and function. METHODS: 90 patients with coronary artery disease and type 2 diabetes (T2DM) were randomized to empagliflozin (n = 44) or placebo (n = 46), and underwent cardiac magnetic resonance (CMR) imaging at baseline and after 6 months. The main outcome was change in LA volume; LA function, including active and passive components, was also measured by a blinded reader. RESULTS: At baseline, there was no significant difference in LA volumes between the empagliflozin (indexed maximum LA volume 26.4 ± 8.4mL/m2, minimum LA volume 11.1 ± 5.7mL/m2) and placebo (indexed maximum LA volume 28.7 ± 8.2mL/m2, minimum LA volume 12.6 ± 5.0mL/m2) groups. After 6 months, changes in LA volumes did not differ with adjusted difference (empagliflozin minus placebo): 0.99 mL/m2 (95% CI: -1.7 to 3.7 mL/m2; p = 0.47) for indexed maximum LA volume, and 0.87 mL/m2 (95% CI: -0.9 to 2.6 mL/m2; p = 0.32) for indexed minimum LA volume. Changes in total LA emptying fraction were also similar, with between-group adjusted mean difference - 0.01 (95% CI: -0.05 to 0.03, p = 0.59). CONCLUSION: SGLT2 inhibition with empagliflozin for 6 months did not have a significant impact on LA volume and function in patients with T2DM and coronary artery disease. (Effects of Empagliflozin on Cardiac Structure in Patients with Type 2 Diabetes [EMPA-HEART]; NCT02998970).


Asunto(s)
Función del Atrio Izquierdo , Compuestos de Bencidrilo , Enfermedad de la Arteria Coronaria , Diabetes Mellitus Tipo 2 , Glucósidos , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Humanos , Glucósidos/uso terapéutico , Glucósidos/efectos adversos , Compuestos de Bencidrilo/uso terapéutico , Compuestos de Bencidrilo/efectos adversos , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/fisiopatología , Diabetes Mellitus Tipo 2/complicaciones , Inhibidores del Cotransportador de Sodio-Glucosa 2/uso terapéutico , Inhibidores del Cotransportador de Sodio-Glucosa 2/efectos adversos , Masculino , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Persona de Mediana Edad , Anciano , Función del Atrio Izquierdo/efectos de los fármacos , Resultado del Tratamiento , Factores de Tiempo , Método Doble Ciego , Remodelación Atrial/efectos de los fármacos , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/efectos de los fármacos , Atrios Cardíacos/diagnóstico por imagen
11.
Cardiovasc Diabetol ; 23(1): 28, 2024 01 13.
Artículo en Inglés | MEDLINE | ID: mdl-38218882

RESUMEN

BACKGROUND: Sarcopenia is frequently found in patients with heart failure with reduced ejection fraction (HFrEF) and is associated with reduced exercise capacity, poor quality of life and adverse outcomes. Recent evidence suggests that axial thoracic skeletal muscle size could be used as a surrogate to assess sarcopenia in HFrEF. Since diabetes mellitus (DM) is one of the most common comorbidities with HFrEF, we aimed to explore the potential association of axial thoracic skeletal muscle size with left ventricular (LV) remodeling and determine its prognostic significance in this condition. METHODS: A total of 243 diabetes patients with HFrEF were included in this study. Bilateral axial thoracic skeletal muscle size was obtained using cardiac MRI. Patients were stratified by the tertiles of axial thoracic skeletal muscle index (SMI). LV structural and functional indices, as well as amino-terminal pro-B-type natriuretic peptide (NT-proBNP), were measured. The determinants of elevated NT-proBNP were assessed using linear regression analysis. The associations between thoracic SMI and clinical outcomes were assessed using a multivariable Cox proportional hazards model. RESULTS: Patients in the lowest tertile of thoracic SMI displayed a deterioration in LV systolic strain in three components, together with an increase in LV mass and a heavier burden of myocardial fibrosis (all P < 0.05). Moreover, thoracic SMI (ß = -0.25; P < 0.001), rather than body mass index (ß = -0.04; P = 0.55), was independently associated with the level of NT-proBNP. The median follow-up duration was 33.6 months (IQR, 20.4-52.8 months). Patients with adverse outcomes showed a lower thoracic SMI (40.1 [34.3, 47.9] cm2/m2 vs. 45.3 [37.3, 55.0] cm2/m2; P < 0.05) but a similar BMI (P = 0.76) compared with those without adverse outcomes. A higher thoracic SMI indicated a lower risk of adverse outcomes (hazard ratio: 0.96; 95% confidence interval: 0.92-0.99; P = 0.01). CONCLUSIONS: With respect to diabetes patients with HFrEF, thoracic SMI is a novel alternative for evaluating muscle wasting in sarcopenia that can be obtained by a readily available routine cardiac MRI protocol. A reduction in thoracic skeletal muscle size predicts poor outcomes in the context of DM with HFrEF.


Asunto(s)
Diabetes Mellitus , Insuficiencia Cardíaca , Sarcopenia , Disfunción Ventricular Izquierda , Humanos , Insuficiencia Cardíaca/diagnóstico por imagen , Sarcopenia/diagnóstico por imagen , Sarcopenia/epidemiología , Calidad de Vida , Biomarcadores , Volumen Sistólico/fisiología , Péptido Natriurético Encefálico , Imagen por Resonancia Magnética , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Fragmentos de Péptidos , Músculo Esquelético/diagnóstico por imagen , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología
12.
J Magn Reson Imaging ; 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38216546

RESUMEN

BACKGROUND: Quantification of aortic morphology plays an important role in the evaluation and follow-up assessment of patients with aortic diseases, but often requires labor-intensive and operator-dependent measurements. Automatic solutions would help enhance their quality and reproducibility. PURPOSE: To design a deep learning (DL)-based automated approach for aortic landmarks and lumen detection derived from three-dimensional (3D) MRI. STUDY TYPE: Retrospective. POPULATION: Three hundred ninety-one individuals (female: 47%, age = 51.9 ± 18.4) from three sites, including healthy subjects and patients (hypertension, aortic dilation, Turner syndrome), randomly divided into training/validation/test datasets (N = 236/77/78). Twenty-five subjects were randomly selected and analyzed by three operators with different levels of expertise. FIELD STRENGTH/SEQUENCE: 1.5-T and 3-T, 3D spoiled gradient-recalled or steady-state free precession sequences. ASSESSMENT: Reinforcement learning and a two-stage network trained using reference landmarks and segmentation from an existing semi-automatic software were used for aortic landmark detection and segmentation from sinotubular junction to coeliac trunk. Aortic segments were defined using the detected landmarks while the aortic centerline was extracted from the segmentation and morphological indices (length, aortic diameter, and volume) were computed for both the reference and the proposed segmentations. STATISTICAL TESTS: Segmentation: Dice similarity coefficient (DSC), Hausdorff distance (HD), average symmetrical surface distance (ASSD); landmark detection: Euclidian distance (ED); model robustness: Spearman correlation, Bland-Altman analysis, Kruskal-Wallis test for comparisons between reference and DL-derived aortic indices; inter-observer study: Williams index (WI). A WI 95% confidence interval (CI) lower bound >1 indicates that the method is within the inter-observer variability. A P-value <0.05 was considered statistically significant. RESULTS: DSC was 0.90 ± 0.05, HD was 12.11 ± 7.79 mm, and ASSD was 1.07 ± 0.63 mm. ED was 5.0 ± 6.1 mm. A good agreement was found between all DL-derived and reference aortic indices (r >0.95, mean bias <7%). Our segmentation and landmark detection performances were within the inter-observer variability except the sinotubular junction landmark (CI = 0.96;1.04). DATA CONCLUSION: A DL-based aortic segmentation and anatomical landmark detection approach was developed and applied to 3D MRI data for achieve aortic morphology evaluation. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.

13.
J Magn Reson Imaging ; 59(2): 522-532, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37203257

RESUMEN

BACKGROUND: Vertical run-length nonuniformity (VRLN) is a texture feature representing heterogeneity within native T1 images and reflects the extent of cardiac fibrosis. In uremic cardiomyopathy, interstitial fibrosis was the major histological alteration. The prognostic value of VRLN in patients with end-stage renal disease (ESRD) remains unclear. PURPOSE: To evaluate the prognostic value of VRLN MRI in patients with ESRD. STUDY TYPE: Prospective. POPULATION: A total of 127 ESRD patients (30 participants in the major adverse cardiac events, MACE group). FIELD STRENGTH/SEQUENCE: 3.0 T/steady-state free precession sequence, modified Look-Locker imaging. ASSESSMENT: MRI image qualities were assessed by three independent radiologists. VRLN values were measured in the myocardium on the mid-ventricular short-axis slice of T1 mapping. Left ventricular (LV) mass, LV end-diastolic and end-systolic volume, as well as LV global strain cardiac parameters were measured. STATISTICAL TESTS: The primary endpoint was the incident of MACE from enrollment time to January 2023. MACE is a composite endpoint consisting of all-cause mortality, acute myocardial infarction, stroke, heart failure hospitalization, and life-threatening arrhythmia. Cox proportional-hazards regression was performed to test whether VRLN independently correlated with MACE. The intraclass correlation coefficients of VRLN were calculated to evaluate intraobserver and interobserver reproducibility. The C-index was computed to examine the prognostic value of VRLN. P-value <0.05 were considered statistically significant. RESULTS: Participants were followed for a median of 26 months. VRLN, age, LV end-systolic volume index, and global longitudinal strain remained significantly associated with MACE in the multivariable model. Adding VRLN to a baseline model containing clinical and conventional cardiac MRI parameters significantly improved the accuracy of the predictive model (C-index of the baseline model: 0.781 vs. the model added VRLN: 0.814). DATA CONCLUSION: VRLN is a novel marker for risk stratification toward MACE in patients with ESRD, superior to native T1 mapping and LV ejection fraction. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Cardiomiopatías , Fallo Renal Crónico , Humanos , Pronóstico , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Riesgo , Imagen por Resonancia Magnética , Función Ventricular Izquierda , Volumen Sistólico , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/diagnóstico por imagen , Valor Predictivo de las Pruebas , Imagen por Resonancia Cinemagnética/métodos
14.
J Cardiovasc Magn Reson ; 26(1): 100001, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38218434

RESUMEN

BACKGROUND: Echocardiographic studies indicate South Asian people have smaller ventricular volumes, lower mass and more concentric remodelling than White European people, but there are no data using cardiac MRI (CMR). We aimed to compare CMR quantified cardiac structure and function in White European and South Asian people. METHODS: Healthy White European and South Asian participants in the UK Biobank Imaging CMR sub-study were identified by excluding those with a history of cardiovascular disease, hypertension, obesity or diabetes. Ethnic groups were matched by age and sex. Cardiac volumes, mass and feature tracking strain were compared. RESULTS: 121 matched pairs (77 male/44 female, mean age 58 ± 8 years) of South Asian and White European participants were included. South Asian males and females had smaller absolute but not indexed left ventricular (LV) volumes, and smaller absolute and indexed right ventricular volumes, with lower absolute and indexed LV mass and lower LV mass:volume than White European participants. Although there were no differences in ventricular or atrial ejection fractions, LV global longitudinal strain was higher in South Asian females than White European females but not males, and global circumferential strain was higher in both male and South Asian females than White European females. Peak early diastolic strain rates were higher in South Asian versus White European males, but not different between South Asian and White European females. CONCLUSIONS: Contrary to echocardiographic studies, South Asian participants in the UK Biobank study had less concentric remodelling and higher global circumferential strain than White European subjects. These findings emphasise the importance of sex- and ethnic- specific normal ranges for cardiac volumes and function.


Asunto(s)
Pueblo Asiatico , Pueblo Europeo , Disparidades en el Estado de Salud , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Bancos de Muestras Biológicas , Voluntarios Sanos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas , Factores Raciales , Factores Sexuales , Biobanco del Reino Unido , Reino Unido , Función Ventricular Derecha , Población Blanca , Personas del Sur de Asia
15.
J Cardiovasc Magn Reson ; 26(1): 101039, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38521391

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) is an important imaging modality for the assessment and management of adult patients with congenital heart disease (CHD). However, conventional techniques for three-dimensional (3D) whole-heart acquisition involve long and unpredictable scan times and methods that accelerate scans via k-space undersampling often rely on long iterative reconstructions. Deep-learning-based reconstruction methods have recently attracted much interest due to their capacity to provide fast reconstructions while often outperforming existing state-of-the-art methods. In this study, we sought to adapt and validate a non-rigid motion-corrected model-based deep learning (MoCo-MoDL) reconstruction framework for 3D whole-heart MRI in a CHD patient cohort. METHODS: The previously proposed deep-learning reconstruction framework MoCo-MoDL, which incorporates a non-rigid motion-estimation network and a denoising regularization network within an unrolled iterative reconstruction, was trained in an end-to-end manner using 39 CHD patient datasets. Once trained, the framework was evaluated in eight CHD patient datasets acquired with seven-fold prospective undersampling. Reconstruction quality was compared with the state-of-the-art non-rigid motion-corrected patch-based low-rank reconstruction method (NR-PROST) and against reference images (acquired with three-or-four-fold undersampling and reconstructed with NR-PROST). RESULTS: Seven-fold undersampled scan times were 2.1 ± 0.3 minutes and reconstruction times were ∼30 seconds, approximately 240 times faster than an NR-PROST reconstruction. Image quality comparable to the reference images was achieved using the proposed MoCo-MoDL framework, with no statistically significant differences found in any of the assessed quantitative or qualitative image quality measures. Additionally, expert image quality scores indicated the MoCo-MoDL reconstructions were consistently of a higher quality than the NR-PROST reconstructions of the same data, with the differences in 12 of the 22 scores measured for individual vascular structures found to be statistically significant. CONCLUSION: The MoCo-MoDL framework was applied to an adult CHD patient cohort, achieving good quality 3D whole-heart images from ∼2-minute scans with reconstruction times of ∼30 seconds.


Asunto(s)
Aprendizaje Profundo , Cardiopatías Congénitas , Interpretación de Imagen Asistida por Computador , Valor Predictivo de las Pruebas , Humanos , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/fisiopatología , Reproducibilidad de los Resultados , Adulto , Masculino , Femenino , Adulto Joven , Imagenología Tridimensional , Factores de Tiempo , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética
16.
J Cardiovasc Magn Reson ; 26(1): 100998, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38237901

RESUMEN

Cardiac Magnetic Resonance (CMR) protocols can be lengthy and complex, which has driven the research community to develop new technologies to make these protocols more efficient and patient-friendly. Two different approaches to improving CMR have been proposed, specifically "all-in-one" CMR, where several contrasts and/or motion states are acquired simultaneously, and "real-time" CMR, in which the examination is accelerated to avoid the need for breathholding and/or cardiac gating. The goal of this two-part manuscript is to describe these two different types of emerging rapid CMR protocols. To this end, the vision of all-in-one and real-time imaging are described, along with techniques which have been devised and tested along the pathway of clinical implementation. The pros and cons of the different methods are presented, and the remaining open needs of each are detailed. Part 1 tackles the "All-in-One" approaches, and Part 2 focuses on the "Real-Time" approaches along with an overall summary of these emerging methods.


Asunto(s)
Imagen por Resonancia Magnética , Valor Predictivo de las Pruebas , Humanos , Predicción , Cardiopatías/diagnóstico por imagen , Cardiopatías/fisiopatología , Factores de Tiempo , Interpretación de Imagen Asistida por Computador , Reproducibilidad de los Resultados , Difusión de Innovaciones
17.
J Cardiovasc Magn Reson ; 26(1): 100997, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38237900

RESUMEN

Cardiovascular magnetic resonance (CMR) protocols can be lengthy and complex, which has driven the research community to develop new technologies to make these protocols more efficient and patient-friendly. Two different approaches to improving CMR have been proposed, specifically "all-in-one" CMR, where several contrasts and/or motion states are acquired simultaneously, and "real-time" CMR, in which the examination is accelerated to avoid the need for breathholding and/or cardiac gating. The goal of this two-part manuscript is to describe these two different types of emerging rapid CMR. To this end, the vision of each is described, along with techniques which have been devised and tested along the pathway of clinical implementation. The pros and cons of the different methods are presented, and the remaining open needs of each are detailed. Part 1 will tackle the "all-in-one" approaches, and Part 2 the "real-time" approaches along with an overall summary of these emerging methods.


Asunto(s)
Enfermedades Cardiovasculares , Imagen por Resonancia Magnética , Valor Predictivo de las Pruebas , Humanos , Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Cardiovasculares/fisiopatología , Predicción , Interpretación de Imagen Asistida por Computador , Difusión de Innovaciones , Factores de Tiempo , Reproducibilidad de los Resultados , Pronóstico
18.
J Cardiovasc Magn Reson ; : 101096, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39278414

RESUMEN

BACKGROUND: Cardiovascular MRI (CMR) faces challenges due to the interference of bright fat signals in visualizing structures like coronary arteries. Effective fat suppression is crucial, especially when using whole-heart CMR techniques. Conventional methods often fall short due to rapid fat signal recovery, leading to residual fat content hindering visualization. Water-selective off-resonant radiofrequency (RF) pulses have been proposed but come with tradeoffs between pulse duration, which increases scan time, and increased RF energy deposit, which limits their applicability due to specific absorption rate (SAR) constraints. The study introduces a lipid-insensitive binomial off-resonant (LIBOR) RF pulse, which addresses concerns about SAR and scan time, and aims to provide a comprehensive quantitative comparison with published off-resonant RF pulses for CMR at 3T. METHODS: A short (1ms) LIBOR pulse, with reduced RF power requirements, was developed and implemented in a free-breathing respiratory-self-navigated 3D radial whole-heart CMR sequence at 3T. A binomial off-resonant rectangular (BORR) pulse with matched duration, as well as previously published lipid-insensitive binomial off-resonant excitation (LIBRE) pulses (1ms and 2.2ms), were implemented and optimized for fat suppression in numerical simulations and validated in volunteers (n=3). Whole-heart CMR was performed in volunteers(n=10) with all four pulses. The signal-to-noise ratio (SNR) of ventricular blood, skeletal muscle, myocardium, and subcutaneous fat and the coronary vessel detection rates and sharpness were compared. RESULTS: Experimental results validated numerical findings and near homogeneous fat suppression was achieved with all four pulses. Comparing the short RF pulses (1ms), LIBOR reduced the RF power nearly two-fold compared with LIBRE, and three-fold compared with BORR, and LIBOR significantly decreased overall fat SNR from cardiac scans, compared to LIBRE and BORR. The reduction in RF pulse duration (from 2.2ms to 1ms) shortened the whole-heart acquisition from 8.5min to 7min. No significant differences in coronary arteries detection and sharpness were found when comparing all four pulses. CONCLUSION: LIBOR pulses enabled whole-heart CMR under 7minutes at 3T, with large volume fat signal suppression, while reducing RF power compared with LIBRE and BORR pulses. LIBOR is an excellent candidate to address SAR problems encountered in CMR sequences where fat suppression remains challenging and short RF pulses are required. AVAILABILITY OF DATA AND MATERIALS: An online repository containing the anonymized human MRI raw data, as well as RF pulse shapes used in this study is publicly available at: https://zenodo.org/records/8338079(PART 1: KNEE V1-V3, HEART V1-V5) https://zenodo.org/records/10715769 (PART 2: HEART V6-V10) Matlab code to 1) simulate the different RF pulses within a GRE sequence and 2) to read and display the anonymized raw data is available from: https://github.com/QIS-MRI/LIBOR_LIBRE_BORR_SimulationCode The compiled research sequence can be requested through the Teamplay platform of Siemens Healthineers.

19.
AJR Am J Roentgenol ; 222(4): e2330357, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38323782

RESUMEN

BACKGROUND. MRI-based prognostic evaluation in patients with dilated cardiomyopathy (DCM) has historically used markers of late gadolinium enhancement (LGE) and feature tracking (FT)-derived left ventricular global longitudinal strain (LVGLS). Early data indicate that FT-derived left atrial strain (LAS) parameters, including reservoir, conduit, and booster, may also have prognostic roles in such patients. OBJECTIVE. The purpose of our study was to evaluate the prognostic utility of LAS parameters, derived from MRI FT, in patients with ischemic or nonischemic DCM, including in comparison with the traditional parameters of LGE and LVGLS. METHODS. This retrospective study included 811 patients with ischemic or nonischemic DCM (median age, 60 years; 640 men, 171 women) who underwent cardiac MRI at any of five centers. FT-derived LAS parameters and LVGLS were measured using two- and four-chamber cine images. LGE percentage was quantified. Patients were assessed for a composite outcome of all-cause mortality or heart failure hospitalization. Multivariable Cox regression analyses including demographic characteristics, cardiovascular risk factors, medications used, and a wide range of cardiac MRI parameters were performed. Kaplan-Meier analyses with log-rank tests were also performed. RESULTS. A total of 419 patients experienced the composite outcome. Patients who did, versus those who did not, experience the composite outcome had larger LVGLS (-6.7% vs -8.3%, respectively; p < .001) as well as a smaller LAS reservoir (13.3% vs 19.3%, p < .001), LAS conduit (4.7% vs 8.0%, p < .001), and LAS booster (8.1% vs 10.3%, p < .001) but no significant difference in LGE (10.1% vs 11.3%, p = .51). In multivariable Cox regression analyses, significant independent predictors of the composite outcome included LAS reservoir (HR = 0.96, p < .001) and LAS conduit (HR = 0.91, p < .001). LAS booster and LGE were not significant independent predictors in the models. LVGLS was a significant independent predictor only in a model that initially included LAS booster but not the other LAS parameters. In Kaplan-Meier analysis, all three LAS parameters were significantly associated with the composite outcome (p < .001). CONCLUSION. In this multicenter study, LAS reservoir and LAS conduit were significant independent prognostic markers in patients with ischemic or nonischemic DCM, showing greater prognostic utility than the currently applied markers of LVGLS and LGE. CLINICAL IMPACT. FT-derived LAS analysis provides incremental prognostic information in patients with DCM.


Asunto(s)
Cardiomiopatía Dilatada , Imagen por Resonancia Cinemagnética , Humanos , Femenino , Masculino , Cardiomiopatía Dilatada/diagnóstico por imagen , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Imagen por Resonancia Cinemagnética/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Anciano , Isquemia Miocárdica/diagnóstico por imagen , Medios de Contraste , Imagen por Resonancia Magnética/métodos
20.
BMC Cardiovasc Disord ; 24(1): 25, 2024 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-38172712

RESUMEN

BACKGROUND: Heart failure with preserved ejection fraction (HFpEF) is a heterogenous multi-system syndrome with limited efficacious treatment options. The prevalence of Type 2 diabetes (T2D) continues to rise and predisposes patients to HFpEF, and HFpEF remains one of the biggest challenges in cardiovascular medicine today. Novel therapeutic targets are required to meet this important clinical need. Deep phenotyping studies including -OMIC analyses can provide important pathogenic information to aid the identification of such targets. The aims of this study were to determine; 1) the impact of a low-energy diet on plasma sphingolipid/ceramide profiles in people with T2D compared to healthy controls and, 2) if the change in sphingolipid/ceramide profile is associated with reverse cardiovascular remodelling. METHODS: Post-hoc analysis of a randomised controlled trial (NCT02590822) including adults with T2D with no cardiovascular disease who completed a 12-week low-energy (∼810 kcal/day) meal-replacement plan (MRP) and matched healthy controls (HC). Echocardiography, cardiac MRI and a fasting blood for lipidomics were undertaken pre/post-intervention. Candidate biomarkers were identified from case-control comparison (fold change > 1.5 and statistical significance p < 0.05) and their response to the MRP reported. Association between change in biomarkers and change indices of cardiac remodelling were explored. RESULTS: Twenty-four people with T2D (15 males, age 51.1 ± 5.7 years), and 25 HC (15 male, 48.3 ± 6.6 years) were included. Subjects with T2D had increased left ventricular (LV) mass:volume ratio (0.84 ± 0.13 vs. 0.70 ± 0.08, p < 0.001), increased systolic function but impaired diastolic function compared to HC. Twelve long-chain polyunsaturated sphingolipids, including four ceramides, were downregulated in subjects with T2D at baseline. Three sphingomyelin species and all ceramides were inversely associated with LV mass:volume. There was a significant increase in all species and shift towards HC following the MRP, however, none of these changes were associated with reverse cardiac remodelling. CONCLUSION: The lack of association between change in sphingolipids/ceramides and reverse cardiac remodelling following the MRP casts doubt on a causative role of sphingolipids/ceramides in the progression of heart failure in T2D. TRIAL REGISTRATION: NCT02590822.


Asunto(s)
Diabetes Mellitus Tipo 2 , Insuficiencia Cardíaca , Remodelación Ventricular , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Biomarcadores , Ceramidas , Ayuno , Esfingolípidos , Volumen Sistólico/fisiología , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA